[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-583-25":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":597},{"id":5,"name":6,"category":7,"favorite":8},583,"建设工程技术与计量（安装)","建筑工程",0,25,50,2472,[13,31,43,55,67,79,91,103,115,127,139,149,161,173,185,197,209,221,232,244,256,268,280,292,303,315,327,339,347,359,369,381,389,401,413,425,437,449,461,473,482,494,506,518,527,539,551,561,573,585],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":30},901363,1,"单选题","母线水平布置安装时，排列在最外边的母线应为()相序。",[19,22,24,26],{"key":20,"text":20,"correct":21},"A",false,{"key":23,"text":23,"correct":21},"B",{"key":25,"text":25,"correct":21},"C",{"key":27,"text":28,"correct":29},"D","N",true,"",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":25,"analysis":30},901364,"低压动力配电箱的主要功能是()。",[35,37,39,41],{"key":20,"text":36,"correct":21},"只对动力设备配电",{"key":23,"text":38,"correct":21},"只对照明设备配电",{"key":25,"text":40,"correct":29},"不仅对动力设备配电，也可兼向照明设备配电",{"key":27,"text":42,"correct":21},"给小容量的单相动力设备配电",{"id":44,"libraryId":5,"type":15,"typeLabel":16,"stem":45,"options":46,"answer":27,"analysis":30},901365,"适用于需频繁操作及有易燃易爆危险的场所，要求加工精度高，对其密封性能要求更严的高压断路器是()。",[47,49,51,53],{"key":20,"text":48,"correct":21},"多油断路器",{"key":23,"text":50,"correct":21},"少油断路器",{"key":25,"text":52,"correct":21},"高压真空断路器",{"key":27,"text":54,"correct":29},"六氟化硫断路器",{"id":56,"libraryId":5,"type":15,"typeLabel":16,"stem":57,"options":58,"answer":27,"analysis":30},901366,"电缆安装工程施工时，下列做法中，错误的为()。",[59,61,63,65],{"key":20,"text":60,"correct":21},"直埋电缆做波浪形敷设",{"key":23,"text":62,"correct":21},"在三相四线制系统中采用四芯电力电缆",{"key":25,"text":64,"correct":21},"并联运行电缆具备相同的型号、规格及长度",{"key":27,"text":66,"correct":29},"裸钢带铠装电缆进行直接埋地敷设",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":23,"analysis":30},901367,"敞开装设备在金属框架上，保护和操作方案较多，装设地点灵活的低压断路器为()。",[71,73,75,77],{"key":20,"text":72,"correct":21},"SF6低压断路器",{"key":23,"text":74,"correct":29},"万能式低压断路器",{"key":25,"text":76,"correct":21},"塑壳式低压断路器",{"key":27,"text":78,"correct":21},"固定式低压断路器",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":23,"analysis":30},901368,"变压器柱上安装时，变压器台的安装高度应距离地面()。",[83,85,87,89],{"key":20,"text":84,"correct":21},"2m以上",{"key":23,"text":86,"correct":29},"2．5m以上",{"key":25,"text":88,"correct":21},"3m以上",{"key":27,"text":90,"correct":21},"5m以上",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":27,"analysis":30},901369,"根据《通用安装工程工程量计算规范》GB50856-2013的规定，单独安装的铁壳开关、自动开关、箱式电阻器、交阻器的外部进出线预留长度应从（ ）。",[95,97,99,101],{"key":20,"text":96,"correct":21},"安装对象最远端子接口算起",{"key":23,"text":98,"correct":21},"安装对象最近端子接口算起",{"key":25,"text":100,"correct":21},"安装对象下端往上2\u002F3处算起",{"key":27,"text":102,"correct":29},"安装对象中心算起",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":23,"analysis":30},901370,"市区或居民区的架空线尽量用（ ）。",[107,109,111,113],{"key":20,"text":108,"correct":21},"铝线",{"key":23,"text":110,"correct":29},"绝缘线",{"key":25,"text":112,"correct":21},"裸线",{"key":27,"text":114,"correct":21},"铜线",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":27,"analysis":30},901371,"封闭式母线配线，作水平敷设时，离地距离不得小于（ ）m。",[119,121,123,125],{"key":20,"text":120,"correct":21},"1",{"key":23,"text":122,"correct":21},"1.8",{"key":25,"text":124,"correct":21},"2",{"key":27,"text":126,"correct":29},"2.2",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":27,"analysis":30},901372,"高压负荷开关不能断开（ ）。",[131,133,135,137],{"key":20,"text":132,"correct":21},"工作电流",{"key":23,"text":134,"correct":21},"负荷电流",{"key":25,"text":136,"correct":21},"过负荷电流",{"key":27,"text":138,"correct":29},"短路电流",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":27,"analysis":30},901373,"下列断路器中，在35kV配电系统及以下电压等级中处于主导地位的是（ ）。",[143,145,147,148],{"key":20,"text":144,"correct":21},"油断路器",{"key":23,"text":146,"correct":21},"空气断路器",{"key":25,"text":54,"correct":21},{"key":27,"text":52,"correct":29},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":23,"analysis":30},901374,"为了保护高压电线和高压电气设备的安全，高压断路器的作用是（ ）。",[153,155,157,159],{"key":20,"text":154,"correct":21},"快速切断电源",{"key":23,"text":156,"correct":29},"通断正常负荷电流",{"key":25,"text":158,"correct":21},"防止短路故障",{"key":27,"text":160,"correct":21},"减少损失",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":23,"analysis":30},901375,"建筑物及高层建筑物变电所的变压器一律采用（ ）。",[165,167,169,171],{"key":20,"text":166,"correct":21},"油浸式变压器",{"key":23,"text":168,"correct":29},"干式变压器",{"key":25,"text":170,"correct":21},"单相变压器",{"key":27,"text":172,"correct":21},"整流变压器",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":27,"analysis":30},901376,"电缆在室外可以直接埋地敷设，经过农田的电缆埋设深度不应小于（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":21},"0.4m",{"key":23,"text":180,"correct":21},"0.5m",{"key":25,"text":182,"correct":21},"0.8m",{"key":27,"text":184,"correct":29},"1.0m",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":27,"analysis":30},901377,"防雷接地系统户外接地母线大部分采用扁钢埋地敷设，其连接应采用的焊接方式为（ ）。",[189,191,193,195],{"key":20,"text":190,"correct":21},"端接焊",{"key":23,"text":192,"correct":21},"对接焊",{"key":25,"text":194,"correct":21},"角接焊",{"key":27,"text":196,"correct":29},"搭接焊",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":25,"analysis":30},901378,"变配电工程中，硬母线的连接方式应为（ ）。",[201,203,205,207],{"key":20,"text":202,"correct":21},"扭纹链接",{"key":23,"text":204,"correct":21},"咬口连接",{"key":25,"text":206,"correct":29},"螺栓连接",{"key":27,"text":208,"correct":21},"铆接链接",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":23,"analysis":30},901379,"10kV及以下变配电室经常设有高压负荷开关，其特点为（ ）。",[213,215,217,219],{"key":20,"text":214,"correct":21},"能够断开短路电流",{"key":23,"text":216,"correct":29},"能够切断工作电流",{"key":25,"text":218,"correct":21},"没有明显的断开间隙",{"key":27,"text":220,"correct":21},"没有灭弧装置",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":25,"analysis":30},901381,"不能切断短路电流的开关设备有（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":21},"隔离开关",{"key":23,"text":228,"correct":21},"接地开关",{"key":25,"text":230,"correct":29},"负荷开关",{"key":27,"text":50,"correct":21},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":27,"analysis":30},901383,"基于测量系统中的弹簧管在被测介质的压力作用下，迫使弹簧管之末端产生相应的弹性变形位移，借助拉杆经齿轮传动机构的传动并予放大，由固定齿轮上的指示(连同触头)逐将被测值在度盘上指示出来的压力表是( )。",[236,238,240,242],{"key":20,"text":237,"correct":21},"隔膜式压力表",{"key":23,"text":239,"correct":21},"压力传感器",{"key":25,"text":241,"correct":21},"远传压力表",{"key":27,"text":243,"correct":29},"电接点压力表",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":20,"analysis":30},901384,"常用于低温区的温度监测器，测量精度高、性能稳定，不仅广泛应用于工业测温，而且被制成标准的基准仪为()。",[248,250,252,254],{"key":20,"text":249,"correct":29},"热电阻温度计",{"key":23,"text":251,"correct":21},"热电偶温度计",{"key":25,"text":253,"correct":21},"双金属温度计",{"key":27,"text":255,"correct":21},"辐射式温度计",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":23,"analysis":30},901385,"自动控制系统中，控制输入信号与主反馈信号之差称为()。",[260,262,264,266],{"key":20,"text":261,"correct":21},"输出信号",{"key":23,"text":263,"correct":29},"偏差信号",{"key":25,"text":265,"correct":21},"误差信号",{"key":27,"text":267,"correct":21},"扰动信号",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":27,"analysis":30},901386,"适用于精密的连续或间断地测量管道中液体的流量或瞬时流量，特别适用于重油、聚乙烯醇、树脂等黏度较高介质的流量测量。