[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-54":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":598},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,54,50,2979,[13,33,45,53,65,77,89,101,113,125,137,149,157,169,181,193,205,217,229,237,249,261,273,285,296,308,320,332,344,356,365,377,389,401,413,425,437,449,461,471,482,494,505,517,527,539,551,563,575,586],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":26,"analysis":32},921905,"单选题","无需软化处理但又有软化处理原水的热水供应中热水锅炉和水加热器出口最高水温是( )。",[18,22,25,29],{"key":19,"text":20,"correct":21},"A","100℃",false,{"key":23,"text":24,"correct":21},"B","90℃",{"key":26,"text":27,"correct":28},"C","75℃",true,{"key":30,"text":31,"correct":21},"D","60℃","",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":35,"options":36,"answer":19,"analysis":32},921906,"经消毒处理后的医院污水，其排放范同正确的是( )。",[37,39,41,43],{"key":19,"text":38,"correct":28},"不得排入生活饮用水集中的取水点上游1000m和下游100m的水体范围内",{"key":23,"text":40,"correct":21},"不得排入生活饮用水集中的取水点上游100m和下游1000m的水体范围内",{"key":26,"text":42,"correct":21},"不得排入生活饮用水集中的取水点上游800m和下游100m的水体范围内",{"key":30,"text":44,"correct":21},"不得排入生活饮用水集中的取水点上游100m和下游800m的水体范围内",{"id":46,"libraryId":5,"type":8,"typeLabel":15,"stem":47,"options":48,"answer":30,"analysis":32},921907,"水平干管可以布置在顶层天花板下、屋顶上、阁楼中、上层技术层中的给水方式是( )。",[49,50,51,52],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":28},{"id":54,"libraryId":5,"type":8,"typeLabel":15,"stem":55,"options":56,"answer":23,"analysis":32},921908,"空调机房的楼板的耐火极限( )。",[57,59,61,63],{"key":19,"text":58,"correct":21},"不应小于1.0h",{"key":23,"text":60,"correct":28},"不应小于2h",{"key":26,"text":62,"correct":21},"不应小于2.5h",{"key":30,"text":64,"correct":21},"不应小于3.Oh",{"id":66,"libraryId":5,"type":8,"typeLabel":15,"stem":67,"options":68,"answer":26,"analysis":32},921909,"下列哪类高层民用建筑的特定部位应设排烟设施？( )",[69,71,73,75],{"key":19,"text":70,"correct":21},"高层建筑",{"key":23,"text":72,"correct":21},"一类高层建筑和二类高层建筑",{"key":26,"text":74,"correct":28},"一类高层建筑和建筑高度超过32m的二类高层建筑",{"key":30,"text":76,"correct":21},"超过50m的一类公建和建筑高度超过100m的居住建筑",{"id":78,"libraryId":5,"type":8,"typeLabel":15,"stem":79,"options":80,"answer":30,"analysis":32},921910,"与铸铁散热器比较，钢制散热器用于高层建筑供暖系统中，在( )方面占有绝对优势。",[81,83,85,87],{"key":19,"text":82,"correct":21},"美观",{"key":23,"text":84,"correct":21},"耐腐蚀",{"key":26,"text":86,"correct":21},"容水量",{"key":30,"text":88,"correct":28},"承压",{"id":90,"libraryId":5,"type":8,"typeLabel":15,"stem":91,"options":92,"answer":26,"analysis":32},921911,"第二类防雷建筑物中，高度超过( )m时的钢筋混凝土和钢结构建筑物，应采取防侧击雷和等电位的保护措施。",[93,95,97,99],{"key":19,"text":94,"correct":21},"30",{"key":23,"text":96,"correct":21},"40",{"key":26,"text":98,"correct":28},"45",{"key":30,"text":100,"correct":21},"50",{"id":102,"libraryId":5,"type":8,"typeLabel":15,"stem":103,"options":104,"answer":19,"analysis":32},921912,"低压架空线路在最大风偏情况下，线路的边导线与建筑物之间的水平距离不应小于( )m。",[105,107,109,111],{"key":19,"text":106,"correct":28},"1",{"key":23,"text":108,"correct":21},"1.8",{"key