[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-45":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":557},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,45,50,2979,[13,33,45,57,68,80,92,104,116,127,139,151,158,165,176,183,194,206,218,227,239,246,257,268,280,292,304,312,324,336,347,358,365,377,388,400,412,422,430,442,454,466,477,485,496,507,519,526,534,545],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":29,"analysis":32},921455,"单选题","砂土种类的划分，下列( )说法是正确的。",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","砂土分为粗、中、细砂",false,{"key":23,"text":24,"correct":21},"B","砂土分为粗、中、细、粉砂",{"key":26,"text":27,"correct":21},"C","砂土分为粗、中、粉砂",{"key":29,"text":30,"correct":31},"D","砂土分为砾砂、粗、中、细和粉砂",true,"",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":35,"options":36,"answer":29,"analysis":32},921456,"钢筋混凝土扩展基础，当无垫层时，钢筋保护层的厚度不小于( )mm。",[37,39,41,43],{"key":19,"text":38,"correct":21},"30",{"key":23,"text":40,"correct":21},"40",{"key":26,"text":42,"correct":21},"60",{"key":29,"text":44,"correct":31},"70",{"id":46,"libraryId":5,"type":8,"typeLabel":15,"stem":47,"options":48,"answer":26,"analysis":32},921457,"对钢筋混凝土超筋梁受弯破坏过程，以下( )描述正确。",[49,51,53,55],{"key":19,"text":50,"correct":21},"受拉区钢筋被拉断，而受压区混凝土未压碎",{"key":23,"text":52,"correct":21},"梁支座附近出现450斜裂缝导致梁破坏",{"key":26,"text":54,"correct":31},"受拉区钢筋未屈服，受压区混凝土先压碎",{"key":29,"text":56,"correct":21},"受拉区钢筋先屈服并经过一段流幅后，受压区混凝土压碎",{"id":58,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":59,"answer":23,"analysis":32},921458,[60,62,64,66],{"key":19,"text":61,"correct":21},"刚接",{"key":23,"text":63,"correct":31},"铰接",{"key":26,"text":65,"correct":21},"半刚接",{"key":29,"text":67,"correct":21},"半铰接",{"id":69,"libraryId":5,"type":8,"typeLabel":15,"stem":70,"options":71,"answer":23,"analysis":32},921459,"钢结构柱脚在地面以下的部分应采用混凝土包裹，保护层厚度不应小于50mm，并应使包裹混凝土高出地面至少( )mm。",[72,74,76,78],{"key":19,"text":73,"correct":21},"100",{"key":23,"text":75,"correct":31},"150",{"key":26,"text":77,"correct":21},"200",{"key":29,"text":79,"correct":21},"250",{"id":81,"libraryId":5,"type":8,"typeLabel":15,"stem":82,"options":83,"answer":23,"analysis":32},921460,"从拱的合理拱轴分析，下述属于无推力拱的是( )。",[84,86,88,90],{"key":19,"text":85,"correct":21},"抛物线拱",{"key":23,"text":87,"correct":31},"半圆拱",{"key":26,"text":89,"correct":21},"折线拱",{"key":29,"text":91,"correct":21},"1\u002F4圆拱",{"id":93,"libraryId":5,"type":8,"typeLabel":15,"stem":94,"options":95,"answer":26,"analysis":32},921461,"抗震设防烈度为8度时，现浇钢筋混凝土楼板、屋盖的多层砌体房屋，抗震横墙的最大间距是下列哪一个数值？( )",[96,98,100,102],{"key":19,"text":97,"correct":21},"18m",{"key":23,"text":99,"correct":21},"15m",{"key":26,"text":101,"correct":31},"llm",{"key":29,"text":103,"correct":21},"7m",{"id":105,"libraryId":5,"type":8,"typeLabel":15,"stem":106,"options":107,"answer":29,"analysis":32},921462,"选择建筑场地时，下列哪些地段是对建筑抗震不利的？( )",[108,110,112,114],{"key":19,"text":109,"correct":21},"地震时可能发生滑坡的地段",{"key":23,"text":111,"correct":21},"地震时可能发生崩塌的地段",{"key":26,"text":113,"correct":21},"地震时可能发生地裂的地段",{"key":29,"text":115,"correct":31},"断层破碎带地段",{"id":117,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":118,"answer":26,"analysis":32},921463,[119,121,123,125],{"key":19,"text":120,"correct":21},"杆1",{"key":23,"text":122,"correct":21},"杆2",{"key":26,"text":124,"correct":31},"杆3",{"key":29,"text":126,"correct":21},"杆4",{"id":128,"libraryId":5,"type":8,"typeLabel":15,"stem":129,"options":130,"answer":23,"analysis":32},921464,"以下对抗震设防地区地基土液化的叙述，正确的是( )。