[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-583-35":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":626},{"id":5,"name":6,"category":7,"favorite":8},583,"建设工程技术与计量（安装)","建筑工程",0,35,50,2472,[13,35,48,61,74,86,99,112,124,135,147,159,171,183,196,209,221,233,245,258,270,282,294,306,318,330,342,351,363,375,387,399,411,423,435,447,459,471,483,495,507,519,531,543,555,567,579,591,603,615],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},901889,2,"多选题","(2012年)火灾通常划分为 A、 B、 C、D四大类，属于B类火灾的有()。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","木材、纸类等火灾",false,{"key":24,"text":25,"correct":26},"B","可燃性液体火灾",true,{"key":28,"text":29,"correct":22},"C","活性金属火灾",{"key":31,"text":32,"correct":26},"D","可燃性气体火灾","BD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},901890,"(2013年)根据水灭火系统工程量计算规则，末端试水装置的安装应包括()。",[39,41,43,45],{"key":20,"text":40,"correct":26},"压力表安装",{"key":24,"text":42,"correct":26},"控制阀等附件安装",{"key":28,"text":44,"correct":22},"连接管安装",{"key":31,"text":46,"correct":22},"排水管安装","AB",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},901891,"(2014年)依据《通用安装工程工程量计算规范》(GB50856-2013)的规定，水灭火系统报警装置按型号、规格以“组”计算，以下选项属于湿式报警装置安装工程量内的有()。",[52,54,56,58],{"key":20,"text":53,"correct":26},"压力表及压力开关",{"key":24,"text":55,"correct":26},"试验阀及报警阀",{"key":28,"text":57,"correct":22},"法兰及孔板",{"key":31,"text":59,"correct":26},"过滤器及延时器","ABD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},901892,"(2014年)依据《通用安装工程工程量计算规范》(GB50856-2013)的规定，自动报警系统调试按“系统”计算。其报警系统包括探测器、报警器、消防广播及()。",[65,67,69,71],{"key":20,"text":66,"correct":26},"报警控制器",{"key":24,"text":68,"correct":22},"防火控制阀",{"key":28,"text":70,"correct":26},"报警按钮",{"key":31,"text":72,"correct":26},"消防电话","ACD",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":60,"analysis":34},901893,"(2015年)喷水灭火系统中，自动喷水预作用系统的特点有( )。",[78,80,82,84],{"key":20,"text":79,"correct":26},"具有湿式系统和干式系统的特点",{"key":24,"text":81,"correct":26},"火灾发生时作用时间快、不延迟",{"key":28,"text":83,"correct":22},"系统组成较简单，无需充气设备",{"key":31,"text":85,"correct":26},"适用于不允许有水渍损失的场所",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},901894,"(2016年)下列自动喷水灭火系统中，采用闭式喷头的有()。",[90,92,94,96],{"key":20,"text":91,"correct":26},"自动喷水湿式灭火系统",{"key":24,"text":93,"correct":22},"自动喷水干湿两用灭火系统",{"key":28,"text":95,"correct":22},"自动喷水雨淋灭火系统",{"key":31,"text":97,"correct":26},"自动喷水预作用灭火系统","AD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":111,"analysis":34},901895,"(2016年)依据《通用安装工程工程量计算规范》GB50856-2013的规定，消防工程工程量计量时，下列装置按“组”计算的有()。",[103,105,107,109],{"key":20,"text":104,"correct":22},"消防水炮",{"key":24,"text":106,"correct":26},"报警装置",{"key":28,"text":108,"correct":26},"末端试水装置",{"key":31,"text":110,"correct":26},"温感式水幕装置","BCD",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":47,"analysis":34},901896,"(2017年)下列有关消防水泵接合器设置，说法正确的有()。",[116,118,120,122],{"key":20,"text":117,"correct":26},"高层民用建筑室内消火栓给水系统应设水泵接合器",{"key":24,"text":119,"correct":26},"消防给水竖向分区供水时，在消防车供水压力范围内的分区，应分别设