":26,"text":110,"correct":21},"0.5",{"key":30,"text":112,"correct":21},"3",{"id":114,"libraryId":5,"type":8,"typeLabel":15,"stem":115,"options":116,"answer":26,"analysis":32},921913,"室外配电线路导线的截面按机械强度要求，铝绞线截面应不小于( )m㎡。",[117,119,121,123],{"key":19,"text":118,"correct":21},"6",{"key":23,"text":120,"correct":21},"10",{"key":26,"text":122,"correct":28},"16",{"key":30,"text":124,"correct":21},"25",{"id":126,"libraryId":5,"type":8,"typeLabel":15,"stem":127,"options":128,"answer":26,"analysis":32},921914,"灭火剂种类很多，目前国内外使用的主要灭火剂是( )。",[129,131,133,135],{"key":19,"text":130,"correct":21},"二氧化碳",{"key":23,"text":132,"correct":21},"泡沫",{"key":26,"text":134,"correct":28},"水",{"key":30,"text":136,"correct":21},"干粉",{"id":138,"libraryId":5,"type":8,"typeLabel":15,"stem":139,"options":140,"answer":19,"analysis":32},921915,"高层建筑的消防水箱中消防贮水量为( )。",[141,143,145,147],{"key":19,"text":142,"correct":28},"一类公共建筑不小于l8m3，二类公共建筑和一类居住建筑不小于l2m3，二类居住建筑不小于6m3",{"key":23,"text":144,"correct":21},"一类建筑不小于l8m3，二类建筑不小于l2m3",{"key":26,"text":146,"correct":21},"一类建筑不小于l2m3，二类建筑不小于6m3",{"key":30,"text":148,"correct":21},"一类建筑住宅不小于l8m3，二类建筑住宅不小于11m3",{"id":150,"libraryId":5,"type":8,"typeLabel":15,"stem":151,"options":152,"answer":23,"analysis":32},921916,"为了在生活用水时不动用水箱内的消防贮水量，下图( )错误。",[153,154,155,156],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":28},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":21},{"id":158,"libraryId":5,"type":8,"typeLabel":15,"stem":159,"options":160,"answer":23,"analysis":32},921917,"为了提高用电设备的功率因数，通常使用( )。",[161,163,165,167],{"key":19,"text":162,"correct":21},"变压器",{"key":23,"text":164,"correct":28},"电容器",{"key":26,"text":166,"correct":21},"整流器",{"key":30,"text":168,"correct":21},"继电器",{"id":170,"libraryId":5,"type":8,"typeLabel":15,"stem":171,"options":172,"answer":26,"analysis":32},921918,"下列线路敷设方式中( )禁止在吊顶内使用。",[173,175,177,179],{"key":19,"text":174,"correct":21},"绝缘导线穿金属管敷设",{"key":23,"text":176,"correct":21},"封闭式金属线槽",{"key":26,"text":178,"correct":28},"用塑料线夹布线",{"key":30,"text":180,"correct":21},"封闭母线沿吊架敷设",{"id":182,"libraryId":5,"type":8,"typeLabel":15,"stem":183,"options":184,"answer":23,"analysis":32},921919,"机械加压送风的部位应有的余压值，下面( )不符合《高规》要求。",[185,187,189,191],{"key":19,"text":186,"correct":21},"防烟楼梯间为50Pa",{"key":23,"text":188,"correct":28},"封闭避难层为50Pa",{"key":26,"text":190,"correct":21},"前室、合用前室为25Pa",{"key":30,"text":192,"correct":21},"消防电梯前室为25Pa",{"id":194,"libraryId":5,"type":8,"typeLabel":15,"stem":195,"options":196,"answer":30,"analysis":32},921920,"设置水箱的原则，以下错误的是( )。",[197,199,201,203],{"key":19,"text":198,"correct":21},"为保持给水系统的恒压条件",{"key":23,"text":200,"correct":21},"系统中需要一定调节水量或要求贮存消防水量",{"key":26,"text":202,"correct":21},"室外供水周期不足或经常不足",{"key":30,"text":204,"correct":28},"可节约用水、节省经常维护费用",{"id":206,"libraryId":5,"type":8,"typeLabel":15,"stem":207,"options":208,"answer":19,"analysis":32},921921,"不需另设热水供应锅炉房的条件是( )。",[209,211,213,215],{"key":19,"text":210,"correct