[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-56":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":591},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,56,50,2979,[13,33,45,55,67,79,91,103,115,127,139,151,163,175,183,195,207,216,228,239,248,260,272,284,296,308,320,332,340,352,361,373,385,397,408,420,432,440,452,464,476,487,499,511,523,535,544,556,568,580],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":29,"analysis":32},922005,"单选题","照明节能措施不应( )。",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","应用优化照明设计方法",false,{"key":23,"text":24,"correct":21},"B","采用节能照明装置",{"key":26,"text":27,"correct":21},"C","改进及合理选择照明控制",{"key":29,"text":30,"correct":31},"D","减少照明灯具",true,"",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":35,"options":36,"answer":19,"analysis":32},922006,"高层民用建筑靠外墙的防烟楼梯间每五层内可开启外窗面积之和不应小于( )㎡。",[37,39,41,43],{"key":19,"text":38,"correct":31},"2",{"key":23,"text":40,"correct":21},"3",{"key":26,"text":42,"correct":21},"5",{"key":29,"text":44,"correct":21},"10",{"id":46,"libraryId":5,"type":8,"typeLabel":15,"stem":47,"options":48,"answer":19,"analysis":32},922007,"新风口的面积应能满足系统总风量的( )要求。",[49,51,53],{"key":19,"text":50,"correct":31},"100%",{"key":23,"text":52,"correct":21},"50%",{"key":26,"text":54,"correct":21},"30%",{"id":56,"libraryId":5,"type":8,"typeLabel":15,"stem":57,"options":58,"answer":19,"analysis":32},922008,"当火灾探测器动作后，防火卷帘应一步下降到底，这种控制要求适用于以下( )项的情况。",[59,61,63,65],{"key":19,"text":60,"correct":31},"汽车库防火卷帘",{"key":23,"text":62,"correct":21},"疏散通道上的卷帘",{"key":26,"text":64,"correct":21},"各种类型卷帘",{"key":29,"text":66,"correct":21},"这种控制是错误的",{"id":68,"libraryId":5,"type":8,"typeLabel":15,"stem":69,"options":70,"answer":26,"analysis":32},922009,"依据《建筑设计防火规范》(GB50016-2006)，油浸电力变压器布置满足条件的是( )。",[71,73,75,77],{"key":19,"text":72,"correct":21},"人员密集场所的上方",{"key":23,"text":74,"correct":21},"贴邻疏散出口的两侧",{"key":26,"text":76,"correct":31},"总容量不应大于1260kⅤA",{"key":29,"text":78,"correct":21},"配变电所出口朝向走廊的任意一层",{"id":80,"libraryId":5,"type":8,"typeLabel":15,"stem":81,"options":82,"answer":29,"analysis":32},922010,"热水供应系统选择的依据是( )。",[83,85,87,89],{"key":19,"text":84,"correct":21},"管材、原水水质",{"key":23,"text":86,"correct":21},"热水量",{"key":26,"text":88,"correct":21},"热水水温",{"key":29,"text":90,"correct":31},"使用要求、耗热量、用水点分布情况、热源条件等",{"id":92,"libraryId":5,"type":8,"typeLabel":15,"stem":93,"options":94,"answer":23,"analysis":32},922011,"在下列房间中，应设单独排风系统的是( )。",[95,97,99,101],{"key":19,"text":96,"correct":21},"散发余热、余湿的房间",{"key":23,"text":98,"correct":31},"放散剧毒物质的房间及含