[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-583-45":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":618},{"id":5,"name":6,"category":7,"favorite":8},583,"建设工程技术与计量（安装)","建筑工程",0,45,50,2472,[13,35,47,60,73,85,98,111,124,136,148,158,169,181,189,201,209,221,233,245,257,269,281,293,305,317,329,341,353,366,378,390,403,415,427,439,451,463,475,487,498,510,521,533,545,557,570,582,594,606],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},902410,2,"多选题","压缩空气站的空气过滤器种类很多，应用较广泛的有（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","金属网空气过滤器",true,{"key":24,"text":25,"correct":22},"B","填充纤维空气过滤器",{"key":27,"text":28,"correct":29},"C","自动浸水空气过滤器",false,{"key":31,"text":32,"correct":22},"D","袋式过滤器","ABD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},902411,"为了充分发挥填料塔的传质效能，填料应符合的要求有（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"较大的比表面积",{"key":24,"text":42,"correct":22},"良好的湿润性能",{"key":27,"text":44,"correct":29},"气液通过能力小",{"key":31,"text":46,"correct":22},"较高的空隙率",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":34},902412,"筛板塔的突出优点有（ ）。",[51,53,55,57],{"key":20,"text":52,"correct":22},"气体压降小",{"key":24,"text":54,"correct":22},"板上液面落差较小",{"key":27,"text":56,"correct":22},"生产能力较泡罩塔高",{"key":31,"text":58,"correct":29},"操作弹性范围较宽","ABC",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},902413,"单层壳体结构的球罐最为常见，多用于（ ）。",[64,66,68,70],{"key":20,"text":65,"correct":29},"常温常压场合",{"key":24,"text":67,"correct":22},"常温高压场合",{"key":27,"text":69,"correct":22},"高温中压场合",{"key":31,"text":71,"correct":29},"高温高压场合","BC",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":59,"analysis":34},902414,"板式塔设备中，浮动喷射塔的优点有()",[77,79,81,83],{"key":20,"text":78,"correct":22},"生产能力大",{"key":24,"text":80,"correct":22},"操作弹性大",{"key":27,"text":82,"correct":22},"持液量小",{"key":31,"text":84,"correct":29},"液量大时板效率提高",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":97,"analysis":34},902415,"U形管换热器和其他列管式换热器相比较，具有的优势为()。",[89,91,93,95],{"key":20,"text":90,"correct":22},"适用于高温和高压的场所",{"key":24,"text":92,"correct":29},"管板利用率高",{"key":27,"text":94,"correct":29},"管内易清洗",{"key":31,"text":96,"correct":22},"重量轻","AD",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":110,"analysis":34},902416,"固定管板换热器的特点有()。",[102,104,106,108],{"key":20,"text":103,"correct":29},"传热面积可适当调整",{"key":24,"text":105,"correct":29},"适用于两流体温差较大时(大于70℃)",{"key":27,"text":107,"correct":22},"两端管板和壳体连接成一体",{"key":31,"text":109,"correct":22},"结构简单、造价低廉","CD",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":123,"analysis":34},902417,"球罐水压试验过程中要进行基础沉降观测，并做好实测记录。正确的观测时点为（ ）。",[115,117,119,121],{"key":20,"text":116,"correct":22},"充水前",{"key":24,"text":118,"correct":29},"充水到1／2球罐本体高度",{"key":27,"text":120,"correct":22},"充满水24h",{"key":31,"text":122,"correct":22},"放水后","ACD",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":123,"analysis":34},902418,"在气柜总体实验中，进行气柜的气密性试验和快速升降试验的目的是检查()。",[128,130,132,134],{"key":20,"text":129,"correct":22},"各中节、钟罩在升降时的性能",{"key":24,"text":131,"correct":29},"气柜壁板焊缝的焊接质量",{"key":27,"text":133,"correct":22},"各导轮、导轨、配合及工作情况",{"key":31,"text":135,"correct":22},"整体气柜密封性能",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":33,"analysis":34},902419,"球罐安装完成后，要进行整体热处理，其目的是()。",[140,142,144,146],{"key":20,"text":141,"correct":22},"提高耐疲劳强度",{"key":24,"text":143,"correct":22},"改善焊缝的力学性能",{"key":27,"text":145,"correct":29},"提高球罐的内应力",{"key":31,"text":147,"correct":22},"稳定球罐几何尺寸",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":157,"analysis":34},902420,"表征填料效能好的有（ ）。",[152,153,154,155],{"key":20,"text":46,"correct":22},{"key":24,"text":80,"correct":29},{"key":27,"text":40,"correct":22},{"key":31,"text":156,"correct":29},"重量轻、造价低，有足够机械强度","AC",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":157,"analysis":34},902421,"浮阀塔结构简单，制造方便，节省材料，广泛用于化工及炼油生产中。它具有下列优点（ ）。",[162,163,165,167],{"key":20,"text":78,"correct":22},{"key":24,"text":164,"correct":29},"气体压降及液面落差较大",{"key":27,"text":166,"correct":22},"塔体板效率高",{"key":31,"text":168,"correct":29},"操作弹性小",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":72,"analysis":34},902423,"气柜按储气压力大小可分为（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":29},"常压储气柜",{"key":24,"text":176,"correct":22},"低压储气柜",{"key":27,"text":178,"correct":22},"高压储气柜",{"key":31,"text":180,"correct":29},"超高压储气柜",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":33,"analysis":34},902424,"球罐安装完成后，要进行整体热处理，其目的是（ ）。",[185,186,187,188],{"key":20,"text":141,"correct":22},{"key":24,"text":143,"correct":22},{"key":27,"text":145,"correct":29},{"key":31,"text":147,"correct":22},{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":59,"analysis":34},902425,"下列对于舌形塔板的特点，表述正确的有（ ）。",[193,195,197,199],{"key":20,"text":194,"correct":22},"开孔率较大",{"key":24,"text":196,"correct":22},"生产能力比泡罩塔大",{"key":27,"text":198,"correct":22},"操作灵敏",{"key":31,"text":200,"correct":29},"压降大",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":123,"analysis":34},902426,"在气柜总体实验中，进行气柜的气密性试验和快速升降试验的目的是检查（ ）。",[205,206,207,208],{"key":20,"text":129,"correct":22},{"key":24,"text":131,"correct":29},{"key":27,"text":133,"correct":22},{"key":31,"text":135,"correct":22},{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":59,"analysis":34},902427,"在相同容积和相同压力下，与立式圆筒形储罐相比，球形罐的优点为（ ）。",[213,215,217,219],{"key":20,"text":214,"correct":22},"表面积最小，可减少钢材消耗",{"key":24,"text":216,"correct":22},"罐壁内应力小，承载能力比圆筒形储罐大",{"key":27,"text":218,"correct":22},"基础工程量小，占地面积较小，节省土地",{"key":31,"text":220,"correct":29},"加工工艺简单，可大大缩短施工工期",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":59,"analysis":34},902428,"设计为室内给水系统总立管的球墨铸铁管可采用（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":22},"橡胶圈机械式接口",{"key":24,"text":228,"correct":22},"承插接口",{"key":27,"text":230,"correct":22},"螺纹法兰连接",{"key":31,"text":232,"correct":29},"青铅接口",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":72,"analysis":34},902429,"当管径大于50mm 时，宜采用（ ）。",[237,239,241,243],{"key":20,"text":238,"correct":29},"球阀",{"key":24,"text":240,"correct":22},"闸阀",{"key":27,"text":242,"correct":22},"蝶阀",{"key":31,"text":244,"correct":29},"快开阀",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":110,"analysis":34},902430,"铸铁排水管材宜采用A 型柔性法兰接口的是（ ）。",[249,251,253,255],{"key":20,"text":250,"correct":29},"排水支管",{"key":24,"text":252,"correct":29},"排水立管",{"key":27,"text":254,"correct":22},"排水横干管",{"key":31,"text":256,"correct":22},"首层出户管",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":123,"analysis":34},902431,"止回阀应装设在（ ），阻止水逆流输配。",[261,263,265,267],{"key":20,"text":262,"correct":22},"闭式水加热器和贮水器的给水供水管上",{"key":24,"text":264,"correct":29},"热媒为蒸汽的有背压疏水器前的管道上",{"key":27,"text":266,"correct":22},"加热水箱与其补给水箱的连通管上",{"key":31,"text":268,"correct":22},"热水供应管网的回水管上",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":33,"analysis":34},902432,"下述有关检查口设置正确的是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":22},"立管上检查口之间的距离不大于10m",{"key":24,"text":276,"correct":22},"最低层和设有卫生器具的二层以上坡屋顶建筑物的最高层设置检查口",{"key":27,"text":278,"correct":29},"平顶建筑的通气管顶口不可用来代替检查口",{"key":31,"text":280,"correct":22},"立管的乙字管的上部应设检查口",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":72,"analysis":34},902433,"对于以下采暖系统入口装置的安装，说法正确的是（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":29},"供热系统较大时宜采用截止阀调节",{"key":24,"text":288,"correct":22},"平衡阀应安装在回水管路的直管段",{"key":27,"text":290,"correct":22},"入口处设置除污器或过滤器",{"key":31,"text":292,"correct":29},"热量表的额定流量为设计流量",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":97,"analysis":34},902434,"室外燃气聚乙烯（P E）管道安装采用的连接方式有（ ）。",[297,299,301,303],{"key":20,"text":298,"correct":22},"电熔连接",{"key":24,"text":300,"correct":29},"螺纹连接",{"key":27,"text":302,"correct":29},"粘接",{"key":31,"text":304,"correct":22},"热熔连接",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":72,"analysis":34},902435,"空调按承担室内负荷的输送介质分类，属于空气一水系统的是（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":29},"风机盘管系统",{"key":24,"text":312,"correct":22},"带盘管的诱导系统",{"key":27,"text":314,"correct":22},"风机盘管机组加新风系统",{"key":31,"text":316,"correct":29},"辐射板系统等",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":157,"analysis":34},902436,"空调冷凝水管道宜采用的材质是（ ）。",[321,323,325,327],{"key":20,"text":322,"correct":22},"聚氯乙烯塑料管",{"key":24,"text":324,"correct":29},"铸铁管",{"key":27,"text":326,"correct":22},"热镀锌钢管",{"key":31,"text":328,"correct":29},"焊接钢管",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":72,"analysis":34},902437,"有关风管连接表述正确的是（ ）。",[333,335,337,339],{"key":20,"text":334,"correct":29},"铝板风管法兰连接可采用增强尼龙螺栓",{"key":24,"text":336,"correct":22},"硬聚氯乙烯风管和法兰连接可采用镀锌螺栓",{"key":27,"text":338,"correct":22},"软管连接可用于风管与部件连接",{"key":31,"text":340,"correct":29},"风管在刷油、绝热后进行严密性、漏风量检测",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":72,"analysis":34},902438,"空调系统热交换器安装时，蒸汽加热器入口的管路上应安装（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":29},"温度计",{"key":24,"text":348,"correct":22},"压力表",{"key":27,"text":350,"correct":22},"调节阀",{"key":31,"text":352,"correct":29},"疏水阀",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":365,"analysis":34},902439,"在通风空调系统中，以“㎡”为计量单位的是（ ）。",[357,359,361,363],{"key":20,"text":358,"correct":29},"风机盘管",{"key":24,"text":360,"correct":22},"柔性接口",{"key":27,"text":362,"correct":29},"柔性软风管",{"key":31,"text":364,"correct":22},"风管漏光试验、漏风试验","BD",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":59,"analysis":34},902440,"下列有关热力管道上补偿器安装，说法正确的是（ ）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"水平安装的方形补偿器应与管道保持同一坡度，垂直臂应呈水平",{"key":24,"text":373,"correct":22},"方形补偿器两侧的第一个支架为滑动支架",{"key":27,"text":375,"correct":22},"填料式补偿器活动侧管道的支架应为导向支架",{"key":31,"text":377,"correct":29},"单向填料式补偿器应装在固定支架中间",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":110,"analysis":34},902441,"衬胶管道预制时，对于现场加工的钢制弯管，说法正确的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":29},"衬里完成后进行弯管",{"key":24,"text":385,"correct":29},"弯曲角度大于90°",{"key":27,"text":387,"correct":22},"弯曲半径不小于管外径的4 