[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-57":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,57,50,2979,[13,33,45,57,69,81,93,105,117,129,141,152,164,176,188,200,212,224,236,248,260,272,284,296,304,315,327,339,351,363,375,387,399,411,423,435,447,459,471,483,495,506,514,526,538,550,562,574,586,598],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":29,"analysis":32},922055,"单选题","-类高层建筑和建筑高度超过32m的二类高层建筑的内走道，长度在( )范围内可设自然排烟，超过此范围应设机械排烟。",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","超过20m",false,{"key":23,"text":24,"correct":21},"B","超过20m但没超过32m",{"key":26,"text":27,"correct":21},"C","超过20m但没超过60m",{"key":29,"text":30,"correct":31},"D","60m",true,"",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":35,"options":36,"answer":19,"analysis":32},922056,"穿过防火墙两侧各2m范围内的风管，其材料应为( )。",[37,39,41,43],{"key":19,"text":38,"correct":31},"非燃烧材料",{"key":23,"text":40,"correct":21},"难燃烧材料",{"key":26,"text":42,"correct":21},"无要求",{"key":29,"text":44,"correct":21},"两侧各1m范围内为非燃烧材料，其余为难燃烧材料",{"id":46,"libraryId":5,"type":8,"typeLabel":15,"stem":47,"options":48,"answer":26,"analysis":32},922057,"水景喷水池的深度应根据喷头形式、数量、配水管管径、施工安装的使用要求确定，还应保证水下灯顶到水面有( )的保护高度。",[49,51,53,55],{"key":19,"text":50,"correct":21},"≮0.3m",{"key":23,"text":52,"correct":21},"≮0.4m",{"key":26,"text":54,"correct":31},"≮0.5m",{"key":29,"text":56,"correct":21},"≮0.6m",{"id":58,"libraryId":5,"type":8,"typeLabel":15,"stem":59,"options":60,"answer":26,"analysis":32},922058,"民用建筑的供电在用电设备容量和变压器容量分别为( )时，采用高压方式供电。",[61,63,65,67],{"key":19,"text":62,"correct":21},"50kW和40kⅤA以上",{"key":23,"text":64,"correct":21},"100kW和80kⅤA以上",{"key":26,"text":66,"correct":31},"250kW和160kⅤA以上",{"key":29,"text":68,"correct":21},"500kW和300kⅤA以上",{"id":70,"libraryId":5,"type":8,"typeLabel":15,"stem":71,"options":72,"answer":26,"analysis":32},922059,"某宾馆热水供应采用容积式换热器，热源为蒸汽，则贮水器的贮热量为( )。",[73,75,77,79],{"key":19,"text":74,"correct":21},"不得小于15mⅠn的设计小时耗热量",{"key":23,"text":76,"correct":21},"不得小于30Ⅰrun的设计小时耗热量",{"key":26,"text":78,"correct":31},"不得小于45mⅠn的设计小时耗热量",{"key":29,"text":80,"correct":21},"不得小于60mⅠn的设计小时耗热量",{"id":82,"libraryId":5,"type":8,"typeLabel":15,"stem":83,"options":84,"answer":26,"analysis":32},922060,"下列建筑中，( )可以不设置消防水泵接合器。",[85,87,89,91],{"key":19,"text":86,"correct":21},"高层厂房(仓库)",{"key":23,"text":88,"correct":21},"设有消火栓且超过4层的厂房(仓库)",{"key":26,"text":90,"correct":31},"设有消火栓的多层住宅",{"key":29,"text":92,"correct":21},"设有消火栓且超过5层的公共建筑",{"id":94,"libraryId":5,"type":8,"typeLabel":15,"stem":95,"options":96,"answer":23,"analysis":32},922061,"平衡水池