[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-49":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,49,50,2979,[13,33,45,57,69,81,92,104,116,124,136,148,160,172,184,196,208,220,232,244,256,268,280,292,304,316,328,340,352,364,376,388,400,412,424,434,446,458,470,482,494,506,518,530,542,550,562,574,586,598],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":26,"analysis":32},921655,"单选题","某些纺织厂、印染厂通风系统中含有大量腐蚀性气体和大量水蒸气，宜用( )制作通风管道。",[18,22,25,29],{"key":19,"text":20,"correct":21},"A","普通薄钢板",false,{"key":23,"text":24,"correct":21},"B","铝板",{"key":26,"text":27,"correct":28},"C","玻璃钢板",true,{"key":30,"text":31,"correct":21},"D","镀锌铁皮","",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":35,"options":36,"answer":30,"analysis":32},921656,"对于申间有走廊，房间无吊顶的房间可以采用侧面送风、利用走廊回风的送风方式，当为两侧送风时，走廊两侧墙轴线宽度为( )m。",[37,39,41,43],{"key":19,"text":38,"correct":21},"≥2",{"key":23,"text":40,"correct":21},"≥2.1",{"key":26,"text":42,"correct":21},"≥2.2",{"key":30,"text":44,"correct":28},"≥2.4",{"id":46,"libraryId":5,"type":8,"typeLabel":15,"stem":47,"options":48,"answer":19,"analysis":32},921657,"接闪杆采用热镀锌圆钢或钢管制成，对于其直径的要求，下述哪一条是错误的？( )",[49,51,53,55],{"key":19,"text":50,"correct":28},"当采用圆钢且针长在1m以下时，其直径不应小于8mm",{"key":23,"text":52,"correct":21},"当采用圆钢且针长在1～2m以下时，其直径不应小于16mm",{"key":26,"text":54,"correct":21},"当采用钢管且针长在1m以下时，其直径不应小于20mm",{"key":30,"text":56,"correct":21},"当采用钢管且针长在1～2m以下时，其直径不应小于25mm",{"id":58,"libraryId":5,"type":8,"typeLabel":15,"stem":59,"options":60,"answer":30,"analysis":32},921658,"高压配电室内配电装置距屋顶(梁除外)的距离一般不小于( )m。",[61,63,65,67],{"key":19,"text":62,"correct":21},"0.5",{"key":23,"text":64,"correct":21},"0.6",{"key":26,"text":66,"correct":21},"0.7",{"key":30,"text":68,"correct":28},"0.8",{"id":70,"libraryId":5,"type":8,"typeLabel":15,"stem":71,"options":72,"answer":30,"analysis":32},921659,"重要公共建筑屋面雨水排水的设计重现期不宜小于( )年。",[73,75,77,79],{"key":19,"text":74,"correct":21},"1",{"key":23,"text":76,"correct":21},"3",{"key":26,"text":78,"correct":21},"5",{"key":30,"text":80,"correct":28},"10",{"id":82,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":83,"answer":23,"analysis":32},921660,[84,86,88,90],{"key":19,"text":85,"correct":21},"500",{"key":23,"text":87,"correct":28},"150～200",{"key":26,"text":89,"correct":21},"300～400",{"key":30,"text":91,"correct":21},"250",{"id":93,"libraryId":5,"type":8,"typeLabel":15,"stem":94,"options":95,"answer":26,"analysis":32},921661,"高层民用建筑通风空调风管，下列( )情况可不设防火阀。",[96,98,100,102],{"key":19,"text":97,"correct":21},"穿越防火分区处",{"key":23,"text":99,"correct":21},"穿越通风、空调机房及重要的火灾危险性大的房间隔墙和楼板处",{"key":26,"text":101,"correct":28},"水平总管的分支管段上",{"key":30,"text":103,"correct":21},"穿越变形缝的两侧",{"id":105,"libraryId":5,"type":8,"typeLabel":15,"stem":106,"options":107,"answer":19,"analysis":32},921662,"一级负荷中特别重要负荷，除要求有双重电源外，还必须增设应急电源，下列哪一项不符合应急电源的要求？