[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-906595":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},906595,586,1,"单选题","沉井法施工时，采用湿封底时，为防止浮泥进入导管内，并获得比较平缓的混凝土表面坡度，导管下端插入混凝土的深度不宜小于（ ）m。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","0．5",false,{"key":16,"text":17,"correct":18},"B","1．0",true,{"key":20,"text":21,"correct":14},"C","1．5",{"key":23,"text":24,"correct":14},"D","2．0","2020版教材P325 本题考查的是地下工程特殊施工技术。湿封底即不排水封底，要求清除井底浮泥，并铺碎石垫层。若沉井锅底较深亦可抛填块石，再在上面铺碎石垫层，封底混凝土用导管法灌注，当封底面积较大时，宜用多根导管同时浇筑，以使混凝土能充满其底部全部面积，各导管的有效扩散面积互相搭接盖满井底全部范围。为防止进入导管内，并获得比较平缓的混凝土表面坡度，导管下端插入混凝土的深度不宜小于1m。",{"id":6,"name":27,"category":28,"favorite":29},"建设工程技术与计量（土建）","建筑工程",0]