应设与游泳池相连接的连通管，连通管可与回水管合并设置，平衡水池底内表面宜低于最低回水管以下( )rnm。",[97,99,101,103],{"key":19,"text":98,"correct":21},"200-400",{"key":23,"text":100,"correct":31},"400-700",{"key":26,"text":102,"correct":21},"800",{"key":29,"text":104,"correct":21},"1000",{"id":106,"libraryId":5,"type":8,"typeLabel":15,"stem":107,"options":108,"answer":23,"analysis":32},922062,"某高度大于50m的二类图书馆，其室外消火栓数为( )个。",[109,111,113,115],{"key":19,"text":110,"correct":21},"1",{"key":23,"text":112,"correct":31},"2",{"key":26,"text":114,"correct":21},"3",{"key":29,"text":116,"correct":21},"4",{"id":118,"libraryId":5,"type":8,"typeLabel":15,"stem":119,"options":120,"answer":29,"analysis":32},922063,"塑料排水立管上的检查口设置方法错误的是( )。",[121,123,125,127],{"key":19,"text":122,"correct":21},"中间每6层",{"key":23,"text":124,"correct":21},"底层、最高层",{"key":26,"text":126,"correct":21},"乙字管或水平拐弯的上部",{"key":29,"text":128,"correct":31},"每一层",{"id":130,"libraryId":5,"type":8,"typeLabel":15,"stem":131,"options":132,"answer":26,"analysis":32},922064,"采暖期室外平均温度低于-5℃的地区，建筑物外墙在室外地坪以下的垂直墙面，以及周边直接接触土壤的地面应采取保温措施，在外墙周边从外墙内侧算起2m范围内，地面的传热系数是( )W\u002F(㎡·K)。",[133,135,137,139],{"key":19,"text":134,"correct":21},"≯0.2",{"key":23,"text":136,"correct":21},"≯0.25",{"key":26,"text":138,"correct":31},"≯0.30",{"key":29,"text":140,"correct":21},"≯0.35",{"id":142,"libraryId":5,"type":8,"typeLabel":15,"stem":143,"options":144,"answer":23,"analysis":32},922065,"安装燃气灶的房间净高不得低于( )m。",[145,146,148,150],{"key":19,"text":112,"correct":21},{"key":23,"text":147,"correct":31},"2.2",{"key":26,"text":149,"correct":21},"2.4",{"key":29,"text":151,"correct":21},"2.6",{"id":153,"libraryId":5,"type":8,"typeLabel":15,"stem":154,"options":155,"answer":23,"analysis":32},922066,"以下关于污水处理的叙述错误的是( )。",[156,158,160,162],{"key":19,"text":157,"correct":21},"锅炉排水温度高于40℃时排入下水道前应该进行降温处理",{"key":23,"text":159,"correct":31},"医院传染科污水应该进行消毒处理",{"key":26,"text":161,"correct":21},"粪便污水和其他污水不得排入隔油井内",{"key":29,"text":163,"correct":21},"为截留汽车修理间和其他少量生产污水中的油类应该设置隔油井",{"id":165,"libraryId":5,"type":8,"typeLabel":15,"stem":166,"options":167,"answer":19,"analysis":32},922067,"高级旅馆的客房内，宜采用的空调方式为( )。",[168,170,172,174],{"key":19,"text":169,"correct":31},"风机盘管+新风系统",{"key":23,"text":171,"correct":21},"风机盘管系统",{"key":26,"text":173,"correct":21},"全空气空调系统",{"key":29,"text":175,"correct":21},"全新风直流系统",{"id":177,"libraryId":5,"type":8,"typeLabel":15,"stem":178,"options":179,"answer":19,"analysis":32},922068,"医院污水排入城市下水道时，宜采用( )。",[180,182,184,186],{"key":19,"text":181,"correct":31},"一级处理",{"key":23,"text":183,"correct":21},"二级处理",{"key":26,"text":185,"correct":21},"三级处理",{"key":29,"text":187,"correct":21},"不处理",{"id":189,"libraryId":5,"type":8,"typeLabel":15,"stem":190,"options":191,"answer":26,"analysis":32},922069,"关于生活饮用水水池的设置规定，下列哪项是错误的？