倍",{"key":31,"text":389,"correct":22},"只允许一个平面弯",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":402,"analysis":34},902442,"公称直径为32mm 的奥氏体不锈钢管探伤应采用（ ）。",[394,396,398,400],{"key":20,"text":395,"correct":29},"磁力法",{"key":24,"text":397,"correct":22},"荧光法",{"key":27,"text":399,"correct":22},"着色法",{"key":31,"text":401,"correct":22},"超声波法","BCD",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":59,"analysis":34},902443,"高压钢管验收时，当管子外径大于或等于35mm 时做（ ）。",[407,409,411,413],{"key":20,"text":408,"correct":22},"拉力试验两个",{"key":24,"text":410,"correct":22},"冲击试验两个",{"key":27,"text":412,"correct":22},"压扁试验一个",{"key":31,"text":414,"correct":29},"冷弯试验一个",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":59,"analysis":34},902444,"对于高压管道安装，说法正确的是（ ）。",[419,421,423,425],{"key":20,"text":420,"correct":22},"高压阀门应逐个进行强度和严密性试验",{"key":24,"text":422,"correct":22},"高压管道中心线弯曲半径R>5D（管道外径）",{"key":27,"text":424,"correct":22},"奥氏体不锈钢高压管热处理次数不得超过3 次",{"key":31,"text":426,"correct":29},"壁厚为16～34mm 的高压钢管采用V 型坡口",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":123,"analysis":34},902445,"应在焊后立即进行热消氢处理的球罐焊缝有（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":22},"厚度大于32mm 的高强度钢",{"key":24,"text":434,"correct":29},"壁厚大于34mm 的碳钢",{"key":27,"text":436,"correct":22},"厚度大于38mm 的其他低合金钢",{"key":31,"text":438,"correct":22},"锻制凸缘与球壳板的对接焊缝",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":123,"analysis":34},902446,"球罐整体热处理的目的是为了（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":22},"消除球罐组焊产生的应力",{"key":24,"text":446,"correct":29},"稳定焊接金相组织",{"key":27,"text":448,"correct":22},"防止延迟裂纹产生",{"key":31,"text":450,"correct":22},"提高耐疲劳强度与蠕变强度",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":97,"analysis":34},902447,"有关球罐质量检验，说法正确的是（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":22},"对接焊缝应100%进行射线探伤和超声波探伤",{"key":24,"text":458,"correct":29},"球罐应在热处理后进行探伤",{"key":27,"text":460,"correct":29},"水压试验压力应为设计压力的1.5 倍",{"key":31,"text":462,"correct":22},"水压试验合格前后均需进行磁粉探伤或渗透探伤",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":72,"analysis":34},902448,"有关低压干式气柜，说法正确的是（ ）。",[467,469,471,473],{"key":20,"text":468,"correct":29},"基础费用高",{"key":24,"text":470,"correct":22},"煤气压力稳定",{"key":27,"text":472,"correct":22},"大容量贮气经济",{"key":31,"text":474,"correct":29},"无内部活动部件",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":157,"analysis":34},902449,"对于室内给水管道引入管的敷设，说法正确的是（ ）。",[479,481,483,485],{"key":20,"text":480,"correct":22},"引入管上应装设阀门、水表和止回阀",{"key":24,"text":482,"correct":29},"引入管上应绕水表旁设旁通管",{"key":27,"text":484,"correct":22},"环状管网应有2 条或2 条以上引入管",{"key":31,"text":486,"correct":29},"枝状管网只需1 条引入管",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":59,"analysis":34},902450,"室外给水管网允许直接吸水时，水泵的进水管和出水管上均应设置（ ）。",[491,493,495,496],{"key":20,"text":492,"correct":22},"阀门",{"key":24,"text":494,"correct":22},"止回阀",{"key":27,"text":348,"correct":22},{"key":31,"text":497,"correct":29},"防水锤措施",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":365,"analysis":34},902451,"有关环形通气管的设置与安装，说法正确的是（ ）。",[502,504,506,508],{"key":20,"text":503,"correct":29},"与排水立管的距离大于12m 的污水横支管上需设置",{"key":24,"text":505,"correct":22},"连接6 