[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-907905":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},907905,586,2,"多选题","（2020年真题）地下防水工程防水混凝土正确的防水构造措施有（）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","竖向施工缝应设置在地下水和裂缝水较多的地段",false,{"key":16,"text":17,"correct":18},"B","竖向施工缝尽量与变形缝相结合",true,{"key":20,"text":21,"correct":18},"C","贯穿防水混凝土的铁件应在铁件上加焊止水铁片",{"key":23,"text":24,"correct":18},"D","贯穿铁件端部混凝土覆盖厚不少于250m",{"key":26,"text":27,"correct":18},"E","水平施工缝应避开底板与侧墙交接处","BCDE","P244-251 选项A错误，选项B正确，垂直施工缝应避开地下水和裂隙水较多的地段，并宜与变形缝相结合。 选项CD正确，为保证地下建筑的防水要求，可在铁件上加焊一道或数道止水铁片，延长渗水路径、减小渗水压力，达到防水目的。埋设件端部或预留孔、槽底部的混凝土厚度不得少于250mm；当混凝土厚度小于250mm时，应局部加厚或采取其他防水措施。 选项E正确，墙体水平施工缝不应留在剪力与弯矩最大处或底板与侧墙的交接处。",{"id":6,"name":31,"category":32,"favorite":33},"建设工程技术与计量（土建）","建筑工程",0]