( )",[108,110,112,114],{"key":19,"text":109,"correct":28},"与市电电源并列运行的发电机组",{"key":23,"text":111,"correct":21},"独立于正常电源的发电机组",{"key":26,"text":113,"correct":21},"供电网络中有效地独立于正常电源的专门馈电线路",{"key":30,"text":115,"correct":21},"蓄电池",{"id":117,"libraryId":5,"type":8,"typeLabel":15,"stem":118,"options":119,"answer":30,"analysis":32},921663,"下列建筑形式有利于采暖节能的是( )(上北下南)。",[120,121,122,123],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":28},{"id":125,"libraryId":5,"type":8,"typeLabel":15,"stem":126,"options":127,"answer":23,"analysis":32},921664,"下列( )不属于电力负荷中的一级负荷。",[128,130,132,134],{"key":19,"text":129,"correct":21},"重要办公楼的客梯电力、主要通道照明",{"key":23,"text":131,"correct":28},"部、省级办公建筑的客梯电力、主要通道照明",{"key":26,"text":133,"correct":21},"大型博物馆的珍贵展品展室的照明",{"key":30,"text":135,"correct":21},"市(地区)级气象台主要业务用电子计算机系统电源",{"id":137,"libraryId":5,"type":8,"typeLabel":15,"stem":138,"options":139,"answer":30,"analysis":32},921665,"设置地漏的房间，地漏的顶面标高，正确的是( )。",[140,142,144,146],{"key":19,"text":141,"correct":21},"设在该房间最低标高处",{"key":23,"text":143,"correct":21},"与地面持平",{"key":26,"text":145,"correct":21},"低于地面10-15mm",{"key":30,"text":147,"correct":28},"低于地面5-10mm",{"id":149,"libraryId":5,"type":8,"typeLabel":15,"stem":150,"options":151,"answer":23,"analysis":32},921666,"按照《建筑设计防火规范》(GB50016-2006)，下列设置闭式自动喷水灭火设备的部位有误的是( )。",[152,154,156,158],{"key":19,"text":153,"correct":21},"超过1500个座位的剧院",{"key":23,"text":155,"correct":28},"每层面积超过2000㎡的办公楼",{"key":26,"text":157,"correct":21},"建筑面积超过3000㎡的商店",{"key":30,"text":159,"correct":21},"藏书量超过50万册的图书馆",{"id":161,"libraryId":5,"type":8,"typeLabel":15,"stem":162,"options":163,"answer":26,"analysis":32},921667,"高层厂房(仓库)和高位消防水箱静压不能满足最不利点消火栓水压要求的其他建筑，应在每个室内消火栓处设置( )，并应有保护设施。",[164,166,168,170],{"key":19,"text":165,"correct":21},"手动报警装置",{"key":23,"text":167,"correct":21},"警铃",{"key":26,"text":169,"correct":28},"直接启动消防水泵的按钮",{"key":30,"text":171,"correct":21},"声光报警装置",{"id":173,"libraryId":5,"type":8,"typeLabel":15,"stem":174,"options":175,"answer":30,"analysis":32},921668,"配变电所在采暖地区，控制室应采暖，采暖计算温度为( )。",[176,178,180,182],{"key":19,"text":177,"correct":21},"5℃",{"key":23,"text":179,"correct":21},"1℃",{"key":26,"text":181,"correct":21},"16℃",{"key":30,"text":183,"correct":28},"18℃",{"id":185,"libraryId":5,"type":8,"typeLabel":15,"stem":186,"options":187,"answer":19,"analysis":32