有两种及两种以上有害物质混合后能引起燃烧或爆炸的房间",{"key":26,"text":100,"correct":21},"设有空调系统的地下室房间",{"key":29,"text":102,"correct":21},"设有空调的办公楼",{"id":104,"libraryId":5,"type":8,"typeLabel":15,"stem":105,"options":106,"answer":26,"analysis":32},922012,"跳水游泳池的水面波纹水浪的浪高宜为( )mm。",[107,109,111,113],{"key":19,"text":108,"correct":21},"10-15",{"key":23,"text":110,"correct":21},"15-20",{"key":26,"text":112,"correct":31},"25-40",{"key":29,"text":114,"correct":21},"45-60",{"id":116,"libraryId":5,"type":8,"typeLabel":15,"stem":117,"options":118,"answer":29,"analysis":32},922013,"高层建筑应设水喷雾灭火系统的部位，以下错误的是( )。",[119,121,123,125],{"key":19,"text":120,"correct":21},"可燃油油浸变压器室",{"key":23,"text":122,"correct":21},"充可燃油的高压电容器室",{"key":26,"text":124,"correct":21},"多油开关室",{"key":29,"text":126,"correct":31},"可燃物库房",{"id":128,"libraryId":5,"type":8,"typeLabel":15,"stem":129,"options":130,"answer":26,"analysis":32},922014,"当梁、通风管道等障碍物的宽度大于( )m时，在其下方增设喷头。",[131,133,135,137],{"key":19,"text":132,"correct":21},"0.8",{"key":23,"text":134,"correct":21},"1.0",{"key":26,"text":136,"correct":31},"1.2",{"key":29,"text":138,"correct":21},"1.5",{"id":140,"libraryId":5,"type":8,"typeLabel":15,"stem":141,"options":142,"answer":23,"analysis":32},922015,"民用建筑(潮湿的公共建筑除外)当室内外温差( )时，其外窗、阳台门均应采用双层。",[143,145,147,149],{"key":19,"text":144,"correct":21},"＜33℃",{"key":23,"text":146,"correct":31},"≥33℃",{"key":26,"text":148,"correct":21},"＜30℃",{"key":29,"text":150,"correct":21},"≥30℃",{"id":152,"libraryId":5,"type":8,"typeLabel":15,"stem":153,"options":154,"answer":26,"analysis":32},922016,"依据《人民防空工程设计防火规范》(GB50098-98)，下列说法错误的是( )。",[155,157,159,161],{"key":19,"text":156,"correct":21},"建筑面积小于或等于5000rrⅠ2的人防工程可按二级负荷要求供电",{"key":23,"text":158,"correct":21},"火灾疏散照明和火灾备用照明可采用蓄电池做备用电源，其连续供电时间不应小于30mⅠn",{"key":26,"text":160,"correct":31},"消防控制室、消防水泵、消防电梯、防烟风机、排烟风机等消防用电设备应采用两路电源或两回路线路供电，并应在最末一级配电箱处手动切换",{"key":29,"text":162,"correct":21},"当采用柴油发电机组做备用电源时，应设置自动启动装置，并能在30s内供电",{"id":164,"libraryId":5,"type":8,"typeLabel":15,"stem":165,"options":166,"answer":19,"analysis":32},922017,"在下述关于电缆敷设的叙述中，( )是错误的。",[167,169,171,173],{"key":19,"text":168,"correct":31},"电缆在室外直接埋地敷设的深度不应小于800mm",{"key":23,"text":170,"correct":21},"电缆敷设时，穿管内径不应小于电缆外径的1-5倍",{"key":26,"text":172,"correct":21},"电缆隧道两个出口间的距离超过75m时，应增加出口",{"key":29,"text":174,"correct":21},"电缆隧道内的净高不应低于1.9m",{"id":176,"libraryId":5,"type":8,"typeLabel":15,"stem":177,"options":178,"answer":26,"analysis":32},922018,"室外给水地下管道埋设深度的要求，以下图示错误的是( )。",[179,180,181,182],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":31},{"key":29,"text":32,"correct":21},{"id":184,"libraryId":5,"type":8,"typeLabel":15,"stem":185,"options":186,"answer":29,"analysis":32},922019,"智能建筑一般应包括( )。