[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":549},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,27,50,2979,[13,33,44,56,68,80,92,99,111,122,133,145,156,163,173,185,197,205,217,228,240,249,261,268,279,290,301,308,320,332,344,356,368,380,392,403,410,419,426,436,448,458,470,481,491,503,515,527,534,542],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":26,"analysis":32},920555,"单选题","风荷载对高层建筑是一种主要的荷载，下列建筑形状中，( )的风荷载体型系数最小。",[18,22,25,29],{"key":19,"text":20,"correct":21},"A","正多边形",false,{"key":23,"text":24,"correct":21},"B","矩形",{"key":26,"text":27,"correct":28},"C","圆形",true,{"key":30,"text":31,"correct":21},"D","Y形","",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":35,"answer":19,"analysis":32},920556,[36,38,40,42],{"key":19,"text":37,"correct":28},"刚架各部分都不产生内力",{"key":23,"text":39,"correct":21},"仅GFE部分产生内力",{"key":26,"text":41,"correct":21},"仅AEDCB部分产生内力",{"key":30,"text":43,"correct":21},"刚架各部分都产生内力",{"id":45,"libraryId":5,"type":8,"typeLabel":15,"stem":46,"options":47,"answer":26,"analysis":32},920557,"下列关于钢筋混凝土结构构件应符合的力学要求中，( )错误。",[48,50,52,54],{"key":19,"text":49,"correct":21},"弯曲破坏先于剪切破坏",{"key":23,"text":51,"correct":21},"钢筋屈服先于混凝土压溃",{"key":26,"text":53,"correct":28},"钢筋的锚圊粘结破坏先于构件破坏",{"key":30,"text":55,"correct":21},"应进行承载能力极限状态和正常使用极限状态设计",{"id":57,"libraryId":5,"type":8,"typeLabel":15,"stem":58,"options":59,"answer":19,"analysis":32},920558,"根据《混凝土结构设计规范》，住宅建筑现浇单向简支楼板的最小厚度，不应小于下列哪一个数值？( )",[60,62,64,66],{"key":19,"text":61,"correct":28},"60mm",{"key":23,"text":63,"correct":21},"80mm",{"key":26,"text":65,"correct":21},"100mm",{"key":30,"text":67,"correct":21},"120mm",{"id":69,"libraryId":5,"type":8,"typeLabel":15,"stem":70,"options":71,"answer":23,"analysis":32},920559,"在划分现浇钢筋混凝土结构的抗震等级时，应考虑：Ⅰ.设防烈度；Ⅱ.场地类别；Ⅲ.结构类型；ⅠV，房屋高度；V.建筑物的重要性类别。下列( )是正确的。",[72,74,76,78],{"key":19,"text":73,"correct":21},"Ⅰ、Ⅱ、Ⅲ",{"key":23,"text":75,"correct":28},"Ⅰ、Ⅲ、Ⅳ",{"key":26,"text":77,"correct":21},"Ⅰ、Ⅲ、V",{"key":30,"text":79,"correct":21},"Ⅲ、Ⅳ、V",{"id":81,"libraryId":5,"type":8,"typeLabel":15,"stem":82,"options":83,"answer":23,"analysis":32},920560,"用未经焙烧的土坯建造的房屋，其最大适宜高度为( )。",[84,86,88,90],{"key":19,"text":85,"correct":21},"在设防烈度为6～7度时，建两层",{"key":23,"text":87,"correct":28},"在设防烈度为6～8度时，建单层",{"key":26,"text":89,"correct":21},"在设防烈度为6～8度时，建两层",{"key":30,"text":91,"correct":21},"只能在设防烈度为6度以下时建单层",{"id":93,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":94,"answer":30,"analysis":32},920561,[95,96,97,98],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":28},{"id":100,"libraryId":5,"type":8,"typeLabel":15,"stem":101,"options":102,"answer":23,"analysis":32},920562,"某建筑物，其抗震设防烈度为7度，根据《建筑抗震设计规范》，“小震不坏”的设防目标是指下列( )。",[103,105,107,109],{"key":19,"text":104,"correct":21},"当遭遇低于7度的多遇地震影响时，经修理仍可继续使用",{"key":23,"text":106,"correct":28},"当遭遇低于7度的多遇地震影响时，一般不受损坏或不需修理仍可继续使用",{"key":26,"text":108,"correct":21},"当遭受7度的地震影响时，不受损坏或不需修理仍可继续使用",{"key":30,"text":110,"correct":21},"当遭遇低于7度的多遇地震影响时可能损坏，经一般修理仍可继续使用",{"id":112,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":113,"answer":26,"analysis":32},920563,[114,116,118,120],{"key":19,"text":115,"correct":21},"增大",{"key":23,"text":117,"correct":21},"减小",{"key":26,"text":119,"correct":28},"不变",{"key":30,"text":121,"correct":21},"不能确定",{"id":123,