置水泵接合器",{"key":28,"text":121,"correct":22},"超过2层或建筑面积大于1000㎡的地下建筑应设水泵接合器",{"key":31,"text":123,"correct":22},"高层工业建筑和超过三层的多层工业建筑应设水泵结合器",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":111,"analysis":34},901897,"(2013年)某建筑需设计自动喷水灭火系统，考虑到冬季系统环境温度经常性低，建筑可以采用的系统有()。",[128,129,131,133],{"key":20,"text":91,"correct":22},{"key":24,"text":130,"correct":26},"自动喷水预作用系统",{"key":28,"text":132,"correct":26},"自动喷水雨淋系统",{"key":31,"text":134,"correct":26},"自动喷水干湿两用灭火",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":60,"analysis":34},901898,"(2015年)依据《通用安装工程工程量计算规范》(GB 50856—2013)，防火控制装置调试项目中计量单位以“个”计量的有( )。",[139,141,143,145],{"key":20,"text":140,"correct":26},"电动防火门调试",{"key":24,"text":142,"correct":26},"防火卷帘门调试",{"key":28,"text":144,"correct":22},"瓶头阀调试",{"key":31,"text":146,"correct":26},"正压送风阀调试",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":98,"analysis":34},901899,"(2017年)关于固定消防炮灭火系统的设置，下列说法正确的有()。",[151,153,155,157],{"key":20,"text":152,"correct":26},"有爆炸危险性的场所，宜选用远控炮系统",{"key":24,"text":154,"correct":22},"当灭火对象高度较高时，不宜设置消防炮塔",{"key":28,"text":156,"correct":22},"室外消防炮应设置在被保护场所常年主导风向的下风方向",{"key":31,"text":158,"correct":26},"室内消防炮的布置数量不应少于两门",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":47,"analysis":34},901900,"(2018年)下列关于水灭火系统中设置消防水池的规定，表述正确的是（ ）。",[163,165,167,169],{"key":20,"text":164,"correct":26},"当生产、生活用水量达到最大，市政给水管网不能满足室内、外消防给水设计流量时",{"key":24,"text":166,"correct":26},"当只有一条入户引入管，且室外消火栓设计流量大于20L\u002Fs",{"key":28,"text":168,"correct":22},"当采用一路消防供水，建筑物高于80m 时",{"key":31,"text":170,"correct":22},"当采用两路消防供水时，消防水池的有效容积不应小于40m3",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":47,"analysis":34},901901,"(2018年)根据金属油罐的不同结构，选用不同的施工方法，以下各类油罐可选择“抱杆倒装法”施工的有（ ）。",[175,177,179,181],{"key":20,"text":176,"correct":26},"拱顶油罐600m3",{"key":24,"text":178,"correct":26},"无力矩顶油罐700m3",{"key":28,"text":180,"correct":22},"内浮顶油罐1000m3",{"key":31,"text":182,"correct":22},"浮顶油罐3500m3",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":195,"analysis":34},901902,"(2018年)依据《通用安装工程工程量计算规范》（GB 50856－2013），消防工程水灭火系统安装工程量中，以“组”为单位计量的包括（ ）。",[187,189,191,193],{"key":20,"text":188,"correct":26},"湿式报警装置安装",{"key":24,"text":190,"correct":22},"装置压力表安装",{"key":28,"text":192,"correct":26},"末端试水装置安装",{"key":31,"text":194,"correct":22},"试验管流量计安装","AC",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":208,"analysis":34},901905,"(2010年)电气工程穿管配线中，下列所述情况可以穿入同一管子的有()。",[200,202,204,206],{"key":20,"text":201,"correct":26},"同一设备的电动机回路和无抗干扰要求的控制回路",{"key":24,"text":203,"correct":26},"照明花灯的所有回路",{"key":28,"text":205,"correct":26},"同一交流回路的导线",{"key":31,"text":207,"correct":22},"电压为110V以下的回路","ABC",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":60,"analysis":34},901906,"(2012年)与电磁式时间继电器相比，电动式时间继电器的主要特点有()。",[213,215,217,219],{"key":20,"text":214,"correct":26},"延时精确度较高",{"key":24,"text":216,"correct":26},"延时时间调整范围较大",{"key":28,"text":218,"correct":22},"体积和重量较大",{"key":31,"text":220,"correct":26},"价格较高",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":73,"analysis":34},901907,"(2012年)发光二极管(LE