[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-595-23":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":548},{"id":5,"name":6,"category":7,"favorite":8},595,"建筑结构与设备","建筑工程",1,23,50,2979,[13,33,45,57,69,81,92,100,111,119,131,143,155,167,179,190,202,214,225,234,244,256,263,270,282,294,306,313,320,327,335,343,352,359,371,383,394,406,418,425,434,446,458,470,482,493,505,516,528,540],{"id":14,"libraryId":5,"type":8,"typeLabel":15,"stem":16,"options":17,"answer":19,"analysis":32},920355,"单选题","深层搅拌法，主要适用于处理( )。",[18,22,26,29],{"key":19,"text":20,"correct":21},"A","淤泥",true,{"key":23,"text":24,"correct":25},"B","黏性土",false,{"key":27,"text":28,"correct":25},"C","砂土",{"key":30,"text":31,"correct":25},"D","杂填土","",{"id":34,"libraryId":5,"type":8,"typeLabel":15,"stem":35,"options":36,"answer":23,"analysis":32},920356,"下列关于钢筋混凝土圈梁的构造要求中，正确的是( )。",[37,39,41,43],{"key":19,"text":38,"correct":25},"高度不应小于100mm，纵向钢筋不应少于4φ6",{"key":23,"text":40,"correct":21},"高度不应小于120mm，纵向钢筋不应少于4φ10",{"key":27,"text":42,"correct":25},"高度不应小于150mm，纵向钢筋不应少于4φ8",{"key":30,"text":44,"correct":25},"高度不应小于180mm，纵向钢筋不应少于4φ8",{"id":46,"libraryId":5,"type":8,"typeLabel":15,"stem":47,"options":48,"answer":30,"analysis":32},920357,"引起预应力损失的原因有( )。Ⅰ.锚具变形引起；Ⅱ.预应力钢筋与孔道壁之间的摩擦引起；Ⅲ.蒸汽养护时产生；Ⅳ，钢筋应力松弛产生；V.混凝土收缩和徐变引起；Ⅵ，环形构件由于混凝土局部挤压引起",[49,51,53,55],{"key":19,"text":50,"correct":25},"Ⅰ、Ⅲ、V",{"key":23,"text":52,"correct":25},"Ⅰ、Ⅱ、Ⅳ、V",{"key":27,"text":54,"correct":25},"Ⅰ、Ⅱ、Ⅲ、V",{"key":30,"text":56,"correct":21},"Ⅰ、Ⅱ、Ⅲ、Ⅳ、V、Ⅵ",{"id":58,"libraryId":5,"type":8,"typeLabel":15,"stem":59,"options":60,"answer":23,"analysis":32},920358,"关于钢筋混凝土剪力墙的布置，下列说法中错误的是( )。",[61,63,65,67],{"key":19,"text":62,"correct":25},"剪力墙应双向或多向布置，宜拉通对直",{"key":23,"text":64,"correct":21},"较长的剪力墙可开洞后设连梁，连梁应有足够的刚度，不得仅用楼板连接",{"key":27,"text":66,"correct":25},"剪力墙的门窗洞口宜上下对齐，成列布置",{"key":30,"text":68,"correct":25},"墙肢截面高度与厚度之比不宜过小",{"id":70,"libraryId":5,"type":8,"typeLabel":15,"stem":71,"options":72,"answer":27,"analysis":32},920359,"钢筋混凝土承台之间的联系梁的高度与承台中心距的比值，下列( )数值范围是恰当的。",[73,75,77,79],{"key":19,"text":74,"correct":25},"1\u002F8～1\u002F6",{"key":23,"text":76,"correct":25},"1\u002F10～1\u002F8",{"key":27,"text":78,"correct":21},"1\u002F15～1\u002F10",{"key":30,"text":80,"correct":25},"1\u002F18.1\u002F15",{"id":82,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":83,"answer":27,"analysis":32},920360,[84,86,88,90],{"key":19,"text":85,"correct":25},"E点右截面剪力为P\u002F2",{"key":23,"text":87,"correct":25},"D点左截面剪力为P",{"key":27,"text":89,"correct":21},"C点弯矩为0",{"key":30,"text":91,"correct":25},"D点弯矩为0",{"id":93,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":94,"answer":23,"analysis":32},920361,[95,96,97,98],{"key":19,"text":32,"correct":25},{"key":23,"text":32,"correct":21},{"key":27,"text":32,"correct":25},{"key":30,"text":99,"correct":25},"不确定",{"id":101,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":102,"answer":23,"analysis":32},920362,[103,105,107,109],{"key":19,"text":104,"correct":25},"图A",{"key":23,"text":106,"correct":21},"图B",{"key":27,"text":108,"correct":25},"图C",{"key":30,"text":110,"correct":25},"图D",{"id":112,"libraryId":5,"type":8,"typeLabel":15,"stem":113,"options":114,"answer":19,"analysis":32},920363,"当框架同时有温度升高时，图示下列结构中哪一种不会产生内力？