[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-51":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,51,50,2979,[13,31,43,55,67,79,91,103,115,127,139,149,161,173,185,197,209,221,233,245,257,269,281,293,305,317,329,341,353,365,375,387,399,411,423,433,445,457,469,479,491,503,515,527,539,551,563,574,586,598],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":19,"analysis":16},921755,"单选题","",[18,22,26,28],{"key":19,"text":20,"correct":21},"A","3",true,{"key":23,"text":24,"correct":25},"B","2",false,{"key":27,"text":20,"correct":25},"C",{"key":29,"text":30,"correct":25},"D","4",{"id":32,"libraryId":5,"type":8,"typeLabel":15,"stem":33,"options":34,"answer":29,"analysis":16},921756,"某建筑室外给水管网中压力经常低于建筑给水系统所需水压、建筑用水量大又不均匀，其解决的办法是( )。",[35,37,39,41],{"key":19,"text":36,"correct":25},"采用直接给水方式",{"key":23,"text":38,"correct":25},"采用由恒速泵从外网抽水增压的给水方式",{"key":27,"text":40,"correct":25},"采用在屋顶上设贮水箱的给水方式",{"key":29,"text":42,"correct":21},"采用贮水池→水→水箱的联合给水方式",{"id":44,"libraryId":5,"type":8,"typeLabel":15,"stem":45,"options":46,"answer":29,"analysis":16},921757,"有传动管网和淋水管网，平时传动管网系统中充满了与进水管中压力相同的水，成组作用阀门由于传动管网的水压作用而紧紧关闭着，火灾发生时，火灾探测器接到火灾信号后，通过电磁阀自动地释放掉传动管网中的压力水，使传动管网中的水压骤然降低，致使成组作用阀门在进水管水压的推动下瞬间开启，自动向淋水管中充水，所有的喷头同时喷水，该系统称( )。",[47,49,51,53],{"key":19,"text":48,"correct":25},"湿式喷水灭火系统",{"key":23,"text":50,"correct":25},"干式喷水灭火系统",{"key":27,"text":52,"correct":25},"预作用喷水灭火系统",{"key":29,"text":54,"correct":21},"雨淋系统",{"id":56,"libraryId":5,"type":8,"typeLabel":15,"stem":57,"options":58,"answer":23,"analysis":16},921758,"循环冷却水系统的控制系统最常用的防腐蚀方法是( )。",[59,61,63,65],{"key":19,"text":60,"correct":25},"阳极或阴极保护法",{"key":23,"text":62,"correct":21},"药剂法",{"key":27,"text":64,"correct":25},"表面涂耐蚀层",{"key":29,"text":66,"correct":25},"改进设备材质防腐",{"id":68,"libraryId":5,"type":8,"typeLabel":15,"stem":69,"options":70,"answer":29,"analysis":16},921759,"在下列情况中，变压器室的门应为防火门的是( )。Ⅰ.变压器室位于高层主体建筑物内；Ⅱ.变压器室位于建筑物的二层；Ⅲ.变压器室位于地下室；Ⅳ，变压器室通向配电装置室的门",[71,73,75,77],{"key":19,"text":72,"correct":25},"Ⅰ",{"key":23,"text":74,"correct":25},"Ⅰ、Ⅱ",{"key":27,"text":76,"correct":25},"Ⅰ、Ⅱ、Ⅲ",{"key":29,"text":78,"correct":21},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"id":80,"libraryId":5,"type":8,"typeLabel":15,"stem":81,"options":82,"answer":23,"analysis":16},921760,"下列因素中( )与节能无关。",[83,85,87,89],{"key":19,"text":84,"correct":25},"体形系数",{"key":23,"text":86,"correct":21},"开间大小",{"key":27,"text":88,"correct":25},"窗墙比",{"key":29,"text":90,"correct":25},"朝向",{"id":92,"libraryId":5,"type":8,"typeLabel":15,"stem":93,"options":94,"answer":19,"analysis":16},921761,"夏热冬冷地区，采用集中空调的建筑中夏季空调时采用冷却塔的作用是( )。",[95,97,99,101],{"key":19,"text":96,"correct":21},"向室外排除建筑内的热量",{"key":23,"text":98,"correct":25},"向各个风机盘管提供冷却水",{"key":27,"text":100,"correct":25},"向各个风机盘管提供空调冷水",{"key":29,"text":102,"correct":25},"向室内提供冷量",{"id":104,"libraryId":5,"type":8,"typeLabel":15,"stem":105,"options":106,"answer":27,"analysis":16},921762,"为了控制低压侧的短路容量和避免因变压器过大对楼板荷载及吊装的不利影响，设置在二层以上的变压器，单台容量不宜大于( )kⅤA。",[107,109,111,113],{"key":19,"text":108,"correct":25},"200",{"key":23,"text":110,"correct":25},"500",{"key":27,"text":112,"correct":21},"630",{"key":29,"text":114,"correct":25},"100",{"id":116,"libraryId":5,"type":8,"typeLabel":15,"stem":117,"options":118,"answer":23,"analysis":16},921763,"散热器不应设置在( )。",[119,121,123,125],{"key":19,"text":120,"correct":25},"外墙窗下",{"key":23,"text":122,"correct":21},"两道外门之间",{"key":27,"text":124,"correct":25},"楼梯间",{"key":29,"text":126,"correct":25},"走道端头",{"id":128,"libraryId":5,"type":8,"typeLabel":15,"stem":129,"options":130,"answer":27,"analysis":16},921764,"钢管连接方法中使连接管不易于拆卸的是( )。",[131,133,135,137],{"key":19,"text":132,"correct":25},"法兰连接",{"key":23,"text":134,"correct":25},"采用活接头连接",{"key":27,"text":136,"correct":21},"焊接",{"key":29,"text":138,"correct":25},"承插连接",{"id":140,"libraryId":5,"type":8,"typeLabel":15,"stem":141,"options":142,"answer":29,"analysis":16},921765,"游泳池给水口池壁配水时，间距不宜超过( )m。",[143,145,146,148],{"key":19,"text":144,"correct":25},"1",{"key":23,"text":24,"correct":25},{"key":27,"text":147,"correct":25},"2，5",{"key":29,"text":20,"correct":21},{"id":150,"libraryId":5,"type":8,"typeLabel":15,"stem":151,"options":152,"answer":23,"analysis":16},921766,"某小型公寓选用的较好的机械循环供暖系统是( )。",[153,155,157,159],{"key":19,"text":154,"correct":25},"双管上供下回式",{"key":23,"text":156,"correct":21},"双管下供下回式",{"key":27,"text":158,"correct":25},"双管中分式",{"key":29,"text":160,"correct":25},"水平单管串联式",{"id":162,"libraryId":5,"type":8,"typeLabel":15,"stem":163,"options":164,"answer":27,"analysis":16},921767,"除尘系统的风管、支管宜从主管的上面或侧面连接，三通管的夹角宜采用( )。",[165,167,169,171],{"key":19,"text":166,"correct":25},"10°～15°",{"key":23,"text":168,"correct":25},"15°～20°",{"key":27,"text":170,"correct":21},"15°～45°",{"key":29,"text":172,"correct":25},"45°",{"id":174,"libraryId":5,"type":8,"typeLabel":15,"stem":175,"options":176,"answer":27,"analysis":16},921768,"依据室内消火栓栓口处的水压限值应采用分区给水系统的条件是( )。",[177,179,181,183],{"key":19,"text":178,"correct":25},"静水压力超过80m水柱时",{"key":23,"text":180,"correct":25},"静水压力等于80m水柱时",{"key":27,"text":182,"correct":21},"静水压力超过100m水柱时",{"key":29,"text":184,"correct":25},"静水压力等于100m水柱时",{"id":186,"libraryId":5,"type":8,"typeLabel":15,"stem":187,"options":188,"answer":27,"analysis":16},921769,"为防止垂直给水管道内的水回流，应安装的阀门是( )。",[189,191,193,195],{"key":19,"text":190,"correct":25},"闸阀",{"key":23,"text":192,"correct":25},"升降式止回阀",{"key":27,"text":194,"correct":21},"旋启式止回阀",{"key":29,"text":196,"correct":25},"截止阀",{"id":198,"libraryId":5,"type":8,"typeLabel":15,"stem":199,"options":200,"answer":27,"analysis":16},921770,"工艺性空气调节房间，对外窗及朝向有如下要求，其中不妥的是( )。",[201,203,205,207],{"key":19,"text":202,"correct":25},"当室温允许波动范围大于±0℃时，外窗应尽量北向",{"key":23,"text":204,"correct":25},"当室温允许波动范围等于±0℃时，不应有东、西向外窗",{"key":27,"text":206,"correct":21},"当室温允许波动范围等于±5℃时，不宜有外窗，如有外窗时，应南向",{"key":29,"text":208,"correct":25},"当室温允许波动范围等于±5℃时，不宜有外窗，如有外窗时，应北向",{"id":210,"libraryId":