Ⅰ.当地基土存在液化土层，桩基的桩端应置于液化土层上面一定距离处；Ⅱ.当地基土中有饱和砂土或饱和粉土时，需要进行液化鉴别；ⅠⅠⅠ.存在液化土层的地基，应根据其液化指数划定液化等级；Ⅳ.对设防烈度7度及7度以下，可不考虑液化判别和地基处理",[131,133,135,137],{"key":19,"text":132,"correct":21},"Ⅰ",{"key":23,"text":134,"correct":31},"Ⅱ、Ⅲ",{"key":26,"text":136,"correct":21},"Ⅳ",{"key":29,"text":138,"correct":21},"Ⅰ、Ⅳ",{"id":140,"libraryId":5,"type":8,"typeLabel":15,"stem":141,"options":142,"answer":26,"analysis":32},921465,"木材强度等级代号(例如TB15)后的数字(如15)，表示其( )强度设计值。",[143,145,147,149],{"key":19,"text":144,"correct":21},"抗拉",{"key":23,"text":146,"correct":21},"抗压",{"key":26,"text":148,"correct":31},"抗弯",{"key":29,"text":150,"correct":21},"抗剪",{"id":152,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":153,"answer":23,"analysis":32},921466,[154,155,156,157],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":31},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":21},{"id":159,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":160,"answer":19,"analysis":32},921467,[161,162,163,164],{"key":19,"text":32,"correct":31},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":21},{"id":166,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":167,"answer":23,"analysis":32},921468,[168,170,172,174],{"key":19,"text":169,"correct":21},"几何可变体系",{"key":23,"text":171,"correct":31},"瞬变体系",{"key":26,"text":173,"correct":21},"无多余联系的几何不变体系",{"key":29,"text":175,"correct":21},"有多余联系的几何不变体系",{"id":177,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":178,"answer":19,"analysis":32},921469,[179,180,181,182],{"key":19,"text":32,"correct":31},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":21},{"id":184,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":185,"answer":23,"analysis":32},921470,[186,188,190,192],{"key":19,"text":187,"correct":21},"4MPa",{"key":23,"text":189,"correct":31},"5MPa",{"key":26,"text":191,"correct":21},"6MPa",{"key":29,"text":193,"correct":21},"7MPa",{"id":195,"libraryId":5,"type":8,"typeLabel":15,"stem":196,"options":197,"answer":19,"analysis":32},921471,"壳体三大功能是( )。",[198,200,202,204],{"key":19,"text":199,"correct":31},"双向受力强度大，刚度大，屋面与承重结构合一",{"key":23,"text":201,"correct":21},"抗震，轻，厚度小",{"key":26,"text":203,"correct":21},"质轻，优美，经济",{"key":29,"text":205,"correct":21},"跨度大，轻，美",{"id":207,"libraryId":5,"type":8,"typeLabel":15,"stem":208,"options":209,"answer":19,"analysis":32},921472,"混凝土强度等级按下列哪一种强度标准值确定？( )",[210,212,214,216],{"key":19,"text":211,"correct":31},"立方体抗压强度",{"key":23,"text":213,"correct":21},"立方体抗拉强度",{"key":26,"text":215,"correct":21},"圆柱体抗拉强度",{"key":29,"text":217,"correct":21},"圆柱体抗压强度",{"id":219,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":220,"answer":29,"analysis":32},921473,[221,223,224,226],{"key":19,"text":222,"correct":21},"Ⅰ、Ⅱ",{"key":23,"text":134,"correct":21},{"key":26,"text":225,"correct":21},"Ⅲ、Ⅳ",{"key":29,"text":138,"correct":31},{"id":228,"libraryId":5,"type":8,"typeLabel":15,"stem":229,"options":230,"answer":26,"analysis":32},921474,"同一结构单元不宜部分采用天然地基部分采用桩基，如不可避免则宜设置( )。",[231,233,235,237],{"key":19,"text":232,"correct":21},"防震缝",{"key":23,"text":234,"correct":21},"伸缩缝",{"key":26,"text":236,"correct":31},"沉降缝",{"