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":124,"answer":30,"analysis":32},920564,[125,127,129,131],{"key":19,"text":126,"correct":21},"10kN",{"key":23,"text":128,"correct":21},"15kN",{"key":26,"text":130,"correct":21},"20kN",{"key":30,"text":132,"correct":28},"30kN",{"id":134,"libraryId":5,"type":8,"typeLabel":15,"stem":135,"options":136,"answer":23,"analysis":32},920565,"关于抗震墙的竖向和横向分布钢筋，下列( )要求是错误的。",[137,139,141,143],{"key":19,"text":138,"correct":21},"配筋率均不应小于0.25%",{"key":23,"text":140,"correct":28},"钢筋直径不宜小于8mm",{"key":26,"text":142,"correct":21},"间距不宜大于300mm",{"key":30,"text":144,"correct":21},"分布钢筋应双排布置，双排分布钢筋间应设置拉筋",{"id":146,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":147,"answer":30,"analysis":32},920566,[148,150,152,154],{"key":19,"text":149,"correct":21},"四边简支",{"key":23,"text":151,"correct":21},"三边简支，一边自由",{"key":26,"text":153,"correct":21},"三边嵌固，一边简支",{"key":30,"text":155,"correct":28},"三边嵌固，一边自由",{"id":157,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":158,"answer":19,"analysis":32},920567,[159,160,161,162],{"key":19,"text":32,"correct":28},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":21},{"id":164,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":165,"answer":26,"analysis":32},920568,[166,168,170,171],{"key":19,"text":167,"correct":21},"Ⅰ、Ⅱ",{"key":23,"text":169,"correct":21},"Ⅰ、Ⅲ",{"key":26,"text":75,"correct":28},{"key":30,"text":172,"correct":21},"Ⅱ、Ⅵ",{"id":174,"libraryId":5,"type":8,"typeLabel":15,"stem":175,"options":176,"answer":23,"analysis":32},920569,"淤泥质土属于( )。",[177,179,181,183],{"key":19,"text":178,"correct":21},"砂土",{"key":23,"text":180,"correct":28},"粉土或黏性土",{"key":26,"text":182,"correct":21},"粉砂",{"key":30,"text":184,"correct":21},"细砂",{"id":186,"libraryId":5,"type":8,"typeLabel":15,"stem":187,"options":188,"answer":23,"analysis":32},920570,"设防烈度为7度时，五层砖砌体房屋的构造柱箍筋间距不宜大于( )mm。",[189,191,193,195],{"key":19,"text":190,"correct":21},"200",{"key":23,"text":192,"correct":28},"250",{"key":26,"text":194,"correct":21},"300",{"key":30,"text":196,"correct":21},"350",{"id":198,"libraryId":5,"type":8,"typeLabel":15,"stem":199,"options":200,"answer":23,"analysis":32},920571,"图示哪一种结构可简化为桁架体系？( )",[201,202,203,204],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":28},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":21},{"id":206,"libraryId":5,"type":8,"typeLabel":15,"stem":207,"options":208,"answer":23,"analysis":32},920572,"杆系结构中的主要木构件，当有对称削弱时，其净截面面积不应小于毛截面面积的( )。",[209,211,213,215],{"key":19,"text":210,"correct":21},"40%",{"key":23,"text":212,"correct":28},"50%",{"key":26,"text":214,"correct":21},"60%",{"key":30,"text":216,"correct":21},"65%",{"id":218,"libraryId":5,"type":8,"typeLabel":15,"stem":219,"options":220,"answer":19,"analysis":32},920573,"光面钢筋与混凝土之间的黏结锚固力的来源有( )。Ⅰ.胶结力；Ⅱ.摩擦力；Ⅲ.机械咬合力；Ⅳ，锚固力",[221,222,224,226],{"key":19,"text":73,"correct":28},{"key":23,"text":223,"correct":21},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"key":26,"text":225,"correct":21},"Ⅱ、Ⅲ、Ⅳ",{"key":30,"text":227,"correct":21},"Ⅱ、Ⅳ",{"id":229,"libraryId":5,"type":8,"typeLabel":15,"stem":230,"options":231,"answer":19,"analysis":32},920574,"地震区的疾病预防与控制中心建筑中，属于甲类建筑的是( )。",[232,234,236,238],{"key":19,"text":233,"correct":28},"承担研究高危险传染病毒任务的建筑",{"key":23,"text":235,"correct":21},"县疾病预防与控制中心主要建筑",{"key":26,"text":237,"correct":21},"县级市疾病预防与控制中心主要建筑",{"key":30,"text":239,"correct":21},"省疾病预防与控制中心主要建筑",{"id":241,"libraryId":5,"type":8,"typeLabel":15,"stem":242,"options":243,"answer":30,"analysis":32},920575,"关于非结构构件抗震设计要求的叙述，以下( )正确且全面。