5,"type":8,"typeLabel":15,"stem":211,"options":212,"answer":29,"analysis":16},921771,"排除生产和生活污水可采用有盖或无盖的排水沟，下列几种排水条件中，( )不能用排水沟排水。",[213,215,217,219],{"key":19,"text":214,"correct":25},"生产设备排水支管很多，用管道连接困难",{"key":23,"text":216,"correct":25},"生产设备排水点的位置不固定",{"key":27,"text":218,"correct":25},"地面需要经常冲洗",{"key":29,"text":220,"correct":21},"污水中含有大量悬浮物并散发有害气体，要经常冲洗",{"id":222,"libraryId":5,"type":8,"typeLabel":15,"stem":223,"options":224,"answer":27,"analysis":16},921772,"高压配电装置各回路的相排列应一致，硬导体的各相应涂色，正确的色别是( )。",[225,227,229,231],{"key":19,"text":226,"correct":25},"A相红色，B相绿色，C相黄色",{"key":23,"text":228,"correct":25},"A相红色，B相黄色，C相绿色",{"key":27,"text":230,"correct":21},"A相黄色，B相绿色，C相红色",{"key":29,"text":232,"correct":25},"A相绿色，B相红色，C相黄色",{"id":234,"libraryId":5,"type":8,"typeLabel":15,"stem":235,"options":236,"answer":27,"analysis":16},921773,"除尘系统的风管不宜采用( )敷设方式。",[237,239,241,243],{"key":19,"text":238,"correct":25},"垂直",{"key":23,"text":240,"correct":25},"向上倾斜",{"key":27,"text":242,"correct":21},"水平",{"key":29,"text":244,"correct":25},"向下倾斜",{"id":246,"libraryId":5,"type":8,"typeLabel":15,"stem":247,"options":248,"answer":27,"analysis":16},921774,"庭院煤气管道不应与室外其他管道同沟敷设，且与其他地下管道的水平净距为( )m。",[249,251,253,255],{"key":19,"text":250,"correct":25},"≮0.5",{"key":23,"text":252,"correct":25},"≮0.8",{"key":27,"text":254,"correct":21},"≮1.0",{"key":29,"text":256,"correct":25},"≮1.5",{"id":258,"libraryId":5,"type":8,"typeLabel":15,"stem":259,"options":260,"answer":27,"analysis":16},921775,"当航空障碍标志灯的安装高度为150m以上时，应选用( )。",[261,263,265,267],{"key":19,"text":262,"correct":25},"带恒定光强的红色灯",{"key":23,"text":264,"correct":25},"带闪光的红色灯",{"key":27,"text":266,"correct":21},"带闪光的白色灯",{"key":29,"text":268,"correct":25},"带闪光的黄色灯",{"id":270,"libraryId":5,"type":8,"typeLabel":15,"stem":271,"options":272,"answer":23,"analysis":16},921776,"对于有高度净化要求的房间，宜采用的气流组织形式是( )。",[273,275,277,279],{"key":19,"text":274,"correct":25},"侧送风",{"key":23,"text":276,"correct":21},"-Ⅰ：L板送风",{"key":27,"text":278,"correct":25},"散流器送风",{"key":29,"text":280,"correct":25},"喷口送风",{"id":282,"libraryId":5,"type":8,"typeLabel":15,"stem":283,"options":284,"answer":29,"analysis":16},921777,"请判断在下述部位中，( )应选择有过滤紫外线功能的灯具。",[285,287,289,291],{"key":19,"text":286,"correct":25},"医院手术室",{"key":23,"text":288,"correct":25},"病房",{"key":27,"text":290,"correct":25},"演播室",{"key":29,"text":292,"correct":21},"藏有珍贵图书和文物的库房",{"id":294,"libraryId":5,"type":8,"typeLabel":15,"stem":295,"options":296,"answer":19,"analysis":16},921778,"通风与空调机房的门防火等级是( )。",[297,299,301,303],{"key":19,"text":298,"correct":21},"甲级",{"key":23,"text":300,"correct":25},"乙级",{"key":27,"text":302,"correct":25},"丙级",{"key":29,"text":304,"correct":25},"无要求",{"id":306,"libraryId":5,"type":8,"typeLabel":15,"stem":307,"options":308,"answer":27,"analysis":16},921779,"依据《人民防空工程设计防火规范》(GB50098-98)，建筑面积大于( )㎡的人防工程其消防用电应按一级负荷要求供电。",[309,311,313,315],{"key":19,"text":310,"correct":25},"2000",{"key":23,"text":312,"correct