[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-59":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":593},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,59,50,2979,[13,33,45,57,69,81,93,103,115,126,138,150,161,173,185,197,207,219,231,239,251,263,275,283,293,305,317,328,335,345,357,369,381,392,404,416,428,440,452,464,476,488,500,512,524,536,548,560,572,581],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":23,"analysis":32},922155,"单选题","低压配电设计所选用的电器，应符合国家现行的有关标准，并应符合( )。Ⅰ.电器的额定电压应与所在回路标称电压相适应；Ⅱ.电器的额定电流不应大于所在回路的计算电流；Ⅲ，电器的额定频率应与所在回路的频率相适应；Ⅳ.电器应满足短路条件下的动稳定与热稳定的要求",[18,22,26,29],{"key":19,"text":20,"correct":21},"A","Ⅰ、Ⅱ、Ⅲ、Ⅳ",false,{"key":23,"text":24,"correct":25},"B","Ⅰ、Ⅲ、Ⅳ",true,{"key":27,"text":28,"correct":21},"C","Ⅰ、Ⅱ、Ⅲ",{"key":30,"text":31,"correct":21},"D","Ⅱ、m、Ⅳ","",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":35,"options":36,"answer":30,"analysis":32},922156,"在梁突出顶棚的高度小于( )mm时，顶棚上设置的感烟、感温探测器可不考虑梁对探测器保护面积的影响。",[37,39,41,43],{"key":19,"text":38,"correct":21},"50",{"key":23,"text":40,"correct":21},"100",{"key":27,"text":42,"correct":21},"150",{"key":30,"text":44,"correct":25},"200",{"id":46,"libraryId":5,"type":8,"typeLabel":15,"stem":47,"options":48,"answer":19,"analysis":32},922157,"有关民用建筑空调系统自动控制的目的，下述不正确的是( )。",[49,51,53,55],{"key":19,"text":50,"correct":25},"节省投资",{"key":23,"text":52,"correct":21},"节省运行费",{"key":27,"text":54,"correct":21},"方便管理",{"key":30,"text":56,"correct":21},"减少运行人员",{"id":58,"libraryId":5,"type":8,"typeLabel":15,"stem":59,"options":60,"answer":23,"analysis":32},922158,"在高温热水采暖系统中，热水的温度是( )。",[61,63,65,67],{"key":19,"text":62,"correct":21},"100℃",{"key":23,"text":64,"correct":25},"110℃",{"key":27,"text":66,"correct":21},"130℃",{"key":30,"text":68,"correct":21},"150℃",{"id":70,"libraryId":5,"type":8,"typeLabel":15,"stem":71,"options":72,"answer":27,"analysis":32},922159,"关于地漏水封深度，以下正确的是( )。",[73,75,77,79],{"key":19,"text":74,"correct":21},"水封不得小于30mm",{"key":23,"text":76,"correct":21},"水封不得小于40mm",{"key":27,"text":78,"correct":25},"水封不得小于50mm",{"key":30,"text":80,"correct":21},"水封不得小于60mm",{"id":82,"libraryId":5,"type":8,"typeLabel":15,"stem":83,"options":84,"answer":30,"analysis":32},922160,"室内消火栓的间距不应超过30m不适用的建筑是( )。",[85,87,89,91],{"key":19,"text":86,"correct":21},"高层厂房、高架库房",{"key":23,"text":88,"correct":21},"高层民用建筑",{"key":27,"text":90,"correct":21},"甲、乙类厂房",{"key":30,"text":92,"correct":25},"高层建筑的裙房",{"id":94,"libraryId":5,"type":8,"typeLabel":15,"stem":95,"options":96,"answer":30,"analysis":32},922161,"符合下列( )条件时，用电单位宜设置自备电源。Ⅰ.作为一级负荷中特别重要负荷的应急电源；Ⅱ.设置自备电源较从电力系统中取得第二电源经济合理时；Ⅲ.电力系统中取得第二电源不能满足一级负荷要求的条件时；Ⅳ.