D)是电致发光的固体半导体高亮度点光源，其特点有()。",[225,227,229,231],{"key":20,"text":226,"correct":26},"使用寿命长",{"key":24,"text":228,"correct":22},"显色指数高",{"key":28,"text":230,"correct":26},"无紫外和红外辐射",{"key":31,"text":232,"correct":26},"能在低电压下工作",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":208,"analysis":34},901908,"(2013年)用电流继电器作为电动机保护和控制时，其主要的技术要求包括()。",[237,239,241,243],{"key":20,"text":238,"correct":26},"继电器安装时，需将线圈串联到主回路中",{"key":24,"text":240,"correct":26},"继电器常闭触头接于控制电路中与解除器连接",{"key":28,"text":242,"correct":26},"继电器线圈的额定电流应大于或等于电动机额定电流",{"key":31,"text":244,"correct":22},"继电器的动作电流一般应为电动机额定电流的2倍",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":257,"analysis":34},901909,"(2015年)当电动机容量较大时，为降低启动电流，常用的减压启动方法有( )。",[249,251,253,255],{"key":20,"text":250,"correct":22},"绕线转子同步电动机启动法",{"key":24,"text":252,"correct":26},"绕线转子异步电动机启动法",{"key":28,"text":254,"correct":26},"软启动器启动法",{"key":31,"text":256,"correct":22},"感应减压启动法","BC",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":98,"analysis":34},901910,"(2016年)依据《通用安装工程工程量计算规范》CB50856-2013的规定，电气照明工程中按设计图示数量以“套”为计量单位的有()。",[262,264,266,268],{"key":20,"text":263,"correct":26},"荧光灯",{"key":24,"text":265,"correct":22},"接线箱",{"key":28,"text":267,"correct":22},"桥架",{"key":31,"text":269,"correct":26},"高度标志（障碍）灯",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":47,"analysis":34},901911,"(2016年)电机控制和保护设备安装中，应符合的要求有()。",[274,276,278,280],{"key":20,"text":275,"correct":26},"每台电机均应安装控制和保护设备",{"key":24,"text":277,"correct":26},"电机控制和保护设备一般设在电机附近",{"key":28,"text":279,"correct":22},"采用熔丝的过程和短路保护装置保护整定值一般为电机额定电流的1.1-1.25倍",{"key":31,"text":281,"correct":22},"采用热元件的过流和短路保护装置保护整定值一般为电机额定电流的1.5-2.5倍",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":33,"analysis":34},901912,"(2017年)电动机减压启动中，软启动器除了完全能够满足电动机平稳启动这一基本要求外，还具备的特点有()。",[286,288,290,292],{"key":20,"text":287,"correct":22},"参数设置复杂",{"key":24,"text":289,"correct":26},"可靠性高",{"key":28,"text":291,"correct":22},"故障查找较复杂",{"key":31,"text":293,"correct":26},"维护量小",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":208,"analysis":34},901913,"(2012年)在电气照明配管配线工程中，适用于暗配的管道有()。",[298,300,302,304],{"key":20,"text":299,"correct":26},"焊接钢管",{"key":24,"text":301,"correct":26},"硬塑料管",{"key":28,"text":303,"correct":26},"半硬塑料管",{"key":31,"text":305,"correct":22},"金属软管",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":208,"analysis":34},901914,"(2014年)电线管连接时，禁止采用的连接方式为()。",[310,312,314,316],{"key":20,"text":311,"correct":26},"电焊连接",{"key":24,"text":313,"correct":26},"气焊连接",{"key":28,"text":315,"correct":26},"对焊连接",{"key":31,"text":317,"correct":22},"丝扣连接",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":47,"analysis":34},901915,"(2017年)继电器具有自动控制和保护系统的功能，下列继电器中主要用于电气保护的有()。",[322,324,326,328],{"key":20,"text":323,"correct":26},"热继电器",{"key":24,"text":325,"correct":26},"电压继电器",{"key":28,"text":327,"correct":22},"中间继电器",{"key":31,"text":329,"correct":22},"时间继电器",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":111,"analysis":34},901916,"(2018年)按《1kV 