( )",[192,194,196,198],{"key":19,"text":193,"correct":21},"建筑屋内的生活饮用水水池体，不得利用建筑物的本体结构作为水池的壁板、底板及顶盖",{"key":23,"text":195,"correct":21},"生活饮用水水池与其他用水水池并列设置时，应有各自独立的分隔墙，隔墙与隔墙之间考虑排水设施",{"key":26,"text":197,"correct":31},"埋地式生活饮用水水池周围8m以内，不得有化粪池",{"key":29,"text":199,"correct":21},"建筑物内生活饮用水水池上方的房间不应有厕所、浴室、厨房、污水处理间等",{"id":201,"libraryId":5,"type":8,"typeLabel":15,"stem":202,"options":203,"answer":23,"analysis":32},922070,"高层丙类厂房宜设的消防系统是( )。",[204,206,208,210],{"key":19,"text":205,"correct":21},"蒸汽灭火系统",{"key":23,"text":207,"correct":31},"自动喷水灭火系统",{"key":26,"text":209,"correct":21},"二氧化碳灭火系统",{"key":29,"text":211,"correct":21},"雨淋灭火系统",{"id":213,"libraryId":5,"type":8,"typeLabel":15,"stem":214,"options":215,"answer":19,"analysis":32},922071,"高级居住建筑、办公建筑和医疗卫生及托幼建筑等，散热器采暖系统的热媒温度为( )。",[216,218,220,222],{"key":19,"text":217,"correct":31},"95℃",{"key":23,"text":219,"correct":21},"110℃",{"key":26,"text":221,"correct":21},"30℃",{"key":29,"text":223,"correct":21},"120℃",{"id":225,"libraryId":5,"type":8,"typeLabel":15,"stem":226,"options":227,"answer":23,"analysis":32},922072,"防直击雷接地( )和防雷电感应、电气设备、信息系统等接地，( )共用同一接地装置，与埋地金属管道相连。",[228,230,232,234],{"key":19,"text":229,"correct":21},"应、应",{"key":23,"text":231,"correct":31},"宜、宜",{"key":26,"text":233,"correct":21},"应、宜",{"key":29,"text":235,"correct":21},"宜、应",{"id":237,"libraryId":5,"type":8,"typeLabel":15,"stem":238,"options":239,"answer":23,"analysis":32},922073,"通风、空气调节系统风管，当采用矩形风管时，其短、长边之比不宜大于( )。",[240,242,244,246],{"key":19,"text":241,"correct":21},"1：3",{"key":23,"text":243,"correct":31},"1：4",{"key":26,"text":245,"correct":21},"1：15",{"key":29,"text":247,"correct":21},"1：20",{"id":249,"libraryId":5,"type":8,"typeLabel":15,"stem":250,"options":251,"answer":19,"analysis":32},922074,"计算低温热水地板辐射供暖的热负荷时，将室内温度取值降低2℃，是因为( )。",[252,254,256,258],{"key":19,"text":253,"correct":31},"低温热水地板辐射采暖用于全面采暖时，在相同热舒适条件下的室内温度可比对流采暖时的室内温度低2℃",{"key":23,"text":255,"correct":21},"地板辐射采暖效率高",{"key":26,"text":257,"correct":21},"地板辐射采暖散热面积大",{"key":29,"text":259,"correct":21},"地板辐射采暖水温低",{"id":261,"libraryId":5,"type":8,"typeLabel":15,"stem":262,"options":263,"answer":19,"analysis":32},922075,"在正常环境下，人身电击安全交流电压限值为( )Ⅴ。",[264,266,268,270],{"key":19,"text":265,"correct":31},"50",{"key":23,"text":267,"correct":21},"36",{"key":26,"text":269,"correct":21},"24",{"key":29,"text":271,"correct":21},"75",{"