( )",[115,116,117,118],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":25},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":25},{"id":120,"libraryId":5,"type":8,"typeLabel":15,"stem":121,"options":122,"answer":30,"analysis":32},920364,"均布荷载(方向向下)作用下的简支梁，其截面内的上部混凝土承受( )。",[123,125,127,129],{"key":19,"text":124,"correct":25},"拉应力",{"key":23,"text":126,"correct":25},"压应力",{"key":27,"text":128,"correct":25},"剪应力",{"key":30,"text":130,"correct":21},"压应力和剪应力",{"id":132,"libraryId":5,"type":8,"typeLabel":15,"stem":133,"options":134,"answer":19,"analysis":32},920365,"框架一剪力墙结构在8度抗震设计中，剪力墙的间距不宜超过下列( )中的较小值(B-楼面宽度)。 A.3 B，40m B.6 B，50m",[135,137,139,141],{"key":19,"text":136,"correct":21},"6",{"key":23,"text":138,"correct":25},"60m",{"key":27,"text":140,"correct":25},"5",{"key":30,"text":142,"correct":25},"70m",{"id":144,"libraryId":5,"type":8,"typeLabel":15,"stem":145,"options":146,"answer":27,"analysis":32},920366,"对钢筋混凝土屋面梁出现裂缝的限制是( )。",[147,149,151,153],{"key":19,"text":148,"correct":25},"不允许梁面有裂缝",{"key":23,"text":150,"correct":25},"不允许梁底有裂缝",{"key":27,"text":152,"correct":21},"允许出现裂缝，但应限制裂缝宽度",{"key":30,"text":154,"correct":25},"允许出现裂缝，但应限制裂缝深度",{"id":156,"libraryId":5,"type":8,"typeLabel":15,"stem":157,"options":158,"answer":27,"analysis":32},920367,"为了防止砌体房屋因温差和砌体干缩引起墙体产生竖向裂缝，应设置伸缩缝。下列情况中允许温度伸缩缝间距最大的是( )。",[159,161,163,165],{"key":19,"text":160,"correct":25},"现浇钢筋混凝土楼(屋)盖，有保温",{"key":23,"text":162,"correct":25},"现浇钢筋混凝土楼(屋)盖，无保温层",{"key":27,"text":164,"correct":21},"装配式钢筋混凝土楼(屋)盖，有保温层",{"key":30,"text":166,"correct":25},"装配式钢筋混凝土楼(屋)盖，无保温层",{"id":168,"libraryId":5,"type":8,"typeLabel":15,"stem":169,"options":170,"answer":23,"analysis":32},920368,"我国规范中，对焊接结构规定了严格的含碳量标淮，即要求含碳量应≤( )。",[171,173,175,177],{"key":19,"text":172,"correct":25},"0.02%",{"key":23,"text":174,"correct":21},"0.22%",{"key":27,"text":176,"correct":25},"2%",{"key":30,"text":178,"correct":25},"2.2%",{"id":180,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":181,"answer":27,"analysis":32},920369,[182,184,186,188],{"key":19,"text":183,"correct":25},"217.1",{"key":23,"text":185,"correct":25},"241.2",{"key":27,"text":187,"correct":21},"289.4",{"key":30,"text":189,"correct":25},"418.1",{"id":191,"libraryId":5,"type":8,"typeLabel":15,"stem":192,"options":193,"answer":19,"analysis":32},920370,"下述关于后张有粘结预应力混凝土的理解，( )正确。Ⅰ.需要锚具传递预应力Ⅱ，不需要锚具传递预应力Ⅲ.构件制作时必须预留孔道Ⅳ，张拉完毕不需要进行孔道灌浆",[194,196,198,200],{"key":19,"text":195,"correct":21},"Ⅰ、Ⅲ",{"key":23,"text":197,"correct":25},"Ⅰ、Ⅳ",{"key":27,"text":199,"correct":25},"Ⅱ、Ⅲ",{"key":30,"text":201,"correct":25},"Ⅱ、Ⅳ",{"id":203,"libraryId":5,"type":8,"typeLabel":15,"stem":204,"options":205,"answer":23,"analysis":32},920371,"钢筋混凝土叠合式受弯构件与其相应的现浇构件相比，具有以下( )优点。