这种流量计为()。",[272,274,276,278],{"key":20,"text":273,"correct":21},"玻璃管转子流量计",{"key":23,"text":275,"correct":21},"电磁流量计",{"key":25,"text":277,"correct":21},"涡轮流量计",{"key":27,"text":279,"correct":29},"椭圆齿轮流量计",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":20,"analysis":30},901387,"被广泛用于实验室压力测量或现场锅炉烟、风通道各段压力及通风空调系统各段压力测量的压力表是()。",[284,286,288,290],{"key":20,"text":285,"correct":29},"液柱式压力计",{"key":23,"text":287,"correct":21},"活塞式压力计",{"key":25,"text":289,"correct":21},"弹性式压力计",{"key":27,"text":291,"correct":21},"电气式压力计",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":20,"analysis":30},901388,"常用于石油、化工、食品等生产过程中测量具有腐蚀性、高黏度、易结晶、含有固体颗粒、温度较高液体介质的压力检测仪表为()。",[296,297,299,301],{"key":20,"text":237,"correct":29},{"key":23,"text":298,"correct":21},"防爆感应式接点压力表",{"key":25,"text":300,"correct":21},"电阻远传压力表",{"key":27,"text":302,"correct":21},"电容式压力变送器",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":23,"analysis":30},901391,"依据《通用安装工程工程量计算规范》GB 50856--2013的规定，通信线路安装工程中，光缆接续的计量单位为()。",[307,309,311,313],{"key":20,"text":308,"correct":21},"段",{"key":23,"text":310,"correct":29},"头",{"key":25,"text":312,"correct":21},"芯",{"key":27,"text":314,"correct":21},"套",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":25,"analysis":30},901392,"有线电视系统一般由信号源、前端设备、干线传输系统和用户分配网络组成，前端设备不包括()。",[319,321,323,325],{"key":20,"text":320,"correct":21},"调制器",{"key":23,"text":322,"correct":21},"放大器",{"key":25,"text":324,"correct":29},"均衡器",{"key":27,"text":326,"correct":21},"滤波器",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":20,"analysis":30},901393,"集线器是对网络进行集中管理的重要工具，是各分枝的汇集点，其选用时要注意接口类型，与双绞线连接时需要的接口类型为()。",[331,333,335,337],{"key":20,"text":332,"correct":29},"RJ-45接口",{"key":23,"text":334,"correct":21},"BNC接口",{"key":25,"text":336,"correct":21},"AUI接口",{"key":27,"text":338,"correct":21},"光纤接口",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":23,"analysis":30},901394,"依据《通用安装工程工程量计算规范》GB50856-2013的规定，通信线路安装工程中，光缆接续的计量单位为（ ）。",[343,344,345,346],{"key":20,"text":308,"correct":21},{"key":23,"text":310,"correct":29},{"key":25,"text":312,"correct":21},{"key":27,"text":314,"correct":21},{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":27,"analysis":30},901395,"它是连接因特网中各局域网、广域网的设备，具有判断网络地址和选择IP路径功能，属网络层的一种互联设备。该网络设备是（ ）。",[351,353,355,357],{"key":20,"text":352,"correct":21},"网卡",{"key":23,"text":354,"correct":21},"集线器",{"key":25,"text":356,"correct":21},"交换机",{"key":27,"text":358,"correct":29},"路由器",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":23,"analysis":30},901396,"防火墙是在内部网和外部网之间、专用网与公共网之间界面上构造的保护屏障。常用的防火墙有（ ）。",[363,364,366,367],{"key":20,"text":352,"correct":21},{"key":23,"text":365,"correct":29},"包过滤路由器",{"key":25,"text":356,"correct":21},{"key":27,"text":368,"correct":21},"代理服务器",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":23,"analysis":30},901397,"光缆穿管道敷设时，若施工环境较好，一次敷设光缆的长度不超过1000m，一般采用的敷设方法为（ ）。",[373,375,377,379],{"key":20,"text":374,"correct":21},"人工牵引法敷设",{"key":23,"text":376,"correct":29},"机械牵引法敷设",{"key":25,"text":378,"correct":21},"气吹法敷设",{"key":27,"text":380,"correct":21},"顶管法敷设",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":23,"analysis":30},901398,"有判断网络地址和选择IP路径的功能，能在多网络互联环境中建立灵活的连接，可用完全不同的数据分组和介质访问方法连接各子网。