},921669,"分散小空间的空调不应采用( )系统。",[188,190,192,194],{"key":19,"text":189,"correct":28},"集中式",{"key":23,"text":191,"correct":21},"半集中式",{"key":26,"text":193,"correct":21},"分散式",{"key":30,"text":195,"correct":21},"直接蒸发式",{"id":197,"libraryId":5,"type":8,"typeLabel":15,"stem":198,"options":199,"answer":19,"analysis":32},921670,"下面( )不属于安全防范的范畴。",[200,202,204,206],{"key":19,"text":201,"correct":28},"电话系统",{"key":23,"text":203,"correct":21},"防盗报警系统",{"key":26,"text":205,"correct":21},"电脑显示器",{"key":30,"text":207,"correct":21},"大屏投影仪",{"id":209,"libraryId":5,"type":8,"typeLabel":15,"stem":210,"options":211,"answer":19,"analysis":32},921671,"一般公共建筑中，如影院、会堂、商店等常采用的送风方式是( )。",[212,214,216,218],{"key":19,"text":213,"correct":28},"上送式",{"key":23,"text":215,"correct":21},"下送式",{"key":26,"text":217,"correct":21},"单侧式",{"key":30,"text":219,"correct":21},"双侧式",{"id":221,"libraryId":5,"type":8,"typeLabel":15,"stem":222,"options":223,"answer":19,"analysis":32},921672,"按照( )原则，电力负荷应分为一、二、三级负荷。",[224,226,228,230],{"key":19,"text":225,"correct":28},"根据对供电可靠性要求以及中断供电在政治、经济上所造成损失或者髟响的程度进行分级",{"key":23,"text":227,"correct":21},"根据建筑物电力负荷大小进行分级",{"key":26,"text":229,"correct":21},"根据建筑物高度和总建筑面积进行分级",{"key":30,"text":231,"correct":21},"根据建筑物的使用性质",{"id":233,"libraryId":5,"type":8,"typeLabel":15,"stem":234,"options":235,"answer":30,"analysis":32},921673,"在民用建筑的散热器集中供暖系统中应采用( )作为热媒。",[236,238,240,242],{"key":19,"text":237,"correct":21},"高压蒸汽",{"key":23,"text":239,"correct":21},"低压蒸汽",{"key":26,"text":241,"correct":21},"150～90℃热水",{"key":30,"text":243,"correct":28},"75～15℃热水",{"id":245,"libraryId":5,"type":8,"typeLabel":15,"stem":246,"options":247,"answer":30,"analysis":32},921674,"氨制冷机房内严禁采用的采暖方式为( )。",[248,250,252,254],{"key":19,"text":249,"correct":21},"热水集中采暖",{"key":23,"text":251,"correct":21},"蒸汽采暖",{"key":26,"text":253,"correct":21},"热风采暖",{"key":30,"text":255,"correct":28},"火炉采暖",{"id":257,"libraryId":5,"type":8,"typeLabel":15,"stem":258,"options":259,"answer":26,"analysis":32},921675,"确定游泳池水循环周期的根据如下，但其中不必考虑的是( )。",[260,262,264,266],{"key":19,"text":261,"correct":21},"游泳池的使用性质",{"key":23,"text":263,"correct":21},"游泳人数、池水容积",{"key":26,"text":265,"correct":28},"池的形状尺寸",{"key":30,"text":267,"correct":21},"水面面积和池水净化设备运行时间等",{"id":269,"libraryId":5,"type":8,"typeLabel":15,"stem":270,"options":271,"answer":23,"analysis":32},921676,"室内消火栓布置时，一般不能用双出口的消火栓代替两支水枪，但在满足一定条件的普通塔式住宅中，可以只设一条双出口的消火栓，下述条件中正确的是( )。",[272,274,276,278],{"key":19,"text":273,"correct":21},"≤18层、每层≯10户、建筑面积≯850㎡",{"key":23,"text":275,"correct":28},"≤18层、每层≯8户、建筑面积≯650㎡",{"key":26,"text