key":29,"text":238,"correct":21},"箱形基础",{"id":240,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":241,"answer":19,"analysis":32},921475,[242,243,244,245],{"key":19,"text":32,"correct":31},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":21},{"id":247,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":248,"answer":19,"analysis":32},921476,[249,251,253,255],{"key":19,"text":250,"correct":31},"5、8、9、15",{"key":23,"text":252,"correct":21},"5、9、11、13",{"key":26,"text":254,"correct":21},"9，11、l5、l7",{"key":29,"text":256,"correct":21},"无零杆",{"id":258,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":259,"answer":23,"analysis":32},921477,[260,262,264,266],{"key":19,"text":261,"correct":21},"P",{"key":23,"text":263,"correct":31},"2P",{"key":26,"text":265,"correct":21},"3P",{"key":29,"text":267,"correct":21},"4P",{"id":269,"libraryId":5,"type":8,"typeLabel":15,"stem":270,"options":271,"answer":26,"analysis":32},921478,"半球壳的径向应力为( )。",[272,274,276,278],{"key":19,"text":273,"correct":21},"拉应力",{"key":23,"text":275,"correct":21},"弯矩产生的应力",{"key":26,"text":277,"correct":31},"压应力",{"key":29,"text":279,"correct":21},"扭应力",{"id":281,"libraryId":5,"type":8,"typeLabel":15,"stem":282,"options":283,"answer":29,"analysis":32},921479,"对于存在液化土层的地基，下列( )措施不属于全部消除地基液化沉陷的措施。",[284,286,288,290],{"key":19,"text":285,"correct":21},"采用桩基础，桩端伸入稳定土层",{"key":23,"text":287,"correct":21},"用非液化土替换全部液化土层",{"key":26,"text":289,"correct":21},"采用加密法加固，至液化深度下界",{"key":29,"text":291,"correct":31},"采用箱基、筏基，加强基础的整体性和刚度",{"id":293,"libraryId":5,"type":8,"typeLabel":15,"stem":294,"options":295,"answer":19,"analysis":32},921480,"配筋率适中的钢筋混凝土梁(即适筋梁)，正截面受弯破坏时具有的特征是( )。",[296,298,300,302],{"key":19,"text":297,"correct":31},"延性破坏",{"key":23,"text":299,"correct":21},"脆性破坏",{"key":26,"text":301,"correct":21},"有时延性、有时脆性破坏",{"key":29,"text":303,"correct":21},"破坏时导致斜截面受弯破坏",{"id":305,"libraryId":5,"type":8,"typeLabel":15,"stem":306,"options":307,"answer":29,"analysis":32},921481,"当采用现浇楼盖时，一般多层房屋钢筋混凝土框架柱的计算长度为( )。",[308,309,310,311],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":31},{"id":313,"libraryId":5,"type":8,"typeLabel":15,"stem":314,"options":315,"answer":23,"analysis":32},921482,"短肢剪力墙的墙肢截面高度与厚度之比，正确的是( )。",[316,318,320,322],{"key":19,"text":317,"correct":21},"3-4",{"key":23,"text":319,"correct":31},"5～8",{"key":26,"text":321,"correct":21},"9～10",{"key":29,"text":323,"correct":21},"11～15",{"id":325,"libraryId":5,"type":8,"typeLabel":15,"stem":326,"options":327,"answer":23,"analysis":32},921483,"钢筋混凝土井式楼盖的选用，下列( )说法是适宜的。",[328,330,332,334],{"key":19,"text":329,"correct":21},"两边之比应为l",{"key":23,"text":331,"correct":31},"长边与短边的比不宜大于1.5",{"key":26,"text":333,"correct":21},"长边与短边的比不宜大于2.0",{"key":29,"text":335,"correct":21},"长边与短边的比不宜大于2.5",{"id":337,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":338,"answer":29,"analysis":32},921484,[339,341,343,345],{"key":19,"text":340,"correct":21},"建筑物受到风荷载的大小与高度无关",{"key":23,"text":342,"correct":21},"建筑物越高，受到的风荷载越小",{"key":26,"text":344,"correct":21},"建筑物所受风压与建筑物体型无关",{"key":29,"text":346,"correct":31},"建筑物越高，受到的风荷载越大，但超过450m后趋于稳定",{"id":348,"libraryId":5,"type":8,"typeLabel":15,"stem":349,"options":350,"answer":23,"analysis":32},921485,"计算矩形截面受弯构件及受压构件正截面承载力时，应采用混凝土的( )。",[351,352,354,356],{"key