":28},"区域性锅炉房或附近的锅炉房能充分供给蒸汽或高温水",{"key":23,"text":212,"correct":21},"区域性锅炉房或附近的锅炉房不能充分供给蒸汽或高温水",{"key":26,"text":214,"correct":21},"热水采暖锅炉",{"key":30,"text":216,"correct":21},"生产用锅炉所提供的蒸汽或高温水稍有余富量",{"id":218,"libraryId":5,"type":8,"typeLabel":15,"stem":219,"options":220,"answer":23,"analysis":32},921922,"通风及空调系统的垂直风管设在管道井内，对井壁要求是( )。",[221,223,225,227],{"key":19,"text":222,"correct":21},"井壁耐火等级≮1th的非燃烧体，井壁上的检查门采用乙级防火门",{"key":23,"text":224,"correct":28},"井壁耐火等级≮1h的非燃烧体，井壁上的检查门采用丙级防火门",{"key":26,"text":226,"correct":21},"井壁耐火等级≮2h的非燃烧体，井壁上的检查门采用乙级防火门",{"key":30,"text":228,"correct":21},"井壁耐火等级≮2h的非燃烧体，井壁上的检查门采用丙级防火门",{"id":230,"libraryId":5,"type":8,"typeLabel":15,"stem":231,"options":232,"answer":26,"analysis":32},921923,"下列( )为蒸汽间接加热热水供应。",[233,234,235,236],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":28},{"key":30,"text":32,"correct":21},{"id":238,"libraryId":5,"type":8,"typeLabel":15,"stem":239,"options":240,"answer":23,"analysis":32},921924,"对多层住宅小区来说，380\u002F220V低压变电所供电半径不宜超过( )。",[241,243,245,247],{"key":19,"text":242,"correct":21},"400m",{"key":23,"text":244,"correct":28},"250m",{"key":26,"text":246,"correct":21},"150m",{"key":30,"text":248,"correct":21},"100m",{"id":250,"libraryId":5,"type":8,"typeLabel":15,"stem":251,"options":252,"answer":30,"analysis":32},921925,"供暖建筑外窗的层数与下列哪个因素无关？( )",[253,255,257,259],{"key":19,"text":254,"correct":21},"室外温度",{"key":23,"text":256,"correct":21},"室内外温度差",{"key":26,"text":258,"correct":21},"朝向",{"key":30,"text":260,"correct":28},"墙体材料",{"id":262,"libraryId":5,"type":8,"typeLabel":15,"stem":263,"options":264,"answer":23,"analysis":32},921926,"由高低压线路至建筑物第一支持点之间的一段架空线，称为接户线，高、低压接户线在受电端的对地距离不应小于下列哪一组数值？( )",[265,267,269,271],{"key":19,"text":266,"correct":21},"高压接户线4.5m，低压接户线2.5m",{"key":23,"text":268,"correct":28},"高压接户线4m，低压接户线2.5m",{"key":26,"text":270,"correct":21},"高压接户线4m，低压接户线2.2m",{"key":30,"text":272,"correct":21},"高压接户线3.5m，低压接户线2.2m",{"id":274,"libraryId":5,"type":8,"typeLabel":15,"stem":275,"options":276,"answer":23,"analysis":32},921927,"下面哪一种方法不能作为照明的正常节电措施？( )",[277,279,281,283],{"key":19,"text":278,"correct":21},"采用高效光源",{"key":23,"text":280,"correct":28},"降低照度标准",{"key":26,"text":282,"correct":21},"气体放电灯安装电容器",{"key":30,"text":284,"correct":21},"采用光电控制室外照明",{"id":286,"libraryId":5,"type":8,"typeLabel":15,"stem":287,"options":288,"answer":23,"analysis":32},921928,"塑料排水立管与家用灶具边的净距不得小于( )m。",[289,291,293,294],{"key":19,"text":290,"correct":21},"0.3",{"key":23,"text":292,"correct":28},"0.4",{"key":26,"text":110,"correct":21},{"key":30,"text":295,"correct":21},"0.6",{"id":297,"libraryId":5,"type":8,"typeLabel":15,"stem":298,"options":299,"answer":26,"analysis":32},921929,"室内消防水箱的储水量应当满足( )。",[300,302,304,306],{"key":19,"text":301,"correct":21},"30分钟消防用水量",{"key":23,"text":303,"correct":21},"15分钟消防用水量",{"key":26,"text":305,"correct":28},"10分钟消防用水量",{"key":30,"text":307,"correct":21},"5分钟消防用水量",{"id":309,"libraryId":5,"type":8