[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-907906":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},907906,586,2,"多选题","（2020年真题）屋面保温层施工应满足的要求有（）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","先施工隔汽层再施工保温层",true,{"key":16,"text":17,"correct":14},"B","隔汽层沿墙面高于保温层",{"key":19,"text":20,"correct":21},"C","纤维材料保温层不宜采用机械固定法施工",false,{"key":23,"text":24,"correct":14},"D","现浇泡沫混凝土保温层现浇的自落高度≤1m",{"key":26,"text":27,"correct":14},"E","泡沫混凝土一次浇筑厚度≤200mm","ABDE","P251-255 选项AB正确，当设计有隔汽层时，先施工隔汽层，然后再施工保温层。隔汽层四周应向上沿墙面连续铺设，并高出保温层表面不得小于150mm。 选项C错误，纤维材料保温层施工时，应避免重压，并应采取防潮措施；屋面坡度较大时，宜采用机械固定法施工。 选项DE正确，现浇泡沫混凝土保温层施工时，浇筑出口离基层的高度不宜超过1m，泵送时应采取低压泵送。泡沫混凝土应分层浇筑，一次浇筑厚度不宜超过200mm。",{"id":6,"name":31,"category":32,"favorite":33},"建设工程技术与计量（土建）","建筑工程",0]