[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-60":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":360},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,60,50,2979,[13,33,45,57,69,81,93,105,117,129,141,153,165,177,189,201,209,219,231,243,255,267,279,291,303,314,326,338,350],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":29,"analysis":32},922205,"单选题","对医院污水液氯消毒处理，一级处理出水加氯量为( )mg\u002FL。",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","15-20",false,{"key":23,"text":24,"correct":21},"B","20-25",{"key":26,"text":27,"correct":21},"C","25-30",{"key":29,"text":30,"correct":31},"D","30～50",true,"",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":35,"options":36,"answer":19,"analysis":32},922206,"热媒为蒸汽时，铸铁柱型和长翼型散热器的工作压力不应大于200kPa，是考虑到( )。",[37,39,41,43],{"key":19,"text":38,"correct":31},"铸铁强度不够",{"key":23,"text":40,"correct":21},"防止表面湿度过高",{"key":26,"text":42,"correct":21},"降低散热器成本",{"key":29,"text":44,"correct":21},"以上都不对",{"id":46,"libraryId":5,"type":8,"typeLabel":15,"stem":47,"options":48,"answer":23,"analysis":32},922207,"公共厨房、卫生间通风应保持( )。",[49,51,53,55],{"key":19,"text":50,"correct":21},"正压",{"key":23,"text":52,"correct":31},"负压",{"key":26,"text":54,"correct":21},"常压",{"key":29,"text":56,"correct":21},"无压",{"id":58,"libraryId":5,"type":8,"typeLabel":15,"stem":59,"options":60,"answer":26,"analysis":32},922208,"普通风机盘管，不具备( )功能。",[61,63,65,67],{"key":19,"text":62,"correct":21},"加热",{"key":23,"text":64,"correct":21},"冷却",{"key":26,"text":66,"correct":31},"加湿",{"key":29,"text":68,"correct":21},"去湿",{"id":70,"libraryId":5,"type":8,"typeLabel":15,"stem":71,"options":72,"answer":26,"analysis":32},922209,"对于采用大气式热力除氧的较大型锅炉房，除氧水箱应布置在( )。，",[73,75,77,79],{"key":19,"text":74,"correct":21},"辅助间一层",{"key":23,"text":76,"correct":21},"辅助间二层",{"key":26,"text":78,"correct":31},"辅助间三层",{"key":29,"text":80,"correct":21},"锅炉间后面",{"id":82,"libraryId":5,"type":8,"typeLabel":15,"stem":83,"options":84,"answer":26,"analysis":32},922210,"在住宅的供电系统设计中，( )接地方式不宜采用。",[85,87,89,91],{"key":19,"text":86,"correct":21},"TN-S系统",{"key":23,"text":88,"correct":21},"TN-C-S系统",{"key":26,"text":90,"correct":31},"ⅠT系统",{"key":29,"text":92,"correct":21},"TT系统",{"id":94,"libraryId":5,"type":8,"typeLabel":15,"stem":95,"options":96,"answer":19,"analysis":32},922211,"关于保安闭路监视系统，下述说法不正确的是( )。",[97,99,101,103],{"key":19,"text":98,"correct":31},"闭路监视信号与电缆电视信号是同一类信号，因而可以用同一根电缆传输",{"key":23,"text":100,"correct":21},"闭路监视信号是视频信号，可以用同轴电缆，也可以调制成射频信号用射频电缆传输",{"key":26,"text":102,"correct":21},"闭路监视控制室宜设在环境噪声和电磁干扰小的地方",{"key":29,"text":104,"correct":21},"监控室对温度、湿度有较高的要求，故应设空调，而电缆电视系统属共用天线系统，应分别设置",{"id":106,"libraryId":5,"type":8,"typeLabel":15,"stem":107,"options":108,"answer":29,"analysis":32},922212,"制冷机的风冷式冷凝器的冷凝温度宜比夏季空气调节室外计算干球温度高( )。",[109,111,113,115],{"key":19,"text":110,"correct":21},"5℃",{"key":23,"text":112,"correct":21},"8℃",{"key":26,"text":114,"correct":21},"10～",{"key":29,"text":116,"correct":31},"15～",{"id":118,"libraryId":5,"type":8,"typeLabel":15,"stem":119,"options":120,"answer":23,"analysis":32},922213,"中水管道与生活饮用水管道、排水管道平行埋设时，其水平净距为( )m。",[121,123,125,127],{"key":19,"text":122,"correct":21},"≮0.3",{"key":23,"text":124,"correct":31},"≮0.5",{"key":26,"text":126,"correct":21},"≮0.7",{"key":29,"text":128,"correct":21},"≮0.8",{"id":130,"libraryId":5,"type":8,"typeLabel":15,"stem":131,"options":132,"answer":29,"analysis":32},922214,"制冷机的蒸发式冷凝器的冷凝温度宜比夏季空气调节室外计算湿球温度高( )。",[133,135,137,139],{"key":19,