所属地区远离供电系统，经与供电部门共同规划，设置自备电源作为主电源经济合理时",[97,99,100,102],{"key":19,"text":98,"correct":21},"Ⅰ、Ⅱ、Ⅳ",{"key":23,"text":28,"correct":21},{"key":27,"text":101,"correct":21},"Ⅱ、Ⅲ、Ⅳ",{"key":30,"text":20,"correct":25},{"id":104,"libraryId":5,"type":8,"typeLabel":15,"stem":105,"options":106,"answer":30,"analysis":32},922162,"火灾确认后，下述联动控制错误的是( )。",[107,109,111,113],{"key":19,"text":108,"correct":21},"关闭有关部位的防火门、防火卷帘，并接收其反馈信号",{"key":23,"text":110,"correct":21},"发出控制信号，强制非消防电梯停于首层，并接收其反馈信号",{"key":27,"text":112,"correct":21},"接通火灾应急照明和疏散指示灯",{"key":30,"text":114,"correct":25},"接通全楼的火灾警报装置和火灾事故广播，切断全楼的非消防电源",{"id":116,"libraryId":5,"type":8,"typeLabel":15,"stem":117,"options":118,"answer":23,"analysis":32},922163,"由市政电网对中小容量电力负荷的建筑物供电时，一般采用的供电电压为10kⅤ或380\u002F220Ⅴ，当无特殊情况时，是只按电力负荷的大小来确定供电电压，下列容量应采用380／220Ⅴ供电电压的是( )kW。",[119,121,122,124],{"key":19,"text":120,"correct":21},"550",{"key":23,"text":44,"correct":25},{"key":27,"text":123,"correct":21},"1000",{"key":30,"text":125,"correct":21},"2000",{"id":127,"libraryId":5,"type":8,"typeLabel":15,"stem":128,"options":129,"answer":27,"analysis":32},922164,"为降低跨步电压，防直击雷的人工接地装置距建筑物人口处及人行道不应小于( )m。",[130,132,134,136],{"key":19,"text":131,"correct":21},"1",{"key":23,"text":133,"correct":21},"2",{"key":27,"text":135,"correct":25},"3",{"key":30,"text":137,"correct":21},"5",{"id":139,"libraryId":5,"type":8,"typeLabel":15,"stem":140,"options":141,"answer":30,"analysis":32},922165,"压缩式制冷机由下列( )设备组成。",[142,144,146,148],{"key":19,"text":143,"correct":21},"压缩机、蒸发器、冷却泵",{"key":23,"text":145,"correct":21},"压缩机、冷凝器、冷却泵",{"key":27,"text":147,"correct":21},"冷凝器、蒸发器、冷却泵",{"key":30,"text":149,"correct":25},"压缩机、冷凝器、蒸发器",{"id":151,"libraryId":5,"type":8,"typeLabel":15,"stem":152,"options":153,"answer":27,"analysis":32},922166,"按《民用建筑电气设计规范》(JGJ\u002FT16-92)要求，高压配电室内出线套管至屋外通道的路面的最小安全净距应为( )m。",[154,155,157,159],{"key":19,"text":135,"correct":21},{"key":23,"text":156,"correct":21},"3.5",{"key":27,"text":158,"correct":25},"4",{"key":30,"text":160,"correct":21},"4.5",{"id":162,"libraryId":5,"type":8,"typeLabel":15,"stem":163,"options":164,"answer":30,"analysis":32},922167,"对锅炉房的进出口有如下叙述，其中有误的( )。",[165,167,169,171],{"key":19,"text":166,"correct":21},"当锅炉房地面面积超过250㎡时，每层至少应有两个通向室外的出口，并设在相对的两侧",{"key":23,"text":168,"correct":21},"若各锅炉前操作面的总长(包括锅炉之间的通道在内)不超过12m的单层锅炉房，可只设一个出口(地下锅炉房除外)",{"key":27,"text":170,"correct":21},"锅炉房通向室外的门应向外开",{"key":30,"text":172,"correct":25},"锅炉房内的工作室或生活室等直接通向锅炉间的门，应朝工作室或生活室内开",{"id":174,"libraryId":5,"type":8,"typeLabel":15,"stem":175,"options":176,"answer":30,"analysis":32},922168,"计算供暖热负荷的目的是( )。",[177,179,181,183],{"key":19,"text":178,"correct":21},"确定设计方案",{"key":23,"text":180,"correct":21},"选择热源",{"key":27,"text":182,"correct":21},"选择供热设备",{"key":30,"text":184,"correct":25},"三者都有",{"id":186,"libraryId":5,"type":8,"typeLabel":15,"stem":187,"options":188,"answer":30,"analysis":32},922169,"室内用水有消防用水、淋浴用水、洗刷用水、锅炉用水，还有其他生活用水，当采用合并管道供水时，其供水管道中的流量计算是( )。",[189,191,193,195],{"key":19,"text":190,"correct":21},"各种用水量之和",{"key":23,"text":192,"correct":21},"只计消防用水量",{"key":27,"text":194,"correct":21},"只计锅炉用水量",{"key":30,"text":196,"correct":25},"淋浴用水量可按其计算用水量的15%计，洗刷用水量可不计算在内，其他均应计算在内",{"id":198,"libraryId":5,"type":8,"typeLabel":15,"stem":199,"options":200,"answer":27,"analysis":32},922170,"某淋浴室内有5个淋浴器，应设地漏的直径为( )mm。",[201,