[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-583-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":601},{"id":5,"name":6,"category":7,"favorite":8},583,"建设工程技术与计量（安装)","建筑工程",0,7,50,2472,[13,34,46,58,70,82,94,106,118,130,142,154,166,177,186,198,210,222,234,246,258,270,282,294,306,318,330,342,354,366,377,389,401,413,425,435,445,457,469,481,490,502,514,524,533,545,557,569,581,593],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},900431,1,"单选题","(2017年)它能广泛应用于无机气体如硫氧化物、氮氢化物、硫化氢、氯化氢等有害气体的净化，同时能进行除尘，适用于处理气体量大的场合。与其他净化方法相比费用较低。这种有害气体净化方法为()。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","吸收法",true,{"key":24,"text":25,"correct":26},"B","吸附法",false,{"key":28,"text":29,"correct":26},"C","冷凝法",{"key":31,"text":32,"correct":26},"D","燃烧法","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},900432,"(2016年)某种通风机具有可逆转特性，在重量或功率相同的情况下，能提供较大的通风量和较高的风压，可用于铁路、公路隧道的通风换气。该风机为()。",[38,40,42,44],{"key":20,"text":39,"correct":26},"离心式通风机",{"key":24,"text":41,"correct":26},"普通轴流式通风机",{"key":28,"text":43,"correct":26},"贯流式通风机",{"key":31,"text":45,"correct":22},"射流式通风机",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},900433,"(2016年)依据《通用安装工程工程量计算规范》GB50856-2013的规定，工程量按设计图示外径尺寸以展开面积计算的通风管道是()。",[50,52,54,56],{"key":20,"text":51,"correct":26},"碳钢通风管道",{"key":24,"text":53,"correct":26},"铝板通风管道",{"key":28,"text":55,"correct":22},"玻璃钢通风管道",{"key":31,"text":57,"correct":26},"塑料通风管道",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},900434,"(2017年)防爆等级低的防爆通风机，叶轮和机壳的制作材料应为()。",[62,64,66,68],{"key":20,"text":63,"correct":26},"叶轮和机壳均用钢板",{"key":24,"text":65,"correct":26},"叶轮和机壳均用铝板",{"key":28,"text":67,"correct":26},"叶轮用钢板、机壳用铝板",{"key":31,"text":69,"correct":22},"叶轮用铝板、机壳用钢板",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},900435,"(2018年)某空气净化塔塔内设有开孔率较大的筛板，筛板上放置一定数量的轻质小球，吸收剂自上向下喷淋，加湿小球表面进行吸收。该空气净化塔为（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"筛板塔",{"key":24,"text":77,"correct":26},"喷淋塔",{"key":28,"text":79,"correct":26},"填料塔",{"key":31,"text":81,"correct":22},"湍流塔",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},900436,"(2018年)事故通风系统中，室外排风口应布置在（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"有害气体散发量可能最大处",{"key":24,"text":89,"correct":26},"建筑物外墙靠近事故处",{"key":28,"text":91,"correct":22},"高出20m 范围内最高建筑物的屋面3m 以上处",{"key":31,"text":93,"correct":26},"人员经常通行处",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},900437,"(2018年)通过有组织的气流流动，控制有害物的扩散和转移，保证操作人员呼吸区内的空气达到卫生标准要求。它具有通风量小，控制效果好等优点。这种通风方式为（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"稀释通风",{"key":24,"text":101,"correct":22},"单向流通风",{"key":28,"text":103,"correct":26},"均匀流通风",{"key":31,"text":105,"correct":26},"置换通风",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},900439,"(2013年)公称直径为70mm的压缩空气管道，其连接方式宜采用()。",[110,112,114,116],{"key":20,"text":111,"correct":26},"法兰连接",{"key":24,"text":113,"correct":26},"螺纹连接",{"key":28,"text":115,"correct":22},"焊接",{"key":31,"text":117,"correct":26},"套管连接",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},900440,"(2013年)壁厚为5mm的不锈钢管道安装时，应采用的焊接方法为()。",[122,124,126,128],{"key":20,"text":123,"correct":26},"手工电弧焊",{"key":24,"text":125,"correct":26},"钨极氩弧焊",{"key":28,"text":127,"correct":26},"埋弧焊",{"key":31,"text":129,"correct":22},"氩电联焊",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},900441,"(2014年)铜及铜合金管切割，宜采用的切割方式为()。",[134,136,138,140],{"key":