属网络层的一种互联设备，该设备是（ ）。",[385,386,387,388],{"key":20,"text":354,"correct":21},{"key":23,"text":358,"correct":29},{"key":25,"text":356,"correct":21},{"key":27,"text":352,"correct":21},{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":23,"analysis":30},901399,"综合布线可采用不同类型的信息插座，支持155Mbps信息传输，适合语音、数据、视频应用，8位／8针无锁信息模板，可安装在配线架或接线盒内的信息插座模块为()。",[393,395,397,399],{"key":20,"text":394,"correct":21},"3类信息插座模式",{"key":23,"text":396,"correct":29},"5类信息插座模块",{"key":25,"text":398,"correct":21},"超5类信息插座模块",{"key":27,"text":400,"correct":21},"千兆位信息插座模块",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":23,"analysis":30},901400,"智能建筑系统中，采用计算机、网络通信和自动控制技术，对建筑物中的设备进行自动化监控管理的中央监控系统称为()。",[405,407,409,411],{"key":20,"text":406,"correct":21},"系统集成中心",{"key":23,"text":408,"correct":29},"楼宇自动化系统",{"key":25,"text":410,"correct":21},"办公自动化系统",{"key":27,"text":412,"correct":21},"安全防范系统",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":20,"analysis":30},901401,"以数据库为基础，可以把业务做成应用软件包，包内的不同应用程序之间可以互相调用或共享数据的办公自动化系统为()。",[417,419,421,423],{"key":20,"text":418,"correct":29},"事务型办公系统",{"key":23,"text":420,"correct":21},"信息管理型办公系统",{"key":25,"text":422,"correct":21},"决策支持型办公系统",{"key":27,"text":424,"correct":21},"系统科学型办公系统",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":27,"analysis":30},901402,"办公自动化的四大支柱不包括（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":21},"计算机技术",{"key":23,"text":432,"correct":21},"通信技术",{"key":25,"text":434,"correct":21},"系统科学",{"key":27,"text":436,"correct":29},"心理学",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":27,"analysis":30},901403,"安全防范系统一般由三部分组成（ ）。",[441,443,445,447],{"key":20,"text":442,"correct":21},"出人口控制系统、可视对讲系统、电视监控系统",{"key":23,"text":444,"correct":21},"防盗报警系统、可视对讲系统、电子巡更系统",{"key":25,"text":446,"correct":21},"防盗报警系统、停车场管理系统、电视监控系统",{"key":27,"text":448,"correct":29},"防盗报警系统、出入口控制系统、电视监控系统",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":30},901404,"综合布线系统中，使不同尺寸或不同类型的插头与信息插座相匹配，提供引线的重新排列，把电缆连接到应用系统的设备接口的器件是（ ）。",[453,455,457,459],{"key":20,"text":454,"correct":29},"适配器",{"key":23,"text":456,"correct":21},"接线器",{"key":25,"text":458,"correct":21},"连接模块",{"key":27,"text":460,"correct":21},"转接器",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":23,"analysis":30},901405,"信息插座在综合布线系统中起着重要作用，为所有综合布线推荐的标准信息插座是（ ）。",[465,467,469,471],{"key":20,"text":466,"correct":21},"6针模块化信息插座",{"key":23,"text":468,"correct":29},"8针模块化信息插座",{"key":25,"text":470,"correct":21},"10针模块化信息插座",{"key":27,"text":472,"correct":21},"12针模块化信息插座",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":27,"analysis":30},901406,"办公自动化系统按处理信息的功能划分为三个层次，以下选项属于第二层次的是（ ）。",[477,478,480,481],{"key":20,"text":418,"correct":21},{"key":23,"text":479,"correct":21},"综合数据库系统",{"key":25,"text":422,"correct":21},{"key":27,"text":420,"correct":29},{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":20,"analysis":30},901407,"它是火灾探测器的核心部分，作用是将火灾燃烧的特征物理量转换成电信号。