Ⅰ.附着于楼、屋面结构上的非结构构件，应与主体结构有可靠的连接或锚固；Ⅱ.围护墙和隔墙应考虑对结构抗震的不利影响；Ⅲ.幕墙、装饰贴面与主体结构应有可靠的连接；Ⅳ，安装在建筑上的附属机械、电气设备系统的支座和连接应符合地震时使用功能的要求",[244,245,246,248],{"key":19,"text":73,"correct":21},{"key":23,"text":225,"correct":21},{"key":26,"text":247,"correct":21},"Ⅰ、Ⅱ、Ⅳ",{"key":30,"text":223,"correct":28},{"id":250,"libraryId":5,"type":8,"typeLabel":15,"stem":251,"options":252,"answer":23,"analysis":32},920576,"《建筑结构可靠度设计统一标准》(GB50068-2001)把建筑物的安全等级划分为( )个等级。",[253,255,257,259],{"key":19,"text":254,"correct":21},"2",{"key":23,"text":256,"correct":28},"3",{"key":26,"text":258,"correct":21},"4",{"key":30,"text":260,"correct":21},"5",{"id":262,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":263,"answer":26,"analysis":32},920577,[264,265,266,267],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":28},{"key":30,"text":32,"correct":21},{"id":269,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":270,"answer":19,"analysis":32},920578,[271,273,275,277],{"key":19,"text":272,"correct":28},"无多余约束的几何不变体系",{"key":23,"text":274,"correct":21},"有多余约束的几何不变体系",{"key":26,"text":276,"correct":21},"常变体系",{"key":30,"text":278,"correct":21},"瞬变体系",{"id":280,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":281,"answer":26,"analysis":32},920579,[282,284,286,288],{"key":19,"text":283,"correct":21},"1次",{"key":23,"text":285,"correct":21},"2次",{"key":26,"text":287,"correct":28},"3次",{"key":30,"text":289,"correct":21},"4次",{"id":291,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":292,"answer":26,"analysis":32},920580,[293,295,297,299],{"key":19,"text":294,"correct":21},"几何不变",{"key":23,"text":296,"correct":21},"几何可变",{"key":26,"text":298,"correct":28},"瞬变",{"key":30,"text":300,"correct":21},"超静定结构",{"id":302,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":303,"answer":30,"analysis":32},920581,[304,305,306,307],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":28},{"id":309,"libraryId":5,"type":8,"typeLabel":15,"stem":310,"options":311,"answer":19,"analysis":32},920582,"钢筋混凝土主梁支承在砖柱或砖墙上时，其支座应视为( )支座。",[312,314,316,318],{"key":19,"text":313,"correct":28},"铰接",{"key":23,"text":315,"correct":21},"间接",{"key":26,"text":317,"correct":21},"滚动",{"key":30,"text":319,"correct":21},"弹性",{"id":321,"libraryId":5,"type":8,"typeLabel":15,"stem":322,"options":323,"answer":19,"analysis":32},920583,"在普通碳素钢的化学成分中，碳含量增加，则钢材的( )。",[324,326,328,330],{"key":19,"text":325,"correct":28},"强度提高，塑性、韧性降低",{"key":23,"text":327,"correct":21},"强度提高，塑性、韧性提高",{"key":26,"text":329,"correct":21},"强度降低，塑性、韧性降低",{"key":30,"text":331,"correct":21},"强度降低，塑性、韧性提高",{"id":333,"libraryId":5,"type":8,"typeLabel":15,"stem":334,"options":335,"answer":30,"analysis":32},920584,"下列对钢管混凝土柱中钢管作用的描述中不正确的是( )。",[336,338,340,342],{"key":19,"text":337,"correct":21},"钢管对管中混凝土起约束作用",{"key":23,"text":339,"correct":21},"加设钢管可提高柱子的抗压承载能力",{"key":26,"text":341,"correct":21},"加设钢管可提高柱子的延性",{"key":30,"text":343,"correct":28},"加设钢管可提高柱子的长细比",{"id":345,"libraryId":5,"type":8,"typeLabel":15,"stem":346,"options":347,"answer":23,"analysis":32},920585,"在冻土地基上不采暖房屋的条形基础基底平均压力为170kPa，设计冻深为1.45m，当土的冻胀性类别为强冻胀土时，其基础的最小埋深应为( )。",[348,350,352,354],{"key":19,"text":349,"correct":21},"0.51m",{"key":23,"text":351,"correct":28},"0.61m",{"key":26,"text":353,"correct":21},"0.71m",{"key":30,"text":355,"correct":21},"0.91m",{"id":357,"libraryId":5,"type":8,"typeLabel":15,"stem":358,"options":359,"answer":26,"analysis":32},920586,"钢筋混凝土梁如出现裂缝，下列哪种说法是正确的？