Ⅰ.施工速度快；Ⅱ，节省模板；Ⅲ.具有更好的抗震性能；Ⅳ，减少现浇混凝土量",[206,208,210,212],{"key":19,"text":207,"correct":25},"Ⅰ、Ⅱ、Ⅲ",{"key":23,"text":209,"correct":21},"Ⅰ、Ⅱ、Ⅳ",{"key":27,"text":211,"correct":25},"Ⅱ、Ⅲ、Ⅳ",{"key":30,"text":213,"correct":25},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"id":215,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":216,"answer":30,"analysis":32},920372,[217,219,221,223],{"key":19,"text":218,"correct":25},"5kN·m，左侧受拉",{"key":23,"text":220,"correct":25},"6kN·m，右侧受拉",{"key":27,"text":222,"correct":25},"3kN·m，右侧受拉",{"key":30,"text":224,"correct":21},"3kN·m，左侧受拉",{"id":226,"libraryId":5,"type":8,"typeLabel":15,"stem":227,"options":228,"answer":30,"analysis":32},920373,"预制装配式钢筋混凝土楼盖的优点是( )。Ⅰ.安装速度快，节省模板，造价低；Ⅱ，整体性、抗震性好，一般适用于民用建筑；Ⅲ.结构布置灵活，适应不规则平面；Ⅳ.多采用预应力，节省钢材，减轻结构自重",[229,230,231,233],{"key":19,"text":195,"correct":25},{"key":23,"text":201,"correct":25},{"key":27,"text":232,"correct":25},"Ⅰ、Ⅱ",{"key":30,"text":197,"correct":21},{"id":235,"libraryId":5,"type":8,"typeLabel":15,"stem":236,"options":237,"answer":30,"analysis":32},920374,"高层建筑防震缝的最小宽度，与( )有关。Ⅰ.结构体系；Ⅱ.房屋平面形式；Ⅲ.设防烈度；Ⅳ，房屋高度",[238,239,241,242],{"key":19,"text":232,"correct":25},{"key":23,"text":240,"correct":25},"Ⅲ、Ⅳ",{"key":27,"text":211,"correct":25},{"key":30,"text":243,"correct":21},"Ⅰ、Ⅲ、Ⅳ",{"id":245,"libraryId":5,"type":8,"typeLabel":15,"stem":246,"options":247,"answer":23,"analysis":32},920375,"钢筋混凝土梁当端部受到部分约束但按简支梁计算时，应在支座区上部设置纵向构造钢筋，其截面面积不应小于梁跨中下部纵向受力钢筋计算所需截面面积的( )。",[248,250,252,254],{"key":19,"text":249,"correct":25},"1\u002F3",{"key":23,"text":251,"correct":21},"1\u002F4",{"key":27,"text":253,"correct":25},"1\u002F5",{"key":30,"text":255,"correct":25},"1\u002F10",{"id":257,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":258,"answer":23,"analysis":32},920376,[259,260,261,262],{"key":19,"text":32,"correct":25},{"key":23,"text":32,"correct":21},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":25},{"id":264,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":265,"answer":23,"analysis":32},920377,[266,267,268,269],{"key":19,"text":32,"correct":25},{"key":23,"text":32,"correct":21},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":25},{"id":271,"libraryId":5,"type":8,"typeLabel":15,"stem":272,"options":273,"answer":23,"analysis":32},920378,"控制和减小钢筋混凝土结构构件裂缝宽度的措施，下列( )错误。",[274,276,278,280],{"key":19,"text":275,"correct":25},"采用预应力技术",{"key":23,"text":277,"correct":21},"在相同配筋率下，采用较大直径钢筋",{"key":27,"text":279,"correct":25},"提高配筋率",{"key":30,"text":281,"correct":25},"采用带肋钢筋",{"id":283,"libraryId":5,"type":8,"typeLabel":15,"stem":284,"options":285,"answer":19,"analysis":32},920379,"多层砌体房屋抗震承载力验算是为了防止( )破坏。",[286,288,290,292],{"key":19,"text":287,"correct":21},"剪切破坏",{"key":23,"text":289,"correct":25},"弯曲破坏",{"key":27,"text":291,"correct":25},"压弯破坏",{"key":30,"text":293,"correct":25},"弯剪破坏",{"id":295,"libraryId":5,"type":8,"typeLabel":15,"stem":296,"options":297,"answer":30,"analysis":32},920380,"关于承重木结构用胶，下列哪种说法是错误的？( )",[298,300,302,304],{"key":19,"text":299,"correct":25},"应保证胶合强度不低于木材顺纹抗剪强度",{"key":23,"text":301,"correct":25},"应保证胶合强度不低于木材横纹抗控强度",{"key":27,"text":303,"correct":25},"应保证胶连接的耐水性和耐久性",{"key":30,"text":305,"correct":21},"当有出厂质量证明时，使用前可不再检验其胶黏能力",{"id":307,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":308,"answer":19,"analysis":32},920381,[309,310,311,312],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":25},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":25},{"id":314,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":315,"answer":23,"analysis":32},920382,[316,317,318,319],{"key":19,"text":32,"correct":25},{"key":23,"text":32,"correct":21},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":25},{"id":321,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":322,"answer":27,"analysis":32},920383,[323,324,325,326],{"key":19,"text":32,"correct":25},{"key":23,"text":32,"correct":25},{"key":27,"text":32,"correct":21},{"key":30,"text":32,"correct":25},{"id":328,"libraryId":5,"type":8,"typeLabel":15,"stem":329,"options":330,"answer":27,"analysis":32},920384,"框架抗震设计中应遵循的原则有( )。Ⅰ.强柱弱梁；Ⅱ，强弯弱剪；Ⅲ.强剪弱弯；Ⅳ。强节点、强锚固",[331,332,333,334],{"key":19,"text":195,"correct":25},{"key":23,"text":232,"correct":25},{"key":27,"text":243,"correct":21},{"key":30,"text":209,"correct":25},{"id":336,"libraryId":5,"type":8,"typeLabel":15,"stem":337,"options":338,"answer":23,"analysis":32},920385,"合理配置预应力钢筋，下述主要作用哪些叙述正确？( )Ⅰ.可提高构件的抗裂度Ⅱ.可提高构件的极限承载能力Ⅲ.可减小截面受压区高度，增加构件的转动能力Ⅳ.可适当减小构件截面的高度",[339,340,341,342],{"key":19,"text":232,"correct":25},{"key":23,"text":197,"correct":21},{"key":27,"text":207,"correct":25},{"key":30,"text":213,"correct":25},{"id":344,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":345,"answer":23,"analysis":32},920386,[346,347,348,350],{"key":19,"text":32,"correct":25},{"key":23,"text":32,"correct":21},{"key":27,"text":349,"correct":25},"Ph",{"key":30,"text":351,"correct":25},"2Ph",{"id":353,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":354,"answer":30,"analysis":32},920387,[355,356,357,358],{"key":19,"text":32,"correct":25},{"key":23,"text":32,"correct":25},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":21},{"id":360,"libraryId":5,"type":8,"typeLabel":15,"stem":361,"options":362,"answer":27,"analysis":32},920388,"“小震不坏，中震可修，大震不倒”是抗震设防的标准，所谓小震是指( )。",[363,365,367,369],{"key":19,"text":364,"correct":25},"6度或7度的地震",{"key":23,"text":366,"correct":25},"50年设计基准期内，超越概率大于10%的地震",{"key":27,"text":368,"correct":21},"50年设计基准期内，超越概率为63.3%的地震",{"key":30,"text":370,"correct":25},"6度以下的地震",{"id":372,"libraryId":5,"type":8,"typeLabel":15,"stem":373,"options":374,"answer":27,"analysis":32},920389,"某大城市的