":25},"4000",{"key":27,"text":314,"correct":21},"5000",{"key":29,"text":316,"correct":25},"6000",{"id":318,"libraryId":5,"type":8,"typeLabel":15,"stem":319,"options":320,"answer":29,"analysis":16},921780,"夏热冬冷地区条式居住建筑的体系数的最大限值为( )。",[321,323,325,327],{"key":19,"text":322,"correct":25},"0.20",{"key":23,"text":324,"correct":25},"0.25",{"key":27,"text":326,"correct":25},"0.30",{"key":29,"text":328,"correct":21},"0.35",{"id":330,"libraryId":5,"type":8,"typeLabel":15,"stem":331,"options":332,"answer":19,"analysis":16},921781,"公共建筑中，可以合用一个全空气空调系统的房间是( )。",[333,335,337,339],{"key":19,"text":334,"correct":21},"演播室与其配套的设备机房",{"key":23,"text":336,"correct":25},"同一朝向且使用时间相同的多个办公室",{"key":27,"text":338,"correct":25},"中餐厅与入口大堂",{"key":29,"text":340,"correct":25},"舞厅和会议室",{"id":342,"libraryId":5,"type":8,"typeLabel":15,"stem":343,"options":344,"answer":23,"analysis":16},921782,"以下关于水箱容积的叙述中，哪条是正确的？( )",[345,347,349,351],{"key":19,"text":346,"correct":25},"生产和生活专用高位水箱容积不能按经验公式确定",{"key":23,"text":348,"correct":21},"生产和生活专用高位水箱调节容积，理论上是根据用水和进水流量变化曲线确定",{"key":27,"text":350,"correct":25},"经验公式计算确定水箱有效容积误差较小",{"key":29,"text":352,"correct":25},"由于外部管网的供水能力相差很大，水箱有效容积不能确定",{"id":354,"libraryId":5,"type":8,"typeLabel":15,"stem":355,"options":356,"answer":19,"analysis":16},921783,"采暖管道设坡度是为了( )。",[357,359,361,363],{"key":19,"text":358,"correct":21},"集气和排气",{"key":23,"text":360,"correct":25},"便于施工",{"key":27,"text":362,"correct":25},"解决热胀冷缩",{"key":29,"text":364,"correct":25},"便于维修",{"id":366,"libraryId":5,"type":8,"typeLabel":15,"stem":367,"options":368,"answer":27,"analysis":16},921784,"排水管起点设置堵头代替清扫口时，堵头与墙面的最小距离为( )m。",[369,370,371,373],{"key":19,"text":324,"correct":25},{"key":23,"text":328,"correct":25},{"key":27,"text":372,"correct":21},"0.40",{"key":29,"text":374,"correct":25},"0，50",{"id":376,"libraryId":5,"type":8,"typeLabel":15,"stem":377,"options":378,"answer":19,"analysis":16},921785,"住宅每户设有沐浴设备，其热水用水定额单位是( )。",[379,381,383,385],{"key":19,"text":380,"correct":21},"每人每日",{"key":23,"text":382,"correct":25},"每床每日",{"key":27,"text":384,"correct":25},"沐浴设备数",{"key":29,"text":386,"correct":25},"每户每日",{"id":388,"libraryId":5,"type":8,"typeLabel":15,"stem":389,"options":390,"answer":29,"analysis":16},921786,"排水通气管出口宜设在( )。",[391,393,395,397],{"key":19,"text":392,"correct":25},"屋檐檐口下",{"key":23,"text":394,"correct":25},"阳台下",{"key":27,"text":396,"correct":25},"雨篷下",{"key":29,"text":398,"correct":21},"屋顶上",{"id":400,"libraryId":5,"type":8,"typeLabel":15,"stem":401,"options":402,"answer":27,"analysis":16},921787,"在下述有关冷却塔的叙述中，正确的是( )。",[403,405,407,409],{"key":19,"text":404,"correct":25},"设在屋顶上，用以贮存冷却水的罐",{"key":23,"text":406,"correct":25},"净化被污染的空气和脱臭的装置",{"key":27,"text":408,"correct":21},"将冷冻机的冷却水所带来的热量向空气中散发的装置",{"key":29,"text":410,"correct":25},"使用冷媒以冷却空气的装置",{"id":412,"libraryId":5,"type":8,"typeLabel":15,"stem":413,"options":414,"answer":29,"analysis":16},921788,"电力系统由( )组成。",[415,417,419,421],{"key":19,