Ⅰ.办公自动化Ⅱ.设备自动化Ⅲ.通信自动化Ⅳ.综合布线",[187,189,191,193],{"key":19,"text":188,"correct":21},"Ⅰ、Ⅱ",{"key":23,"text":190,"correct":21},"Ⅰ、Ⅱ、Ⅳ",{"key":26,"text":192,"correct":21},"Ⅰ、Ⅱ、Ⅲ",{"key":29,"text":194,"correct":31},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"id":196,"libraryId":5,"type":8,"typeLabel":15,"stem":197,"options":198,"answer":26,"analysis":32},922020,"火灾自动报警系统保护对象应根据其( )分为特级、一级和二级。Ⅰ.使用性质；Ⅱ.重要性、火灾时的危险性；Ⅲ。火灾危险性；Ⅳ.疏散和扑救难度",[199,201,203,205],{"key":19,"text":200,"correct":21},"Ⅰ、Ⅲ",{"key":23,"text":202,"correct":21},"Ⅰ、Ⅳ",{"key":26,"text":204,"correct":31},"Ⅰ、Ⅲ、Ⅳ",{"key":29,"text":206,"correct":21},"Ⅱ、Ⅳ",{"id":208,"libraryId":5,"type":8,"typeLabel":15,"stem":209,"options":210,"answer":29,"analysis":32},922021,"当有哪些下列情况时，室外配电线路应采用电缆？( )Ⅰ.重点风景旅游区的建筑群Ⅱ.环境对架空线路有严重腐蚀时Ⅲ.大型民用建筑Ⅳ.没有架空线路走廊时",[211,212,213,215],{"key":19,"text":206,"correct":21},{"key":23,"text":192,"correct":21},{"key":26,"text":214,"correct":21},"Ⅱ、Ⅲ、Ⅳ",{"key":29,"text":194,"correct":31},{"id":217,"libraryId":5,"type":8,"typeLabel":15,"stem":218,"options":219,"answer":19,"analysis":32},922022,"正常运行情况下。一般电机用电设备处电压偏差允许值应按( )要求验算。",[220,222,224,226],{"key":19,"text":221,"correct":31},"±5%",{"key":23,"text":223,"correct":21},"±2.5%",{"key":26,"text":225,"correct":21},"±7%",{"key":29,"text":227,"correct":21},"±10%",{"id":229,"libraryId":5,"type":8,"typeLabel":15,"stem":230,"options":231,"answer":26,"analysis":32},922023,"为居民生活安装燃气热水器的厨房净高应大于( )m。",[232,233,235,237],{"key":19,"text":38,"correct":21},{"key":23,"text":234,"correct":21},"2.2",{"key":26,"text":236,"correct":31},"2.4",{"key":29,"text":238,"correct":21},"2.6",{"id":240,"libraryId":5,"type":8,"typeLabel":15,"stem":241,"options":242,"answer":26,"analysis":32},922024,"《建筑设计防火规范》规定，根据建筑物的性质和设施，要求设置或者不设闭式自动喷水灭火设备，请确定下列哪种情况是不必设的？( )",[243,244,245,246],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":31},{"key":29,"text":247,"correct":21},"藏书量超过50万册的图书馆",{"id":249,"libraryId":5,"type":8,"typeLabel":15,"stem":250,"options":251,"answer":29,"analysis":32},922025,"高层建筑内消火栓系统较典型有分区和不分区的两种，其中分区给水的室内消火栓给水系统一般适用建筑高度超过( )m。",[252,254,256,258],{"key":19,"text":253,"correct":21},"50",{"key":23,"text":255,"correct":21},"60",{"key":26,"text":257,"correct":21},"80",{"key":29,"text":259,"correct":31},"100",{"id":261,"libraryId":5,"type":8,"typeLabel":15,"stem":262,"options":263,"answer":29,"analysis":32},922026,"关于阳台排水系统的设置，下列叙述中错误的是( )。",[