[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-39":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":562},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,39,50,2979,[13,28,39,50,61,71,82,94,106,118,130,141,153,165,176,187,195,203,215,222,233,240,252,264,274,286,298,305,315,326,337,349,361,373,385,397,409,421,428,439,446,458,468,480,492,504,516,526,538,550],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":24,"analysis":16},921155,"单选题","",[18,21,23,26],{"key":19,"text":16,"correct":20},"A",false,{"key":22,"text":16,"correct":20},"B",{"key":24,"text":16,"correct":25},"C",true,{"key":27,"text":16,"correct":20},"D",{"id":29,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":30,"answer":19,"analysis":16},921156,[31,33,35,37],{"key":19,"text":32,"correct":25},"温度升高后，钢管不产生温度应力",{"key":22,"text":34,"correct":20},"产生温度应力，其应力值与t△成正比",{"key":24,"text":36,"correct":20},"产生温度应力，其应力值与L成正比",{"key":27,"text":38,"correct":20},"伸长值△f与△t成正比，但△l与L无关",{"id":40,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":41,"answer":22,"analysis":16},921157,[42,44,46,48],{"key":19,"text":43,"correct":20},"Ⅰ、Ⅲ",{"key":22,"text":45,"correct":25},"Ⅱ、Ⅲ",{"key":24,"text":47,"correct":20},"Ⅰ、Ⅳ",{"key":27,"text":49,"correct":20},"Ⅱ、Ⅳ",{"id":51,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":52,"answer":19,"analysis":16},921158,[53,55,57,59],{"key":19,"text":54,"correct":25},"整个刚架无弯矩",{"key":22,"text":56,"correct":20},"整个刚架都有弯矩",{"key":24,"text":58,"correct":20},"横梁无弯矩，柱有弯矩",{"key":27,"text":60,"correct":20},"横梁有弯矩，柱无弯矩",{"id":62,"libraryId":5,"type":8,"typeLabel":15,"stem":63,"options":64,"answer":19,"analysis":16},921159,"有抗震要求的单层砖柱房屋，其屋盖形式的选用，正确的是( )。Ⅰ.6-8度时宜采用轻型屋盖；Ⅱ.9度时应采用轻型屋盖；Ⅲ.6～8度时宜采用重型屋盖；Ⅳ.9度时应采用重型屋盖",[65,67,68,69],{"key":19,"text":66,"correct":25},"Ⅰ、Ⅱ",{"key":22,"text":45,"correct":20},{"key":24,"text":43,"correct":20},{"key":27,"text":70,"correct":20},"Ⅲ、Ⅳ",{"id":72,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":73,"answer":22,"analysis":16},921160,[74,76,78,80],{"key":19,"text":75,"correct":20},"顺时针转动",{"key":22,"text":77,"correct":25},"逆时针转动",{"key":24,"text":79,"correct":20},"无转动",{"key":27,"text":81,"correct":20},"不能确定",{"id":83,"libraryId":5,"type":8,"typeLabel":15,"stem":84,"options":85,"answer":27,"analysis":16},921161,"关于设置屋架支撑的作用，下列叙述中不正确的是( )。",[86,88,90,92],{"key":19,"text":87,"correct":20},"防止屋架侧倾",{"key":22,"text":89,"correct":20},"保证受压弦杆的侧向稳定",{"key":24,"text":91,"correct":20},"承担和传递纵向水平力",{"key":27,"text":93,"correct":25},"承担和传递屋面荷载",{"id":95,"libraryId":5,"type":8,"typeLabel":15,"stem":96,"options":97,"answer":27,"analysis":16},921162,"关于螺栓和铆钉连接，下列说法中与规范不符的是( )。",[98,100,102,104],{"key":19,"text":99,"correct":20},"每一杆件在节点上以及拼接接头的一端，永久性螺栓(或铆钉)数不宜少于两个",{"key":22,"text":101,"correct":20},"在高强度螺栓连接范围内，构件接触面的处理方法应在施工图上说明",{"key":24,"text":103,"correct":20},"对直接承受动力荷载的普通螺栓连接应采用双螺母或其他防止螺母松动的有效措施",{"key":27,"text":105,"correct":25},"沉头和半沉头铆钉可用于沿其杆轴方向受拉的连接",{"id":107