[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-583-43":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":617},{"id":5,"name":6,"category":7,"favorite":8},583,"建设工程技术与计量（安装)","建筑工程",0,43,50,2472,[13,35,48,61,73,85,98,111,123,136,149,161,173,185,198,211,223,235,247,259,271,283,295,307,319,331,343,356,368,380,392,401,413,425,437,449,459,468,476,488,500,512,524,536,548,560,569,581,593,605],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},902308,2,"多选题","同一泵组的消防水泵设置正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","消防水泵型号宜一致",true,{"key":24,"text":25,"correct":26},"B","工作泵不少于3 台",false,{"key":28,"text":29,"correct":22},"C","消防水泵的吸水管不应少于2 条",{"key":31,"text":32,"correct":22},"D","消防水泵的出水管上应安装止回阀和压力表","ACD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},902309,"与自动喷水灭火系统相比，水喷雾灭火系统具有的特点是（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"能够扑灭C 类电气火灾",{"key":24,"text":42,"correct":26},"水压低、水量小",{"key":28,"text":44,"correct":22},"用于高层建筑内的柴油机发电机房、燃油锅炉房",{"key":31,"text":46,"correct":26},"不具备直接灭火能力","AC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},902310,"水灭火系统的末端试水装置的安装包含（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":22},"压力表",{"key":24,"text":55,"correct":22},"控制阀",{"key":28,"text":57,"correct":26},"连接管",{"key":31,"text":59,"correct":26},"排水管","AB",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":60,"analysis":34},902311,"对于管喷道淋室系内统外水界灭线火的管划道分、，消说火法栓正确的是（ ）。",[65,67,69,71],{"key":20,"text":66,"correct":22},"以建筑物外墙皮1.5m 为界",{"key":24,"text":68,"correct":22},"入口处设阀门者以阀门为界",{"key":28,"text":70,"correct":26},"设在高层建筑物内消防泵间管道应以泵间外墙皮1.5m 为界",{"key":31,"text":72,"correct":26},"以与市政给水管道碰头点（井）为界",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":33,"analysis":34},902312,"以下电光源中，显色性好的灯有（ ）。",[77,79,81,83],{"key":20,"text":78,"correct":22},"白炽灯",{"key":24,"text":80,"correct":26},"高压钠灯",{"key":28,"text":82,"correct":22},"金属卤化物灯",{"key":31,"text":84,"correct":22},"氙灯",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":97,"analysis":34},902313,"与外流镇高流压式汞高灯压的水特银点灯是相（比，）自。镇",[89,91,93,95],{"key":20,"text":90,"correct":22},"显色性好",{"key":24,"text":92,"correct":22},"功率因数高",{"key":28,"text":94,"correct":26},"寿命长",{"key":31,"text":96,"correct":22},"发光效率高","ABD",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":110,"analysis":34},902314,"钢筋混凝土结构的电梯井道，稳固导轨架的方式是（ ）。",[102,104,106,108],{"key":20,"text":103,"correct":26},"埋入式",{"key":24,"text":105,"correct":22},"焊接式",{"key":28,"text":107,"correct":22},"预埋螺栓固定式",{"key":31,"text":109,"correct":22},"对穿螺栓固定式","BCD",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":110,"analysis":34},902315,"以下对于屏蔽泵主要特点描述正确的是（ ）。",[115,117,119,121],{"key":20,"text":116,"correct":26},"用屏蔽套将叶轮与电动机的转子隔离开来",{"key":24,"text":118,"correct":22},"可以保证绝对不泄漏",{"key":28,"text":120,"correct":22},"特别适用于输送腐蚀性、易燃易爆、剧毒、有放射性及极为贵重的液体",{"key":31,"text":122,"correct":22},"适用熔于点输的送液高体压、高温、低温及高",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":135,"analysis":34},902316,"与离心泵相比，往复泵具有的特点是（ ）。",[127,129,131,133],{"key":20,"text":128,"correct":22},"扬程无限高",{"key":24,"text":130,"correct":22},"流量与排出压力无关",{"key":28,"text":132,"correct":22},"具有自吸能力",{"key":31,"text":134,"correct":26},"流量均匀","ABC",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":148,"analysis":34},902317,"以下对于工业锅炉过热器安装说法正确的是（ ）。",[140,142,144,146],{"key":20,"text":141,"correct":26},"通常由支承架、带法兰的铸铁翼片管、铸铁弯头或蛇形管等组成",{"key":24,"text":143,"correct":22},"对流过热器大都垂直悬挂于锅炉尾部",{"key":28,"text":145,"correct":22},"辐射过热器多半装于锅炉的炉顶部或包覆于炉墙内壁上",{"key":31,"text":147,"correct":26},"过热器材料大多为铸铁","BC",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":135,"analysis":34},902318,"蒸发量大于0.5t\u002Fh 的蒸汽锅炉阀的安装和试验符合要求的是（ ）。",[153,155,157,159],{"key":20,"text":154,"correct":22},"安装前阀应逐个进行严密性试验",{"key":24,"text":156,"correct":22},"至少应装设两个阀（不包括省煤器上的阀）",{"key":28,"text":158,"correct":22},"阀应铅锤安装",{"key":31,"text":160,"correct":26},"按较高压力进行整定的阀必须是过热器上的阀",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":135,"analysis":34},902319,"属于燃烧前脱硫技术的是（ ）。",[165,167,169,171],{"key":20,"text":166,"correct":22},"洗选法",{"key":24,"text":168,"correct":22},"化学浸出法",{"key":28,"text":170,"correct":22},"微波法",{"key":31,"text":172,"correct":26},"石灰石\u002F石膏法",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":60,"analysis":34},902320,"有关消防水泵接合器设置符合要求的是（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":22},"消防车的水泵可通过消防接合器加压送水",{"key":24,"text":180,"correct":22},"水泵接合器处应设置永久性标志铭牌",{"key":28,"text":182,"correct":26},"水泵接合器应设在距室外消火栓15m 以内",{"key":31,"text":184,"correct":26},"水泵接合器应距离消防水池40m 上",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":197,"analysis":34},902321,"下列室内消火栓给水系统应设置消防水泵接合器的是（ ）。",[189,191,193,195],{"key":20,"text":190,"correct":26},"四层工业建筑",{"key":24,"text":192,"correct":26},"超过2 层或建筑面积大于10000 ㎡的地上建筑",{"key":28,"text":194,"correct":22},"高层民用建筑",{"key":31,"text":196,"correct":22},"室内消火栓设计流量大于10L\u002Fs 平战结合的人防工程","CD",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":210,"analysis":34},902322,"高层建筑采用临时高压给水系统时，说法正确的是（ ）。",[202,204,206,208],{"key":20,"text":203,"correct":22},"应设高位消防水箱并保证最不利点消火栓静水压力",{"key":24,"text":205,"correct":26},"发生火灾后由消防泵供给的水必须进入消防水箱",{"key":28,"text":207,"correct":26},"建筑高度超过100m 时的最不利点消火栓静水压力不应低于0.07MPa",{"key":31,"text":209,"correct":22},"不能满足静水压力要求时应设增压设施","AD",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":197,"analysis":34},902323,"室内消火栓给水管道的管径大于100mm 时，管道连接宜采用（ ）。",[215,217,219,221],{"key":20,"text":216,"correct":26},"螺纹连接",{"key":24,"text":218,"correct":26},"卡箍管接头",{"key":28,"text":220,"correct":22},"法兰连接",{"key":31,"text":222,"correct":22},"焊接",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":60,"analysis":34},902324,"对于喷水灭火系统报警阀组安装，说法正确的是（ ）。",[227,229,231,233],{"key":20,"text":228,"correct":22},"在供水管网试压、冲洗合格后安装",{"key":24,"text":230,"correct":22},"距室内地面高度宜为1.2m",{"key":28,"text":232,"correct":26},"正面与墙的距离不应小于0.5m",{"key":31,"text":234,"correct":26},"两侧与墙的距离不应小于1.2m",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":197,"analysis":34},902325,"非吸气型泡沫喷头能采用（ ）。",[239,241,243,245],{"key":20,"text":240,"correct":26},"蛋白泡沫液",{"key":24,"text":242,"correct":26},"氟蛋白泡沫液",{"key":28,"text":244,"correct":22},"水成膜泡沫液",{"key":31,"text":246,"correct":22},"成膜氟蛋白泡沫液",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":97,"analysis":34},902326,"符合灯器具安装一般规定的是（ ）。",[251,253,255,257],{"key":20,"text":252,"correct":22},"相线应接于螺口灯头中间触点的端子上",{"key":24,"text":254,"correct":22},"敞开式灯具的灯头对地面距离应大于2.5m",{"key":28,"text":256,"correct":26},"高低压配电设备的正上方应安装灯具",{"key":31,"text":258,"correct":22},"绝缘铜芯导线的线芯截面积不应小于1m ㎡",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":148,"analysis":34},902327,"对软启动器启动电动机的表述正确的是（ ）。",[263,265,267,269],{"key":20,"text":264,"correct":26},"采用在电路中串入电阻的方法起动",{"key":24,"text":266,"correct":22},"可靠性高、维护量小",{"key":28,"text":268,"correct":22},"可实现平稳启动和平稳停机",{"key":31,"text":270,"correct":26},"故障查找复杂",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":210,"analysis":34},902328,"对于磁力启动器，说法正确的是（ ）。",[275,277,279,281],{"key":20,"text":276,"correct":22},"磁力起动器由接触器、按钮和热继电器组成",{"key":24,"text":278,"correct":26},"两只接触器的主触头并联起来接入主电路",{"key":28,"text":280,"correct":26},"线圈串联起来接入控制电路",{"key":31,"text":282,"correct":22},"用于电动机不及时停转易造成事故的生产场合",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":197,"analysis":34},902329,"符合导线连接要求的是（ ）。",[287,289,291,293],{"key":20,"text":288,"correct":26},"2.5m ㎡及以下的多芯铜芯线应直接与设备或器具的端子连接",{"key":24,"text":290,"correct":26},"每个设备的端子接线不多于3 根导线",{"key":28,"text":292,"correct":22},"6m ㎡及以下的铜芯导线在多尘场所连接应选用IP5X 及以上的防护等级连接器",{"key":31,"text":294,"correct":22},"绝缘导线不得采用开口端子",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":60,"analysis":34},902330,"室内排水系统设置通气管的目的有()。",[299,301,303,305],{"key":20,"text":300,"correct":22},"减少排水管内空气压力波动",{"key":24,"text":302,"correct":22},"保护存水弯的水封不被破坏",{"key":28,"text":304,"correct":26},"防止排水管道被异物堵塞",{"key":31,"text":306,"correct":26},"防止外界空气异味进入排水管道内",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":148,"analysis":34},902331,"室内排水管道上需要设置双向清通的检查口，设置要求为()。",[311,313,315,317],{"key":20,"text":312,"correct":26},"立管上检查口之间的间距不大于12m",{"key":24,"text":314,"correct":22},"最底层和设有卫生器具的二层以上坡屋顶建筑物的最高层排水立管上应设置检查口",{"key":28,"text":316,"correct":22},"排水立管上如有乙字管，则应在乙字管的上部设置检查口",{"key":31,"text":318,"correct":26},"平顶建筑通气管顶口旁设置检查口",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":97,"analysis":34},902332,"采暖工程中，分户热计量采暖系统除包括分户水平单管系统外，还有()。",[323,325,327,329],{"key":20,"text":324,"correct":22},"分户水平双管系统",{"key":24,"text":326,"correct":22},"分户水平单双管系统",{"key":28,"text":328,"correct":26},"分户水平环状管网系统",{"key":31,"text":330,"correct":22},"分户水平放射式系统",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":97,"analysis":34},902333,"铸铁散热器的特点有()。",[335,337,339,341],{"key":20,"text":336,"correct":22},"结构简单，防腐性好",{"key":24,"text":338,"correct":22},"热稳定性好",{"key":28,"text":340,"correct":26},"传热系数高于的钢制散热器",{"key":31,"text":342,"correct":22},"价格便宜",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":355,"analysis":34},902334,"在燃气工程中，管道系统补偿器的形式有()。",[347,349,351,353],{"key":20,"text":348,"correct":26},"方形管补偿器",{"key":24,"text":350,"correct":22},"套筒式补偿器",{"key":28,"text":352,"correct":26},"自然补偿器",{"key":31,"text":354,"correct":22},"波形管补偿器","BD",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":60,"analysis":34},902335,"下列关于室内燃气管道管材和管件的选用，叙述正确的是()。",[360,362,364,366],{"key":20,"text":361,"correct":22},"低压管道当管径DN≤50时，一般选用镀锌钢管，连接方式为螺纹连接",{"key":24,"text":363,"correct":22},"当管径DN>50时，选用无缝钢管，连接方式为焊接或法兰连接",{"key":28,"text":365,"correct":26},"明装采用镀锌钢管，焊接",{"key":31,"text":367,"correct":26},"埋地敷设采用无缝钢管，丝扣连接",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":60,"analysis":34},902336,"下列关于燃气聚乙烯(P