该部分名称为（ ）。",[486,488,490,492],{"key":20,"text":487,"correct":29},"传感元件",{"key":23,"text":489,"correct":21},"敏感元件",{"key":25,"text":491,"correct":21},"转换器",{"key":27,"text":493,"correct":21},"控制器",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":23,"analysis":30},901408,"出人口控制系统中的门禁控制系统是一种典型的（ ）。",[498,500,502,504],{"key":20,"text":499,"correct":21},"可编程控制系统",{"key":23,"text":501,"correct":29},"集散型控制系统",{"key":25,"text":503,"correct":21},"数字直接控制系统",{"key":27,"text":505,"correct":21},"设定点控制系统",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":25,"analysis":30},901409,"不需要调制、解调，设备花费少、传输距离一般不超过2km，这种电视监控系统信号传输方式为（ ）。",[510,512,514,516],{"key":20,"text":511,"correct":21},"微波传输",{"key":23,"text":513,"correct":21},"射频传输",{"key":25,"text":515,"correct":29},"基带传输",{"key":27,"text":517,"correct":21},"宽带传输",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":27,"analysis":30},901411,"体积小、重量轻、寿命长，能频繁操作，运行维护简单，在35kV 配电系统及以下电压等级中处于主导地位的是（ ）。",[522,523,524,525],{"key":20,"text":48,"correct":21},{"key":23,"text":50,"correct":21},{"key":25,"text":54,"correct":21},{"key":27,"text":526,"correct":29},"真空断路器",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":27,"analysis":30},901412,"具有良好的非线性、动作迅速、残压低、通流容量大、无续流、结构简单、可靠性高、耐污能力强，在电站及变电所中得到广泛应用的避雷器是（ ）。",[531,533,535,537],{"key":20,"text":532,"correct":21},"保护间隙避雷器",{"key":23,"text":534,"correct":21},"管型避雷器",{"key":25,"text":536,"correct":21},"阀型避雷器",{"key":27,"text":538,"correct":29},"氧化锌避雷器",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":25,"analysis":30},901413,"用于发电厂送电、电业系统和工矿企业变电所受电、配电、实现控制、保护、检测，还可以用于频繁启动高压电动机的移开式高压开关柜是（ ）。 A.GG-1A",[543,545,547,549],{"key":20,"text":544,"correct":21},"系列开关柜",{"key":23,"text":546,"correct":21},"XGN 系列开关柜",{"key":25,"text":548,"correct":29},"KYN 系列高压开关柜",{"key":27,"text":550,"correct":21},"JYN 系列高压开关柜",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":23,"analysis":30},901414,"能带负负荷荷通、断欠电压路或，失又压能的在情短况路下、自过动跳闸，主要用作低压配电装置的主控制开关的是（ ）。",[555,556,557,559],{"key":20,"text":76,"correct":21},{"key":23,"text":74,"correct":29},{"key":25,"text":558,"correct":21},"低压熔断器",{"key":27,"text":560,"correct":21},"低压配电箱",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":23,"analysis":30},901415,"漏电保护器安装符合要求的是（ ）。",[565,567,569,571],{"key":20,"text":566,"correct":21},"照明线路的中性线不得通过漏电保护器",{"key":23,"text":568,"correct":29},"安装后应带负荷分、合开关三次，不得出现误动作",{"key":25,"text":570,"correct":21},"安装漏电保护器后应拆除单相闸刀开关或瓷插",{"key":27,"text":572,"correct":21},"电源进线必须接在漏电保护器的正下方",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":30},901416,"母线安装时，涂漆颜色黄绿红黑对应的相序分别为（ ）。",[577,579,581,583],{"key":20,"text":578,"correct":29},"ABCN",{"key":23,"text":580,"correct":21},"NBCA",{"key":25,"text":582,"correct":21},"CNAB",{"key":27,"text":584,"correct":21},"CABN",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":27,"analysis":30},901417,"可以直接对干扰信号进行测控的自动控制类型是（ ）。",[589,591,593,595],{"key":20,"text":590,"correct":21},"单回路系统",{"key":23,"text":592,"correct":21},"多回路系统",{"key":25,"text":594,"correct":21},"比值系统",{"key":27,"text":596,"correct":29},"复合系统",[598,601,604,607,610,613],{"id":15,"name":599,"category":7,"favorite":600},"领导干部任职前廉政法规知识测试题",92,{"id":602,"name":603,"category":7,"favorite":15},595,"建筑结构与设备",{"id":605,"name":606,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":608,"name":609,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":611,"name":612,"category":7,"favorite":8},534,"BIM工程师",{"id":614,"name":612,"category":7,"favorite":8},535]