,"typeLabel":15,"stem":310,"options":311,"answer":23,"analysis":32},921930,"某旅馆的广播控制室宜( )。",[312,314,316,318],{"key":19,"text":313,"correct":21},"靠近业务主管部门",{"key":23,"text":315,"correct":28},"与电视播放室合并",{"key":26,"text":317,"correct":21},"靠近交通调度室",{"key":30,"text":319,"correct":21},"靠近消防控制室",{"id":321,"libraryId":5,"type":8,"typeLabel":15,"stem":322,"options":323,"answer":30,"analysis":32},921931,"高度超过100m的高层建筑及裙房，应设自动喷水灭火系统，以下设置部位错误的是( )。",[324,326,328,330],{"key":19,"text":325,"correct":21},"公共活动用房，高级住宅的居住用房",{"key":23,"text":327,"correct":21},"走道、办公室和旅馆的客房",{"key":26,"text":329,"correct":21},"自动扶梯底部",{"key":30,"text":331,"correct":28},"可燃油油浸电力变压器室",{"id":333,"libraryId":5,"type":8,"typeLabel":15,"stem":334,"options":335,"answer":26,"analysis":32},921932,"-些大城市为节约用水，要求设置中水系统，中水水源要求首先采用优质杂排水，下列属于优质杂排水的是( )。",[336,338,340,342],{"key":19,"text":337,"correct":21},"厕所排水",{"key":23,"text":339,"correct":21},"厨房排水",{"key":26,"text":341,"correct":28},"洗衣排水",{"key":30,"text":343,"correct":21},"医院排水",{"id":345,"libraryId":5,"type":8,"typeLabel":15,"stem":346,"options":347,"answer":30,"analysis":32},921933,"喷泉的喷嘴不宜采用( )质材料。",[348,350,352,354],{"key":19,"text":349,"correct":21},"铜",{"key":23,"text":351,"correct":21},"塑料",{"key":26,"text":353,"correct":21},"不锈钢",{"key":30,"text":355,"correct":28},"铁",{"id":357,"libraryId":5,"type":8,"typeLabel":15,"stem":358,"options":359,"answer":23,"analysis":32},921934,"室外排水管道管径小于等于150mm时，检查井间距不宜大于( )m。",[360,361,363,364],{"key":19,"text":120,"correct":21},{"key":23,"text":362,"correct":28},"20",{"key":26,"text":94,"correct":21},{"key":30,"text":96,"correct":21},{"id":366,"libraryId":5,"type":8,"typeLabel":15,"stem":367,"options":368,"answer":30,"analysis":32},921935,"消防用水的贮水量应满足在火灾延续时间内，室内外消防用水总量的要求；居住区的火灾延续时间应按( )计算。",[369,371,373,375],{"key":19,"text":370,"correct":21},"0.5h",{"key":23,"text":372,"correct":21},"1.0h",{"key":26,"text":374,"correct":21},"1.5h",{"key":30,"text":376,"correct":28},"2.0h",{"id":378,"libraryId":5,"type":8,"typeLabel":15,"stem":379,"options":380,"answer":26,"analysis":32},921936,"正弦交流电网电压值，如380V／220V，指的是( )。",[381,383,385,387],{"key":19,"text":382,"correct":21},"电压的峰值",{"key":23,"text":384,"correct":21},"电压的平均值",{"key":26,"text":386,"correct":28},"电压的有效值",{"key":30,"text":388,"correct":21},"电压某一瞬间的瞬时值",{"id":390,"libraryId":5,"type":8,"typeLabel":15,"stem":391,"options":392,"answer":26,"analysis":32},921937,"下列( )作为应急电源是错误的。",[393,395,397,399],{"key":19,"text":394,"correct":21},"蓄电池",{"key":23,"text":396,"correct":21},"独立于正常电源的发电机组",{"key":26,"text":398,"correct":28},"从正常电源中引出一路专用的馈电线路",{"key":30,"text":400,"correct":21},"干电池",{"id":402,"libraryId":5,"type":8,"typeLabel":15,"stem":403,"options":404,"answer":26,"analysis":32},921938,"在高层民用建筑内，下述部位中( )宜设感温探测器。",[405,407,409,411],{"key":19,"text":406,"correct":21},"电梯前室",{"key":23,"text":408,"correct":21},"走廊",{"key":26,"text":410,"correct":28},"发电机房",{"key":30,"text":412,"correct":21},"楼梯