264,266,268,270],{"key":19,"text":265,"correct":21},"高层建筑阳台排水系统应单独设置",{"key":23,"text":267,"correct":21},"多层建筑阳台雨水宜单独设置",{"key":26,"text":269,"correct":21},"阳台雨水立管底部应间接排水",{"key":29,"text":271,"correct":31},"当生活阳台设有生活排水设备及地漏时，另设阳台雨水排水地漏",{"id":273,"libraryId":5,"type":8,"typeLabel":15,"stem":274,"options":275,"answer":26,"analysis":32},922027,"下列几条节能措施中不正确的是( )。",[276,278,280,282],{"key":19,"text":277,"correct":21},"用导热系数小的材料做外墙",{"key":23,"text":279,"correct":21},"提高建筑物窗户的密闭性",{"key":26,"text":281,"correct":31},"室内装修用明亮的颜色，以提高照明效果",{"key":29,"text":283,"correct":21},"为降低空调负荷，经常放下朝南的窗帘",{"id":285,"libraryId":5,"type":8,"typeLabel":15,"stem":286,"options":287,"answer":19,"analysis":32},922028,"某地新建可燃物品高层仓库，在消防上的要求是( )。",[288,290,292,294],{"key":19,"text":289,"correct":31},"除消火栓外，还应设自动喷水灭火系统",{"key":23,"text":291,"correct":21},"仅设消火栓系统",{"key":26,"text":293,"correct":21},"设水喷雾灭火系统",{"key":29,"text":295,"correct":21},"设雨淋灭火系统",{"id":297,"libraryId":5,"type":8,"typeLabel":15,"stem":298,"options":299,"answer":26,"analysis":32},922029,"采用集中热水供应系统的住宅，配水点的水温不应低于( )。",[300,302,304,306],{"key":19,"text":301,"correct":21},"37℃",{"key":23,"text":303,"correct":21},"40℃",{"key":26,"text":305,"correct":31},"45℃",{"key":29,"text":307,"correct":21},"50℃",{"id":309,"libraryId":5,"type":8,"typeLabel":15,"stem":310,"options":311,"answer":26,"analysis":32},922030,"某建筑屋面上设有烟道出口，且烟道与各用户的烟气排放口连接，为了减少屋面通气管数量，在顶层上，各排水通气管与烟道连接的正确方法应该是( )。",[312,314,316,318],{"key":19,"text":313,"correct":21},"通气管与烟道连接，在通气管出口加防回门",{"key":23,"text":315,"correct":21},"通气管可以与烟道直接连接",{"key":26,"text":317,"correct":31},"通气管应该单独从屋面上引出",{"key":29,"text":319,"correct":21},"通气管可以从烟道内通过再引出屋面外",{"id":321,"libraryId":5,"type":8,"typeLabel":15,"stem":322,"options":323,"answer":29,"analysis":32},922031,"给水管网的下列部位中，可以不装止回阀的是( )。",[324,326,328,330],{"key":19,"text":325,"correct":21},"进出水管合用一条管道的水箱、水塔、高地水池的出水管段上",{"key":23,"text":327,"correct":21},"生产设备内部可能产生的水压高于室内给水管网水压的设备配水支管",{"key":26,"text":329,"correct":21},"水泵出水管上",{"key":29,"text":331,"correct":31},"利用水泵进水的水箱进水管",{"id":333,"libraryId":5,"type":8,"typeLabel":15,"stem":334,"options":335,"answer":19,"analysis":32},922032,"相同面积、相同层数的建筑物，设计成下面四种朝向，其中围护结构采暖热负荷较小的是( )(图示为上北下南)。",[336,337,338,339],{"key":19,"text":32,"correct":31},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":21},{"id":341,"libraryId":5,"type":8,"typeLabel":15,"stem":342,"options":343,"answer":29,"analysis":32},922033,"接通电路后，电流流过导体，会在导体及其周围产生效应，但不包括( )。",[344,346,348,350],{"key":19,"text":345,"correct":21},"热效应",{"key":23,"text":347