"text":134,"correct":21},"3℃～5℃",{"key":23,"text":136,"correct":21},"5℃～8C",{"key":26,"text":138,"correct":21},"8℃～10℃",{"key":29,"text":140,"correct":31},"8℃～15℃",{"id":142,"libraryId":5,"type":8,"typeLabel":15,"stem":143,"options":144,"answer":26,"analysis":32},922215,"中支架敷设时管道保温层外表面至地面的净距一般为( )m。",[145,147,149,151],{"key":19,"text":146,"correct":21},"0.5-1.0",{"key":23,"text":148,"correct":21},"1.0～2.0",{"key":26,"text":150,"correct":31},"2.0-2.5",{"key":29,"text":152,"correct":21},"2.5-4.5",{"id":154,"libraryId":5,"type":8,"typeLabel":15,"stem":155,"options":156,"answer":29,"analysis":32},922216,"下列医院污水消毒方法中不妥的是( )。",[157,159,161,163],{"key":19,"text":158,"correct":21},"液氯消毒",{"key":23,"text":160,"correct":21},"漂白粉消毒",{"key":26,"text":162,"correct":21},"现场制备的次氯酸钠消毒",{"key":29,"text":164,"correct":31},"氯气直接消毒",{"id":166,"libraryId":5,"type":8,"typeLabel":15,"stem":167,"options":168,"answer":29,"analysis":32},922217,"某高位水箱出水管上安装了一出水流向的止回阀，在下列几种说法中( )是正确的。",[169,171,173,175],{"key":19,"text":170,"correct":21},"按安装要求设止回阀",{"key":23,"text":172,"correct":21},"便于从水箱内出水",{"key":26,"text":174,"correct":21},"防止水箱下给水管道内水回流",{"key":29,"text":176,"correct":31},"发生火灾时由消防水泵供给的消防系统用水不能进入消防水箱",{"id":178,"libraryId":5,"type":8,"typeLabel":15,"stem":179,"options":180,"answer":26,"analysis":32},922218,"下面( )不属于双管上分式低压蒸汽采暖系统的优点。",[181,183,185,187],{"key":19,"text":182,"correct":21},"采暖系统作用半径大",{"key":23,"text":184,"correct":21},"安全卫生条件好",{"key":26,"text":186,"correct":31},"不需要较大的管沟",{"key":29,"text":188,"correct":21},"系统运行时不致产生较大的噪声",{"id":190,"libraryId":5,"type":8,"typeLabel":15,"stem":191,"options":192,"answer":26,"analysis":32},922219,"对湿陷性黄土地区的排出管穿基础时，与外墙转角处或主要承重墙连接处的基础外缘的距离不得小于( )m。",[193,195,197,199],{"key":19,"text":194,"correct":21},"0.2",{"key":23,"text":196,"correct":21},"0.5",{"key":26,"text":198,"correct":31},"1.0",{"key":29,"text":200,"correct":21},"1.2",{"id":202,"libraryId":5,"type":8,"typeLabel":15,"stem":203,"options":204,"answer":29,"analysis":32},922220,"设稳压泵的消火栓给水系统图是( )。",[205,206,207,208],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":31},{"id":210,"libraryId":5,"type":8,"typeLabel":15,"stem":211,"options":212,"answer":29,"analysis":32},922221,"全空调的公共建筑，就全楼而言，其楼内的空气应为( )。",[213,214,215,217],{"key":19,"text":50,"correct":21},{"key":23,"text":52,"correct":21},{"key":26,"text":216,"correct":21},"0压(不正也不负)",{"key":29,"text":218,"correct":31},"部分正压，部分负压",{"id":220,"libraryId":5,"type":8,"typeLabel":15,"stem":221,"options":222,"answer":23,"analysis":32},922222,"关于巡更管理系统的组成，下列叙述正确的是( )。",[223,225,227,229],{"key":19,"text":224,"correct":21},"由巡更站点开关、信息采集器、计算器及软件组成",{"key":23,"text":226,"correct":31},"由信息钮、信息采集器、信息传输器、计算器及软件组成",{"key":26,"text":228,"correct":21},"由巡更站点开关、信息采集器、信息传输器及软件组成",{"key":29,"text":230,"correct":21},"由信息钮、信息采集器、计算器及软件组成",{"id":232,"libraryId":5,"type":8,"typeLabel":15,"stem":233,"options":234,"answer":19,"analysis":32},922223,"下列( )类型低压电动机是民用建筑和工业建筑中最常用的。",[235,237,239,241],{"key":19,"text":236,"correct":31},"交流异步鼠笼型电动机",{"key":23,"text":238,"correct":21},"同步电动机",{"key":26,"text":240,"correct":21},"直流电动机",{"key":29,"text":242,"correct":21},"交流异步绕线电动机",{"id":244,"libraryId":5,"type":8,"typeLabel":15,"stem":245,"options":246,"answer":23,"analysis":32},922224,"消防联动控制装置的直流电源电压，应采用( )。",[247,249,251,253],{"key":19,"text":248,"correct":21},"36Ⅴ",{"key":23,"text":250,"correct":31},"24Ⅴ",{"key":26,"text":252,"correct":21},"12Ⅴ",{"key":29,"text":254,"correct":21},"6Ⅴ",{"id":256,"libraryId":5,"type":8,"typeLabel":15,"stem":257,"options":258,"answer":29,"analysis":32},922225,"管道穿过空调机房围护结构处，其孔洞四周的缝隙应填充密实，其原因是( )。",[259,261,263,265],{"key":19,"text":260,"correct":21},"防止漏风",{"key":23,"text":262,"correct":21},"避免温降",{"key":26,"text":264,"correct":21},"减少振动",{"key":29,"text":266,"correct":31},"隔绝噪声",{"id":268,"libraryId":5,"type":8,"typeLabel":15,"stem":269,"options":270,"answer":19,"analysis":32},922226,"电力系统由( )组成。