id":273,"libraryId":5,"type":8,"typeLabel":15,"stem":274,"options":275,"answer":29,"analysis":32},922076,"消防水泵的吸水管中有l条关闭时，其余的吸水管应能通过全部用水量的( )。",[276,278,280,282],{"key":19,"text":277,"correct":21},"50%",{"key":23,"text":279,"correct":21},"70%",{"key":26,"text":281,"correct":21},"75%",{"key":29,"text":283,"correct":31},"100%",{"id":285,"libraryId":5,"type":8,"typeLabel":15,"stem":286,"options":287,"answer":26,"analysis":32},922077,"高层民用建筑应设置独立的机械加压送风防烟设施的部位，下列( )应除外。",[288,290,292,294],{"key":19,"text":289,"correct":21},"不具备自然排烟条件的防烟楼梯间、消防电梯前室或合用前室",{"key":23,"text":291,"correct":21},"采用自然排烟设施的防烟楼梯间，其不具备自然排烟条件的前室",{"key":26,"text":293,"correct":31},"开敞式避难层",{"key":29,"text":295,"correct":21},"封闭式避难层",{"id":297,"libraryId":5,"type":8,"typeLabel":15,"stem":298,"options":299,"answer":23,"analysis":32},922078,"室外消火栓距路边不应超过( )m。",[300,301,302,303],{"key":19,"text":110,"correct":21},{"key":23,"text":112,"correct":31},{"key":26,"text":114,"correct":21},{"key":29,"text":116,"correct":21},{"id":305,"libraryId":5,"type":8,"typeLabel":15,"stem":306,"options":307,"answer":23,"analysis":32},922079,"室外消防给水管道的最小直径不应小于( )mm。",[308,309,311,313],{"key":19,"text":265,"correct":21},{"key":23,"text":310,"correct":31},"100",{"key":26,"text":312,"correct":21},"150",{"key":29,"text":314,"correct":21},"175",{"id":316,"libraryId":5,"type":8,"typeLabel":15,"stem":317,"options":318,"answer":26,"analysis":32},922080,"变压器室宜采用自然通风，进风和排风的温差不宜大于( )。",[319,321,323,325],{"key":19,"text":320,"correct":21},"25℃",{"key":23,"text":322,"correct":21},"20℃",{"key":26,"text":324,"correct":31},"15℃",{"key":29,"text":326,"correct":21},"10℃",{"id":328,"libraryId":5,"type":8,"typeLabel":15,"stem":329,"options":330,"answer":23,"analysis":32},922081,"下述有关电气竖井布置的要求中，( )是错误的。",[331,333,335,337],{"key":19,"text":332,"correct":21},"应靠近负荷中心和配变电所，以减少线路长度",{"key":23,"text":334,"correct":31},"应尽量与其他管井合用以降低投资",{"key":26,"text":336,"correct":21},"应远离烟道、热力管道等设施",{"key":29,"text":338,"correct":21},"应尽量避免与楼梯间和电梯井相邻",{"id":340,"libraryId":5,"type":8,"typeLabel":15,"stem":341,"options":342,"answer":29,"analysis":32},922082,"以下热水供应系统按热水管网循环方式分类，其中( )说法是错误的。",[343,345,347,349],{"key":19,"text":344,"correct":21},"不循环热水供应系统",{"key":23,"text":346,"correct":21},"半循环热水供应系统",{"key":26,"text":348,"correct":21},"全循环热水供应系统",{"key":29,"text":350,"correct":31},"强制循环热水供应系统",{"id":352,"libraryId":5,"type":8,"typeLabel":15,"stem":353,"options":354,"answer":23,"analysis":32},922083,"下列关于饮用净水错误的是( )。",[355,357,359,361],{"key":19,"text":356,"correct":21},"宜用市政水",{"key":23,"text":358,"correct":31},"应用湖泊水",{"key":26,"text":360,"correct":21},"要深度处理",{"key":29,"text":362,"correct":21},"符合《饮用净水水质标准》",{"id":364,"libraryId":5,"type":8,"typeLabel":15,"stem":365,"options":366,"answer":26,"analysis":32},922084,"何种制冷机房不得布置在民用建筑和工业企业辅助建筑物内？