,"libraryId":5,"type":8,"typeLabel":15,"stem":108,"options":109,"answer":27,"analysis":16},921163,"抗震设计的多层砌体房屋的结构体系，下例要求不正确的是( )。",[110,112,114,116],{"key":19,"text":111,"correct":20},"应优先采用横墙承重或纵横墙共同承重的结构体系",{"key":22,"text":113,"correct":20},"纵横墙的布置宜均匀对称，沿平面内宜对齐，沿竖向应上下连续",{"key":24,"text":115,"correct":20},"同一轴线上的窗间墙宽度宜均匀",{"key":27,"text":117,"correct":25},"楼梯间宜设置在房屋的尽端和转角处",{"id":119,"libraryId":5,"type":8,"typeLabel":15,"stem":120,"options":121,"answer":27,"analysis":16},921164,"高层建筑中钢筋混凝土框架梁的截面宽度不应小于( )。",[122,124,126,128],{"key":19,"text":123,"correct":20},"350mm",{"key":22,"text":125,"correct":20},"300mm",{"key":24,"text":127,"correct":20},"250mm",{"key":27,"text":129,"correct":25},"200mm",{"id":131,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":132,"answer":22,"analysis":16},921165,[133,135,137,139],{"key":19,"text":134,"correct":20},"向上",{"key":22,"text":136,"correct":25},"向下",{"key":24,"text":138,"correct":20},"向左",{"key":27,"text":140,"correct":20},"向右",{"id":142,"libraryId":5,"type":8,"typeLabel":15,"stem":143,"options":144,"answer":27,"analysis":16},921166,"抗震设计时，下列选用的建筑非承重墙体材料不妥当的是( )。",[145,147,149,151],{"key":19,"text":146,"correct":20},"混凝土结构和钢结构应优先采用轻质墙体材料",{"key":22,"text":148,"correct":20},"单层钢筋混凝土柱厂房的围护墙宜采用轻质墙板或钢筋混凝土大型墙板",{"key":24,"text":150,"correct":20},"钢结构厂房的围护墙不应采用嵌砌砌体墙",{"key":27,"text":152,"correct":25},"9度时钢结构厂房的围护墙必须采用轻质墙板",{"id":154,"libraryId":5,"type":8,"typeLabel":15,"stem":155,"options":156,"answer":22,"analysis":16},921167,"在挡土墙设计中，可以不必进行的验算为( )。",[157,159,161,163],{"key":19,"text":158,"correct":20},"地基承载力验算",{"key":22,"text":160,"correct":25},"地基变形计算",{"key":24,"text":162,"correct":20},"抗滑移验算",{"key":27,"text":164,"correct":20},"抗倾覆验算",{"id":166,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":167,"answer":22,"analysis":16},921168,[168,170,172,174],{"key":19,"text":169,"correct":20},"弯矩和剪力",{"key":22,"text":171,"correct":25},"轴力",{"key":24,"text":173,"correct":20},"弯矩和轴力",{"key":27,"text":175,"correct":20},"剪力",{"id":177,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":178,"answer":27,"analysis":16},921169,[179,181,183,185],{"key":19,"text":180,"correct":20},"各杆内力均为0",{"key":22,"text":182,"correct":20},"各杆内力均不为0",{"key":24,"text":184,"correct":20},"仅BC杆内力为0",{"key":27,"text":186,"correct":25},"仅BC杆内力不为0",{"id":188,"libraryId":5,"type":8,"typeLabel":15,"stem":189,"options":190,"answer":27,"analysis":16},921170,"图示结构中，所有杆件截面、材料均相同，跨度、荷载相同，则下面各图中哪个图bc杆轴力最小？( )",[191,192,193,194],{"key":19,"text":16,"correct":20},{"key":22,"text":16,"correct":20},{"key":24,"text":16,"correct":20},{"key":27,"text":16,"correct":25},{"id":196,"libraryId":5,"type":8,"typeLabel":15,"stem":197,"options":198,"answer":19,"analysis":16},921171,"对抗风结构和抗震结构布置特点叙述，正确的是( )。Ⅰ.对抗风结构，增大结构侧向刚度和房屋结构重量对抗风作用有利；Ⅱ.对抗风结构，减轻房屋重量，对抗风作用有利；Ⅲ.对抗震结构，结构自重轻，侧向刚度小，周期长，将使地震作用减小；Ⅳ.