及以下配线工程施工与验收规范》（GB 50575－2010）的规定，下列电气配管钢导管敷设连接符合要求的有（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":22},"暗配钢导管与盒（箱）连接可采用焊接",{"key":24,"text":337,"correct":26},"明配钢导管与盒（箱）连接可采用螺纹连接",{"key":28,"text":339,"correct":26},"可将钢导管敷设到设备接线盒内，实现与用电设备直接连接",{"key":31,"text":341,"correct":26},"钢导管宜经柔性导管过渡与用电设备接线盒间接连接",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":350,"analysis":34},901917,"(2018年)继电器可用于自动控制和保护系统，以下具有保护功能的继电器有（ ）。",[346,347,348,349],{"key":20,"text":329,"correct":22},{"key":24,"text":327,"correct":22},{"key":28,"text":323,"correct":26},{"key":31,"text":325,"correct":26},"CD",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":73,"analysis":34},901920,"(2014年)球罐水压试验过程中要进行基础沉降观测，并做好实测记录。正确的观测时点为()。",[355,357,359,361],{"key":20,"text":356,"correct":26},"充水前",{"key":24,"text":358,"correct":22},"充水到1\u002F2球罐本体高度",{"key":28,"text":360,"correct":26},"充满水24h",{"key":31,"text":362,"correct":26},"放水后",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":60,"analysis":34},901921,"(2013年)为了充分发挥填料塔的传质效能，填料应符合的要求有()。",[367,369,371,373],{"key":20,"text":368,"correct":26},"较大的比表面积",{"key":24,"text":370,"correct":26},"良好的湿润性能",{"key":28,"text":372,"correct":22},"气液通过能力小",{"key":31,"text":374,"correct":26},"较高的空隙率",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":257,"analysis":34},901922,"(2013年)室内排水管道上需要设置双向清通的检查口，设置要求为()。",[379,381,383,385],{"key":20,"text":380,"correct":22},"立管上检查口之间的距离不大于12m",{"key":24,"text":382,"correct":26},"最底层和设有卫生器具的二层以上破屋顶建筑物的最高层排水立管上应设置检查口",{"key":28,"text":384,"correct":26},"排水立管上如有乙字管，则应在乙字管的上部设置检查口",{"key":31,"text":386,"correct":22},"平顶建筑通气管顶口旁设检查口",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":60,"analysis":34},901923,"(2013年)与铸铁散热器相比，钢制散热器的性能特点有()。",[391,393,395,397],{"key":20,"text":392,"correct":26},"适用于高层建筑和高温水供暖系统",{"key":24,"text":394,"correct":26},"耐压强度高，但不适用于蒸汽供暖系统",{"key":28,"text":396,"correct":22},"使用寿命长，热稳定性好",{"key":31,"text":398,"correct":26},"不适用于具有腐蚀气体或相对湿度较大的场合",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":60,"analysis":34},901924,"(2014年)采暖工程中，分户热计量采暖系统除包括分户水平单管系统外，还有()。",[403,405,407,409],{"key":20,"text":404,"correct":26},"分户水平双管系统",{"key":24,"text":406,"correct":26},"分户水平单双管系统",{"key":28,"text":408,"correct":22},"分户水平环状管网系统",{"key":31,"text":410,"correct":26},"分户水平放射式系统",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":98,"analysis":34},901925,"(2017年)根据《通用安装工程工程量计算规范》(GB50856-2013)，给排水、采暖管道室内外界限划分正确的有()。",[415,417,419,421],{"key":20,"text":416,"correct":26},"给水管以建筑物外墙皮1.5m为界，入口处设阀门者以阀门为界",{"key":24,"text":418,"correct":22},"排水管以建筑物外墙皮3m为界，有化粪池时以化粪池为界",{"key":28,"text":420,"correct":22},"采暖管地下引入室内以室内第一个阀门为界，地上引入室内以墙外三通为界",{"key":31,"text":422,"correct":26},"采暖管以建筑物外墙皮1.5m为界，入口处设阀门者以阀门为界",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