三级医院拟建四栋楼房，其中属于乙类建筑的是( )。",[375,377,379,381],{"key":19,"text":376,"correct":25},"30层的剪力墙结构住宅",{"key":23,"text":378,"correct":25},"5层的框架结构办公住宅",{"key":27,"text":380,"correct":21},"8层的框一剪结构医院楼",{"key":30,"text":382,"correct":25},"10层的框一剪结构科研楼",{"id":384,"libraryId":5,"type":8,"typeLabel":15,"stem":385,"options":386,"answer":23,"analysis":32},920390,"当屋面板上部有保温或隔热措施时，全现浇钢筋混凝土框架结构房屋，其伸缩缝的最大间距为下列( )数值。",[387,389,391,393],{"key":19,"text":388,"correct":25},"45m",{"key":23,"text":390,"correct":21},"55m",{"key":27,"text":392,"correct":25},"50m",{"key":30,"text":138,"correct":25},{"id":395,"libraryId":5,"type":8,"typeLabel":15,"stem":396,"options":397,"answer":30,"analysis":32},920391,"关于抗震设防地区多层砌块房屋圈梁设置的下列叙述，( )不正确。",[398,400,402,404],{"key":19,"text":399,"correct":25},"屋盖及每层楼盖处的外墙应设置圈梁",{"key":23,"text":401,"correct":25},"屋盖及每层楼盖处的内纵墙应设置圈梁",{"key":27,"text":403,"correct":25},"内横墙在构造柱对应部位应设置圈梁",{"key":30,"text":405,"correct":21},"屋盖处内横墙的圈梁间距不应大于15m",{"id":407,"libraryId":5,"type":8,"typeLabel":15,"stem":408,"options":409,"answer":27,"analysis":32},920392,"在抗震设计中，下列构件中( )不属于建筑非结构构件的范围。",[410,412,414,416],{"key":19,"text":411,"correct":25},"固定于楼面的大型储物架",{"key":23,"text":413,"correct":25},"幕墙",{"key":27,"text":415,"correct":21},"阳台",{"key":30,"text":417,"correct":25},"公用天线",{"id":419,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":420,"answer":30,"analysis":32},920393,[421,422,423,424],{"key":19,"text":32,"correct":25},{"key":23,"text":32,"correct":25},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":21},{"id":426,"libraryId":5,"type":8,"typeLabel":15,"stem":427,"options":428,"answer":30,"analysis":32},920394,"以下关于钢材规格的叙述，错误的是( )。",[429,431,432,433],{"key":19,"text":430,"correct":25},"热轧钢板-600×10×12000代表钢板宽600mm，厚10mm，长12m",{"key":23,"text":32,"correct":25},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":21},{"id":435,"libraryId":5,"type":8,"typeLabel":15,"stem":436,"options":437,"answer":27,"analysis":32},920395,"根据《建筑抗震设计规范》(GB50011-2001)，抗震设计时，抗震墙结构和框架一抗震墙结构其底部加强部位的高度是指( )。",[438,440,442,444],{"key":19,"text":439,"correct":25},"底部二层",{"key":23,"text":441,"correct":25},"墙段总高度的1\u002F8和底部二层二者的较大值",{"key":27,"text":443,"correct":21},"墙肢总高度的1\u002F8和底部二层二者的较大值，且不大于15m",{"key":30,"text":445,"correct":25},"底部三层，且不大于15m",{"id":447,"libraryId":5,"type":8,"typeLabel":15,"stem":448,"options":449,"answer":27,"analysis":32},920396,"高层建筑采用钢筋混凝土结构时，外筒柱子截面设计成( )为最好。",[450,452,454,456],{"key":19,"text":451,"correct":25},"圆形截面",{"key":23,"text":453,"correct":25},"正方形截面",{"key":27,"text":455,"correct":21},"矩形截面、长边平行外墙放置",{"key":30,"text":457,"correct":25},"矩形截面、短边平行外墙放置",{"id":459,"libraryId":5,"type":8,"typeLabel":15,"stem":460,"options":461,"answer":27,"analysis":32},920397,"下列关于构造柱设置的叙述中不正确的是( )。",[462,464,466,468],{"key":19,"text":463,"correct":25},"楼梯间四角宜设构造柱",{"key":23,"text":465,"correct":25},"外墙四角宜设构造柱",{"key":27,"text":467,"correct":21},"构造柱一定