20,"text":135,"correct":26},"氧-乙炔焰切割",{"key":24,"text":137,"correct":26},"氧丙烷焰切割",{"key":28,"text":139,"correct":26},"氧-氢火焰切割",{"key":31,"text":141,"correct":22},"砂轮切管机切割",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},900442,"(2016年)依据《通用安装工程工程量计算规范》GB50856-2013的规定，执行“工业管道工程”相关项目的有()",[146,148,150,152],{"key":20,"text":147,"correct":22},"厂区范围内的各种生产用介质输送管道安装",{"key":24,"text":149,"correct":26},"厂区范围内的各种生活介质输送管道安装",{"key":28,"text":151,"correct":26},"厂区范围内生产、生活共用介质输送管理安装",{"key":31,"text":153,"correct":26},"厂区范围内的管道除锈，刷油及保温工程",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},900443,"(2017年)从技术和经济角度考虑，在人行频繁、非机动车辆通行的地方敷设热力管道，宜采用的敷设方式为()。",[158,160,162,164],{"key":20,"text":159,"correct":26},"地面敷设",{"key":24,"text":161,"correct":26},"低支架敷设",{"key":28,"text":163,"correct":22},"中支架敷设",{"key":31,"text":165,"correct":26},"高支架敷设",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":31,"analysis":33},900444,"(2017年)合金钢管道焊接时，底层应采用的焊接方式为()。",[170,172,173,175],{"key":20,"text":171,"correct":26},"焊条电弧焊",{"key":24,"text":127,"correct":26},{"key":28,"text":174,"correct":26},"CO2电弧焊",{"key":31,"text":176,"correct":22},"氩弧焊",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":33},900445,"(2017年)硬PVC管、ABS管广泛应用于排水系统中，其常用的连接方式为()。",[181,182,184,185],{"key":20,"text":115,"correct":26},{"key":24,"text":183,"correct":22},"粘接",{"key":28,"text":113,"correct":26},{"key":31,"text":111,"correct":26},{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":20,"analysis":33},900446,"(2016年)在一般的压缩空气站中，最广泛采用的空气压缩机形式为()。",[190,192,194,196],{"key":20,"text":191,"correct":22},"活塞式",{"key":24,"text":193,"correct":26},"回转式",{"key":28,"text":195,"correct":26},"离心式",{"key":31,"text":197,"correct":26},"轴流式",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":28,"analysis":33},900447,"(2013年)高压钢管验收时，当证明书与到货钢管的钢号或炉罐号不符、证明书的化学成分或力学性能不安全时，应进行核验性检查。当管外径大于或等于35mm时应做()。",[202,204,206,208],{"key":20,"text":203,"correct":26},"断口实验",{"key":24,"text":205,"correct":26},"冷弯实验",{"key":28,"text":207,"correct":22},"压扁实验",{"key":31,"text":209,"correct":26},"强度试验",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":28,"analysis":33},900448,"(2013年)设置在方形补偿器两侧的第一个支架形式应为()。",[214,216,218,220],{"key":20,"text":215,"correct":26},"固定支架",{"key":24,"text":217,"correct":26},"导向支架",{"key":28,"text":219,"correct":22},"滑动支架",{"key":31,"text":221,"correct":26},"弹簧吊架",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":24,"analysis":33},900449,"(2013年)在大型压缩空气站中，较多采用的压缩机除离心式空气压缩机外，还有()。",[226,228,230,232],{"key":20,"text":227,"correct":26},"活塞式空气压缩机",{"key":24,"text":229,"correct":22},"轴流式空气压缩机",{"key":28,"text":231,"correct":26},"回转式空气压缩机",{"key":31,"text":233,"correct":26},"往复式空气压缩机",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":28,"analysis":33},900450,"(2014年)热力管道直接埋地敷设时，在补偿器和自然转弯处应设置()。",[238,240,242,244],{"key":20,"text":239,"correct":26},"通行地沟",{"key":24,"text":241,"correct":26},"半通行地沟",{"key":28,"text":243,"correct":22},"不通行地沟",{"key":31,"text":245,"correct":26},"检查井",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":24,"analysis":33},900451,"(2014年)依据《通用安装工程工程量计算规范》(GB50856-2013)的规定，高压管道检验编码应列项在()。",[250,252,254,256],{"key":20,"text":251,"correct":26},"工业管道工程项目",{"key":24,"text":253,"correct":22},"措施项目",{"key":28,"text":255,"correct":26},"给水排水工程项目",{"key":31,"text":257,"correct":26},"采暖工程项目",