对抗震结构，增大结构侧向刚度和房屋结构重量对抗震作用有利",[199,200,201,202],{"key":19,"text":43,"correct":25},{"key":22,"text":49,"correct":20},{"key":24,"text":47,"correct":20},{"key":27,"text":45,"correct":20},{"id":204,"libraryId":5,"type":8,"typeLabel":15,"stem":205,"options":206,"answer":22,"analysis":16},921172,"下列关于网架结构的叙述，不正确的是( )。",[207,209,211,213],{"key":19,"text":208,"correct":20},"网架按外形分类有平面网架和曲面网架",{"key":22,"text":210,"correct":25},"平面网架可以是单层的，也可以是双层的",{"key":24,"text":212,"correct":20},"曲面网架可以是单层的，也可以是双层的",{"key":27,"text":214,"correct":20},"曲面网架可以做成单曲或双曲的",{"id":216,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":217,"answer":19,"analysis":16},921173,[218,219,220,221],{"key":19,"text":43,"correct":25},{"key":22,"text":45,"correct":20},{"key":24,"text":47,"correct":20},{"key":27,"text":49,"correct":20},{"id":223,"libraryId":5,"type":8,"typeLabel":15,"stem":224,"options":225,"answer":19,"analysis":16},921174,"《钢结构设计规范》(GB50017-2003)中推荐使用的钢材是( )。 A.Q235，Q390，Q345，Q420",[226,228,229,231],{"key":19,"text":227,"correct":25},"25MnSⅠ，Q235-B·F",{"key":22,"text":16,"correct":20},{"key":24,"text":230,"correct":20},"45号钢，Q235-B·",{"key":27,"text":232,"correct":20},"15MnTⅠ",{"id":234,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":235,"answer":27,"analysis":16},921175,[236,237,238,239],{"key":19,"text":16,"correct":20},{"key":22,"text":16,"correct":20},{"key":24,"text":16,"correct":20},{"key":27,"text":16,"correct":25},{"id":241,"libraryId":5,"type":8,"typeLabel":15,"stem":242,"options":243,"answer":22,"analysis":16},921176,"《键筑抗震设计规范》(GB50011-2001)规定，对于黏土砖砌体承重的房屋，当设防烈度为9度时，房屋总层数的限值为( )层。",[244,246,248,250],{"key":19,"text":245,"correct":20},"5",{"key":22,"text":247,"correct":25},"4",{"key":24,"text":249,"correct":20},"3",{"key":27,"text":251,"correct":20},"2",{"id":253,"libraryId":5,"type":8,"typeLabel":15,"stem":254,"options":255,"answer":22,"analysis":16},921177,"悬索结构支座承受( )。",[256,258,260,262],{"key":19,"text":257,"correct":20},"压力",{"key":22,"text":259,"correct":25},"拉力",{"key":24,"text":261,"correct":20},"力矩",{"key":27,"text":263,"correct":20},"扭矩",{"id":265,"libraryId":5,"type":8,"typeLabel":15,"stem":266,"options":267,"answer":22,"analysis":16},921178,"《高层建筑混凝土结构技术规程》(JGJ3-2002)规定，抗震设防烈度为8度时，高层剪力墙结构房屋的高宽比不宜超过( )。",[268,269,270,272],{"key":19,"text":247,"correct":20},{"key":22,"text":245,"correct":25},{"key":24,"text":271,"correct":20},"6",{"key":27,"text":273,"correct":20},"7",{"id":275,"libraryId":5,"type":8,"typeLabel":15,"stem":276,"options":277,"answer":22,"analysis":16},921179,"有关砌体防潮层的设置，下列叙述错误的是( )。",[278,280,282,284],{"key":19,"text":279,"correct":20},"设置在室内地面以下",{"key":22,"text":281,"correct":25},"设置在室外散水坡顶面以下",{"key":24,"text":283,"correct":20},"勒脚采用水泥砂浆",{"key":27,"text":285,"correct":20},"对防潮层以下砌体材料最低等级，规范有专门规定",{"id":287,"libraryId":5,"type":8,"typeLabel":15,"stem":288,"options":289,"answer":24,"analysis":16},921180,"有关钢材的对接焊缝能承受的内力，下列说法正确的是( )。",[290,292,294,296],{"key":19,"text":291,"correct":20},"能承受拉力和剪力",{"key":22,"text":293,"correct":20},"能承受拉力，不能承受弯矩",{"key":24,"text":295,"correct