":19,"text":211,"correct":21},{"key":23,"text":353,"correct":31},"轴心抗压强度设计值",{"key":26,"text":355,"correct":21},"轴心抗拉强度标准值",{"key":29,"text":357,"correct":21},"轴心抗压强度标准值",{"id":359,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":360,"answer":26,"analysis":32},921486,[361,362,363,364],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":31},{"key":29,"text":32,"correct":21},{"id":366,"libraryId":5,"type":8,"typeLabel":15,"stem":367,"options":368,"answer":23,"analysis":32},921487,"热轧钢筋经过冷拉之后，其强度和变形性能的变化是( )。",[369,371,373,375],{"key":19,"text":370,"correct":21},"抗拉强度提高，变形性能提高",{"key":23,"text":372,"correct":31},"抗拉强度提高，变形性能降低",{"key":26,"text":374,"correct":21},"抗拉强度、变形性能不变",{"key":29,"text":376,"correct":21},"抗拉强度提高，变形性能不变",{"id":378,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":379,"answer":23,"analysis":32},921488,[380,382,384,386],{"key":19,"text":381,"correct":21},"P(↓)",{"key":23,"text":383,"correct":31},"P(↑)",{"key":26,"text":385,"correct":21},"2P(↓)",{"key":29,"text":387,"correct":21},"2P(↑)",{"id":389,"libraryId":5,"type":8,"typeLabel":15,"stem":390,"options":391,"answer":26,"analysis":32},921489,"钢筋混凝土结构构件的配筋率计算与以下( )因素无关。",[392,394,396,398],{"key":19,"text":393,"correct":21},"构件截面尺寸",{"key":23,"text":395,"correct":21},"构件截面高度",{"key":26,"text":397,"correct":31},"构件的跨度",{"key":29,"text":399,"correct":21},"构件的钢筋面积",{"id":401,"libraryId":5,"type":8,"typeLabel":15,"stem":402,"options":403,"answer":29,"analysis":32},921490,"下列情况中属于复杂高层建筑的是( )。",[404,406,408,410],{"key":19,"text":405,"correct":21},"结构平面凹进的一侧尺寸，大于相应投影方向总尺寸的30%",{"key":23,"text":407,"correct":21},"混凝土简体结构",{"key":26,"text":409,"correct":21},"楼层的侧向刚度小于相邻上一层的70%",{"key":29,"text":411,"correct":31},"多塔楼结构",{"id":413,"libraryId":5,"type":8,"typeLabel":15,"stem":414,"options":415,"answer":23,"analysis":32},921491,"抗震设计时，关于单层钢筋混凝土柱厂房的做法合理的是( )。Ⅰ.厂房端部可采用山墙承重，不设屋面梁；Ⅱ.厂房内上吊车的铁梯不应靠近防震缝设置；Ⅲ.阶形柱的上柱采用矩形平面；Ⅳ.有突出屋面的天窗时可采用预应力混凝土空腹屋架",[416,417,418,420],{"key":19,"text":138,"correct":21},{"key":23,"text":134,"correct":31},{"key":26,"text":419,"correct":21},"Ⅰ、Ⅲ",{"key":29,"text":421,"correct":21},"Ⅱ、Ⅳ",{"id":423,"libraryId":5,"type":8,"typeLabel":15,"stem":424,"options":425,"answer":26,"analysis":32},921492,"图示结构弯矩图正确身( )。",[426,427,428,429],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":31},{"key":29,"text":32,"correct":21},{"id":431,"libraryId":5,"type":8,"typeLabel":15,"stem":432,"options":433,"answer":26,"analysis":32},921493,"周边支承的三角锥网架或三向网架，一般使用于下列( )建筑平面形状。",[434,436,438,440],{"key":19,"text":435,"correct":21},"矩形(当边长比大于1.5时)",{"key":23,"text":437,"correct":21},"矩形(当边长比大于2时)",{"key":26,"text":439,"correct":31},"正六边形",{"key":29,"text":441,"correct":21},"椭圆形",{"id":443,"libraryId":5,"type":8,"typeLabel":15,"stem":444,"options":445,"answer":26,"analysis":32},921494,"高层钢筋混凝土建筑楼板开洞总面积与楼面面积的比值不宜超过( )。",[446,448,450,452],{"key":19,"text":447,"correct":21},"20%",{"key":23,"text":449,"correct":21},"2570",{"key":26,"text":451,"correct":31},"30%",{"key":29,"text":453,"correct":21},"50%",{"id":455,"libraryId":5,"type":8,"typeLabel":15,"stem":456,"options":457,"answer":26,"analysis":32},921495,"在高强度螺栓摩擦型抗剪连接中，螺栓的承载力极限状态是( )。",[458,460,462,464],{"key":19,"text":459,"correct":21},"螺栓杆被剪坏",{"key":23,"text":461,"correct":21},"钢板孔壁被压坏",{"key":26,"text":