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":31,"analysis":33},900452,"(2016年)不锈钢管道的切割宜采用的方式是()。",[262,264,266,268],{"key":20,"text":263,"correct":26},"氧一乙烷火焰切割",{"key":24,"text":265,"correct":26},"氧一氢火焰切割",{"key":28,"text":267,"correct":26},"碳氢气割",{"key":31,"text":269,"correct":22},"等离子切割",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":20,"analysis":33},900453,"(2017年)蒸汽夹套管系统安装完毕后，应用低压蒸汽吹扫，正确的吹扫顺序应为()。",[274,276,278,280],{"key":20,"text":275,"correct":22},"主管-支管-夹套管环隙",{"key":24,"text":277,"correct":26},"支管-主管-夹套管环隙",{"key":28,"text":279,"correct":26},"主管-夹套管环隙-支管",{"key":31,"text":281,"correct":26},"支管-夹套管环隙-主管",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":20,"analysis":33},900454,"(2018年)公称直径大于6mm 的高压奥氏体不锈钢管探伤，不能采用的探伤方法为（ ）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"磁力法",{"key":24,"text":289,"correct":26},"荧光法",{"key":28,"text":291,"correct":26},"着色法",{"key":31,"text":293,"correct":26},"超声波法",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":28,"analysis":33},900455,"(2018年)钛及钛合金管与其它金属管道连接时，宜采用的连接方式为（ ）。",[298,300,302,304],{"key":20,"text":299,"correct":26},"焊接连接",{"key":24,"text":301,"correct":26},"焊接法兰连接",{"key":28,"text":303,"correct":22},"活套法兰连接",{"key":31,"text":305,"correct":26},"卡套连接",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":28,"analysis":33},900456,"(2018年)当热力管道数量少、管径较小，单排水平敷设，距离较短、维修工作量不大和需要地下敷设时，宜采用敷设方式为（ ）。",[310,312,314,316],{"key":20,"text":311,"correct":26},"通行地沟敷设",{"key":24,"text":313,"correct":26},"半通行地沟敷设",{"key":28,"text":315,"correct":22},"不通行地沟敷设",{"key":31,"text":317,"correct":26},"直接埋地敷设",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},900458,"(2013年)敞开装设在金属框架上，保护和操作方案较多，装设地点灵活的低压断路器为()。",[322,324,326,328],{"key":20,"text":323,"correct":26},"SF6低压断路器",{"key":24,"text":325,"correct":22},"万能式低压断路器",{"key":28,"text":327,"correct":26},"塑壳式低压断路器",{"key":31,"text":329,"correct":26},"固定式低压断路器",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":31,"analysis":33},900459,"(2013年)根据《通用安装工程工程量计算规范》，单独安装的铁壳开关、自动开关、箱式电阻器、交阻器的外部进出线预留长度应从()。",[334,336,338,340],{"key":20,"text":335,"correct":26},"安装对象最远端子接口算起",{"key":24,"text":337,"correct":26},"安装对象最近端子接口算起",{"key":28,"text":339,"correct":26},"安装对象下端往上2\u002F3处算起",{"key":31,"text":341,"correct":22},"安装对象中心算起",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":31,"analysis":33},900460,"(2014年)变电所工程中，电容器室的主要作用是()。",[346,348,350,352],{"key":20,"text":347,"correct":26},"接受电力",{"key":24,"text":349,"correct":26},"分配电力",{"key":28,"text":351,"correct":26},"存储电能",{"key":31,"text":353,"correct":22},"提高功率因数",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":20,"analysis":33},900461,"(2014年)具有简单的灭弧装置，能通断一定的负荷电流和过负荷电流，但不能断开短路电流的高压变配电设备是()。",[358,360,362,364],{"key":20,"text":359,"correct":22},"高压负荷开关",{"key":24,"text":361,"correct":26},"高压隔离开关",{"key":28,"text":363,"correct":26},"真空断路器",{"key":31,"text":365,"correct":26},"SF6断路器",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":24,"analysis":33},900462,"(2014年)依据《通用安装工程工程量计算规范》(GB50856-2013)的规定，防雷及接地装置若利用基础钢筋作接地极，编码列项应在()。",[370,372,374,376],{"key":20,"text":371,"correct":26},"钢筋项目",{"key":24,"text":373,"correct":22},"均压环项目",{"key":28,"text":375,"correct":26},"接地极项目",{"key":31,"text":253,"correct":26},{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":28,"analysis":33},900463,"(2016年)变配电工程中，硬母线的连接方式应为()。",[381,383,385,387],{"