[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927870":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},927870,599,1,"单选题","某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 1.试问，该防震缝的宽度δ（mm）至少应取下列何项数值？（ ）",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","110",false,{"key":16,"text":17,"correct":18},"B","140",true,{"key":20,"text":21,"correct":14},"C","150",{"key":23,"text":24,"correct":14},"D","180","根据《建筑抗震设计规范》（GB 50011—2010）第6.1.4条可知，最小防震缝宽度应根据抗震设防烈度、结构材料种类、结构类型、结构单元的房屋高度等确定。根据第1款第3项规定，防震缝两侧结构类型不同时，宜按需要较宽防震缝的结构类型和较低房屋高度确定缝宽。本题中防震缝宽的三个要素为：抗震设防烈度为8度、结构类型为钢筋混凝土框架结构、较低结构单元的房屋高度，即A栋房屋高度21m。根据该条第l款，按21m高的A栋框架结构确定防震缝的宽度，δ=100+20×（21-15）\u002F3=140mm。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]