":25},"能承受拉力、剪力和弯矩",{"key":27,"text":297,"correct":20},"只能承受拉力",{"id":299,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":300,"answer":27,"analysis":16},921181,[301,302,303,304],{"key":19,"text":16,"correct":20},{"key":22,"text":16,"correct":20},{"key":24,"text":16,"correct":20},{"key":27,"text":16,"correct":25},{"id":306,"libraryId":5,"type":8,"typeLabel":15,"stem":307,"options":308,"answer":24,"analysis":16},921182,"为增强整体刚度，在软弱地基上的多层砌体房屋，其长高比(房屋长度与高度之比)宜小于或等于( )。",[309,310,311,313],{"key":19,"text":249,"correct":20},{"key":22,"text":251,"correct":20},{"key":24,"text":312,"correct":25},"2.5",{"key":27,"text":314,"correct":20},"1.5",{"id":316,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":317,"answer":22,"analysis":16},921183,[318,320,322,324],{"key":19,"text":319,"correct":20},"1：2",{"key":22,"text":321,"correct":25},"2：3",{"key":24,"text":323,"correct":20},"2：5",{"key":27,"text":325,"correct":20},"3：4",{"id":327,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":328,"answer":27,"analysis":16},921184,[329,331,333,335],{"key":19,"text":330,"correct":20},"A处支反力大于B处支反力",{"key":22,"text":332,"correct":20},"A处支反力为零",{"key":24,"text":334,"correct":20},"两处支反力均向上",{"key":27,"text":336,"correct":25},"荷载P向左移时，B处支反力变小",{"id":338,"libraryId":5,"type":8,"typeLabel":15,"stem":339,"options":340,"answer":19,"analysis":16},921185,"计算挡土墙的土压力时，对会向外(非挡土一侧)移动或转动的挡土墙，应采用( )。",[341,343,345,347],{"key":19,"text":342,"correct":25},"主动土压力",{"key":22,"text":344,"correct":20},"主动土压力的1\u002F2",{"key":24,"text":346,"correct":20},"静止土压力",{"key":27,"text":348,"correct":20},"被动土压力",{"id":350,"libraryId":5,"type":8,"typeLabel":15,"stem":351,"options":352,"answer":24,"analysis":16},921186,"在软弱地基上建房时，对体型复杂荷载差异较大的框架结构可选用( )。",[353,355,357,359],{"key":19,"text":354,"correct":20},"独立柱基加基础拉梁",{"key":22,"text":356,"correct":20},"钢筋混凝土条形基础",{"key":24,"text":358,"correct":25},"箱基、桩基、筏基",{"key":27,"text":360,"correct":20},"壳体基础",{"id":362,"libraryId":5,"type":8,"typeLabel":15,"stem":363,"options":364,"answer":22,"analysis":16},921187,"框架房屋和框架一抗震墙房屋，当高度不超过15m时，可采用70mm抗震缝，当高度超过15m时，缝宽应满足( )。",[365,367,369,371],{"key":19,"text":366,"correct":20},"设防烈度为6度、7度、8度和9度时相应每增加4m、3m、2m、Ⅰm，缝宜加宽20mm",{"key":22,"text":368,"correct":25},"设防烈度为6度、7度、8度和9度时相应每增加Sm、4m、3m、2m，缝宜加宽20mm",{"key":24,"text":370,"correct":20},"设防烈度为6度、7度、8度和9度时相应每增加4m、3m、2m、Ⅰm，缝宜加宽30mm",{"key":27,"text":372,"correct":20},"设防烈度为6度、7度、8度和9度时相应每增加Sm、4m、3m、2m，缝宜加宽30mm",{"id":374,"libraryId":5,"type":8,"typeLabel":15,"stem":375,"options":376,"answer":24,"analysis":16},921188,"当厂房用砖墙作为围护墙体时，一般需设置圈梁，圈梁的作用是( )。Ⅰ.将墙体、柱及抗风柱箍在一起，增加厂房的整体刚度；Ⅱ，防止发生过大的不均匀沉降；Ⅲ.支撑墙体重量；Ⅳ.