( )",[367,369,371,373],{"key":19,"text":368,"correct":21},"溴化锂吸收式制冷机",{"key":23,"text":370,"correct":21},"氟利昂活塞式制冷机",{"key":26,"text":372,"correct":31},"氨压缩式制冷机",{"key":29,"text":374,"correct":21},"氟利昂离心式制冷机",{"id":376,"libraryId":5,"type":8,"typeLabel":15,"stem":377,"options":378,"answer":26,"analysis":32},922085,"关于供电回路不正确的说法是( )。",[379,381,383,385],{"key":19,"text":380,"correct":21},"每一单相回路不宜超过16 A，单灯灯具不宜超过25个",{"key":23,"text":382,"correct":21},"大型建筑组合灯具每一单相回路不宜超过25灯泡数量不宜超过60个",{"key":26,"text":384,"correct":31},"建筑轮廓灯每一单相回路不宜超过200个",{"key":29,"text":386,"correct":21},"每回路的插座数不宜超过10个",{"id":388,"libraryId":5,"type":8,"typeLabel":15,"stem":389,"options":390,"answer":29,"analysis":32},922086,"综合布线系统由( )组成。Ⅰ.工作区子系统；Ⅱ，水平子系统、干线子系统；Ⅲ.设备间子系统、建筑群子系统；Ⅳ.管理区子系统",[391,393,395,397],{"key":19,"text":392,"correct":21},"Ⅰ、Ⅱ、Ⅲ",{"key":23,"text":394,"correct":21},"Ⅱ、Ⅲ、Ⅳ",{"key":26,"text":396,"correct":21},"Ⅰ、Ⅱ、Ⅳ",{"key":29,"text":398,"correct":31},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"id":400,"libraryId":5,"type":8,"typeLabel":15,"stem":401,"options":402,"answer":29,"analysis":32},922087,"下列场所宜选择点型感烟探测器的是( )。",[403,405,407,409],{"key":19,"text":404,"correct":21},"办公室、电子计算机房、发电机房",{"key":23,"text":406,"correct":21},"办公室、电子计算机房、汽车库",{"key":26,"text":408,"correct":21},"楼梯、走道、厨房",{"key":29,"text":410,"correct":31},"教学楼、通讯机房、书库",{"id":412,"libraryId":5,"type":8,"typeLabel":15,"stem":413,"options":414,"answer":29,"analysis":32},922088,"地下室设有大型制冷机房时，制冷机的出入问题，应优先考虑的方案是( )。",[415,417,419,421],{"key":19,"text":416,"correct":21},"室内楼板留吊装孔",{"key":23,"text":418,"correct":21},"电梯搬运",{"key":26,"text":420,"correct":21},"不考虑搬出，施工时提前搬入",{"key":29,"text":422,"correct":31},"外墙留孔，室外留出入口",{"id":424,"libraryId":5,"type":8,"typeLabel":15,"stem":425,"options":426,"answer":26,"analysis":32},922089,"某建筑小区采用水池_水泵-水箱联合供水方式，该水池有效容积为消防贮水量和生活调节水量之和。近年来，由于用水量增加，致使水池水量满足不了生活用水要求，要改变这种现状采用以下方法不妥的是( )。",[427,429,431,433],{"key":19,"text":428,"correct":21},"增大贮水池容积",{"key":23,"text":430,"correct":21},"增大贮水池进口管径",{"key":26,"text":432,"correct":31},"动用消防贮水量",{"key":29,"text":434,"correct":21},"既增大贮水池容积，又增大贮水池进水管管径",{"id":436,"libraryId":5,"type":8,"typeLabel":15,"stem":437,"options":438,"answer":19,"analysis":32},922090,"采用电力电容器做无功补偿宜采用的原则是( )。",[439,441,443,445],{"key":19,"text":440,"correct":31},"就地补偿",