[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-52":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":613},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,52,50,2979,[13,29,41,53,65,77,89,101,113,125,137,149,161,173,185,197,209,221,233,245,256,268,280,292,304,316,328,340,352,364,376,388,400,412,424,436,448,460,472,484,496,508,520,532,544,556,568,580,592,601],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":19,"analysis":20},921805,"单选题","以下消火栓的布置示意( )是错误的。",[18,22,25,27],{"key":19,"text":20,"correct":21},"A","",true,{"key":23,"text":20,"correct":24},"B",false,{"key":26,"text":20,"correct":24},"C",{"key":28,"text":20,"correct":24},"D",{"id":30,"libraryId":5,"type":8,"typeLabel":15,"stem":31,"options":32,"answer":19,"analysis":20},921806,"为保证高位水箱内的水质不受空气污染，应采取以下措施，但其中不妥的一点是( )。",[33,35,37,39],{"key":19,"text":34,"correct":21},"高位水箱加密闭盖，使水箱承压",{"key":23,"text":36,"correct":24},"高位水箱加盖，上面留有通气孔和检修人孔",{"key":26,"text":38,"correct":24},"高位水箱为活动盖，盖上留通气孔",{"key":28,"text":40,"correct":24},"高位水箱加盖，并设检修人孔盖且在人孔盖上增加通气孔",{"id":42,"libraryId":5,"type":8,"typeLabel":15,"stem":43,"options":44,"answer":28,"analysis":20},921807,"建筑排水管道分三类，其中不包括( )。",[45,47,49,51],{"key":19,"text":46,"correct":24},"生活排水管道",{"key":23,"text":48,"correct":24},"工业废水管道",{"key":26,"text":50,"correct":24},"建筑内雨水管道",{"key":28,"text":52,"correct":21},"粪便水管道",{"id":54,"libraryId":5,"type":8,"typeLabel":15,"stem":55,"options":56,"answer":23,"analysis":20},921808,"大便槽的上槽宽一般为( )mm。",[57,59,61,63],{"key":19,"text":58,"correct":24},"200",{"key":23,"text":60,"correct":21},"200-250",{"key":26,"text":62,"correct":24},"300-350",{"key":28,"text":64,"correct":24},"350-400",{"id":66,"libraryId":5,"type":8,"typeLabel":15,"stem":67,"options":68,"answer":28,"analysis":20},921809,"下列室外电缆沟的防水措施中，( )项最重要。",[69,71,73,75],{"key":19,"text":70,"correct":24},"做好沟盖板板缝的密封",{"key":23,"text":72,"correct":24},"做好沟内的防水处理.",{"key":26,"text":74,"correct":24},"做好电缆引入、引出管的防水密封",{"key":28,"text":76,"correct":21},"在电缆沟底部做坡度不小于0.5%的排水沟，将积水直接排入排水管或经集水坑用泵排水",{"id":78,"libraryId":5,"type":8,"typeLabel":15,"stem":79,"options":80,"answer":28,"analysis":20},921810,"空调房间的计算冷负荷是指( )。",[81,83,85,87],{"key":19,"text":82,"correct":24},"通过围护结构传热形成的冷负荷",{"key":23,"text":84,"correct":24},"透过外窗太阳辐射热形成的冷负荷",{"key":26,"text":86,"correct":24},"人或设备等形成的冷负荷",{"key":28,"text":88,"correct":21},"上述几项逐时冷负荷的累计",{"id":90,"libraryId":5,"type":8,"typeLabel":15,"stem":91,"options":92,"answer":23,"analysis":20},921811,"管道井尺寸应根据管道数量、管径大小、排列方式、维修条件，结合建筑平面和结构形式等合理确定，当需要进入检修时，其维修人员的工作通道净宽度不宜小于( )。",[93,95,97,99],{"key":19,"text":94,"correct":24},"0.5m",{"key":23,"text":96,"correct":21},"0.6m",{"key":26,"text":98,"correct":24},"0.7m",{"key":28,"text":100,"correct":24},"0.8m",{"id":102,"libraryId":5,"type":8,"typeLabel":15,"stem":103,"options":104,"answer":23,"analysis":20},921812,"电动机回路中的热继电器的作用是( )。",[105,107,109,111],{"key":19,"text":106,"correct":24},"回路保护",{"key":23,"text":108,"correct":21},"过载保护",{"key":26,"text":110,"correct":24},"漏电保护",{"key":28,"text":112,"correct":24},"低电压保护",{"id":114,"libraryId":5,"type":8,"typeLabel":15,"stem":115,"options":116,"answer":28,"analysis":20},921813,"下列部位中，( )适合选用节能自熄开关控制照明。",[117,119,121,123],{"key":19,"text":118,"correct":24},"办公室",{"key":23,"text":120,"correct":24},"电梯前室",{"key":26,"text":122,"correct":24},"旅馆大厅",{"key":28,"text":124,"correct":21},"住宅及办公楼的疏散楼梯",{"id":126,"libraryId":5,"type":8,"typeLabel":15,"stem":127,"options":128,"answer":28,"analysis":20},921814,"利用穿堂风进行自然通风的厂房，其迎风面与夏季最多风向成( )度角时为好。",[129,131,133,135],{"key":19,"text":130,"correct":24},"20",{"key":23,"text":132,"correct":24},"30",{"key":26,"text":134,"correct":24},"40",{"key":28,"text":136,"correct":21},"80",{"id":138,"libraryId":5,"type":8,"typeLabel":15,"stem":139,"options":140,"answer":23,"analysis":20},921815,"围护结构的附加耗热量，应按其占基本耗热量的百分率确定，其中东、西向修正率为( )。",[141,143,145,147],{"key":19,"text":142,"correct":24},"0%～10%",{"key":23,"text":144,"correct":21},"-5%",{"key":26,"text":146,"correct":24},"-10%～-15%",{"key":28,"text":148,"correct":24},"-15%～-30%",{"id":150,"libraryId":5,"type":8,"typeLabel":15,"stem":151,"options":152,"answer":26,"analysis":20},921816,"《建筑设计防火规范》(GB50016-2006)规定，根据建筑物的性质和设施，要求设置或者不设自动喷水灭火系统，下列情况是不必设的是( )。",[153,155,157,159],{"key":19,"text":154,"correct":24},"设有送回风管道的集中空调系统且总建筑面积大于3000㎡的办公楼：",{"key":23,"text":156,"correct":24},"总建筑面积大于3000㎡的旅馆",{"key":26,"text":158,"correct":21},"建筑面积500㎡的地下商店",{"key":28,"text":160,"correct":24},"藏书量为60万册的图书馆",{"id":162,"libraryId":5,"type":8,"typeLabel":15,"stem":163,"options":164,"answer":19,"analysis":20},921817,"消防水池的容量确定，以下叙述正确的是( )。",[165,167,169,171],{"key":19,"text":166,"correct":21},"应满足在火灾延续时间内室内外消防用水量不足部分之和",{"key":23,"text":168,"correct":24},"应满足在火灾延续时间内室外消防水量的总和",{"key":26,"text":170,"correct":24},"应满足在火灾延续时间内室内消防水量的总和",{"key":28,"text":172,"correct":24},"应满足在火灾延续时间内自动消防水量的总和",{"id":174,"libraryId":5,"type":8,"typeLabel":15,"stem":175,"options":176,"answer":26,"analysis":20},921818,"下面( )不属于电力负荷中的一级负荷。",[177,179,181,183],{"key":19,"text":178,"correct":24},"中断供电将造成人身伤亡者",{"key":23,"text":180,"correct":24},"中断供电将造成重大经济损失者",{"key":26,"text":182,"correct":21},"中断供电将造成较大政治影响者",{"key":28,"text":184,"