[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927882":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},927882,599,1,"单选题","某多层住宅，采用现浇钢筋混凝土剪力墙结构，结构平面立面均规则，抗震等级为三级，以地下室顶板作为上部结构的嵌固部位。底层某双肢墙有 A、B两个墙肢。已知A墙肢截面组合的剪力计算值Vw=180kN，同时B墙肢出现了大偏心受拉。试问，A墙肢截面组合的剪力设计值V（kN），应与下列何项数值最为接近？（ ）[2011年真题]",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","215",false,{"key":16,"text":17,"correct":14},"B","235",{"key":19,"text":20,"correct":14},"C","250",{"key":22,"text":23,"correct":24},"D","270",true,"底层属于底部加强部位，弯矩设计值应乘以弯矩增大系数。根据《建筑抗震设计规范》（GB 50011—2010）第6.2.7条第3款规定，当任一墙肢出现偏心受拉时，另一墙肢的剪力和弯矩设计值应乘以增大系数1.25。另根据第6.2.8条规定，三级剪力墙底部加强部位，应乘以剪力增大系数1.2。因此，代入公式可得：剪力设计值V=1.25×1.2×180=270kN。由此可知，D项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]