{"key":23,"text":442,"correct":21},"在变电所内集中补偿",{"key":26,"text":444,"correct":21},"在低压侧补偿",{"key":29,"text":446,"correct":21},"在高压侧补偿",{"id":448,"libraryId":5,"type":8,"typeLabel":15,"stem":449,"options":450,"answer":29,"analysis":32},922091,"医院供应热水不得采用的加热方式为( )。",[451,453,455,457],{"key":19,"text":452,"correct":21},"燃油锅炉",{"key":23,"text":454,"correct":21},"板式换热器",{"key":26,"text":456,"correct":21},"电加热器",{"key":29,"text":458,"correct":31},"有滞水区的容积式加热器Ⅰ鳞麟医院建筑不得采用有滞水区的容积式加热器，以免细菌繁殖。",{"id":460,"libraryId":5,"type":8,"typeLabel":15,"stem":461,"options":462,"answer":29,"analysis":32},922092,"下列住宅可不设建筑消火栓给水系统的是( )。",[463,465,467,469],{"key":19,"text":464,"correct":21},"超过7层的塔式住宅",{"key":23,"text":466,"correct":21},"超过7层的通廊式住宅",{"key":26,"text":468,"correct":21},"超过7层的单元式住宅",{"key":29,"text":470,"correct":31},"6-7层的单元式住宅",{"id":472,"libraryId":5,"type":8,"typeLabel":15,"stem":473,"options":474,"answer":26,"analysis":32},922093,"某机场建筑物设置消火栓系统的条件是( )。",[475,477,479,481],{"key":19,"text":476,"correct":21},"座位超过800个",{"key":23,"text":478,"correct":21},"座位超过1200个",{"key":26,"text":480,"correct":31},"体积超过5000m3",{"key":29,"text":482,"correct":21},"体积超过2000m3",{"id":484,"libraryId":5,"type":8,"typeLabel":15,"stem":485,"options":486,"answer":29,"analysis":32},922094,"自流入排水管内的污、废水是在非满流情况下排除，其上部未充满水流的空间的作用如下，其中不正确的是( )。",[487,489,491,493],{"key":19,"text":488,"correct":21},"使污、废水中有害气体能自由向空间分离排出",{"key":23,"text":490,"correct":21},"调节排水管系统内压力的波动，从而防止卫生器具水封的破坏",{"key":26,"text":492,"correct":21},"容纳管道中超设计的高峰流量",{"key":29,"text":494,"correct":31},"使管道不承压，有利于管道的保护",{"id":496,"libraryId":5,"type":8,"typeLabel":15,"stem":497,"options":498,"answer":23,"analysis":32},922095,"住宅户内单相插座回路宜采用漏电电流( )mA的漏电保护开关。",[499,501,503,504],{"key":19,"text":500,"correct":21},"15",{"key":23,"text":502,"correct":31},"30",{"key":26,"text":310,"correct":21},{"key":29,"text":505,"correct":21},"300",{"id":507,"libraryId":5,"type":8,"typeLabel":15,"stem":508,"options":509,"answer":26,"analysis":32},922096,"某住宅采用水池→水泵→水箱给水方式，管路图示为上行下给式，水箱设在屋面上，从下图分析，( )水箱位置为佳。",[510,511,512,513],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":31},{"key":29,"text":32,"correct":21},{"id":515,"libraryId":5,"type":8,"typeLabel":15,"stem":516,"options":517,"answer":19,"analysis":32},922097,"建筑物处于规划设计阶段时，不能用于热负荷估算的方法是( )。",[518,520,522,524],{"key":19,"text":519,"correct":31},"稳定传热法",{"key":23,"text":521,"correct":21},"概算指标法",{"key":26,"text":523,"correct":21},"体积热指标法",{"key":29,"text":525,"correct":21},"面积热指标法",{"id":527,"libraryId":5,"type":8,"typeLabel":15,"stem":528