要单独设置基础",{"key":30,"text":469,"correct":25},"大房间外墙交接处应设构造柱",{"id":471,"libraryId":5,"type":8,"typeLabel":15,"stem":472,"options":473,"answer":23,"analysis":32},920398,"当跨度在60m以上，平面为圆形或八角形时，宜采用( )。",[474,476,478,480],{"key":19,"text":475,"correct":25},"正方格网架，斜方格网架",{"key":23,"text":477,"correct":21},"三角格网架，三角锥网架",{"key":27,"text":479,"correct":25},"正四角锥网架，斜四角锥网架",{"key":30,"text":481,"correct":25},"正方格网架，正四角锥网架",{"id":483,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":484,"answer":27,"analysis":32},920399,[485,487,489,491],{"key":19,"text":486,"correct":25},"(Ⅰ)、(Ⅱ)上弦杆受力完全相同",{"key":23,"text":488,"correct":25},"(Ⅰ)、(Ⅱ)下弦杆受力完全相同",{"key":27,"text":490,"correct":21},"(Ⅰ)、(Ⅱ)竖腹杆受力完全相同",{"key":30,"text":492,"correct":25},"(Ⅰ)、(Ⅱ)斜腹杆受力完全相同",{"id":494,"libraryId":5,"type":8,"typeLabel":15,"stem":495,"options":496,"answer":19,"analysis":32},920400,"在竖向荷载作用下，梯形钢屋架上弦和下弦杆的内力为( )。",[497,499,501,503],{"key":19,"text":498,"correct":21},"压力和拉力",{"key":23,"text":500,"correct":25},"拉力和压力",{"key":27,"text":502,"correct":25},"均受压力",{"key":30,"text":504,"correct":25},"均受拉力",{"id":506,"libraryId":5,"type":8,"typeLabel":15,"stem":32,"options":507,"answer":19,"analysis":32},920401,[508,510,512,514],{"key":19,"text":509,"correct":21},"图(Ⅰ)中竖腹杆轴力从跨中到支座逐渐增大",{"key":23,"text":511,"correct":25},"图(Ⅰ)中斜腹杆与图(Ⅱ)中斜腹杆轴力最大值的绝对值相等",{"key":27,"text":513,"correct":25},"图(Ⅰ)中df杆与图(Ⅱ)中df杆受力相等",{"key":30,"text":515,"correct":25},"图(Ⅰ)中ce杆与图(Ⅱ)中ce杆受力相等",{"id":517,"libraryId":5,"type":8,"typeLabel":15,"stem":518,"options":519,"answer":27,"analysis":32},920402,"在计算8、9度罕遇地震时，建设场地的特征周期应( )。",[520,522,524,526],{"key":19,"text":521,"correct":25},"增加0.1s",{"key":23,"text":523,"correct":25},"减少0.1s",{"key":27,"text":525,"correct":21},"增加0.05s",{"key":30,"text":527,"correct":25},"减少0.05s",{"id":529,"libraryId":5,"type":8,"typeLabel":15,"stem":530,"options":531,"answer":23,"analysis":32},920403,"对于刚性方案房屋的横墙厚度不宜小于( )mm。",[532,534,536,538],{"key":19,"text":533,"correct":25},"120",{"key":23,"text":535,"correct":21},"180",{"key":27,"text":537,"correct":25},"240",{"key":30,"text":539,"correct":25},"300",{"id":541,"libraryId":5,"type":8,"typeLabel":15,"stem":542,"options":543,"answer":19,"analysis":32},920404,"关于木材强度设计值的取值，下列表述中符合规范要求的是( )。Ⅰ.矩形截面短边尺寸≥150mm时，可提高10%；Ⅱ.矩形截面短边尺寸≥150mm时，可降低10%；Ⅲ.采用湿材时，材料的横纹承压强度宜降低10%；Ⅳ.采用湿材时，材料的横纹承压强度可提高10%",[544,545,546,547],{"key":19,"text":195,"correct":21},{"key":23,"text":197,"correct":25},{"key":27,"text":199,"correct":25},{"key":30,"text":201,"correct":25},[549,552,555,558,562,564],{"id":8,"name":550,"category":7,"favorite":551},"领导干部任职前廉政法规知识测试题",92,{"id":553,"name":554,"category":7,"favorite":8},715,"招标采购专业知识与法律法规",{"id":556,"name":557,"category":7,"favorite":8},848,"市政方向-通用基础",{"id":559,"name":560,"category":7,"favorite":561},534,"BIM工程师",0,{"id":563,"name":560,"category":7,"favorite":561},535,{"id":565,"name":566,"category":7,"favorite":561},536,"安全人A证"]