key":20,"text":382,"correct":26},"扭纹链接",{"key":24,"text":384,"correct":26},"咬口连接",{"key":28,"text":386,"correct":22},"螺栓连接",{"key":31,"text":388,"correct":26},"铆接链接",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":28,"analysis":33},900464,"(2014年)低压动力配电箱的主要功能是()。",[393,395,397,399],{"key":20,"text":394,"correct":26},"只对动力设备配电",{"key":24,"text":396,"correct":26},"只对照明设备配电",{"key":28,"text":398,"correct":22},"不仅对动力设备配电，也可兼向照明设备配电",{"key":31,"text":400,"correct":26},"给小容量的单相动力设备配电",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":28,"analysis":33},900465,"(2017年)需用于频繁操作及有易燃易爆危险的场所，要求加工精度高，对其密封性能要求严的高压断路器，应选用()。",[405,407,409,411],{"key":20,"text":406,"correct":26},"多油断路器",{"key":24,"text":408,"correct":26},"少油断路器",{"key":28,"text":410,"correct":22},"六氟化硫断路器",{"key":31,"text":412,"correct":26},"空气断路器",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},900466,"(2017年)具有良好的非线性、动作迅速、残压低、通流容量大、无续流、结构简单、可靠性高、耐污能力强等优点，在电站及变电所中得到广泛应用的避雷器是()。",[417,419,421,423],{"key":20,"text":418,"correct":26},"碳化硅阀型避雷器",{"key":24,"text":420,"correct":22},"氧化锌避雷器",{"key":28,"text":422,"correct":26},"保护间隙避雷器",{"key":31,"text":424,"correct":26},"管型避雷器",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":31,"analysis":33},900467,"(2017年)依据《通用安装工程工程量计算规范》(GB50856-2013)的规定，利用基础钢筋作接地极，应执行的清单项目是()。",[429,430,432,434],{"key":20,"text":375,"correct":26},{"key":24,"text":431,"correct":26},"接地母线项目",{"key":28,"text":433,"correct":26},"基础钢筋项目",{"key":31,"text":373,"correct":22},{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":28,"analysis":33},900468,"(2013年)民用建筑物变电所内的高压开关，从安全角度考虑，一般不采用()。",[439,441,443,444],{"key":20,"text":440,"correct":26},"落地式真空断路器",{"key":24,"text":442,"correct":26},"手车式真空断路器",{"key":28,"text":408,"correct":22},{"key":31,"text":410,"correct":26},{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":20,"analysis":33},900469,"(2013年)母线安装时，母线引下线从右至左排列，正确的相序为()。",[449,451,453,455],{"key":20,"text":450,"correct":22},"NCBA",{"key":24,"text":452,"correct":26},"NABC",{"key":28,"text":454,"correct":26},"ABCN",{"key":31,"text":456,"correct":26},"CBAN",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},900470,"(2016年)10kV及以下变配电室经常设有高压负荷开关，其特点为()。",[461,463,465,467],{"key":20,"text":462,"correct":26},"能够断开短路电流",{"key":24,"text":464,"correct":22},"能够切断工作电流",{"key":28,"text":466,"correct":26},"没有明显的断开间隙",{"key":31,"text":468,"correct":26},"没有灭弧装置",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":31,"analysis":33},900471,"(2016年)防雷接地系统户外接地母线大部分采用扁钢埋地敷设，其连接应采用的焊接方式为()。",[473,475,477,479],{"key":20,"text":474,"correct":26},"端接焊",{"key":24,"text":476,"correct":26},"对接焊",{"key":28,"text":478,"correct":26},"角接焊",{"key":31,"text":480,"correct":22},"搭接焊",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":20,"analysis":33},900472,"(2017年)防雷接地系统避雷针与引下线之间的连接方式应采用()。",[485,486,487,488],{"key":20,"text":299,"correct":22},{"key":24,"text":384,"correct":26},{"key":28,"text":386,"correct":26},{"key":31,"text":489,"correct":26},"铆接连接",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":20,"analysis":33},900473,"(2018年)依据《通用安装工程工程量计算规范》(GB50856-2013)电气设备安装工程量计算规则，配线进入箱、柜、板的预留长度应为盘面尺寸（ ）。",[494,496,498,500],{"key":20,"text":495,"correct":22},"高+宽",{"key":24,"text":497,"correct":26},"高",{"key":28,"text":499,"correct":26},"宽",{"key":31,"text":501,"correct":26},"按实计算",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":24,"analysis":33},900474,"(2018年)电气线路工程中，考虑质量安全和经济性等，郊区0.4kV 室外架空线路应选用的导线型式为（ ）。",[506,508,510,512],{"key":20,"text":507,"correct":26},"多芯铝绞裸导线",{"key":24,"text":509,"correct":22},"多芯铝绞绝缘线",{"key":28,"text":511,"correct":26},"多芯铜绞裸导线",{"key":31,"text":513,"correct":26},"多芯铜绞绝缘线",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":24,"analysis":33},900475,"(2018年)具有明显可见的断开间隙和简单的灭弧装置，能通断一定的负荷电流和过负荷电流，但不能断开短路电流。