463,"correct":31},"连接处钢板接触面间出现相对滑移",{"key":29,"text":465,"correct":21},"螺栓杆被剪坏同时钢板孔壁被压坏",{"id":467,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":468,"answer":23,"analysis":32},921496,[469,471,473,475],{"key":19,"text":470,"correct":21},"2kN·m",{"key":23,"text":472,"correct":31},"4kN·m",{"key":26,"text":474,"correct":21},"6kN·m",{"key":29,"text":476,"correct":21},"8kN·m",{"id":478,"libraryId":5,"type":8,"typeLabel":15,"stem":479,"options":480,"answer":23,"analysis":32},921497,"接弹性理论，四边支承板在满足下列( )项条件时应按双向板设计。",[481,482,483,484],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":31},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":21},{"id":486,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":487,"answer":26,"analysis":32},921498,[488,490,492,494],{"key":19,"text":489,"correct":21},"20kN·m",{"key":23,"text":491,"correct":21},"25kN·m",{"key":26,"text":493,"correct":31},"30kN·m",{"key":29,"text":495,"correct":21},"40kN·m",{"id":497,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":498,"answer":23,"analysis":32},921499,[499,501,503,505],{"key":19,"text":500,"correct":21},"静定结构",{"key":23,"text":502,"correct":31},"一次超静定结构",{"key":26,"text":504,"correct":21},"二次超静定结构",{"key":29,"text":506,"correct":21},"三次超静定结构",{"id":508,"libraryId":5,"type":8,"typeLabel":15,"stem":509,"options":510,"answer":23,"analysis":32},921500,"钢筋混凝土双向密肋楼盖的肋间距，下列( )数值范围较为合理。",[511,513,515,517],{"key":19,"text":512,"correct":21},"400-600mm",{"key":23,"text":514,"correct":31},"700-1000mm",{"key":26,"text":516,"correct":21},"1200-1500mm",{"key":29,"text":518,"correct":21},"1600-2000mm",{"id":520,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":521,"answer":26,"analysis":32},921501,[522,523,524,525],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":31},{"key":29,"text":32,"correct":21},{"id":527,"libraryId":5,"type":8,"typeLabel":15,"stem":528,"options":529,"answer":23,"analysis":32},921502,"有抗震要求的长矩形多层砌体房屋，应优先采用( )。Ⅰ.横墙承重；Ⅱ.纵墙承重；Ⅲ.纵横墙共同承重；Ⅳ.柱及带壁柱承重",[530,531,532,533],{"key":19,"text":134,"correct":21},{"key":23,"text":419,"correct":31},{"key":26,"text":421,"correct":21},{"key":29,"text":138,"correct":21},{"id":535,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":536,"answer":29,"analysis":32},921503,[537,539,541,543],{"key":19,"text":538,"correct":21},"所有杆件内力均不为零",{"key":23,"text":540,"correct":21},"AB杆内力不为零，其他杆为零",{"key":26,"text":542,"correct":21},"BC杆内力不为零，其他杆为零",{"key":29,"text":544,"correct":31},"CD杆内力不为零，其他杆为零",{"id":546,"libraryId":5,"type":8,"typeLabel":15,"stem":547,"options":548,"answer":26,"analysis":32},921504,"关于变形缝的做法，以下叙述不正确的是( )。",[549,551,553,555],{"key":19,"text":550,"correct":21},"伸缩缝应沿房屋全高设置，地下室、基础可不设缝",{"key":23,"text":552,"correct":21},"防震缝应沿房屋全高设置，地下室、基础可不设缝",{"key":26,"text":554,"correct":31},"沉降缝应沿房屋全高设置，地下室、基础可不设缝",{"key":29,"text":556,"correct":21},"沉降缝应沿房屋全高设置，地下室、基础亦应设缝",[558,561,564,567,571,573],{"id":8,"name":559,"category":7,"favorite":560},"领导干部任职前廉政法规知识测试题",92,{"id":562,"name":563,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":565,"name":566,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":568,"name":569,"category":7,"favorite":570},534,"BIM工程师",0,{"id":572,"name":569,"category":7,"favorite":570},535,{"id":574,"name":575,"category":7,"favorite":570},536,"安全人A证"]