correct":24},"中断供电将造成公共场所秩序严重混乱者",{"id":186,"libraryId":5,"type":8,"typeLabel":15,"stem":187,"options":188,"answer":23,"analysis":20},921819,"按防火等级分类，高层建筑中的一类建筑属于( )保护对象。",[189,191,193,195],{"key":19,"text":190,"correct":24},"特级",{"key":23,"text":192,"correct":21},"一级",{"key":26,"text":194,"correct":24},"二级",{"key":28,"text":196,"correct":24},"三级",{"id":198,"libraryId":5,"type":8,"typeLabel":15,"stem":199,"options":200,"answer":28,"analysis":20},921820,"屋面雨水悬吊管的最大计算充满度为( )。",[201,203,205,207],{"key":19,"text":202,"correct":24},"0.5",{"key":23,"text":204,"correct":24},"0.6",{"key":26,"text":206,"correct":24},"0.7",{"key":28,"text":208,"correct":21},"0.8",{"id":210,"libraryId":5,"type":8,"typeLabel":15,"stem":211,"options":212,"answer":23,"analysis":20},921821,"钢管螺纹连接时，使管道直长度增加的管件有( )。",[213,215,217,219],{"key":19,"text":214,"correct":24},"三通、四通、弯头",{"key":23,"text":216,"correct":21},"管箍、活接",{"key":26,"text":218,"correct":24},"内接、丝堵",{"key":28,"text":220,"correct":24},"根母",{"id":222,"libraryId":5,"type":8,"typeLabel":15,"stem":223,"options":224,"answer":19,"analysis":20},921822,"在建筑照明系统中，插座的以下几种安装方式中正确的是( )。",[225,227,229,231],{"key":19,"text":226,"correct":21},"与正常照明灯具共用一个回路，插座不超过5个",{"key":23,"text":228,"correct":24},"与消防设备共用一个回路",{"key":26,"text":230,"correct":24},"与备用照明共用一个回路",{"key":28,"text":232,"correct":24},"与疏散照明共用一个回路",{"id":234,"libraryId":5,"type":8,"typeLabel":15,"stem":235,"options":236,"answer":28,"analysis":20},921823,"下列( )可以与污废水管道系统直接连接，不必采取间接排水的方式。",[237,239,241,243],{"key":19,"text":238,"correct":24},"生活饮用水贮水箱(池)的泄水管和溢流管",{"key":23,"text":240,"correct":24},"开水器、热水器排水",{"key":26,"text":242,"correct":24},"医疗灭菌消毒设备的排水",{"key":28,"text":244,"correct":21},"洗脸盆、浴盆的排水",{"id":246,"libraryId":5,"type":8,"typeLabel":15,"stem":247,"options":248,"answer":23,"analysis":20},921824,"大便槽底宽一般为( )mm。",[249,251,253,254],{"key":19,"text":250,"correct":24},"100",{"key":23,"text":252,"correct":21},"150",{"key":26,"text":58,"correct":24},{"key":28,"text":255,"correct":24},"250",{"id":257,"libraryId":5,"type":8,"typeLabel":15,"stem":258,"options":259,"answer":28,"analysis":20},921825,"自动喷水灭火系统给水管道的水流速度，宜采用经济流速，必要时可超过Sm\u002Fs，但是不应大于( )m\u002Fs。",[260,262,264,266],{"key":19,"text":261,"correct":24},"5",{"key":23,"text":263,"correct":24},"7",{"key":26,"text":265,"correct":24},"9",{"key":28,"text":267,"correct":21},"10",{"id":269,"libraryId":5,"type":8,"typeLabel":15,"stem":270,"options":271,"answer":28,"analysis":20},921826,"排除潮湿气体或含有水蒸气的风管，其内壁可能出现凝结水，其坡度是( )。",[272,274,276,278],{"key":19,"text":273,"correct":24},"0.001",{"key":23,"text":275,"correct":24},"0.002",{"key":26,"text":277,"correct":24},"0.003",{"key":28,"text":279,"correct":21},"0.005",{"id":281,"libraryId":5,"type":8,"typeLabel":15,"stem":282,"options":283,"answer":28,"analysis":20},921827,"氨制冷机房对出口的要求，下列中的哪一条是不对的？