该电气设备是（ ）。",[518,520,521,522],{"key":20,"text":519,"correct":26},"高压断路器",{"key":24,"text":359,"correct":22},{"key":28,"text":361,"correct":26},{"key":31,"text":523,"correct":26},"高压熔断器",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":31,"analysis":33},900476,"(2018年)变电所工程中，控制室的主要作用是（ ）。",[528,529,530,531],{"key":20,"text":347,"correct":26},{"key":24,"text":349,"correct":26},{"key":28,"text":353,"correct":26},{"key":31,"text":532,"correct":22},"预告信号",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":31,"analysis":33},900477,"(2014年)基于测量系统中弹簧管在被测介质的压力作用下，迫使弹簧管的末端产生相应的弹性变形，借助拉杆经齿轮传动机构的传动并予以放大，由固定齿轮上的指示装置将被测值在度盘上指示出来的压力仪表是()。",[537,539,541,543],{"key":20,"text":538,"correct":26},"隔膜式压力表",{"key":24,"text":540,"correct":26},"压力传感器",{"key":28,"text":542,"correct":26},"远传压力表",{"key":31,"text":544,"correct":22},"电接点压力表",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":24,"analysis":33},900478,"(2016年)在自动控制系统中，控制输入信号与主反馈信号之差，称为()。",[549,551,553,555],{"key":20,"text":550,"correct":26},"反馈信号",{"key":24,"text":552,"correct":22},"偏差信号",{"key":28,"text":554,"correct":26},"误差信号",{"key":31,"text":556,"correct":26},"扰动信号",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":28,"analysis":33},900479,"(2016年)能够对空气、氮气、水及与水相似的其他安全流体进行小流量测量，其结构简单、维修方便、价格较便宜、测量精度低。该流量测量仪表为()。",[561,563,565,567],{"key":20,"text":562,"correct":26},"涡轮流量计",{"key":24,"text":564,"correct":26},"椭圆齿轮流量计",{"key":28,"text":566,"correct":22},"玻璃管转子流量计",{"key":31,"text":568,"correct":26},"电磁流量计",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":24,"analysis":33},900480,"(2017年)自动控制系统中，将接收变换和放大后的偏差信号，转换为被控对象进行操作的控制信号。该装置为()。",[573,575,577,579],{"key":20,"text":574,"correct":26},"转换器",{"key":24,"text":576,"correct":22},"控制器",{"key":28,"text":578,"correct":26},"接收器",{"key":31,"text":580,"correct":26},"执行器",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":20,"analysis":33},900481,"(2017年)用于测量低压、负压的压力表，被广泛用于实验室压力测量或现场锅炉烟、风通道各段压力及通风空调系统各段压力的测量。它结构简单，使用、维修方便，但信号不能远传，该压力检测仪表为()。",[585,587,589,591],{"key":20,"text":586,"correct":22},"液柱式压力计",{"key":24,"text":588,"correct":26},"活塞式压力计",{"key":28,"text":590,"correct":26},"弹性式压力计",{"key":31,"text":592,"correct":26},"电动式压力计",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":31,"analysis":33},900482,"(2013年)适用于精密地、连续或间断地测量管道中液体的流量或瞬时流量，特别适用于重油、聚乙烯醇、树脂等黏度较高介质的流量测量。这种流量计为()。",[597,598,599,600],{"key":20,"text":566,"correct":26},{"key":24,"text":568,"correct":26},{"key":28,"text":562,"correct":26},{"key":31,"text":564,"correct":22},[602,605,608,611,614,617],{"id":15,"name":603,"category":7,"favorite":604},"领导干部任职前廉政法规知识测试题",92,{"id":606,"name":607,"category":7,"favorite":15},595,"建筑结构与设备",{"id":609,"name":610,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":612,"name":613,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":615,"name":616,"category":7,"favorite":8},534,"BIM工程师",{"id":618,"name":616,"category":7,"favorite":8},535]