间",{"id":414,"libraryId":5,"type":8,"typeLabel":15,"stem":415,"options":416,"answer":23,"analysis":32},921939,"制冷机与墙壁之间的距离和非主要通道的宽度不应小于( )m。",[417,419,421,423],{"key":19,"text":418,"correct":21},"0.7",{"key":23,"text":420,"correct":28},"0.8",{"key":26,"text":422,"correct":21},"0.9",{"key":30,"text":424,"correct":21},"1.0",{"id":426,"libraryId":5,"type":8,"typeLabel":15,"stem":427,"options":428,"answer":19,"analysis":32},921940,"当室内燃气管道穿过楼板、楼梯平台、墙壁和隔墙时应采取的做法为( )。",[429,431,433,435],{"key":19,"text":430,"correct":28},"设套管",{"key":23,"text":432,"correct":21},"设软接头",{"key":26,"text":434,"correct":21},"保温",{"key":30,"text":436,"correct":21},"设固定点",{"id":438,"libraryId":5,"type":8,"typeLabel":15,"stem":439,"options":440,"answer":30,"analysis":32},921941,"下列房间应保持正压的是( )。",[441,443,445,447],{"key":19,"text":442,"correct":21},"厨房",{"key":23,"text":444,"correct":21},"卫生间",{"key":26,"text":446,"correct":21},"麻醉室",{"key":30,"text":448,"correct":28},"手术室",{"id":450,"libraryId":5,"type":8,"typeLabel":15,"stem":451,"options":452,"answer":19,"analysis":32},921942,"加热管埋设在建筑构件内的低温辐射采暖，可用于民用建筑的全面采暖或局部采暖，辐射体表面平均温度在经常有人停留的地面采用( )。",[453,455,457,459],{"key":19,"text":454,"correct":28},"24℃～26℃",{"key":23,"text":456,"correct":21},"28℃～30℃",{"key":26,"text":458,"correct":21},"35℃～40℃",{"key":30,"text":460,"correct":21},"40℃～45℃",{"id":462,"libraryId":5,"type":8,"typeLabel":15,"stem":463,"options":464,"answer":26,"analysis":32},921943,"游泳池补水管应接入平衡水池，且补水管上的水位控制阀门的出水口应高于游泳池最高水面( )mm。",[465,466,468,470],{"key":19,"text":100,"correct":21},{"key":23,"text":467,"correct":21},"70",{"key":26,"text":469,"correct":28},"100",{"key":30,"text":94,"correct":21},{"id":472,"libraryId":5,"type":8,"typeLabel":15,"stem":473,"options":474,"answer":23,"analysis":32},921944,"民用建筑热水采暖管道中的热媒最大流速为( )m\u002Fs。",[475,476,478,480],{"key":19,"text":424,"correct":21},{"key":23,"text":477,"correct":28},"1.2",{"key":26,"text":479,"correct":21},"1.5",{"key":30,"text":481,"correct":21},"2，0",{"id":483,"libraryId":5,"type":8,"typeLabel":15,"stem":484,"options":485,"answer":26,"analysis":32},921945,"卫生器具数量的确定根据( )。",[486,488,490,492],{"key":19,"text":487,"correct":21},"建筑面积",{"key":23,"text":489,"correct":21},"建筑层数",{"key":26,"text":491,"correct":28},"现行的《工业企业设计卫生标准》和现行的有关设计标准、规范或规定",{"key":30,"text":493,"correct":21},"用水量大小",{"id":495,"libraryId":5,"type":8,"typeLabel":15,"stem":496,"options":497,"answer":26,"analysis":32},921946,"建筑面积大于( )㎡的商业服务网点应设置消防软管卷盘或轻便消防水龙。",[498,499,501,503],{"key":19,"text":469,"correct":21},{"key":23,"text":500,"correct":21},"150",{"key":26,"text":502,"correct":28},"200",{"key":30,"text":504,"correct":21},"250",{"id":506,"libraryId":5,"type":8,"typeLabel":15,"stem":507,"options":508,"answer":19,"analysis":32},921947,"热风幕条缝和孔口外的送风速度，应通过计算确定。