( )",[284,286,288,290],{"key":19,"text":285,"correct":24},"应有两个出口",{"key":23,"text":287,"correct":24},"两个出口应尽量相互远离",{"key":26,"text":289,"correct":24},"两个出口应有一个出口对室外",{"key":28,"text":291,"correct":21},"机房出口的门应向室内开",{"id":293,"libraryId":5,"type":8,"typeLabel":15,"stem":294,"options":295,"answer":28,"analysis":20},921828,"高层建筑内柴油发电机房储油间的总储油量不应超过( )h的需要量。",[296,298,300,302],{"key":19,"text":297,"correct":24},"2",{"key":23,"text":299,"correct":24},"4",{"key":26,"text":301,"correct":24},"6",{"key":28,"text":303,"correct":21},"8",{"id":305,"libraryId":5,"type":8,"typeLabel":15,"stem":306,"options":307,"answer":19,"analysis":20},921829,"关于变配电所的布置，下列叙述中哪一个是错误的？( )",[308,310,312,314],{"key":19,"text":309,"correct":21},"不带可燃性油的高低压配电装置和非油浸的电力变压器，不允许布置在同一房间内",{"key":23,"text":311,"correct":24},"高压配电室与值班室应直通或经通道相通",{"key":26,"text":313,"correct":24},"当采用双层布置时，变压器应设在底层",{"key":28,"text":315,"correct":24},"值班室应有直接通向户外或通向走道的门",{"id":317,"libraryId":5,"type":8,"typeLabel":15,"stem":318,"options":319,"answer":19,"analysis":20},921830,"保护接地中，三相五线制是指( )。",[320,322,324,326],{"key":19,"text":321,"correct":21},"TN-S",{"key":23,"text":323,"correct":24},"TN-C",{"key":26,"text":325,"correct":24},"TN-C-S",{"key":28,"text":327,"correct":24},"TT",{"id":329,"libraryId":5,"type":8,"typeLabel":15,"stem":330,"options":331,"answer":19,"analysis":20},921831,"通风和空调管道不宜穿过防火墙和变形缝，必须穿过时，应设的自动关闭的防火阀温度是( )。",[332,334,336,338],{"key":19,"text":333,"correct":21},"700℃",{"key":23,"text":335,"correct":24},"140℃",{"key":26,"text":337,"correct":24},"210℃",{"key":28,"text":339,"correct":24},"280℃",{"id":341,"libraryId":5,"type":8,"typeLabel":15,"stem":342,"options":343,"answer":28,"analysis":20},921832,"冬季空气调节室外计算相对湿度应采用( )。",[344,346,348,350],{"key":19,"text":345,"correct":24},"全年平均相对湿度",{"key":23,"text":347,"correct":24},"累年最冷月最高相对湿度",{"key":26,"text":349,"correct":24},"累年最冷月最低相对湿度",{"key":28,"text":351,"correct":21},"累年最冷月平均相对湿度",{"id":353,"libraryId":5,"type":8,"typeLabel":15,"stem":354,"options":355,"answer":23,"analysis":20},921833,"给水管道和其他管道同沟或共架敷设时，应( )布置。",[356,358,360,362],{"key":19,"text":357,"correct":24},"敷设在排水管下面，热水管下面",{"key":23,"text":359,"correct":21},"敷设在排水管上面，热水管下面",{"key":26,"text":361,"correct":24},"敷设在排水管下面，热水管上面",{"key":28,"text":363,"correct":24},"敷设在排水管上面，热水管上面",{"id":365,"libraryId":5,"type":8,"typeLabel":15,"stem":366,"options":367,"answer":19,"analysis":20},921834,"空调系统的节能运行工况，一年中新风量的变化情况是( )。",[368,370,372,374],{"key":19,"text":369,"correct":21},"冬、夏最小，过渡季节最大",{"key":23,"text":371,"correct":24},"冬、夏、过渡季节最小",{"key":26,"text":373,"correct":24},"冬、夏最大，过渡季节最小",{"key":28,"text":375,"correct":24},"冬、夏、过渡季节最大",{"id":377,"libraryId":5,"type":8,"typeLabel":15,"stem":378,"options":379,"answer":26,"analysis":20},921835,"为了保护居住房间环境卫生，防止下水道的臭气溢出，凡有污水排除的卫生器具均应有水封设施与下水道隔开，下列卫生器具自带水封装置的是( )。",[380,382,384,386],{"key":19,"text":381,"correct":24},"洗面器",{"key":23,"text":383,"correct":24},"洗涤盆",{"key":26,"text":385,"correct":21},"坐式大便器",{"key":28,"text":387,"correct":24},"小便器",{"id":389,"libraryId":5,"type":8,"typeLabel":15,"stem":390,"options":391,"answer":19,"analysis":20},921836,"多层和高层建筑中的消防水池容量分别大于( )m3时，应分设成两个能独立使用的消防水池。",[392,394,396,398],{"key":19,"text":393,"correct":21},"500和500",{"key":23,"text":395,"correct":24},"500和800",{"key":26,"text":397,"correct":24},"800和500",{"key":28,"text":399,"correct":24},"1000和500",{"id":401,"libraryId":5,"type":8,"typeLabel":15,"stem":402,"options":403,"answer":26,"analysis":20},921837,"在选择热源时，当有条件时，应优先选择( )。",[404,406,408,410],{"key":19,"text":405,"correct":24},"蒸汽热源",{"key":23,"text":407,"correct":24},"电力热源",{"key":26,"text":409,"correct":21},"工业余热、废热、地热和太阳能",{"key":28,"text":411,"correct":24},"高温水热源",{"id":413,"libraryId":5,"type":8,"typeLabel":15,"stem":414,"options":415,"answer":19,"analysis":20},921838,"某地新建一栋65m的财贸金融楼，其消火栓充实水柱应为( )。",[416,418,420,422],{"key":19,"text":417,"correct":21},"≮10m",{"key":23,"text":419,"correct":24},"≮11m",{"key":26,"text":421,"correct":24},"≮12m",{"key":28,"text":423,"correct":24},"≮13m",{"id":425,"libraryId":5,"type":8,"typeLabel":15,"stem":426,"options":427,"answer":23,"analysis":20},921839,"有关消防给水系统设置规定，以下正确的是( )。",[428,430,432,434],{"key":19,"text":429,"correct":24},"消防给水不宜与生产管道系统合并",{"key":23,"text":431,"correct":21},"高层工业建筑室内消防给水，应采用独立的消防给水管道系统",{"key":26,"text":433,"correct":24},"生活给水不宜与消防给水管道系统合并",{"key":28,"text":435,"correct":24},"在任何情况下管道必须采用独立管道系统",{"id":437,"libraryId":5,"type":8,"typeLabel":15,"stem":438,"options":439,"answer":19,"analysis":20},921840,"以供给生活饮用水为目的，地表水常规的净水工艺是( )。",[440,442,444,446],{"key":19,"text":441,"correct":21},"混凝→沉淀→过滤→消毒",{"key":23,"text":443,"correct":24},"混凝→沉淀→软化→磁化",{"key":26,"text":445,"correct":24},"混凝→过滤→软化→消毒",{"key":28,"text":447,"correct":24},"混凝→沉淀→软化→过滤",{"id":449,"libraryId":5,"type":8,"typeLabel":15,"stem":450,"options":451,"answer":23,"analysis":20},921841,"给水系统的基本分类不包括( )。",[452,454,456,458],{"key":19,"text":453,"correct":24},"生产给水系统",{"key":23,"text":455,"correct":21},"中水给水系统",{"key":26,"text":457,"correct":24},"生活给水系统",{"key":28,"text":459,"correct":24},"消防给水系统",{"id":461,"libraryId":5,"type":8,"typeLabel":15,"stem":462,"options":463,"answer":28,"analysis":20},921842,"以下叙述哪条正确？