":277,"correct":21},"≤18层、每层≯6户、建筑面积≯500㎡",{"key":30,"text":279,"correct":21},"≤16层、每层≯6户、建筑面积≯500㎡",{"id":281,"libraryId":5,"type":8,"typeLabel":15,"stem":282,"options":283,"answer":19,"analysis":32},921677,"室外消火栓的保护半径不应超过( )；在市政消火栓保护半径150m以内，如消防用水量不超过( )时，可不设室外消火栓。",[284,286,288,290],{"key":19,"text":285,"correct":28},"150m，15L\u002Fs",{"key":23,"text":287,"correct":21},"120m，25L\u002Fs",{"key":26,"text":289,"correct":21},"150m，30L\u002Fs",{"key":30,"text":291,"correct":21},"120m，20L\u002Fs",{"id":293,"libraryId":5,"type":8,"typeLabel":15,"stem":294,"options":295,"answer":26,"analysis":32},921678,"下面( )不属于扩声系统的主要技术指标。",[296,298,300,302],{"key":19,"text":297,"correct":21},"最大声压级",{"key":23,"text":299,"correct":21},"最高可增益",{"key":26,"text":301,"correct":28},"照度",{"key":30,"text":303,"correct":21},"声反馈",{"id":305,"libraryId":5,"type":8,"typeLabel":15,"stem":306,"options":307,"answer":26,"analysis":32},921679,"饮用净水宜采用的供水方式是( )。",[308,310,312,314],{"key":19,"text":309,"correct":21},"水泵-高位水箱供水",{"key":23,"text":311,"correct":21},"水泵-气压水罐供水",{"key":26,"text":313,"correct":28},"调速泵组直接供水",{"key":30,"text":315,"correct":21},"水泵-气压水罐-高位水箱供水",{"id":317,"libraryId":5,"type":8,"typeLabel":15,"stem":318,"options":319,"answer":30,"analysis":32},921680,"压缩机吸气管和排气管的坡度及坡向如下述，其中不妥的是( )。",[320,322,324,326],{"key":19,"text":321,"correct":21},"氟里昂压缩机吸气管坡度不得小于0.01，应坡向压缩机",{"key":23,"text":323,"correct":21},"氨压缩机吸气管坡度不得小于0.003，应坡向蒸发器",{"key":26,"text":325,"correct":21},"压缩机排气管坡度不得小于0.01，应坡向油分离器或冷凝器",{"key":30,"text":327,"correct":28},"氟里昂压缩机、氨压缩机吸气管坡度均不得小于0.003，均坡向压缩机",{"id":329,"libraryId":5,"type":8,"typeLabel":15,"stem":330,"options":331,"answer":30,"analysis":32},921681,"排水架空管道敷设的正确地点是( )。",[332,334,336,338],{"key":19,"text":333,"correct":21},"贵重商品仓库",{"key":23,"text":335,"correct":21},"通风小室",{"key":26,"text":337,"correct":21},"配电间内",{"key":30,"text":339,"correct":28},"无特殊卫生要求生产厂房的天花板下",{"id":341,"libraryId":5,"type":8,"typeLabel":15,"stem":342,"options":343,"answer":30,"analysis":32},921682,"氟里昂压缩式制冷装置布置的位置不宜在( )。",[344,346,348,350],{"key":19,"text":345,"correct":21},"民用建筑内",{"key":23,"text":347,"correct":21},"生产厂房内",{"key":26,"text":349,"correct":21},"辅助建筑内",{"key":30,"text":351,"correct":28},"楼梯间、走廊、大门处",{"id":353,"libraryId":5,"type":8,"typeLabel":15,"stem":354,"options":355,"answer":23,"analysis":32},921683,"民用建筑扬声器在走廊门厅及公共活动场所的背景音乐业务广播应采用( )。",[356,358,360,362],{"key":19,"text":357,"correct":21},"1-2W",{"key":23,"text":359,"correct":28},"3～5W",{"key":26,"text":361,"correct":21},"10W",{"key":30,"text":363,"correct":21},"15W",{"id":365,"libraryId":5,"type":8,"typeLabel":15,"stem":366,"options":367,"answer":19,"analysis":32},921684,"大空间且人员较多或有集中进行温湿度控制的空气调节区域，宜采用的空调系统是( )。",[368,370,372,374],{"key":19,"text":369,"correct":28},"全空气系统",{"key":23,"text":371,"correct":21},"变制冷剂流量多联分体系统",{"key":26,"text":373,"correct":21},"风机盘管系统",{"key":30,"text":375,"correct":21},"诱导器系统",{"id":377,"libraryId":5,"type":8,"typeLabel":15,"stem":378,"options":379,"answer":23,"analysis":32},921685,"污水在化粪池内停留时间，根据污水量多少，采用的停留时间常为( )h。",[380,382,384,386],{"key":19,"text":381,"correct":21},"12",{"key":23,"text":383,"correct":28},"12～24",{"key":26,"text":385,"correct":21},"＞25",{"key":30,"text":387,"correct":21},"30",{"id":389,"libraryId":5,"type":8,"typeLabel":15,"stem":390,"options":391,"answer":19,"analysis":32},921686,"《生活饮用水卫生标准》(GB5749-2006)中汞的含量高限是( )mg\u002FL。",[392,394,396,398],{"key":19,"text":393,"correct":28},"0.001",{"key":23,"text":395,"correct":21},"0.01",{"key":26,"text":397,"correct":21},"0.1",{"key":30,"text":399,"correct":21},"1.0",{"id":401,"libraryId":5,"type":8,"typeLabel":15,"stem":402,"options":403,"answer":19,"analysis":32},921687,"以下这些附件中，( )不用于热水供暖系统。",[404,406,408,410],{"key":19,"text":405,"correct":28},"疏水器",{"key":23,"text":407,"correct":21},"膨胀水箱",{"key":26,"text":409,"correct":21},"集气罐",{"key":30,"text":411,"correct":21},"除污器",{"id":413,"libraryId":5,"type":8,"typeLabel":15,"stem":414,"options":415,"answer":23,"analysis":32},921688,"在暖通专业中，压力的法定单位应是( )。",[416,418,420,422],{"key":19,"text":417,"correct":21},"毫米水柱(mmH20)",{"key":23,"text":419,"correct":28},"帕(Pa)",{"key":26,"text":421,"correct":21},"公斤／米2(kg\u002F㎡)",{"key":30,"text":423,"correct":21},"毫米汞柱(mmHg)",{"id":425,"libraryId":5,"type":8,"typeLabel":15,"stem":426,"options":427,"answer":19,"analysis":32},921689,"《建筑照明设计标准》(GB50034-2004)所规定的照度是指工作面上或者参考平面上的平均维护照蔓，办公室以距地( )m的参考水平面作为工作面。",[428,430,432,433],{"key":19,"text":429,"correct":28},"0，75",{"key":23,"text":431,"correct":21},"0，9",{"key":26,"text":64,"correct":21},{"key":30,"text":399,"correct":21},{"id":435,"libraryId":5,"type":8,"typeLabel":15,"stem":436,"options":437,"answer":26,"analysis":32},921690,"负荷计算中描述错误的是( )。",[438,440,442,444],{"key":19,"text":439,"correct":21},"需要系数法一般用于干线、配变电所的负荷计算",{"key":23,"text":441,"correct":21},"对于断续或短时工作制的电动机的设备功率，当采用需要系数法或二项式法计算时，是将额定功率统一换算到负载持续率为25%时的有功功率",{"key":26,"text":443,"correct":28},"电焊机的设备功率是指将额定功率换算到负载持续率为50%时的有功功率",{"key":30,"text":445,"correct":21},"气体放电灯除灯泡功率外，还应考虑镇流器的功率损耗",{"id":447,"libraryId":5,"type":8,"typeLabel":15,"stem":448,"options":449,"answer":19,"analysis":32},921691,"正压送风系统应保证防烟楼梯的压