202,204,205],{"key":19,"text":38,"correct":21},{"key":23,"text":203,"correct":21},"75",{"key":27,"text":40,"correct":25},{"key":30,"text":206,"correct":21},"125",{"id":208,"libraryId":5,"type":8,"typeLabel":15,"stem":209,"options":210,"answer":30,"analysis":32},922171,"露天游泳池的池水温度为( )。",[211,213,215,217],{"key":19,"text":212,"correct":21},"不宜低于18℃",{"key":23,"text":214,"correct":21},"不宜低于19℃",{"key":27,"text":216,"correct":21},"不宜低于20℃",{"key":30,"text":218,"correct":25},"不宜低于22℃",{"id":220,"libraryId":5,"type":8,"typeLabel":15,"stem":221,"options":222,"answer":30,"analysis":32},922172,"水箱的有效容积，不应考虑的因素有( )。",[223,225,227,229],{"key":19,"text":224,"correct":21},"生产、生活调节水量",{"key":23,"text":226,"correct":21},"生活和消防贮备量",{"key":27,"text":228,"correct":21},"生产事故贮备量",{"key":30,"text":230,"correct":25},"热水供应所需水量",{"id":232,"libraryId":5,"type":8,"typeLabel":15,"stem":233,"options":234,"answer":27,"analysis":32},922173,"图中( )为高层建筑减压水箱减压的分区给水方式。",[235,236,237,238],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":21},{"id":240,"libraryId":5,"type":8,"typeLabel":15,"stem":241,"options":242,"answer":27,"analysis":32},922174,"以下叙述错误的是( )。",[243,245,247,249],{"key":19,"text":244,"correct":21},"生活排水管道的立管顶端应设伸顶通气管",{"key":23,"text":246,"correct":21},"散发有害气体的生活污水管道应设伸顶通气管",{"key":27,"text":248,"correct":25},"通气立管也可以接纳器具污水、废水和雨水",{"key":30,"text":250,"correct":21},"通气立管出屋面不得小于0.3m，且必须大于积雪厚度",{"id":252,"libraryId":5,"type":8,"typeLabel":15,"stem":253,"options":254,"answer":30,"analysis":32},922175,"决定照明器具的节能是下列( )参数值。",[255,257,259,261],{"key":19,"text":256,"correct":21},"光源的光效",{"key":23,"text":258,"correct":21},"灯具效率",{"key":27,"text":260,"correct":21},"照明的控制方式",{"key":30,"text":262,"correct":25},"照明功率密度值",{"id":264,"libraryId":5,"type":8,"typeLabel":15,"stem":265,"options":266,"answer":27,"analysis":32},922176,"庭院煤气管宜与建筑物轴线平行，管道距建筑物基础为( )。",[267,269,271,273],{"key":19,"text":268,"correct":21},"不小于l.Om",{"key":23,"text":270,"correct":21},"不小于1.5m",{"key":27,"text":272,"correct":25},"不小于2.Om",{"key":30,"text":274,"correct":21},"不小于2.5m",{"id":276,"libraryId":5,"type":8,"typeLabel":15,"stem":277,"options":278,"answer":23,"analysis":32},922177,"以下图示哪个不宜？( )",[279,280,281,282],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":25},{"key":27,"text":32,"correct":21},{"key":30,"text":32,"correct":21},{"id":284,"libraryId":5,"type":8,"typeLabel":15,"stem":285,"options":286,"answer":19,"analysis":32},922178,"控制电缆穿排管敷设时，管孔内径不应小于( )mm。",[287,288,290,292],{"key":19,"text":203,"correct":25},{"key":23,"text":289,"correct":21},"90",{"key":27,"text":291,"correct":21},"120",{"key":30,"text":42,"correct":21},{"id":294,"libraryId":5,"type":8,"typeLabel":15,"stem":295,"options":296,"answer":19,"analysis":32},922179,"旅馆建筑的消防控制室至各重要设备用房和旅馆主要负责人之间应设哪种通信方式( )。",[297,299,301,303],{"key":19,"text":298,"correct":25},"外线电话",{"key":23,"text":300,"correct":21},"值班电话",{"key":27,"text":302,"correct":21},"信号装置",{"key":30,"text":304,"correct":21},"对讲