,"correct":21},"磁场效应",{"key":26,"text":349,"correct":21},"电场效应",{"key":29,"text":351,"correct":31},"声效应",{"id":353,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":354,"answer":19,"analysis":32},922034,[355,357,358,359],{"key":19,"text":356,"correct":31},"1",{"key":23,"text":38,"correct":21},{"key":26,"text":40,"correct":21},{"key":29,"text":360,"correct":21},"4",{"id":362,"libraryId":5,"type":8,"typeLabel":15,"stem":363,"options":364,"answer":26,"analysis":32},922035,"某大型体育馆的送风方式常采用的是( )。",[365,367,369,371],{"key":19,"text":366,"correct":21},"散流器送风",{"key":23,"text":368,"correct":21},"孔板送风",{"key":26,"text":370,"correct":31},"喷口送风",{"key":29,"text":372,"correct":21},"地板送风",{"id":374,"libraryId":5,"type":8,"typeLabel":15,"stem":375,"options":376,"answer":23,"analysis":32},922036,"下面哪类用电负荷为二级负荷？( )",[377,379,381,383],{"key":19,"text":378,"correct":21},"中断供电将造成人身伤亡者",{"key":23,"text":380,"correct":31},"中断供电将造成较大影响者",{"key":26,"text":382,"correct":21},"中断供电将造成重大损失者",{"key":29,"text":384,"correct":21},"中断供电造成公共场所秩序(严重)混乱者",{"id":386,"libraryId":5,"type":8,"typeLabel":15,"stem":387,"options":388,"answer":26,"analysis":32},922037,"在生产厂房重作业工作地点采暖温度不宜低于( )。",[389,391,393,395],{"key":19,"text":390,"correct":21},"15℃",{"key":23,"text":392,"correct":21},"12℃",{"key":26,"text":394,"correct":31},"14℃",{"key":29,"text":396,"correct":21},"8℃",{"id":398,"libraryId":5,"type":8,"typeLabel":15,"stem":399,"options":400,"answer":26,"analysis":32},922038,"住宅区内无护栏水体的近岸2m范围内及园桥、汀步附近2m范围内，水深不应大于( )m。",[401,403,405,407],{"key":19,"text":402,"correct":21},"0.3",{"key":23,"text":404,"correct":21},"0.4",{"key":26,"text":406,"correct":31},"0.5",{"key":29,"text":132,"correct":21},{"id":409,"libraryId":5,"type":8,"typeLabel":15,"stem":410,"options":411,"answer":29,"analysis":32},922039,"一类防火建筑中，下列( )位置不需要设置疏散指示标志灯。",[412,414,416,418],{"key":19,"text":413,"correct":21},"剧场通向走廊的出口",{"key":23,"text":415,"correct":21},"通行走廊的公共出口",{"key":26,"text":417,"correct":21},"楼梯间各层出口",{"key":29,"text":419,"correct":31},"电梯机房的出口糕一类防火建筑中，电梯机房的出口不需要设置疏散指示标志灯。",{"id":421,"libraryId":5,"type":8,"typeLabel":15,"stem":422,"options":423,"answer":26,"analysis":32},922040,"冬季舒适性空气调节室内计算参数温度应采用( )。",[424,426,428,430],{"key":19,"text":425,"correct":21},"10-14℃",{"key":23,"text":427,"correct":21},"14-16℃",{"key":26,"text":429,"correct":31},"18-24℃",{"key":29,"text":431,"correct":21},"20～22℃",{"id":433,"libraryId":5,"type":8,"typeLabel":15,"stem":434,"options":435,"answer":29,"analysis":32},922041,"设有器具通气管的排水系统图是( )。",[436,437,438,439],