( )",[464,466,468,470],{"key":19,"text":465,"correct":24},"卫生间、厨房用水量较大，应靠近贮水池设置",{"key":23,"text":467,"correct":24},"贮水池进出水管的布置没有任何规定和要求",{"key":26,"text":469,"correct":24},"贮水池的进水管和溢流管的口径应当一致",{"key":28,"text":471,"correct":21},"贮水池为了便于清洗和检修，宜分成容积基本相等两格",{"id":473,"libraryId":5,"type":8,"typeLabel":15,"stem":474,"options":475,"answer":23,"analysis":20},921843,"利用金属面做接闪器并需防金属板雷击穿孔时，根据材质要求有一定厚度，下列各项中正确的是( )。",[476,478,480,482],{"key":19,"text":477,"correct":24},"铁板2mm、铜板4mm、铝板Smm",{"key":23,"text":479,"correct":21},"铁板4mm、铜板Smm、铝板7mm",{"key":26,"text":481,"correct":24},"铁板、铜板、铝板均为Smm",{"key":28,"text":483,"correct":24},"铁板Smm、铜板4mm、铝板2mm",{"id":485,"libraryId":5,"type":8,"typeLabel":15,"stem":486,"options":487,"answer":23,"analysis":20},921844,"下列哪一种电气线路敷设的方法是正确的？( )",[488,490,492,494],{"key":19,"text":489,"correct":24},"同一回路的所有相线和中性线不应敷设在同一金属线槽内",{"key":23,"text":491,"correct":21},"同一回路的所有相线和中性线应敷设在同一金属线槽内",{"key":26,"text":493,"correct":24},"三相用电设备采用单芯电线或电缆时，每相电线或电缆应分开敷设在不同的金属线槽内",{"key":28,"text":495,"correct":24},"应急照明和其他照明的线路可以敷设在同一金属管中",{"id":497,"libraryId":5,"type":8,"typeLabel":15,"stem":498,"options":499,"answer":23,"analysis":20},921845,"柴油发电机闾对开门的要求中，哪个是错误的？( )",[500,502,504,506],{"key":19,"text":501,"correct":24},"发电机房应有两个出入口",{"key":23,"text":503,"correct":21},"发电机房同控制室、配电室之间的门和观察窗应有防火隔声措施，门开向控制室、配电室",{"key":26,"text":505,"correct":24},"贮油间同发电机间之间应为防火门，门开向发电机间",{"key":28,"text":507,"correct":24},"发电机房通向外部的门应有防火隔声设施",{"id":509,"libraryId":5,"type":8,"typeLabel":15,"stem":510,"options":511,"answer":26,"analysis":20},921846,"根据建筑物防火等级的分类，超高层建筑应采用下述( )保护方式。",[512,514,516,518],{"key":19,"text":513,"correct":24},"总体",{"key":23,"text":515,"correct":24},"区域",{"key":26,"text":517,"correct":21},"全面",{"key":28,"text":519,"correct":24},"场所",{"id":521,"libraryId":5,"type":8,"typeLabel":15,"stem":522,"options":523,"answer":28,"analysis":20},921847,"某宾馆进行空气调节，采用人工冷源制冷，其制冷方式是( )。",[524,526,528,530],{"key":19,"text":525,"correct":24},"氨压缩式制冷",{"key":23,"text":527,"correct":24},"蒸汽喷射式制冷",{"key":26,"text":529,"correct":24},"溴化锂吸收式制冷或蒸汽喷射式制冷‘",{"key":28,"text":531,"correct":21},"氟里昂压缩式或溴化锂吸收式制冷",{"id":533,"libraryId":5,"type":8,"typeLabel":15,"stem":534,"options":535,"answer":19,"analysis":20},921848,"下列场所中( )的空调系统宜采取双风机系统。",[536,538,540,542],{"key":19,"text":537,"correct":21},"体育馆的比赛大厅",{"key":23,"text":539,"correct":24},"小型展厅",{"key