防止由于较大振动荷载引起的不利影响",[377,379,381,383],{"key":19,"text":378,"correct":20},"Ⅰ、Ⅲ，",{"key":22,"text":380,"correct":20},"Ⅰ、Ⅱ、Ⅲ",{"key":24,"text":382,"correct":25},"Ⅰ、Ⅱ、Ⅳ",{"key":27,"text":384,"correct":20},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"id":386,"libraryId":5,"type":8,"typeLabel":15,"stem":387,"options":388,"answer":22,"analysis":16},921189,"根据《地基基础设计规范》，下列建筑物的桩基可不进行沉降验算的是( )o",[389,391,393,395],{"key":19,"text":390,"correct":20},"地基基础设计等级为甲级的建筑物",{"key":22,"text":392,"correct":25},"桩基以下存在软弱土层的设计等级为丙级的建筑物",{"key":24,"text":394,"correct":20},"摩擦型桩基",{"key":27,"text":396,"correct":20},"体型复杂的设计等级为乙级的建筑物",{"id":398,"libraryId":5,"type":8,"typeLabel":15,"stem":399,"options":400,"answer":19,"analysis":16},921190,"按一、二级抗震等级设计时，框架结构中纵向受力钢筋的抗拉强度实测值与屈服强度实测值的比值，不应小于( )。",[401,403,405,407],{"key":19,"text":402,"correct":25},"1.25",{"key":22,"text":404,"correct":20},"1.50",{"key":24,"text":406,"correct":20},"1.80",{"key":27,"text":408,"correct":20},"2.00",{"id":410,"libraryId":5,"type":8,"typeLabel":15,"stem":411,"options":412,"answer":24,"analysis":16},921191,"顶层带楼阁的坡屋面砌体结构房屋，其房屋总高度应按( )计算。",[413,415,417,419],{"key":19,"text":414,"correct":20},"算至阁楼顶",{"key":22,"text":416,"correct":20},"算至阁楼地面",{"key":24,"text":418,"correct":25},"算至山尖墙的1\u002F2高度处",{"key":27,"text":420,"correct":20},"算至阁楼高度的1\u002F2处",{"id":422,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":423,"answer":19,"analysis":16},921192,[424,425,426,427],{"key":19,"text":16,"correct":25},{"key":22,"text":16,"correct":20},{"key":24,"text":16,"correct":20},{"key":27,"text":16,"correct":20},{"id":429,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":430,"answer":19,"analysis":16},921193,[431,433,435,437],{"key":19,"text":432,"correct":25},"杆a大于杆b",{"key":22,"text":434,"correct":20},"杆a小于杆b",{"key":24,"text":436,"correct":20},"杆a等于杆b",{"key":27,"text":438,"correct":20},"无法判断",{"id":440,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":441,"answer":19,"analysis":16},921194,[442,443,444,445],{"key":19,"text":16,"correct":25},{"key":22,"text":16,"correct":20},{"key":24,"text":16,"correct":20},{"key":27,"text":16,"correct":20},{"id":447,"libraryId":5,"type":8,"typeLabel":15,"stem":448,"options":449,"answer":24,"analysis":16},921195,"简支于柱顶的静定钢桁架，其材质为3号钢(Q235)。如仅将其下弦杆改为16Mn(Q345)钢，在同样的节点荷载作用下，下弦杆的内力( )。",[450,452,454,456],{"key":19,"text":451,"correct":20},"增大",{"key":22,"text":453,"correct":20},"减小",{"key":24,"text":455,"correct":25},"不变",{"key":27,"text":457,"correct":20},"不确定",{"id":459,"libraryId":5,"type":8,"typeLabel":15,"stem":460,"options":461,"answer":27,"analysis":16},921196,"轴心受压柱的最常见配筋形式为纵筋及横向箍筋，这是因为( )。Ⅰ.纵筋能帮助混凝土承受压力，以减少构件的截面尺寸；Ⅱ.纵筋能防止构件突然脆裂破坏及增强构件的延性；Ⅲ.纵筋能减小混凝土的徐变变形；Ⅳ.箍筋能与纵筋形成骨架，防止纵筋受力外凸",[462,463,465,467],{"key":19,"text":380,"correct":20},{"key":22,"text":464,"correct":20},"Ⅱ、Ⅲ、Ⅳ",{"key":24,"text":466,"correct":20},"Ⅰ、Ⅲ、Ⅳ",{"key":27,"text":384,"correct":25},{"id":469,"libraryId":5,"type":8,"typeLabel":15,"stem":470,"options":471,"answer":19,"analysis":16},921197,"对于砂土地基上的一般建筑，其在施工期间完成的沉降量为( )。",[472,474,476,478],{"key":19,"text":473,"correct":25},"已基本完成其最终沉降量",{"key":22,"text":475,"correct":20},"完成其最终沉降量的50%～80%",{"key":24,"text":477,"correct":20},"已完成其最终沉降量的20%～50%",{"key":27,"text":479,"correct":20},"只完成其最终沉降量的20%以下",{"id":481,"libraryId":5,"type":8,"typeLabel":15,"stem":482,"options":483,"answer":27,"analysis":16},921198,"房屋支撑系统的作用是提高结构的整体刚度、发挥结构的空间作用和( )等。