力是( )Pa。",[450,452,454,456],{"key":19,"text":451,"correct":28},"50",{"key":23,"text":453,"correct":21},"35",{"key":26,"text":455,"correct":21},"25",{"key":30,"text":457,"correct":21},"20",{"id":459,"libraryId":5,"type":8,"typeLabel":15,"stem":460,"options":461,"answer":30,"analysis":32},921692,"下列关于竖井内布线说法错误的是( )。",[462,464,466,468],{"key":19,"text":463,"correct":21},"竖井的井壁应是耐火极限不低于th的非燃烧体",{"key":23,"text":465,"correct":21},"竖井在每层应设维护检修门，并应开向公共走廊",{"key":26,"text":467,"correct":21},"竖井检修门的耐火等级不应低于三级",{"key":30,"text":469,"correct":28},"竖井内的高压、低压和应急电源的电气回路与弱电线路可相邻敷设",{"id":471,"libraryId":5,"type":8,"typeLabel":15,"stem":472,"options":473,"answer":26,"analysis":32},921693,"在高层建筑中，燃油燃气锅炉房应该布置在( )。",[474,476,478,480],{"key":19,"text":475,"correct":21},"建筑的地下三层靠外墙部分",{"key":23,"text":477,"correct":21},"建筑的地下二层靠外墙部分",{"key":26,"text":479,"correct":28},"建筑的首层或者地下一层靠外墙部分",{"key":30,"text":481,"correct":21},"建筑的地上二层靠外墙部分",{"id":483,"libraryId":5,"type":8,"typeLabel":15,"stem":484,"options":485,"answer":26,"analysis":32},921694,"下列配变电所的土建构造要求中( )是错误的。",[486,488,490,492],{"key":19,"text":487,"correct":21},"地(楼)面宜采用高标号水泥抹面压光",{"key":23,"text":489,"correct":21},"电气装置室的顶棚刷白",{"key":26,"text":491,"correct":28},"变压器、配电室的内墙抹灰刷白",{"key":30,"text":493,"correct":21},"电缆间应做防水处理",{"id":495,"libraryId":5,"type":8,"typeLabel":15,"stem":496,"options":497,"answer":26,"analysis":32},921695,"有关自动喷水灭火系统不适用场所，以下错误的是( )。",[498,500,502,504],{"key":19,"text":499,"correct":21},"遇水发生爆炸或加速燃烧的物品场所",{"key":23,"text":501,"correct":21},"遇水发生剧烈化学反应或产生有毒有害物质的物品场所",{"key":26,"text":503,"correct":28},"人员密集不易疏散的场所",{"key":30,"text":505,"correct":21},"洒水将导致喷溅或沸溢的液体场所",{"id":507,"libraryId":5,"type":8,"typeLabel":15,"stem":508,"options":509,"answer":23,"analysis":32},921696,"当金属板下面有易燃物品时，利用金属屋面做接闪器并需防金属板雷击穿孔时，根据材质要求有一定厚度，在下列答案中，哪个是正确的？( )",[510,512,514,516],{"key":19,"text":511,"correct":21},"铁板2mm、铜板4mm、铝板5mm",{"key":23,"text":513,"correct":28},"铁板4mm、铜板5mm、铝板7mm",{"key":26,"text":515,"correct":21},"铁板、铜板、铝板均匀5mm",{"key":30,"text":517,"correct":21},"铁板5mm、铜板4mm、铝板6mm",{"id":519,"libraryId":5,"type":8,"typeLabel":15,"stem":520,"options":521,"answer":26,"analysis":32},921697,"冬季通风室外计算温度应采用( )。",[522,524,526,528],{"key":19,"text":523,"correct":21},"累年最冷月最高温度",{"key":23,"text":525,"correct":21},"累年最冷月最低温度",{"key":26,"text":527,"correct":28},"累年最冷月平均温度",{"key":30,"text":529,"correct":21},"当地最冷年份最冷月的最低温度",{"id":531,"libraryId":5,"type":8,"typeLabel":15,"stem":532,"options":533,"answer":30,"analysis":32},921698,"对电梯及电梯井的以下设计要求中( )是错误的。",[534,536,538,540],{"key":19,"text":535,"correct":21},"高层建筑客梯轿厢内的应急照明，连续供电时间不少于20mⅠn",{"key":23,"text":537,"correct":21},"客梯轿厢内的工作照明灯数不应少于2个",{"key":26,"text":539,"correct":21},"电梯井内应设有照明灯",{"key":30,"text":541,"correct":28},"除向电梯供电的电源线路外，其他线路不得沿电梯井道敷设",{"id":543,"libraryId":5,"type":8,"typeLabel":15,"stem":544,"options":545,"answer":19,"analysis":32},921699,"图示为面积相同、层数相同的建筑物的四种开窗情况，哪一种情况围护结构供暖热负荷较小(上北下南，数字为窗面积)？