":26,"text":541,"correct":24},"职工餐厅",{"key":28,"text":543,"correct":24},"一般办公室",{"id":545,"libraryId":5,"type":8,"typeLabel":15,"stem":546,"options":547,"answer":28,"analysis":20},921849,"给水引入管的敷设，其室外部分埋设深度影响因素是( )。",[548,550,552,554],{"key":19,"text":549,"correct":24},"工种造价",{"key":23,"text":551,"correct":24},"考虑维修",{"key":26,"text":553,"correct":24},"管径大小",{"key":28,"text":555,"correct":21},"土壤的冰冻深度及地面荷载情况",{"id":557,"libraryId":5,"type":8,"typeLabel":15,"stem":558,"options":559,"answer":19,"analysis":20},921850,"暖风机的安装高度当出口风速≤5m\u002Fs和＞5m\u002Fs时，其安装高度分别为( )。",[560,562,564,566],{"key":19,"text":561,"correct":21},"3～3.5m和4～5.5m",{"key":23,"text":563,"correct":24},"2～2.5m和3～4.5m",{"key":26,"text":565,"correct":24},"4～4.5m和5～6.5m",{"key":28,"text":567,"correct":24},"4～5m和5～6m",{"id":569,"libraryId":5,"type":8,"typeLabel":15,"stem":570,"options":571,"answer":28,"analysis":20},921851,"目前医院污水消毒法常见为( )。",[572,574,576,578],{"key":19,"text":573,"correct":24},"高温(压)蒸煮法、紫外线灭菌法",{"key":23,"text":575,"correct":24},"碳酸法、苛性钠法",{"key":26,"text":577,"correct":24},"臭氧、60钴辐照",{"key":28,"text":579,"correct":21},"加氯法",{"id":581,"libraryId":5,"type":8,"typeLabel":15,"stem":582,"options":583,"answer":28,"analysis":20},921852,"二类防雷建筑物高度超过45m的钢筋混凝土结构、钢结构建筑物，应采取防侧击和等电位的保护措施，以下哪个错误？( )",[584,586,588,590],{"key":19,"text":585,"correct":24},"钢构架和混凝土的钢筋应互相连接",{"key":23,"text":587,"correct":24},"应利用钢柱或柱子钢筋作为防雷装置引下线",{"key":26,"text":589,"correct":24},"应将45m及以上外墙上的栏杆、门窗等较大的金属物与防雷装置连接",{"key":28,"text":591,"correct":21},"竖直敷设的金属管道及金属物的底端与防雷装置连接",{"id":593,"libraryId":5,"type":8,"typeLabel":15,"stem":594,"options":595,"answer":23,"analysis":20},921853,"埋地生活饮用水贮水池与化粪池的净距，不得小于( )m。",[596,597,598,600],{"key":19,"text":261,"correct":24},{"key":23,"text":267,"correct":21},{"key":26,"text":599,"correct":24},"15",{"key":28,"text":132,"correct":24},{"id":602,"libraryId":5,"type":8,"typeLabel":15,"stem":603,"options":604,"answer":28,"analysis":20},921854,"下列游泳池循环次数Ⅳ(次／日)最多的是( )。",[605,607,609,611],{"key":19,"text":606,"correct":24},"比赛池、训练池",{"key":23,"text":608,"correct":24},"跳水池、私用游泳池",{"key":26,"text":610,"correct":24},"儿童池",{"key":28,"text":612,"correct":21},"幼儿戏水池",[614,617,620,623,627,629],{"id":8,"name":615,"category":7,"favorite":616},"领导干部任职前廉政法规知识测试题",92,{"id":618,"name":619,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":621,"name":622,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":624,"name":625,"category":7,"favorite":626},534,"BIM工程师",0,{"id":628,"name":625,"category":7,"favorite":626},535,{"id":630,"name":631,"category":7,"favorite":626},536,"安全人A证"]