":350,"analysis":34},901926,"(2013年)室内燃气中压管道，选用无缝钢管，其连接方式应为()。",[427,429,431,433],{"key":20,"text":428,"correct":22},"螺纹连接",{"key":24,"text":430,"correct":22},"卡箍连接",{"key":28,"text":432,"correct":26},"焊接",{"key":31,"text":434,"correct":26},"法兰连接",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":73,"analysis":34},901927,"(2014年)燃气输配系统是一个综合设施，其组成除包括燃气输配管网、储配站外，还有()。",[439,441,443,445],{"key":20,"text":440,"correct":26},"调压计量站",{"key":24,"text":442,"correct":22},"恒流计量站",{"key":28,"text":444,"correct":26},"运行监控系统",{"key":31,"text":446,"correct":26},"数据采集系统",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":73,"analysis":34},901928,"(2016年)采暖工程中，分户热计量分室温度控制系统装置包括()。",[451,453,455,457],{"key":20,"text":452,"correct":26},"锁闭阀",{"key":24,"text":454,"correct":22},"平衡网",{"key":28,"text":456,"correct":26},"散热器温控阀",{"key":31,"text":458,"correct":26},"热量分配表",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":111,"analysis":34},901929,"(2017年)敷设在高层建筑室内的塑料排水管管径大于或等于110mm时，应设阻火圈的位置有()。",[463,465,467,469],{"key":20,"text":464,"correct":22},"暗敷立管穿越楼层的贯穿部位",{"key":24,"text":466,"correct":26},"明敷立管穿越楼层的贯穿部位",{"key":28,"text":468,"correct":26},"横管穿越防火分区的隔墙和防火墙的两侧",{"key":31,"text":470,"correct":26},"横管穿越管道井井壁或管窿围护墙体的贯穿部位外侧",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":208,"analysis":34},901930,"(2018年)以下关于热水采暖系统形式特点的描述，正确的有（ ）。",[475,477,479,481],{"key":20,"text":476,"correct":26},"重力循环单管上供下回式升温慢，压力易平衡",{"key":24,"text":478,"correct":26},"重力循环双管上供下回式散热器并联，可单独调节",{"key":28,"text":480,"correct":26},"机械循环水平串联单管式构造简单、环路少、经济性最好",{"key":31,"text":482,"correct":22},"机械循环双管中供式排气方便，对楼层、扩建有利",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":98,"analysis":34},901931,"(2018年)高级民用建筑的室内给水系统安装，De≤63mm 的热水管，宜选用的管材有（ ）。",[487,489,491,493],{"key":20,"text":488,"correct":26},"给水聚丙烯管",{"key":24,"text":490,"correct":22},"给水硬聚氯乙烯管",{"key":28,"text":492,"correct":22},"给水聚乙烯管",{"key":31,"text":494,"correct":26},"给水衬塑铝合金管",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":20,"analysis":34},901932,"(2016年)对建筑高度低于100m的居民建筑，靠外墙的防烟楼梯间及其前室、消防电梯间前室和合用前室，宜采用的排烟方式为()。",[499,501,503,505],{"key":20,"text":500,"correct":26},"自然排烟",{"key":24,"text":502,"correct":22},"机械排烟",{"key":28,"text":504,"correct":22},"加压排烟",{"key":31,"text":506,"correct":22},"抽吸排烟",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":47,"analysis":34},901933,"(2016年)高中效过滤器作为净化空调系统的中间过滤器，其材料应为()。",[511,513,515,517],{"key":20,"text":512,"correct":26},"无纺布",{"key":24,"text":514,"correct":26},"丙纶滤布",{"key":28,"text":516,"correct":22},"丙纶纤维滤纸",{"key":31,"text":518,"correct":22},"玻璃纤维滤纸",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":208,"analysis":34},901934,"(2017年)混合式气力输送系统的特点有()。",[523,525,527,529],{"key":20,"text":524,"correct":26},"可多点吸料",{"key":24,"text":526,"correct":26},"可多点卸料",{"key":28,"text":528,"correct":26},"输送距离长",{"key":31,"text":530,"correct":22},"风机工作条件好",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":195,"analysis":34},901935,"(2017年)依据《通用安装工程工程量计算规范》(GB50856-2013)的规定，通风空调工程中过滤器的计量方式有()。",[535,537,539,541],{"key":20,"text":536,"correct":26},"以台计量，按设计图示数量计算",{"key":24,"text":538,"correct":22},"以个计量，按设计图示数量计算",{"key":28,"text":540,"correct":26},"以面积计量，按设计图示尺寸的过滤面积计算",{"key":31,"text":542,"correct":22},"以面积计量，按设计图示尺寸计算",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":350,"analysis":34},901936,"(2013年)全面通风系统中，单向流通风的特点有()。",[547,549,551,553],{"key":20,"text":548,"correct":22},"温度控制较好",{"key":24,"text":550,"correct":22},"对送风的空气分布器要求较高",{"key":28,"text":552,"correct":26},"通风量小",{"key":31,"text":554,"correct":26},"气流控制效果好",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":208,"analysis":34},901937,"(2013年)空调系统中，喷水室除了具有消耗金属少，容易加工的优点外，还具有的优点有()。",[559,561,563,565],{"key":20,"text":560,"correct":26},"空气加湿和减湿功能",{"key":24,"text":562,"correct":26},"对空气能进行加热和冷却",{"key":28,"text":564,"correct":26},"空气净化功能",{"key":31,"text":566,"correct":22},"占地面积较小，消耗小",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":73,"analysis":34},901938,"(2014年)空调中的消声器是由吸声材料按不同的消声原理设计成的构件，它包括多种形式，除复合型外，还有()。",[571,573,575,577],{"key":20,"text":572,"correct":26},"共振型",{"key":24,"text":574,"correct":22},"冲激式",{"key":28,"text":576,"correct":26},"抗性",{"key":31,"text":578,"correct":26},"阻性",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":33,"analysis":34},901939,"(2016年)通风工程中，当排出的风是潮湿空气时，风管制作材料宜采用()。",[583,585,587,589],{"key":20,"text":584,"correct":22},"钢板",{"key":24,"text":586,"correct":26},"玻璃钢板",{"key":28,"text":588,"correct":22},"铝板",{"key":31,"text":590,"correct":26},"聚氯乙烯板",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":73,"analysis":34},901940,"(2016年)空调系统由空气处理、空气输配、冷热源和自控系统等组成，下列选项属于空气处理部分的设备有()。",[595,597,599,601],{"key":20,"text":596,"correct":26},"过滤器",{"key":24,"text":598,"correct":22},"消声器",{"key":28,"text":600,"correct":26},"加热器",{"key":31,"text":602,"correct":26},"喷水室",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":111,"analysis":34},901941,"(2017年)风阀是空气输配管网的控制、调节机构，只具有控制功能的风阀为()。",[607,609,611,613],{"key":20,"text":608,"correct":22},"插板阀",{"key":24,"text":610,"correct":26},"止回阀",{"key":28,"text":612,"correct":26},"防火阀",{"key":31,"text":614,"correct":26},"排烟阀",{"id":616,"libraryId":5,"type":15,"typeLabel":16,"stem":617,"options":618,"answer":195,"analysis":34},901942,"(2018年)空调系统冷凝水管道宜采用的管材为（ ）。",[619,621,623,625],{"key":20,"text":620,"correct":26},"聚氯乙烯塑料管",{"key":24,"text":622,"correct":22},"橡胶管",{"key":28,"text":624,"correct":26},"热镀锌钢管",{"key":31,"text":299,"correct":22},[627,631,634,637,640,643],{"id":628,"name":629,"category":7,"favorite":630},1,"领导干部任职前廉政法规知识测试题",92,{"id":632,"name":633,"category":7,"favorite":628},595,"建筑结构与设备",{"id":635,"name":636,"category":7,"favorite":628},715,"招标采购专业知识与法律法规",{"id":638,"name":639,"category":7,"favorite":628},848,"市政方向-通用基础",{"id":641,"name":642,"category":7,"favorite":8},534,"BIM工程师",{"id":644,"name":642,"category":7,"favorite":8},535]