对于公共建筑的外门、生产厂房的外门和高大的外门均分别相应为( )。",[509,511,513,515],{"key":19,"text":510,"correct":28},"＞6m\u002Fs；≯8m\u002Fs；≯25m\u002Fs",{"key":23,"text":512,"correct":21},"≯5m\u002Fs；≯7m\u002Fs；≯24m／s",{"key":26,"text":514,"correct":21},"≯7m\u002Fs；≯9m\u002Fs；≯26m\u002Fs",{"key":30,"text":516,"correct":21},"≯8m\u002Fs；≯10m\u002Fs≯27m\u002Fs",{"id":518,"libraryId":5,"type":8,"typeLabel":15,"stem":519,"options":520,"answer":30,"analysis":32},921948,"美术教室桌面的照度标准值是( )lx。",[521,522,523,525],{"key":19,"text":469,"correct":21},{"key":23,"text":502,"correct":21},{"key":26,"text":524,"correct":21},"300",{"key":30,"text":526,"correct":28},"500",{"id":528,"libraryId":5,"type":8,"typeLabel":15,"stem":529,"options":530,"answer":19,"analysis":32},921949,"机械通风系统中设计建筑室外进、排风口位置时，以下说法错误的是( )。",[531,533,535,537],{"key":19,"text":532,"correct":28},"进、排风口在同一平面位置上、下布置时，进风口要高于排风口",{"key":23,"text":534,"correct":21},"进风口应尽量布置在北向阴凉处",{"key":26,"text":536,"correct":21},"进风口应直接设在室外空气较清洁的地点",{"key":30,"text":538,"correct":21},"设于外墙时，进、排风口应采用防雨百叶风口",{"id":540,"libraryId":5,"type":8,"typeLabel":15,"stem":541,"options":542,"answer":23,"analysis":32},921950,"地表水源指( )。",[543,545,547,549],{"key":19,"text":544,"correct":21},"江水、河水、泉水、水库水、海水",{"key":23,"text":546,"correct":28},"江水、河水、湖水、水库水、海水",{"key":26,"text":548,"correct":21},"江水、河水、湖水、井水",{"key":30,"text":550,"correct":21},"江水、河水、海水、溶洞水",{"id":552,"libraryId":5,"type":8,"typeLabel":15,"stem":553,"options":554,"answer":19,"analysis":32},921951,"我国将于2010年停产卤代烷1301灭火剂，其原因正确的是( )。",[555,557,559,561],{"key":19,"text":556,"correct":28},"出于环保",{"key":23,"text":558,"correct":21},"毒性太大",{"key":26,"text":560,"correct":21},"使用效果不佳",{"key":30,"text":562,"correct":21},"价格昂贵",{"id":564,"libraryId":5,"type":8,"typeLabel":15,"stem":565,"options":566,"answer":26,"analysis":32},921952,"对某些特等建筑，如重要的交通、通信枢纽、国宾馆、国家级的会堂等场所的供电，《民用建筑电气设计规范》将其列为一级负荷中的( )。",[567,569,571,573],{"key":19,"text":568,"correct":21},"特别负荷",{"key":23,"text":570,"correct":21},"重要负荷",{"key":26,"text":572,"correct":28},"特别重要负荷",{"key":30,"text":574,"correct":21},"安全负荷",{"id":576,"libraryId":5,"type":8,"typeLabel":15,"stem":577,"options":578,"answer":19,"analysis":32},921953,"下列( )电源形式不属于安全超低压配电电源。",[579,581,583,584],{"key":19,"text":580,"correct":28},"普通电力变压器",{"key":23,"text":582,"correct":21},"电动发电机组",{"key":26,"text":394,"correct":21},{"key":30,"text":585,"correct":21},"端子电压不超过50Ⅴ的电子装置",{"id":587,"libraryId":5,"type":8,"typeLabel":15,"stem":588,"options":589,"answer":23,"analysis":32},921954,"多层和高层建筑的机械送排风系统的风管横向设置应按( )分区。",[590,592,594,596],{"key":19,"text":591,"correct":21},"防烟",{"key":23,"text":593,"correct":28},"防火",{"key":26,"text":595,"correct":21},"平面功能",{"key":30,"text":597,"correct":21},"沉降缝",[599,602,605,608,612,614],{"id":8,"name":600,"category":7,"favorite":601},"领导干部任职前廉政法规知识测试题",92,{"id":603,"name":604,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":606,"name":607,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":609,"name":610,"category":7,"favorite":611},534,"BIM工程师",0,{"id":613,"name":610,"category":7,"favorite":611},535,{"id":615,"name":616,"category":7,"favorite":611},536,"安全人A证"]