个及以上大便器的污水横支管上需设置",{"key":27,"text":507,"correct":29},"在横支管最末端的两个卫生器具间接出",{"key":31,"text":509,"correct":22},"在排水支管中心线以上与排水管呈垂直或45°连接",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":157,"analysis":34},902452,"室外采暖管道采用的管材有（ ）。",[514,516,517,519],{"key":20,"text":515,"correct":22},"无缝钢管",{"key":24,"text":328,"correct":29},{"key":27,"text":518,"correct":22},"钢板卷焊管",{"key":31,"text":520,"correct":29},"镀锌钢管",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":33,"analysis":34},902453,"有关采暖管道安装，符合要求的是（ ）。",[525,527,529,531],{"key":20,"text":526,"correct":22},"管径大于32mm 宜采用焊接或法兰连接",{"key":24,"text":528,"correct":22},"共用立管宜采用热镀锌钢管螺纹连接",{"key":27,"text":530,"correct":29},"管道穿外墙或基础时应加设填料套管",{"key":31,"text":532,"correct":22},"一对共用立管每层连接的户数不宜大于三户",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":72,"analysis":34},902454,"室内热水采暖系统试压，操作正确的是（ ）。",[537,539,541,543],{"key":20,"text":538,"correct":29},"在试压系统最高点设手压泵",{"key":24,"text":540,"correct":22},"关闭与室外系统相通的阀门",{"key":27,"text":542,"correct":22},"打开系统中全部阀门",{"key":31,"text":544,"correct":29},"试压时不能隔断锅炉和膨胀水箱",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":110,"analysis":34},902455,"出风均匀，进、出口均是矩形易与建筑配合，目前大量应用于空调挂机、空调扇、风幕机等设备产品中的是（ ）。",[549,551,553,555],{"key":20,"text":550,"correct":29},"离心式通风机",{"key":24,"text":552,"correct":29},"轴流式通风机",{"key":27,"text":554,"correct":22},"贯流式通风机",{"key":31,"text":556,"correct":22},"横流风机",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":569,"analysis":34},902456,"分体式空调机组中属于室外机的有（ ）。",[561,563,565,567],{"key":20,"text":562,"correct":22},"压缩机",{"key":24,"text":564,"correct":22},"冷凝器",{"key":27,"text":566,"correct":29},"送风机",{"key":31,"text":568,"correct":29},"加热器","AB",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":110,"analysis":34},902457,"风管制作时，镀锌钢板及含有各类复合保护层的钢板应采用的连接方法有（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":29},"电焊",{"key":24,"text":577,"correct":29},"气焊",{"key":27,"text":579,"correct":22},"咬口连接",{"key":31,"text":581,"correct":22},"铆接",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":123,"analysis":34},902458,"矩形风管无法兰连接形式有（ ）。",[586,588,590,592],{"key":20,"text":587,"correct":22},"插条连接",{"key":24,"text":589,"correct":29},"承插连接",{"key":27,"text":591,"correct":22},"立咬口连接",{"key":31,"text":593,"correct":22},"薄钢材法兰弹簧夹连接",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":97,"analysis":34},902459,"下列热力管道敷设时，适宜采用不通行地沟敷设的是（ ）。",[598,600,602,604],{"key":20,"text":599,"correct":22},"直接埋地敷设管道的补偿器处",{"key":24,"text":601,"correct":29},"管道数量多、管径较大、管道垂直排列宽度超过1.5m",{"key":27,"text":603,"correct":29},"直接埋地敷设管道的阀门处",{"key":31,"text":605,"correct":22},"管道数量少、管径较小、距离较短且维修工作量不大",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":157,"analysis":34},902460,"热力管道直接埋地敷设时，设置符合要求的是（ ）。",[610,612,614,616],{"key":20,"text":611,"correct":22},"在补偿器和自然转弯处设不通行地沟",{"key":24,"text":613,"correct":29},"不通行地沟的两端宜设置固定支架",{"key":27,"text":615,"correct":22},"在阀门处设置检查井",{"key":31,"text":617,"correct":29},"管道材料宜选用无缝钢管",[619,623,626,629,632,635],{"id":620,"name":621,"category":7,"favorite":622},1,"领导干部任职前廉政法规知识测试题",92,{"id":624,"name":625,"category":7,"favorite":620},595,"建筑结构与设备",{"id":627,"name":628,"category":7,"favorite":620},715,"招标采购专业知识与法律法规",{"id":630,"name":631,"category":7,"favorite":620},848,"市政方向-通用基础",{"id":633,"name":634,"category":7,"favorite":8},534,"BIM工程师",{"id":636,"name":634,"category":7,"favorite":8},535]