Ⅰ.发电厂；Ⅱ，电力网；Ⅲ.变配电系统；Ⅳ，电力用户",[271,273,275,277],{"key":19,"text":272,"correct":31},"Ⅰ、Ⅱ、Ⅳ",{"key":23,"text":274,"correct":21},"Ⅰ、Ⅱ、Ⅲ",{"key":26,"text":276,"correct":21},"Ⅱ、Ⅲ、Ⅳ",{"key":29,"text":278,"correct":21},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"id":280,"libraryId":5,"type":8,"typeLabel":15,"stem":281,"options":282,"answer":26,"analysis":32},922227,"辅助建筑物及辅助用室的托儿所、幼儿园、医务室的采暖温度不应低于( )。",[283,285,287,289],{"key":19,"text":284,"correct":21},"25℃",{"key":23,"text":286,"correct":21},"23℃",{"key":26,"text":288,"correct":31},"20℃",{"key":29,"text":290,"correct":21},"14℃",{"id":292,"libraryId":5,"type":8,"typeLabel":15,"stem":293,"options":294,"answer":23,"analysis":32},922228,"常用室内消防水箱的储水量，一般标准容积不包括( )m3。",[295,297,299,301],{"key":19,"text":296,"correct":21},"6",{"key":23,"text":298,"correct":31},"10",{"key":26,"text":300,"correct":21},"12",{"key":29,"text":302,"correct":21},"18",{"id":304,"libraryId":5,"type":8,"typeLabel":15,"stem":305,"options":306,"answer":26,"analysis":32},922229,"居住小区室外生活给水管与污水管外壁的水平净距不宜小于( )m。",[307,308,310,312],{"key":19,"text":196,"correct":21},{"key":23,"text":309,"correct":21},"0.7",{"key":26,"text":311,"correct":31},"0.8",{"key":29,"text":313,"correct":21},"1",{"id":315,"libraryId":5,"type":8,"typeLabel":15,"stem":316,"options":317,"answer":19,"analysis":32},922230,"室内排水沟与室外排水管道连接处，应设( )。",[318,320,322,324],{"key":19,"text":319,"correct":31},"水封装置",{"key":23,"text":321,"correct":21},"检查井",{"key":26,"text":323,"correct":21},"沉沙井",{"key":29,"text":325,"correct":21},"跌水井",{"id":327,"libraryId":5,"type":8,"typeLabel":15,"stem":328,"options":329,"answer":29,"analysis":32},922231,"建筑内塑料排水管道的设置，下述( )做法是错误的。",[330,332,334,336],{"key":19,"text":331,"correct":21},"塑料排水立管应避免设置在易受机械撞击处，如不能避免时，应增加保护措施",{"key":23,"text":333,"correct":21},"塑料排水立管与家用灶具边净距不得小于0.4m",{"key":26,"text":335,"correct":21},"生活排水立管应尽量避免穿越卧室、病房等对卫生、安静要求较高的房间。",{"key":29,"text":337,"correct":31},"室内塑料排水管道可不设伸缩节",{"id":339,"libraryId":5,"type":8,"typeLabel":15,"stem":340,"options":341,"answer":29,"analysis":32},922232,"防空地下室给水管道上的防护阀门不可以采用( )。",[342,344,346,348],{"key":19,"text":343,"correct":21},"阀芯为不锈钢的闸阀",{"key":23,"text":345,"correct":21},"阀芯为铜材质的闸阀",{"key":26,"text":347,"correct":21},"阀芯为不锈钢的截止阀",{"key":29,"text":349,"correct":31},"阀芯为不锈钢的蝶阀",{"id":351,"libraryId":5,"type":8,"typeLabel":15,"stem":352,"options":353,"answer":29,"analysis":32},922233,"为截留汽车洗车污水中的油类，污水在隔油沉砂池中停留时间为( )mⅠn。",[354,355,357,359],{"key":19,"text":198,"correct":21},{"key":23,"text":356,"correct":21},"2.O",{"key":26,"text":358,"correct":21},"5",{"key":29,"text":298,"correct":31},[361,364,367,370,374,376],{"id":8,"name":362,"category":7,"favorite":363},"领导干部任职前廉政法规知识测试题",92,{"id":365,"name":366,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":368,"name":369,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":371,"name":372,"category":7,"favorite":373},534,"BIM工程师",0,{"id":375,"name":372,"category":7,"favorite":373},535,{"id":377,"name":378,"category":7,"favorite":373},536,"安全人A证"]