E)管的连接，叙述正确的是()。",[372,374,376,378],{"key":20,"text":373,"correct":22},"当De≤90mm时，宜采用电熔连接",{"key":24,"text":375,"correct":22},"当De≥110mm时，宜采用热熔连接",{"key":28,"text":377,"correct":26},"采用螺纹连接",{"key":31,"text":379,"correct":26},"采用螺纹粘接",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":47,"analysis":34},902337,"为提高燃气压力或输送燃气，目前在中、低压两级燃气输送系统中使用的压送设备有()。",[384,386,388,390],{"key":20,"text":385,"correct":22},"罗茨式鼓风机",{"key":24,"text":387,"correct":26},"螺杆式鼓风机",{"key":28,"text":389,"correct":22},"往复式压送机",{"key":31,"text":391,"correct":26},"透平式压送机",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":197,"analysis":34},902338,"室内燃气中压管道，选用无缝钢管，其连接方式应为()。",[396,397,399,400],{"key":20,"text":216,"correct":26},{"key":24,"text":398,"correct":26},"卡箍连接",{"key":28,"text":222,"correct":22},{"key":31,"text":220,"correct":22},{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":33,"analysis":34},902339,"给水管道防冻防结露的方法是对管道进行绝热，常用的绝热层材料有()。",[405,407,409,411],{"key":20,"text":406,"correct":22},"聚氨酯",{"key":24,"text":408,"correct":26},"石棉",{"key":28,"text":410,"correct":22},"岩棉",{"key":31,"text":412,"correct":22},"毛毡",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":47,"analysis":34},902340,"燃气工程管道系统安装完毕后，应对管道进行吹扫，吹扫时应满足的条件有()。",[417,419,421,423],{"key":20,"text":418,"correct":22},"吹扫介质为压缩空气",{"key":24,"text":420,"correct":26},"吹扫流速不宜低于10m／s",{"key":28,"text":422,"correct":22},"吹扫压力不应大于工作压力",{"key":31,"text":424,"correct":26},"在管道压力试验后进行吹扫",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":97,"analysis":34},902341,"采暖工程热网布置形式中，环状管网的特点为()。",[429,431,433,435],{"key":20,"text":430,"correct":22},"投资大",{"key":24,"text":432,"correct":22},"运行管理复杂",{"key":28,"text":434,"correct":26},"适用于面积小、厂房密集的小型工厂",{"key":31,"text":436,"correct":22},"管网要有较高的自动控制措施",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":110,"analysis":34},902342,"下列室内燃气管道安装要求，叙述正确的是()。",[441,443,445,447],{"key":20,"text":442,"correct":26},"引入管坡度不得小于1‰",{"key":24,"text":444,"correct":22},"燃气引入管不得敷设在卧室、浴室、密闭地下室",{"key":28,"text":446,"correct":22},"居民用户的引入管应尽量直接引入厨房内",{"key":31,"text":448,"correct":22},"公共设施的引入管，应尽量直接引至安装燃气设备或燃气表的房间内",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":60,"analysis":34},902343,"依据《通用安装工程工程量计算规范》（GB 50856—2013），给排水和采暖管道附件以“组”为单位计量的有（ ）。 A.浮标液面计 B.水表 C.浮漂水位标尺 D.热量表",[453,454,455,456,457],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"key":458,"text":458,"correct":26},"E",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":33,"analysis":34},902344,"为保证地板表面温度均匀，地板辐射采暖系统的加热管布置应采用的形式有（ ）。 A.平行排管 B.枝形排管 C.蛇形排管 D.蛇形盘管",[463,464,465,466,467],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"key":458,"text":458,"correct":26},{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":97,"analysis":34},902345,"采暖工程热网布置形式中，环状管网的特点为（ ）。",[472,473,474,475],{"key":20,"text":430,"correct":22},{"key":24,"text":432,"correct":22},{"key":28,"text":434,"correct":26},{"key":31,"text":436,"correct":22},{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":33,"analysis":34},902346,"采暖工程中，分户热计量分室温度控制系统装置包括（ ）。",[480,482,484,486],{"key":20,"text":481,"correct":22},"锁闭阀",{"key":24,"text":483,"correct":26},"平衡网",{"key":28,"text":485,"correct":22},"散热器温控阀",{"key":31,"text":487,"correct":22},"热量分配表",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":135,"analysis":34},902347,"采暖工程中，热风采暖系统适用的场合有（ ）。",[492,494,496,498],{"key":20,"text":493,"correct":22},"耗热量大的建筑物",{"key":24,"text":495,"correct":22},"间歇使用的房间",{"key":28,"text":497,"correct":22},"有防火防爆要求的车间",{"key":31,"text":499,"correct":26},"对洁净度有特殊要求的实验室",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":135,"analysis":34},902348,"采暖系统的热网中，辐射管网的特点有（ ）。",[504,506,508,510],{"key":20,"text":505,"correct":22},"控制方便，可实现分片供热",{"key":24,"text":507,"correct":22},"投资和金属耗量大",{"key":28,"text":509,"correct":22},"适用厂房密集的小型工厂",{"key":31,"text":511,"correct":26},"运行管理复杂，要求较高自动控制措施",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":148,"analysis":34},902350,"低区直接给水高区设储水池、水泵、水箱的给水方式的特点为（ ）。",[516,518,520,522],{"key":20,"text":517,"correct":26},"安装维护简单",{"key":24,"text":519,"correct":22},"能量消耗较小",{"key":28,"text":521,"correct":22},"可延时供水",{"key":31,"text":523,"correct":26},"投资较小",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":97,"analysis":34},902351,"分户热计量采暖系统中，水平单管系统的布置形式有（ ）。",[528,530,532,534],{"key":20,"text":529,"correct":22},"顺流式",{"key":24,"text":531,"correct":22},"同侧接管跨越式",{"key":28,"text":533,"correct":26},"逆流式",{"key":31,"text":535,"correct":22},"异侧接管跨越式",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":20,"analysis":34},902352,"根据液态液化石油气管道设计压力分级规定，次高压燃气管道A级管道的压力分级应为（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":22},"0.8MPa≤p≤1.6MPa",{"key":24,"text":543,"correct":26},"1.6MPa≤P≤4.0MPa",{"key":28,"text":545,"correct":26},"p>4.0MPa",{"key":31,"text":547,"correct":26},"P≤4.0MPa",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":47,"analysis":34},902353,"供水较可靠，系统简单，投资省，安装、维护简单，可以充分利用外网水压，节省能量的给水方式是（ ）。",[552,554,556,558],{"key":20,"text":553,"correct":22},"单设水箱供水方式",{"key":24,"text":555,"correct":26},"设贮水池、水泵的给水方式",{"key":28,"text":557,"correct":22},"直接给水方式",{"key":31,"text":559,"correct":26},"低区直接给水，高区设贮水池、水泵、水箱的供水方式",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":47,"analysis":34},902354,"燃气工程管道系统安装完毕后，应对管道进行吹扫，吹扫时应满足的条件有（ ）。",[564,565,567,568],{"key":20,"text":418,"correct":22},{"key":24,"text":566,"correct":26},"吹扫流速不宜低于10m\u002Fs",{"key":28,"text":422,"correct":22},{"key":31,"text":424,"correct":26},{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":33,"analysis":34},902355,"燃气输配系统是一个综合设施，其组成除包括燃气输配管网、储配站外，还有（ ）。",[573,575,577,579],{"key":20,"text":574,"correct":22},"调压计量站",{"key":24,"text":576,"correct":26},"恒流计量站",{"key":28,"text":578,"correct":22},"运行监控系统",{"key":31,"text":580,"correct":22},"数据采集系统",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":47,"analysis":34},902356,"热风采暖系统的特点包括（ ）。",[585,587,589,591],{"key":20,"text":586,"correct":22},"热惰性小",{"key":24,"text":588,"correct":26},"设备较复杂",{"key":28,"text":590,"correct":22},"适用于耗热量大的建筑",{"key":31,"text":592,"correct":26},"不适用于间歇使用的房间",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":135,"analysis":34},902357,"热水供应管道上应安装止回阀的位置有（ ）。",[597,599,601,603],{"key":20,"text":598,"correct":22},"开式加热水箱与其补给水箱的连通管上",{"key":24,"text":600,"correct":22},"热水供应管网的回水管上",{"key":28,"text":602,"correct":22},"循环水泵的出水管上",{"key":31,"text":604,"correct":26},"循环水泵的回水管上",{"id":606,"libraryId":5,"type":15,"typeLabel":16,"stem":607,"options":608,"answer":97,"analysis":34},902358,"室内排水系统的通气管，常用的形式为（ ）。",[609,611,613,615],{"key":20,"text":610,"correct":22},"器具通气管",{"key":24,"text":612,"correct":22},"安全通气管",{"key":28,"text":614,"correct":26},"调节通气管",{"key":31,"text":616,"correct":22},"结合通气管",[618,622,625,628,631,634],{"id":619,"name":620,"category":7,"favorite":621},1,"领导干部任职前廉政法规知识测试题",92,{"id":623,"name":624,"category":7,"favorite":619},595,"建筑结构与设备",{"id":626,"name":627,"category":7,"favorite":619},715,"招标采购专业知识与法律法规",{"id":629,"name":630,"category":7,"favorite":619},848,"市政方向-通用基础",{"id":632,"name":633,"category":7,"favorite":8},534,"BIM工程师",{"id":635,"name":633,"category":7,"favorite":8},535]