电话",{"id":306,"libraryId":5,"type":8,"typeLabel":15,"stem":307,"options":308,"answer":23,"analysis":32},922180,"不允许间断供水的建筑物内，应从室外管网不同来水管段至少设( )引入管。",[309,311,313,315],{"key":19,"text":310,"correct":21},"一条",{"key":23,"text":312,"correct":25},"两条",{"key":27,"text":314,"correct":21},"三条",{"key":30,"text":316,"correct":21},"四条",{"id":318,"libraryId":5,"type":8,"typeLabel":15,"stem":319,"options":320,"answer":27,"analysis":32},922181,"高层建筑技术层包括制冷机房、锅炉房等的层高大约为( )m。",[321,322,324,326],{"key":19,"text":158,"correct":21},{"key":23,"text":323,"correct":21},"2.2",{"key":27,"text":325,"correct":25},"4-6.5",{"key":30,"text":327,"correct":21},"＞6.5",{"id":329,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":330,"answer":27,"analysis":32},922182,[331,332,333,334],{"key":19,"text":38,"correct":21},{"key":23,"text":40,"correct":21},{"key":27,"text":42,"correct":25},{"key":30,"text":44,"correct":21},{"id":336,"libraryId":5,"type":8,"typeLabel":15,"stem":337,"options":338,"answer":23,"analysis":32},922183,"游泳池所设的平衡水池的有效容积，不应小于循环水系统的管道和过滤、加热设备的水容积之和，且不应小于循环水泵( )mⅠn的出水量。",[339,340,341,343],{"key":19,"text":133,"correct":21},{"key":23,"text":137,"correct":25},{"key":27,"text":342,"correct":21},"7l",{"key":30,"text":344,"correct":21},"10",{"id":346,"libraryId":5,"type":8,"typeLabel":15,"stem":347,"options":348,"answer":23,"analysis":32},922184,"在厂房内，地面为混凝土地面，其排水铸铁管的最小埋设深度，即地面距管顶的最小距离为( )m。",[349,351,353,355],{"key":19,"text":350,"correct":21},"0.3",{"key":23,"text":352,"correct":25},"0.4",{"key":27,"text":354,"correct":21},"0.5",{"key":30,"text":356,"correct":21},"0.6",{"id":358,"libraryId":5,"type":8,"typeLabel":15,"stem":359,"options":360,"answer":19,"analysis":32},922185,"消防控制室的接地电阻应符合的要求为( )。",[361,363,365,367],{"key":19,"text":362,"correct":25},"专设工作接地装置时其接地电阻应小于4Ω",{"key":23,"text":364,"correct":21},"专设工作接地装置时其接地电阻不应小于4Ω",{"key":27,"text":366,"correct":21},"采用联合接地时，接地电阻应小于2Ω",{"key":30,"text":368,"correct":21},"采用联合接地时，接地电阻不应小于2Ω",{"id":370,"libraryId":5,"type":8,"typeLabel":15,"stem":371,"options":372,"answer":27,"analysis":32},922186,"民用建筑的主要房间，其采暖温度宜采用( )。",[373,375,377,379],{"key":19,"text":374,"correct":21},"12℃-14℃",{"key":23,"text":376,"correct":21},"14℃-16℃",{"key":27,"text":378,"correct":25},"16℃～24℃",{"key":30,"text":380,"correct":21},"20℃-22℃",{"id":382,"libraryId":5,"type":8,"typeLabel":15,"stem":383,"options":384,"answer":27,"analysis":32},922187,"重力流雨水悬吊管检查口间距不宜大于( )m。",[385,386,388,390],{"key":19,"text":344,"correct":21},{"key":23,"text":387,"correct":21},"15",{"key":27,"text":389,"correct":25},"20",{"key":30,"text":391,"correct":21},"25",{"id":393,"libraryId":5,"type":8,"typeLabel":15,"stem":394,"options":395,"answer":19,"analysis":32},922188,"多台水泵共用吸水管时，吸水管连接应采用( )。",[396,398,400,402],{"key":19,"text":397,"correct":25},"管顶平接",{"key":23,"text":399,"correct":21},"水面平接",{"key":27,"text":401,"correct":21},"管底平接",{"key":30,"text":403,"correct":21},"管中心线平接",{"id":405,"libraryId":5,"type":8,"typeLabel":15,"stem":406,"options":407,"answer":27,"analysis":32},922189,"宾馆客房每床每日所使用60℃热水用水定额(最高日)为( )L。",[408,410,412,414],{"key":19,"text":409,"correct":21},"50-100",{"key":23,"text":411,"correct":21},"100-150",{"key":27,"text":413,"correct":25},"120～160",{"key":30,"text":415,"correct":21},"160～200",{"id":417,"libraryId":5,"type":8,"typeLabel":15,"stem":418,"options":419,"answer":30,"analysis":32},922190,"不宜做中水原水的是( )。",[420,422,424,426],{"key":19,"text":421,"correct":21},"冷却水、沐浴盥洗水、洗衣排水",{"key":23,"text":423,"correct":21},"厨房排水",{"key":27,"text":425,"correct":21},"厕所排水、雨水",{"key":30,"text":427,"correct":25},"医院污水和工业废水",{"id":429,"libraryId":5,"type":8,"typeLabel":15,"stem":430,"options":431,"answer":27,"analysis":32},922191,"在工程上制冷量经常以冷吨为计量单位，1冷吨(US，RT)接近于( )W。",[432,434,436,438],{"key":19,"text":433,"correct":21},"1500",{"key":23,"text":435,"correct":21},"2500",{"key":27,"text":437,"correct":25},"3500",{"key":30,"text":439,"correct":21},"4500",{"id":441,"libraryId":5,"type":8,"typeLabel":15,"stem":442,"options":443,"answer":27,"analysis":32},922192,"一般体育馆的空调系统的用电负荷属于( )负荷？",[444,446,448,450],{"key":19,"text":445,"correct":21},"一级",{"key":23,"text":447,"correct":21},"二级",{"key":27,"text":449,"correct":25},"三级",{"key":30,"text":451,"correct":21},"应急用电",{"id":453,"libraryId":5,"type":8,"typeLabel":15,"stem":454,"options":455,"answer":23,"analysis":32},922193,"幼儿园、托儿所的浴盆、淋浴器要求热水的温度是( )℃。",[456,458,460,462],{"key":19,"text":457,"correct":21},"30",{"key":23,"text":459,"correct":25},"35",{"key":27,"text":461,"correct":21},"37",{"key":30,"text":463,"correct":21},"40",{"id":465,"libraryId":5,"type":8,"typeLabel":15,"stem":466,"options":467,"answer":19,"analysis":32},922194,"散流器平送的送风方式，如果房间的面积较大，可采用几个散流器对称布置，对各散流器的安装要求是( )。",[468,470,472,474],{"key":19,"text":469,"correct":25},"各散流器的间距一般在3-6m，散流器的中心轴线距墙一般不小于1m",{"key":23,"text":471,"correct":21},"各散流器的间距一般在1-2m，散流器的中心轴线距墙一般不小于0.5m",{"key":27,"text":473,"correct":21},"各散流器的间距一般在3～4m，散流器的中心轴线距墙一般为2m",{"key":30,"text":475,"correct":21},"各散流器的间距一般为8m，散流器的中心轴线距墙一般为0.2m",{"id":477,"libraryId":5,"type":8,"typeLabel":15,"stem":478,"options":479,"answer":27,"analysis":32},922195,"下列对配变电所的设置要求中，( )是错误的。",[480,482,484,486],{"key":19,"text":481,"correct":21},"-类高层、低层主体建筑内，严禁设置装有可燃性油的设备",{"key":23,"text":483,"correct":21},"高层建筑中配变电所宜划为单独的防火分区",{"key":27,"text":485,"correct":25},"高、低压配电设备不可设在同一房间内",{"key":30,"text":487,"correct":21},"值班室应单独设置，但可与控制室或低压配电室合并兼用",{"id":489,"libraryId":5,"type":8,"typeLabel":15,"stem":490,"options":491,"answer":30,"analysis":32},922196,"溴化锂吸收式冷水机组的制冷剂是( )。",[492,494,496,498],{"key":19,"text":493,"correct":21},"R-22",{"key":23,"text":495,"correct":21},"R-123",{"key":27,"text":497,"correct":21},"R-134a",{"key":30,"text":499,"correct":25},"水",{"id":501,"libraryId":5,"type":8,"typeLabel":15,"stem":502,"options":503,"answer":30,"analysis":32},922197,"消火栓系统中消防给水管道的水流速度不宜大于( )m\u002Fs。",[504,506,508,510],{"key":19,"text":505,"correct":21},"1.0",{"key":23,"text":507,"correct":21},"1.5",{"key":27,"text":509,"correct":21},"2.0",{"key":30,"text":511,"correct":25},"2.5",{"id":513,"libraryId":5,"type":8,"typeLabel":15,"stem":514,"options":515,"answer":30,"analysis":32},922198,"能够代替1211卤代烷灭火剂的洁净气体不包括( )。",[516,518,520,522],{"key":19,"text":517,"correct":21},"三氟甲烷",{"key":23,"text":519,"correct":21},"七氟丙烷",{"key":27,"text":521,"correct":21},"惰性气体",{"key":30,"text":523,"correct":25},"卤代烷1301",{"id":525,"libraryId":5,"type":8,"typeLabel":15,"stem":526,"options":527,"answer":23,"analysis":32},922199,"夏季太阳辐射强度，应根据当地的地理纬度、大气透明度和大气压力，按太阳赤纬计算确定，其时间规定是( )。",[528,530,532,534],{"key":19,"text":529,"correct":21},"6月28日",{"key":23,"text":531,"correct":25},"7月21日",{"key":27,"text":533,"correct":21},"7月28日",{"key":30,"text":535,"correct":21},"8月16日",{"id":537,"libraryId":5,"type":8,"typeLabel":15,"stem":538,"options":539,"answer":19,"analysis":32},922200,"建筑内消防用水量大小确定的有关依据是( )。",[540,542,544,546],{"key":19,"text":541,"correct":25},"根据《健筑设计防火规范》(GB50016-2006)等消防规范确定",{"key":23,"text":543,"correct":21},"建筑高度",{"key":27,"text":545,"correct":21},"建筑体积",{"key":30,"text":547,"correct":21},"地区情况",{"id":549,"libraryId":5,"type":8,"typeLabel":15,"stem":550,"options":551,"answer":27,"analysis":32},922201,"集中供暖系统是由( )。",[552,554,556,558],{"key":19,"text":553,"correct":21},"热源与用户组成",{"key":23,"text":555,"correct":21},"热源与管网组成",{"key":27,"text":557,"correct":25},"热源、管网和用户组成",{"key":30,"text":559,"correct":21},"管网和用户组成",{"id":561,"libraryId":5,"type":8,"typeLabel":15,"stem":562,"options":563,"answer":30,"analysis":32},922202,"以下对室内敷线要求中错误的是( )。",[564,566,568,570],{"key":19,"text":565,"correct":21},"建筑物顶棚内，严禁采用直敷布线",{"key":23,"text":567,"correct":21},"当将导线直接埋入墙壁、顶棚抹灰层内时，必须采用护套绝缘电线",{"key":27,"text":569,"correct":21},"室内水平直敷布线时，对地距离不应小于2.5m",{"key":30,"text":571,"correct":25},"穿金属管的交流线路，应将同一回路的相线和中性线穿于同一根管内",{"id":573,"libraryId":5,"type":8,"typeLabel":15,"stem":574,"options":575,"answer":27,"analysis":32},922203,"生活给水管道内的水流速度不宜大于( )m\u002Fs。",[576,577,578,580],{"key":19,"text":505,"correct":21},{"key":23,"text":507,"correct":21},{"key":27,"text":579,"correct":25},"1.8",{"key":30,"text":511,"correct":21},{"id":582,"libraryId":5,"type":8,"typeLabel":15,"stem":583,"options":584,"answer":19,"analysis":32},922204,"按照散热器的承压能力，对于30m以下的建筑，应采用的系统是( )。",[585,587,589,591],{"key":19,"text":586,"correct":25},"应采用低区采暖系统，散热器采用低压散热器",{"key":23,"text":588,"correct":21},"应采用低区采暖系统，散热器采用高压散热器",{"key":27,"text":590,"correct":21},"应采用高、低区采暖系统，散热器采用低压散热器",{"key":30,"text":592,"correct":21},"应采用高、低区采暖系统，低区采用低压散热器，高区采用高压散热器",[594,597,600,603,607,609],{"id":8,"name":595,"category":7,"favorite":596},"领导干部任职前廉政法规知识测试题",92,{"id":598,"name":599,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":601,"name":602,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":604,"name":605,"category":7,"favorite":606},534,"BIM工程师",0,{"id":608,"name":605,"category":7,"favorite":606},535,{"id":610,"name":611,"category":7,"favorite":606},536,"安全人A证"]