( )",[360,362,364,366],{"key":19,"text":361,"correct":21},"不允许",{"key":23,"text":363,"correct":21},"允许，但应满足构件变形的要求",{"key":26,"text":365,"correct":28},"允许，但应满足裂缝宽度的要求",{"key":30,"text":367,"correct":21},"允许，但应满足裂缝开展深度的要求",{"id":369,"libraryId":5,"type":8,"typeLabel":15,"stem":370,"options":371,"answer":19,"analysis":32},920587,"在下列荷载中，( )为活荷载。",[372,374,376,378],{"key":19,"text":373,"correct":28},"风荷载",{"key":23,"text":375,"correct":21},"土压力",{"key":26,"text":377,"correct":21},"结构自重",{"key":30,"text":379,"correct":21},"结构的面层作法",{"id":381,"libraryId":5,"type":8,"typeLabel":15,"stem":382,"options":383,"answer":30,"analysis":32},920588,"关于软弱地基，下列( )说法是不正确的。",[384,386,388,390],{"key":19,"text":385,"correct":21},"软弱地基系指主要由淤泥、淤泥质土、充填土、杂质土或其他高压缩性土层构成的地基",{"key":23,"text":387,"correct":21},"施工时，应注意对淤泥和淤泥质土基槽底面的保护，减少扰动",{"key":26,"text":389,"correct":21},"荷载差异较大的建筑物，宜先建重、高部分，后建轻、低部分",{"key":30,"text":391,"correct":28},"软弱土层必须经过处理后方可作为持力层",{"id":393,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":394,"answer":19,"analysis":32},920589,[395,397,399,401],{"key":19,"text":396,"correct":28},"温度应力由结构中间向两端逐渐增大",{"key":23,"text":398,"correct":21},"温度应力由结构中间向两端逐渐减小",{"key":26,"text":400,"correct":21},"梁、柱的温度应力分别相等",{"key":30,"text":402,"correct":21},"结构不产生温度应力",{"id":404,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":405,"answer":30,"analysis":32},920590,[406,407,408,409],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":28},{"id":411,"libraryId":5,"type":8,"typeLabel":15,"stem":412,"options":413,"answer":30,"analysis":32},920591,"钢屋架节点板厚度一般根据所连接的杆件内力的大小确定，但不得小于( )mm。",[414,415,416,417],{"key":19,"text":254,"correct":21},{"key":23,"text":256,"correct":21},{"key":26,"text":258,"correct":21},{"key":30,"text":418,"correct":28},"6",{"id":420,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":421,"answer":26,"analysis":32},920592,[422,423,424,425],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":28},{"key":30,"text":32,"correct":21},{"id":427,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":428,"answer":26,"analysis":32},920593,[429,431,432,434],{"key":19,"text":430,"correct":21},"4.5",{"key":23,"text":418,"correct":21},{"key":26,"text":433,"correct":28},"7.5",{"key":30,"text":435,"correct":21},"9",{"id":437,"libraryId":5,"type":8,"typeLabel":15,"stem":438,"options":439,"answer":30,"analysis":32},920594,"我国抗震设防的水准是( )。",[440,442,444,446],{"key":19,"text":441,"correct":21},"不裂不倒",{"key":23,"text":443,"correct":21},"裂而不倒",{"key":26,"text":445,"correct":21},"小震、中震皆可修",{"key":30,"text":447,"correct":28},"小震不坏，中震可修，大震不倒",{"id":449,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":450,"answer":26,"analysis":32},920595,[451,453,455,457],{"key":19,"text":452,"correct":21},"顺时针转动",{"key":23,"text":454,"correct":21},"逆时针转动",{"key":26,"text":456,"correct":28},"无转动",{"key":30,"text":121,"correct":21},{"id":459,"libraryId":5,"type":8,"typeLabel":15,"stem":460,"options":461,"answer":23,"analysis":32},920596,"抗震设计时，下列全部消除地基液化的措施中不正确的是( )。",[462,464,466,468],{"key":19,"text":463,"correct":21},"采用桩基，桩端深入液化土层以下稳定土层中必要的深度",{"key":23,"text":465,"correct":28},"采用筏板基础",{"key":26,"text":467,"correct":21},"采用加密法，处理至液化深度下界",{"key":30,"text":469,"correct":21},"用非液化土替换全部液化土层",{"id":471,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":472,"answer":23,"analysis":32},920597,[473,475,477,479],{"key":19,"text":474,"correct":21},"Ⅰ点",{"key":23,"text":476,"correct":28},"Ⅱ点",{"key":26,"text":478,"correct":21},"截面四个角顶点",{"key":30,"text":480,"correct":21},"沿截面外周圈均匀相等",{"id":482,"libraryId":5,"type":8,"typeLabel":15,"stem":483,"options":484,"answer":30,"analysis":32},920598,"决定多、高层钢筋混凝土房屋防震缝宽度的因素有( )。Ⅰ.建筑的重要性；Ⅱ，建筑物的高度；Ⅲ.场地类别；Ⅳ.结构类型；V.设防烈度",[485,486,487,489],{"key":19,"text":77,"correct":21},{"key":23,"text":225,"correct":21},{"key":26,"text":488,"correct":21},"Ⅱ、Ⅲ、V",{"key":30,"text":490,"correct":28},"Ⅱ、Ⅳ、V",{"id":492,"libraryId":5,"type":8,"typeLabel":15,"stem":493,"options":494,"answer":23,"analysis":32},920599,"为了防止或减轻房屋在正常使用条件下，由温差和砌体干缩引起的墙体竖向裂缝，对于装配整体式钢筋混凝土结构有保温层屋盖的砌体房屋伸缩缝的最大间距取( )m。",[495,497,499,501],{"key":19,"text":496,"correct":21},"40",{"key":23,"text":498,"correct":28},"50",{"key":26,"text":500,"correct":21},"60",{"key":30,"text":502,"correct":21},"70",{"id":504,"libraryId":5,"type":8,"typeLabel":15,"stem":505,"options":506,"answer":19,"analysis":32},920600,"下列关于单层砖柱厂房结构要求的叙述何项不正确？( )",[507,509,511,513],{"key":19,"text":508,"correct":28},"厂房屋盖不宜采用轻型屋盖",{"key":23,"text":510,"correct":21},"厂房两端均应设置砖称重山墙",{"key":26,"text":512,"correct":21},"8度抗震设防时不应采用无筋砖柱",{"key":30,"text":514,"correct":21},"厂房天窗不应通至厂房单元的端开间",{"id":516,"libraryId":5,"type":8,"typeLabel":15,"stem":517,"options":518,"answer":23,"analysis":32},920601,"( )设防条件下的高层建筑应考虑竖向地震作用。",[519,521,523,525],{"key":19,"text":520,"correct":21},"8度",{"key":23,"text":522,"correct":28},"9度",{"key":26,"text":524,"correct":21},"均应考虑",{"key":30,"text":526,"correct":21},"7度",{"id":528,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":529,"answer":23,"analysis":32},920602,[530,531,532,533],{"key":19,"text":19,"correct":21},{"key":23,"text":23,"correct":28},{"key":26,"text":26,"correct":21},{"key":30,"text":30,"correct":21},{"id":535,"libraryId":5,"type":8,"typeLabel":15,"stem":536,"options":537,"answer":30,"analysis":32},920603,"影响砌体抗压强度的因素有( )。Ⅰ.块体的强度等级；Ⅱ.砂浆的强度等级；Ⅲ.砂浆品种；Ⅳ.砌筑质量",[538,539,540,541],{"key":19,"text":167,"correct":21},{"key":23,"text":225,"correct":21},{"key":26,"text":73,"correct":21},{"key":30,"text":223,"correct":28},{"id":543,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":544,"answer":19,"analysis":32},920604,[545,546,547,548],{"key":19,"text":32,"correct":28},{"key":23,"text":32,"correct":21},{"key":26,"text":32,"correct":21},{"key":30,"text":32,"correct":21},[550,553,556,559,563,565],{"id":8,"name":551,"category":7,"favorite":552},"领导干部任职前廉政法规知识测试题",92,{"id":554,"name":555,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":557,"name":558,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":560,"name":561,"category":7,"favorite":562},534,"BIM工程师",0,{"id":564,"name":561,"category":7,"favorite":562},535,{"id":566,"name":567,"category":7,"favorite":562},536,"安全人A证"]