[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-905295":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},905295,585,2,"多选题","关于水工隧道灌浆，下列说法错误的有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","隧洞回填灌浆的浆液较浓，采用填压式灌浆",false,{"key":16,"text":17,"correct":18},"B","当隧洞具有8°以上坡度时，灌浆应从最低一端开始",true,{"key":20,"text":21,"correct":14},"C","水工隧洞灌浆大多为浅孔",{"key":23,"text":24,"correct":18},"D","隧洞回填与固结灌浆的检查孔的数量均不应少于基本孔的10%",{"key":26,"text":27,"correct":18},"E","在设计规定的压力下，起始10min内，灌入孔内的水灰比为2∶1的浆液不超过5L","BDE","AD两项，隧洞回填灌浆的浆液较浓，水灰比分为1∶1、0.8∶1、0.6∶1、0.5∶1四个比级，采用填压式灌浆。隧洞固结灌浆的浆液水灰比与岩基灌浆相同，灌浆方法与岩基浅孔固结灌浆类似。隧洞回填与固结灌浆的检查孔的数量均不应少于基本孔的5%。 B项，水工隧洞灌浆应先回填灌浆，后接触灌浆，最后固结灌浆。回填与固结灌浆均按分序加密的原则进行。当隧洞具有10°以上坡度时，灌浆应从最低一端开始。 C项，水工隧洞灌浆大多为浅孔，并在衬砌时预留灌浆孔（管）（砌石衬砌的隧洞除外），故多采用手风钻钻孔。 E项，回填灌浆检查孔的合格标准是：在设计规定的压力下，起始10min内，灌入孔内的水灰比为2∶1的浆液不超过10L。固结检查孔则仍用压水试验所求得的单位吸水率W值来检查。",{"id":6,"name":31,"category":32,"favorite":33},"建设工程技术与计量（水利）","建筑工程",0]