( )",[546,547,548,549],{"key":19,"text":32,"correct":28},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":21},{"id":551,"libraryId":5,"type":8,"typeLabel":15,"stem":552,"options":553,"answer":30,"analysis":32},921700,"下述建筑中( )要设置火灾报警与消防联动控制系统。",[554,556,558,560],{"key":19,"text":555,"correct":21},"8层的住宅",{"key":23,"text":557,"correct":21},"高度21m的办公室",{"key":26,"text":559,"correct":21},"高度20m的单层剧院",{"key":30,"text":561,"correct":28},"30m高的体育馆",{"id":563,"libraryId":5,"type":8,"typeLabel":15,"stem":564,"options":565,"answer":26,"analysis":32},921701,"居住小区内的高层建筑，宜采用( )低压配电方式。",[566,568,570,572],{"key":19,"text":567,"correct":21},"树干式",{"key":23,"text":569,"correct":21},"环形网络",{"key":26,"text":571,"correct":28},"放射式",{"key":30,"text":573,"correct":21},"综合式",{"id":575,"libraryId":5,"type":8,"typeLabel":15,"stem":576,"options":577,"answer":26,"analysis":32},921702,"以下叙述中错误的是( )。",[578,580,582,584],{"key":19,"text":579,"correct":21},"《生活饮用水卫生标准》是国家现行的生活饮用水的水质标准",{"key":23,"text":581,"correct":21},"生产工艺的要求是确定生产用水水质标准的依据",{"key":26,"text":583,"correct":28},"生活饮用水可以用于任何生产工艺用水",{"key":30,"text":585,"correct":21},"当生活饮用水不能保证用水需要时，可采用非饮用水冲洗卫生器具",{"id":587,"libraryId":5,"type":8,"typeLabel":15,"stem":588,"options":589,"answer":19,"analysis":32},921703,"下列建筑中，( )属于一级电力负荷。",[590,592,594,596],{"key":19,"text":591,"correct":28},"四星级以上的旅馆的经营管理用计算机",{"key":23,"text":593,"correct":21},"大型百货商店的自动扶梯电源",{"key":26,"text":595,"correct":21},"电视台的电视电影室",{"key":30,"text":597,"correct":21},"甲级电影院",{"id":599,"libraryId":5,"type":8,"typeLabel":15,"stem":600,"options":601,"answer":19,"analysis":32},921704,"住宅区热水供暖燃煤锅炉房的运行制度，以下最经济节能的是( )。",[602,604,606,608],{"key":19,"text":603,"correct":28},"24h连续供暖",{"key":23,"text":605,"correct":21},"供暖20h，夜间间歇4h",{"key":26,"text":607,"correct":21},"供暖16h，白天夜间各间歇4h",{"key":30,"text":609,"correct":21},"供暖12h，白天夜间各间歇6h",[611,614,617,620,624,626],{"id":8,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":618,"name":619,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":621,"name":622,"category":7,"favorite":623},534,"BIM工程师",0,{"id":625,"name":622,"category":7,"favorite":623},535,{"id":627,"name":628,"category":7,"favorite":623},536,"安全人A证"]