,"options":529,"answer":19,"analysis":32},922098,"当室外管网服务水头始终大于室内所需的压力时，应采取( )。",[530,532,534,536],{"key":19,"text":531,"correct":31},"直接供水方式",{"key":23,"text":533,"correct":21},"单设水箱供水方式",{"key":26,"text":535,"correct":21},"单设水泵供水方式",{"key":29,"text":537,"correct":21},"设置水泵和水箱联合工作的供水方式",{"id":539,"libraryId":5,"type":8,"typeLabel":15,"stem":540,"options":541,"answer":23,"analysis":32},922099,"住宅区地面排水坡度不应小于( )。",[542,544,546,548],{"key":19,"text":543,"correct":21},"O.1%",{"key":23,"text":545,"correct":31},"0.2%",{"key":26,"text":547,"correct":21},"0.3%",{"key":29,"text":549,"correct":21},"0.4%",{"id":551,"libraryId":5,"type":8,"typeLabel":15,"stem":552,"options":553,"answer":29,"analysis":32},922100,"灯具与图书等易燃物的距离应大于( )m。",[554,556,558,560],{"key":19,"text":555,"correct":21},"O.l",{"key":23,"text":557,"correct":21},"0.2",{"key":26,"text":559,"correct":21},"0.3",{"key":29,"text":561,"correct":31},"0.5",{"id":563,"libraryId":5,"type":8,"typeLabel":15,"stem":564,"options":565,"answer":19,"analysis":32},922101,"门诊部、诊疗所热水用水定额单位是( )。",[566,568,570,572],{"key":19,"text":567,"correct":31},"每病人每次",{"key":23,"text":569,"correct":21},"每病床每日",{"key":26,"text":571,"correct":21},"每人每次",{"key":29,"text":573,"correct":21},"用水器具数",{"id":575,"libraryId":5,"type":8,"typeLabel":15,"stem":576,"options":577,"answer":29,"analysis":32},922102,"高层民用建筑的排烟口应设在防烟分区的( )。",[578,580,582,584],{"key":19,"text":579,"correct":21},"地面上",{"key":23,"text":581,"correct":21},"墙面上",{"key":26,"text":583,"correct":21},"靠近地面的墙面上",{"key":29,"text":585,"correct":31},"靠近顶棚的墙面上或顶棚上",{"id":587,"libraryId":5,"type":8,"typeLabel":15,"stem":588,"options":589,"answer":26,"analysis":32},922103,"锅炉房泄压面积不小于锅炉间占地面积的( )。",[590,592,594,596],{"key":19,"text":591,"correct":21},"2%",{"key":23,"text":593,"correct":21},"5%",{"key":26,"text":595,"correct":31},"10%",{"key":29,"text":597,"correct":21},"20%",{"id":599,"libraryId":5,"type":8,"typeLabel":15,"stem":600,"options":601,"answer":29,"analysis":32},922104,"以下几种二类防雷的建筑物中，不合规范要求的是( )。",[602,604,606,608],{"key":19,"text":603,"correct":21},"国家级的办公楼",{"key":23,"text":605,"correct":21},"大型铁路旅客站",{"key":26,"text":607,"correct":21},"国家级重点文物保护的建筑物",{"key":29,"text":609,"correct":31},"高度超过50m的建筑物",[611,614,617,620,624,626],{"id":8,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":618,"name":619,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":621,"name":622,"category":7,"favorite":623},534,"BIM工程师",0,{"id":625,"name":622,"category":7,"favorite":623},535,{"id":627,"name":628,"category":7,"favorite":623},536,"安全人A证"]