"text":416,"correct":25},"发电厂",{"key":23,"text":418,"correct":25},"发电厂、电力网",{"key":27,"text":420,"correct":25},"发电厂、电力网、变配电系统",{"key":29,"text":422,"correct":21},"发电厂、电力网、用户",{"id":424,"libraryId":5,"type":8,"typeLabel":15,"stem":425,"options":426,"answer":23,"analysis":16},921789,"居住区的高压配电应合理设置变电所，以达到低压送电半径在( )m左右。",[427,428,430,431],{"key":19,"text":114,"correct":25},{"key":23,"text":429,"correct":21},"250",{"key":27,"text":110,"correct":25},{"key":29,"text":432,"correct":25},"1000",{"id":434,"libraryId":5,"type":8,"typeLabel":15,"stem":435,"options":436,"answer":27,"analysis":16},921790,"对于热水管汽水同向流动的蒸汽管和凝结水管，坡度宜采用( )。",[437,439,441,443],{"key":19,"text":438,"correct":25},"0.001",{"key":23,"text":440,"correct":25},"0.002",{"key":27,"text":442,"correct":21},"0.003",{"key":29,"text":444,"correct":25},"0.004",{"id":446,"libraryId":5,"type":8,"typeLabel":15,"stem":447,"options":448,"answer":29,"analysis":16},921791,"下述部位中，( )应不设监控用的摄像机。",[449,451,453,455],{"key":19,"text":450,"correct":25},"高级宾馆大厅",{"key":23,"text":452,"correct":25},"电梯轿厢",{"key":27,"text":454,"correct":25},"车库出入口",{"key":29,"text":456,"correct":21},"高级客房",{"id":458,"libraryId":5,"type":8,"typeLabel":15,"stem":459,"options":460,"answer":29,"analysis":16},921792,"下列设备应单独设置在一个房间中的是( )。",[461,463,465,467],{"key":19,"text":462,"correct":25},"不带燃油的高压配电柜",{"key":23,"text":464,"correct":25},"干式变压器",{"key":27,"text":466,"correct":25},"低压配电柜",{"key":29,"text":468,"correct":21},"高压油浸电容器柜",{"id":470,"libraryId":5,"type":8,"typeLabel":15,"stem":471,"options":472,"answer":19,"analysis":16},921793,"热媒为蒸汽时的办公楼采暖系统制式宜为( )。",[473,474,475,477],{"key":19,"text":154,"correct":21},{"key":23,"text":156,"correct":25},{"key":27,"text":476,"correct":25},"双管中供式",{"key":29,"text":478,"correct":25},"单管水平串联式",{"id":480,"libraryId":5,"type":8,"typeLabel":15,"stem":481,"options":482,"answer":29,"analysis":16},921794,"夏季舒适性空气调节室内温度应采用( )。",[483,485,487,489],{"key":19,"text":484,"correct":25},"12℃-14℃",{"key":23,"text":486,"correct":25},"14℃-16℃",{"key":27,"text":488,"correct":25},"18℃-20℃",{"key":29,"text":490,"correct":21},"22℃-28℃",{"id":492,"libraryId":5,"type":8,"typeLabel":15,"stem":493,"options":494,"answer":19,"analysis":16},921795,"对于有线电视系统，选用的设备和部件的输入、输出标称阻抗，电缆的标称特性阻抗均应为( )。",[495,497,499,501],{"key":19,"text":496,"correct":21},"75Q",{"key":23,"text":498,"correct":25},"50Q",{"key":27,"text":500,"correct":25},"100Q",{"key":29,"text":502,"correct":25},"1200",{"id":504,"libraryId":5,"type":8,"typeLabel":15,"stem":505,"options":506,"answer":19,"analysis":16},921796,"通风和空调系统管道的保温材料应为( )。",[507,509,511,513],{"key":19,"text":508,"correct":21},"不燃烧材料或难燃烧材料",{"key":23,"text":510,"correct":25},"难燃烧材料或可燃烧材料",{"key":27,"text":512,"correct":25},"不燃烧材料或可燃烧材料",{"key":29,"text":514,"correct":25},"可燃烧材料",{"id":516,"libraryId":5,"type":8,"typeLabel":15,"stem":517,"options":518,"answer":27,"analysis":16},921797,"布置在民用建筑主体首层、总额定容量不大于1260KⅤ A、单台定额容量不大于630KⅤA的可燃油油浸电力变压器室，其外墙开口部位上方设置的防火挑檐宽度不应小于( )。",[519,521,523,525],{"key":19,"text":520,"correct":25},"0.5M",{"key":23,"text":522,"correct":25},"0.75M",{"key":27,"text":524,"correct":21},"1.00M",{"key":29,"text":526,"correct":25},"1.20M",{"id":528,"libraryId":5,"type":8,"typeLabel":15,"stem":529,"options":530,"answer":27,"analysis":16},921798,"建筑物对感应雷的防护措施为( )。",[531,533,535,537],{"key":19,"text":532,"correct":25},"在屋角、屋脊等处装设避雷带，并加设金属网格",{"key":23,"text":534,"correct":25},"建筑物内钢构架和钢筋混凝土的钢筋应互相连接",{"key":27,"text":536,"correct":21},"建筑物内金属物体接地；金属屋面或屋面的钢筋接成闭合回路接地；建筑物内的竖向金属管道与圈梁钢筋或均压环连接",{"key":29,"text":538,"correct":25},"进入建筑物的电气线路及金属管道全线或部分埋地引入",{"id":540,"libraryId":5,"type":8,"typeLabel":15,"stem":541,"options":542,"answer":23,"analysis":16},921799,"按能效比COP，冷水机组由大到小排列的顺序为( )。",[543,545,547,549],{"key":19,"text":544,"correct":25},"活塞式螺杆式离心式吸收式",{"key":23,"text":546,"correct":21},"离心式螺杆式活塞式吸收式",{"key":27,"text":548,"correct":25},"吸收式螺杆式离心式活塞式",{"key":29,"text":550,"correct":25},"螺杆式活塞式吸收式离心式",{"id":552,"libraryId":5,"type":8,"typeLabel":15,"stem":553,"options":554,"answer":19,"analysis":16},921800,"消防前室的加压送风口应( )设置一个。",[555,557,559,561],{"key":19,"text":556,"correct":21},"每层",{"key":23,"text":558,"correct":25},"隔1层",{"key":27,"text":560,"correct":25},"隔2层",{"key":29,"text":562,"correct":25},"隔3层",{"id":564,"libraryId":5,"type":8,"typeLabel":15,"stem":565,"options":566,"answer":19,"analysis":16},921801,"在水流转角大于( )的污水横管上，应设检查口或清扫口。",[567,568,570,572],{"key":19,"text":172,"correct":21},{"key":23,"text":569,"correct":25},"90°",{"key":27,"text":571,"correct":25},"120°",{"key":29,"text":573,"correct":25},"135°",{"id":575,"libraryId":5,"type":8,"typeLabel":15,"stem":576,"options":577,"answer":27,"analysis":16},921802,"电缆在桥架内敷设时，电缆总截面与桥架横断面面积之比，电力电缆不应大于( )。",[578,580,582,584],{"key":19,"text":579,"correct":25},"20%",{"key":23,"text":581,"correct":25},"300%",{"key":27,"text":583,"correct":21},"40%",{"key":29,"text":585,"correct":25},"50%",{"id":587,"libraryId":5,"type":8,"typeLabel":15,"stem":588,"options":589,"answer":29,"analysis":16},921803,"( )设备宜设漏电保护，自动切断电源。",[590,592,594,596],{"key":19,"text":591,"correct":25},"消防水泵",{"key":23,"text":593,"correct":25},"水灾应急照明",{"key":27,"text":595,"correct":25},"防排烟风机",{"key":29,"text":597,"correct":21},"环境特别恶劣或潮湿场所(如食堂、地下室、浴室)的电气设备",{"id":599,"libraryId":5,"type":8,"typeLabel":15,"stem":600,"options":601,"answer":27,"analysis":16},921804,"高层建筑内的乘客电梯，轿厢内应有应急照明，其连续供电的时间应不少于( )分钟。",[602,604,606,608],{"key":19,"text":603,"correct":25},"10",{"key":23,"text":605,"correct":25},"15",{"key":27,"text":607,"correct":21},"20",{"key":29,"text":609,"correct":25},"30",[611,614,617,620,624,626],{"id":8,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":618,"name":619,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":621,"name":622,"category":7,"favorite":623},534,"BIM工程师",0,{"id":625,"name":622,"category":7,"favorite":623},535,{"id":627,"name":628,"category":7,"favorite":623},536,"安全人A证"]