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":31},{"id":441,"libraryId":5,"type":8,"typeLabel":15,"stem":442,"options":443,"answer":29,"analysis":32},922042,"在下列单位中，电功率的单位是( )。",[444,446,448,450],{"key":19,"text":445,"correct":21},"伏特",{"key":23,"text":447,"correct":21},"安培",{"key":26,"text":449,"correct":21},"千瓦时",{"key":29,"text":451,"correct":31},"瓦",{"id":453,"libraryId":5,"type":8,"typeLabel":15,"stem":454,"options":455,"answer":23,"analysis":32},922043,"雨水斗格栅的进水孔有效面积，应等于连接管横断面积的( )。",[456,458,460,462],{"key":19,"text":457,"correct":21},"1-1.5倍",{"key":23,"text":459,"correct":31},"2-2.5倍",{"key":26,"text":461,"correct":21},"3-3.5倍",{"key":29,"text":463,"correct":21},"4-4.5倍",{"id":465,"libraryId":5,"type":8,"typeLabel":15,"stem":466,"options":467,"answer":29,"analysis":32},922044,"喷水池平面尺寸应满足喷头、管道、水泵泄水口、溢流口、吸水坑等的布置，为防止水的飞溅，池体每边一般比设计要求再加大( )m。",[468,470,472,474],{"key":19,"text":469,"correct":21},"0.1-0.2",{"key":23,"text":471,"correct":21},"0.2-0.3",{"key":26,"text":473,"correct":21},"0.3～0.4",{"key":29,"text":475,"correct":31},"0.5～1.0",{"id":477,"libraryId":5,"type":8,"typeLabel":15,"stem":478,"options":479,"answer":26,"analysis":32},922045,"低压配电系统当保护线(PE线)与相线所用材质相同时，对于相线芯线截面为35m㎡时，PE线的最小截面应为( )m㎡。",[480,482,483,485],{"key":19,"text":481,"correct":21},"6",{"key":23,"text":44,"correct":21},{"key":26,"text":484,"correct":31},"16",{"key":29,"text":486,"correct":21},"35",{"id":488,"libraryId":5,"type":8,"typeLabel":15,"stem":489,"options":490,"answer":19,"analysis":32},922046,"炎热地区的民用建筑和工业辅助建筑物，避免屋面受太阳辐射的较好方式是( )。",[491,493,495,497],{"key":19,"text":492,"correct":31},"采用通风屋顶",{"key":23,"text":494,"correct":21},"增加净空高度",{"key":26,"text":496,"correct":21},"加吊顶",{"key":29,"text":498,"correct":21},"增加屋顶厚度",{"id":500,"libraryId":5,"type":8,"typeLabel":15,"stem":501,"options":502,"answer":23,"analysis":32},922047,"设置在走道和大厅等公共场所的火灾应急广播扬声器的额定功率不应小于3W，其数量应能保证( )，",[503,505,507,509],{"key":19,"text":504,"correct":21},"从一个防火分区的任何部位到最近一个扬声器的距离不大于20m",{"key":23,"text":506,"correct":31},"从一个防火分区的任何部位到最近一个扬声器的距离不大于25m",{"key":26,"text":508,"correct":21},"从一个防火分区的任何部位到最近一个扬声器的距离不大于30m",{"key":29,"text":510,"correct":21},"从一个防火分区的任何部位到最近一个扬声器的距离不大于15m",{"id":512,"libraryId":5,"type":8,"typeLabel":15,"stem":513,"options":514,"answer":29,"analysis":32},922048,"对于住宅及公寓的电梯应按下列( )原则来选用。",[515,517,519,521],{"key":19,"text":516,"correct":21},"简易自动式",{"key":23,"text":518,"correct":21},"集选控制式",{"key":26,"text":520,"correct":21},"群控方式",{"key":29,"text":522,"correct":31},"禁止使用“无司机”自动工作方式",{"id":524,"libraryId":5,"type":8,"typeLabel":15,"stem":525,"options":526,"answer":29,"analysis":32},922049,"建筑物防雷电波侵入的措施是( )。",[527,529,531,533],{"key":19,"text":528,"correct":21},"设接闪针、接闪线、接闪带等",{"key":23,"text":530,"correct":21},"利用钢柱或钢筋混凝土柱内钢筋作为防雷装置引下线",{"key":26,"text":532,"correct":21},"建筑内部金属物或金属管道与圈梁钢筋或均压环连接",{"key":29,"text":534,"correct":31},"对进入建筑物的金属管道或电气线路全线或部分埋地引入并接地，对于低压架空线路在进出线处设避雷器并接地",{"id":536,"libraryId":5,"type":8,"typeLabel":15,"stem":537,"options":538,"answer":29,"analysis":32},922050,"建筑物防雷的目的是( )。Ⅰ.保护建筑物内部的人身安全；Ⅱ，防止建筑被破坏；Ⅲ，保护建筑物内部的危险品，防损坏、燃烧及爆炸；Ⅳ，保护建筑物内部的机电设备和电气线路不受损坏",[539,540,542,543],{"key":19,"text":204,"correct":21},{"key":23,"text":541,"correct":21},"Ⅲ、Ⅳ",{"key":26,"text":202,"correct":21},{"key":29,"text":194,"correct":31},{"id":545,"libraryId":5,"type":8,"typeLabel":15,"stem":546,"options":547,"answer":19,"analysis":32},922051,"新建住宅建筑内的公共用房和公用空间，应( )。",[548,550,552,554],{"key":19,"text":549,"correct":31},"单独设置采暖系统和热计量装置",{"key":23,"text":551,"correct":21},"单独设置采暖系统，不需要设置热计量装置",{"key":26,"text":553,"correct":21},"不需要单独设置采暖系统而需要单独设置热计量装置",{"key":29,"text":555,"correct":21},"不需要单独设置采暖系统和热计量装置",{"id":557,"libraryId":5,"type":8,"typeLabel":15,"stem":558,"options":559,"answer":23,"analysis":32},922052,"某放射性实验室或某散发较大量有害物车间可以采用的空气调节系统为( )。",[560,562,564,566],{"key":19,"text":561,"correct":21},"封闭式集中空气调节系统",{"key":23,"text":563,"correct":31},"直流式集中空气调节系统",{"key":26,"text":565,"correct":21},"混合式集中空气调节系统",{"key":29,"text":567,"correct":21},"半集中式空气调节系统",{"id":569,"libraryId":5,"type":8,"typeLabel":15,"stem":570,"options":571,"answer":26,"analysis":32},922053,"火灾自动报警系统的传输线路，应采用铜芯绝缘导线或铜芯电缆，其电压等级不应低于( )。",[572,574,576,578],{"key":19,"text":573,"correct":21},"交流110V",{"key":23,"text":575,"correct":21},"交流220V",{"key":26,"text":577,"correct":31},"交流250V",{"key":29,"text":579,"correct":21},"交流340V",{"id":581,"libraryId":5,"type":8,"typeLabel":15,"stem":582,"options":583,"answer":29,"analysis":32},922054,"挡风板下缘至屋面的距离，宜采用( )m。",[584,585,587,589],{"key":19,"text":473,"correct":21},{"key":23,"text":586,"correct":21},"0.4-0.5",{"key":26,"text":588,"correct":21},"0.5-0.6",{"key":29,"text":590,"correct":31},"0.1-0.3",[592,595,598,601,605,607],{"id":8,"name":593,"category":7,"favorite":594},"领导干部任职前廉政法规知识测试题",92,{"id":596,"name":597,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":599,"name":600,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":602,"name":603,"category":7,"favorite":604},534,"BIM工程师",0,{"id":606,"name":603,"category":7,"favorite":604},535,{"id":608,"name":609,"category":7,"favorite":604},536,"安全人A证"]