因此，支撑系统的合理布置和设计，对房屋的工程质量和安全、适用有极其重要的意义。",[484,486,488,490],{"key":19,"text":485,"correct":20},"保证结构的几何稳定性及受压构件的侧向稳定",{"key":22,"text":487,"correct":20},"防止构件在动力荷载作用下产生较大的振动",{"key":24,"text":489,"correct":20},"承担和传递房屋所受水平荷载以及保证安装时的稳定和安全",{"key":27,"text":491,"correct":25},"以上三者",{"id":493,"libraryId":5,"type":8,"typeLabel":15,"stem":494,"options":495,"answer":24,"analysis":16},921199,"关于设计近震与设计远震，下列说法中正确的是( )。",[496,498,500,502],{"key":19,"text":497,"correct":20},"近震指距震中距离较近的地震",{"key":22,"text":499,"correct":20},"远震的地震影响比近震要小",{"key":24,"text":501,"correct":25},"远震是某地区所遭受的烈度比震中低二度或二度以上的地震",{"key":27,"text":503,"correct":20},"震级较大、震中距较远的地震，对周期较短的刚性结构的破坏，比同样烈度震级较小，震中距较近的破坏要重",{"id":505,"libraryId":5,"type":8,"typeLabel":15,"stem":506,"options":507,"answer":24,"analysis":16},921200,"在抗震设计中，支承在结构上的( )不属于建筑附属机电设备的范围。",[508,510,512,514],{"key":19,"text":509,"correct":20},"宾馆中的电梯",{"key":22,"text":511,"correct":20},"通讯设备",{"key":24,"text":513,"correct":25},"厂房中生产设备的电气系统",{"key":27,"text":515,"correct":20},"空调系统",{"id":517,"libraryId":5,"type":8,"typeLabel":15,"stem":518,"options":519,"answer":22,"analysis":16},921201,"钢结构房屋的防震缝宽度，至少应不小于相应钢筋混凝土结构房屋的( )倍。",[520,522,523,525],{"key":19,"text":521,"correct":20},"1.0",{"key":22,"text":314,"correct":25},{"key":24,"text":524,"correct":20},"2.0",{"key":27,"text":312,"correct":20},{"id":527,"libraryId":5,"type":8,"typeLabel":15,"stem":528,"options":529,"answer":22,"analysis":16},921202,"为防止木结构受潮，构造上应采取一系列措施，下列( )说法是错误的。",[530,532,534,536],{"key":19,"text":531,"correct":20},"处于房屋隐蔽部分的木结构，应设通风孔洞",{"key":22,"text":533,"correct":25},"将桁架支座节点或木构件封闭在墙内",{"key":24,"text":535,"correct":20},"在桁架和大梁的支座下设置防潮层",{"key":27,"text":537,"correct":20},"在木柱下设置柱墩",{"id":539,"libraryId":5,"type":8,"typeLabel":15,"stem":540,"options":541,"answer":19,"analysis":16},921203,"某体育场设计中采用了国产钢材Q460 E，其中460是指( )。",[542,544,546,548],{"key":19,"text":543,"correct":25},"抗拉强度标准值",{"key":22,"text":545,"correct":20},"抗拉强度设计值",{"key":24,"text":547,"correct":20},"抗压强度标准值",{"key":27,"text":549,"correct":20},"抗压强度设计值",{"id":551,"libraryId":5,"type":8,"typeLabel":15,"stem":552,"options":553,"answer":24,"analysis":16},921204,"在地震区，配筋砌块砌体剪力墙的厚度，在任何情况下都不应小于( )mm。",[554,556,558,560],{"key":19,"text":555,"correct":20},"120",{"key":22,"text":557,"correct":20},"180",{"key":24,"text":559,"correct":25},"190",{"key":27,"text":561,"correct":20},"240",[563,566,569,572,576,578],{"id":8,"name":564,"category":7,"favorite":565},"领导干部任职前廉政法规知识测试题",92,{"id":567,"name":568,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":570,"name":571,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":573,"name":574,"category":7,"favorite":575},534,"BIM工程师",0,{"id":577,"name":574,"category":7,"favorite":575},535,{"id":579,"name":580,"category":7,"favorite":575},536,"安全人A证"]