[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-583-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":595},{"id":5,"name":6,"category":7,"favorite":8},583,"建设工程技术与计量（安装)","建筑工程",0,21,50,2472,[13,34,46,58,70,82,94,106,118,130,141,153,165,177,186,194,206,218,230,240,252,264,276,287,299,311,323,335,347,359,371,383,391,401,413,425,437,449,458,470,482,494,506,518,530,542,553,562,574,583],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},901161,1,"单选题","高级、高层民用建筑室内给水系统中，对于DN≤150mm的冷水管，宜采用的管材为（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","给水聚丙烯管",false,{"key":24,"text":25,"correct":22},"B","衬塑铝合金管",{"key":27,"text":28,"correct":29},"C","薄壁铜管",true,{"key":31,"text":32,"correct":22},"D","镀锌无缝钢管","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},901162,"适用于电力供应充足，电价较低的各类高层建筑中的竖向分区给水方式的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"分区水箱减压给水方式",{"key":24,"text":41,"correct":22},"分区串联给水方式",{"key":27,"text":43,"correct":22},"并联直接给水方式",{"key":31,"text":45,"correct":29},"分区减压阀减压给水方式",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},901163,"当室外给水管网水质水量水压均能满足建筑物内用水要求时，应首先考虑采用（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"单设水箱给水方式",{"key":24,"text":53,"correct":29},"直接给水方式",{"key":27,"text":55,"correct":22},"设贮水池、水泵的给水方式",{"key":31,"text":57,"correct":22},"设水泵、水箱的给水方式",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},901164,"冻土深度为0.3m的地区，城市配水管网埋地铺设于车行道下时，覆土厚度不小于（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"0.4m",{"key":24,"text":65,"correct":22},"0.5m",{"key":27,"text":67,"correct":29},"0.7m",{"key":31,"text":69,"correct":22},"1.0m",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},901165,"依据《通用安装工程工程量计算规范》GB50856-2013的规定，给排水、采暖、燃气工程计算管道工程量时，方形补偿器的长度计量方法正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":29},"以所占长度列入管道工程量内",{"key":24,"text":77,"correct":22},"以总长度列入管道工程量内",{"key":27,"text":79,"correct":22},"列入补偿器总长度的1\u002F2",{"key":31,"text":81,"correct":22},"列入补偿器总长度的2\u002F3",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},901166,"室内燃气引入管从地下引入时，管材宜采用（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"直缝电焊钢管",{"key":24,"text":89,"correct":22},"单面螺旋缝焊管",{"key":27,"text":91,"correct":22},"双面螺旋缝焊管",{"key":31,"text":93,"correct":29},"无缝钢管",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},901167,"城市燃气供应系统中，目前在中、低压两级系统使用的燃气压送设备有罗茨式鼓风机和（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"离心式鼓风机",{"key":24,"text":101,"correct":29},"往复式压送机",{"key":27,"text":103,"correct":22},"螺杆式压送机",{"key":31,"text":105,"correct":22},"滑片式压送机",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},901168,"一般设在热力管网的回水干管上，其扬程不应小于设计流量条件下热源、热网、最不利用户环路压力损失之和。此水泵为（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"补水泵",{"key":24,"text":113,"correct":22},"混水泵",{"key":27,"text":115,"correct":22},"凝结水泵",{"key":31,"text":117,"correct":29},"循环水泵",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},901169,"生活给水系统在交付使用之前必须进行冲洗和消毒，以下做法正确的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"试压合格后，利用系统内存水进行冲洗，再进行消毒",{"key":24,"text":125,"correct":29},"冲洗顺序是先室外、后室内；先地下、后地上",{"key":27,"text":127,"correct":22},"冲洗前可不拆除节流阀、报警阀、孔板和喷嘴",{"key":31,"text":129,"correct":22},"消毒用水应在管道中停留12h",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},901170,"适用于系统工作压力小于或等于0.6MPa，工作温度小于或等于70℃室内给水系统，采用热熔承插链接，与金属配管配件用螺纹连接的给水管材是（ ）。",[134,135,137,139],{"key":20,"text":21,"correct":29},{"key":24,"text":136,"correct":22},"给水聚乙烯管",{"key":27,"text":138,"correct":22},"工程塑料管",{"key":31,"text":140,"correct":22},"给水硬聚氯乙烯管",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":33},901171,"给水系统分区设置水箱和水泵、水泵分散布置，总管线较短，投资较省，能量消耗较小，但供水独立性差，上区受下区限制的给水方式是（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"分区水箱减压给水",{"key":24,"text":148,"correct":29},"分区串联给水",{"key":27,"text":150,"correct":22},"分区并联给水",{"key":31,"text":152,"correct":22},"高位水箱减压阀给水",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":20,"analysis":33},901172,"在消防系统的室内给水管网上止回阀不应装在（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":29},"消防水箱的进水管",{"key":24,"text":160,"correct":22},"消防水泵接合器的引入管",{"key":27,"text":162,"correct":22},"水泵出水管和升压给水方式的水泵旁通管",{"key":31,"text":164,"correct":22},"生产设备可能产生的水压高于室内给水管网水压的配水支管",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":24,"analysis":33},901173,"室内给水管与冷冻水管、热水管共架或同沟水平敷设时，给水管应敷设在（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"冷冻水管下面、热水管上面",{"key":24,"text":172,"correct":29},"冷冻水管上面、热水管下面",{"key":27,"text":174,"correct":22},"几种管道的最下面",{"key":31,"text":176,"correct":22},"几种管道的最上面",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":20,"analysis":33},901174,"近年来，在大型的高层民用建筑中，室内给水系统的总立管宜采用的管道为（ ）。",[181,183,184,185],{"key":20,"text":182,"correct":29},"球墨铸铁管",{"key":24,"text":93,"correct":22},{"key":27,"text":140,"correct":22},{"key":31,"text":21,"correct":22},{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":20,"analysis":33},901175,"依据《通用安装工程工程量计算规范》GB 50856-2013的规定，给排水、采暖、燃气工程计算管道工程量时，方形补偿器的长度计算方法正确的是（ ）。",[190,191,192,193],{"key":20,"text":75,"correct":29},{"key":24,"text":77,"correct":22},{"key":27,"text":79,"correct":22},{"key":31,"text":81,"correct":22},{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":24,"analysis":33},901176,"在计算管道工程的工程量时，室内外管道划分界限为（ ）。",[198,200,202,204],{"key":20,"text":199,"correct":22},"给水管道入口设阀门者以阀门为界，排水管道以建筑物外墙皮1.5m",{"key":24,"text":201,"correct":29},"给水管道以建筑物外墙皮1.5为界，排水管道以出户第一个排水检查井为界",{"key":27,"text":203,"correct":22},"采暖管道以建筑物外墙皮1.5m为界，排水管道以墙外三通为界",{"key":31,"text":205,"correct":22},"燃气管道地上引入室内第一个阀门为界，采暖管道入口设阀门者为界",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":24,"analysis":33},901177,"室内燃气管道管材选用时，正确的做法是（ ）。",[210,212,214,216],{"key":20,"text":211,"correct":22},"低压管道管径DN≤50时，可选用黑铁管，螺纹连接",{"key":24,"text":213,"correct":29},"低压管道管径DN＞50时，可采用无缝钢管，焊接或法兰连接",{"key":27,"text":215,"correct":22},"低压管道选用焊接钢管时，应采用加厚钢管",{"key":31,"text":217,"correct":22},"中压管道选用无缝钢管时，应采用螺纹连接",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":31,"analysis":33},901178,"采暖系统具有热惰性小、升温快、设备简单、投资省等优点，且常应用于耗热量大的建筑物，间歇使用的房间和有防火防爆要求的车间，此采暖系统为（ ）。",[222,224,226,228],{"key":20,"text":223,"correct":22},"热水采暖系统",{"key":24,"text":225,"correct":22},"低压蒸汽采暖系统",{"key":27,"text":227,"correct":22},"高压蒸汽采暖系统",{"key":31,"text":229,"correct":29},"热风采暖系统",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":20,"analysis":33},901179,"当热力站入口处热网资用压头不满足用户需要时，应设（ ）。",[234,236,238,239],{"key":20,"text":235,"correct":29},"中继泵",{"key":24,"text":237,"correct":22},"循环泵",{"key":27,"text":111,"correct":22},{"key":31,"text":113,"correct":22},{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":20,"analysis":33},901180,"在采暖系统中，闭式低位膨胀水箱为气压罐时，其宜安装在（ ）。",[244,246,248,250],{"key":20,"text":245,"correct":29},"锅炉房内",{"key":24,"text":247,"correct":22},"采暖房间内",{"key":27,"text":249,"correct":22},"露天的屋面上",{"key":31,"text":251,"correct":22},"系统的最高点",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":20,"analysis":33},901181,"室内给水系统采用设施水池、水泵的给水方式时，其不足之外为（ ）。",[256,258,260,262],{"key":20,"text":257,"correct":29},"外网水压没有充分利用",{"key":24,"text":259,"correct":22},"增加建筑物结构荷载",{"key":27,"text":261,"correct":22},"供水的安全性、可靠性低",{"key":31,"text":263,"correct":22},"不适用于城市建筑小区定时或全日供水",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":20,"analysis":33},901182,"在室内排水系统中，排水立管安装后应做（ ）。",[268,270,272,274],{"key":20,"text":269,"correct":29},"通球试验",{"key":24,"text":271,"correct":22},"高压水清洗",{"key":27,"text":273,"correct":22},"水压试验",{"key":31,"text":275,"correct":22},"化学清洗",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":31,"analysis":33},901183,"在室内排水系统的排出管施工中，隐蔽前必须做（ ）。",[280,281,283,285],{"key":20,"text":273,"correct":22},{"key":24,"text":282,"correct":22},"气压试验",{"key":27,"text":284,"correct":22},"渗漏试验",{"key":31,"text":286,"correct":29},"灌水试验",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":27,"analysis":33},901184,"目前主要用于高层建筑的垂直疏散通道和避难层(间)的建筑防火防排烟措施为( )。",[291,293,295,297],{"key":20,"text":292,"correct":22},"局部防烟",{"key":24,"text":294,"correct":22},"自然防烟",{"key":27,"text":296,"correct":29},"加压防烟",{"key":31,"text":298,"correct":22},"机械防烟",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":20,"analysis":33},901185,"在空调系统中，定风量系统的缺点为()。",[303,305,307,309],{"key":20,"text":304,"correct":29},"系统能耗大",{"key":24,"text":306,"correct":22},"室内气流分布不稳定",{"key":27,"text":308,"correct":22},"系统复杂",{"key":31,"text":310,"correct":22},"不易于管理",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":27,"analysis":33},901186,"某通风空调系统管道的工作压力管内正压为1500Pa，该风管系统属于( )系统。",[315,317,319,321],{"key":20,"text":316,"correct":22},"微压",{"key":24,"text":318,"correct":22},"低压",{"key":27,"text":320,"correct":29},"中压",{"key":31,"text":322,"correct":22},"高压",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":27,"analysis":33},901187,"在全面通风方式中，目前主要应用于汽车喷涂室等对气流、温度控制要求高的场所的通风方式为()。",[327,329,331,333],{"key":20,"text":328,"correct":22},"稀释通风",{"key":24,"text":330,"correct":22},"置换通风",{"key":27,"text":332,"correct":29},"均匀流通风",{"key":31,"text":334,"correct":22},"单向流通风",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":27,"analysis":33},901188,"工业建筑除尘系统中，分散除尘的特点为( )。",[339,341,343,345],{"key":20,"text":340,"correct":22},"系统风管较长",{"key":24,"text":342,"correct":22},"布置复杂",{"key":27,"text":344,"correct":29},"系统压力易平衡",{"key":31,"text":346,"correct":22},"粉尘回收容易",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":31,"analysis":33},901189,"主要用于管网分流、合流或旁通处各支路风量调节的风阀是()。",[351,353,355,357],{"key":20,"text":352,"correct":22},"平行式多叶调节阀",{"key":24,"text":354,"correct":22},"对开式多叶调节阀",{"key":27,"text":356,"correct":22},"菱形多叶调节阀",{"key":31,"text":358,"correct":29},"复式多叶调节阀",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":24,"analysis":33},901190,"在通风工程中，风管安装连接后，在刷油、绝热前应按规范进行严密性试验和()。",[363,365,367,369],{"key":20,"text":364,"correct":22},"漏光量检测",{"key":24,"text":366,"correct":29},"漏风量检测",{"key":27,"text":368,"correct":22},"防渗漏检测",{"key":31,"text":370,"correct":22},"气密性检验",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":20,"analysis":33},901191,"通风空调系统管安装时，矩形风管无法兰连接可采用的连接方式为()。",[375,377,379,381],{"key":20,"text":376,"correct":29},"立咬口连接",{"key":24,"text":378,"correct":22},"芯管连接",{"key":27,"text":380,"correct":22},"抱箍连接",{"key":31,"text":382,"correct":22},"承插连接",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":31,"analysis":33},901192,"送风温度低于室温，出风速度较低，送风气流与室内气流掺混量最小，且能够保存分区流态的通风方式为()。",[387,388,389,390],{"key":20,"text":334,"correct":22},{"key":24,"text":332,"correct":22},{"key":27,"text":328,"correct":22},{"key":31,"text":330,"correct":29},{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":24,"analysis":33},901193,"在通风空调系统中，圆形风管无法兰连接时，其连接形式有承插连接、芯管连接和()。",[395,397,398,399],{"key":20,"text":396,"correct":22},"插条连接",{"key":24,"text":380,"correct":29},{"key":27,"text":376,"correct":22},{"key":31,"text":400,"correct":22},"铆钉连接",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":31,"analysis":33},901194,"在通风空调系统的联合试运转中，测试和调整内容除了需进行通风机风量、风压及转速测定外，还包括( )。",[405,407,409,411],{"key":20,"text":406,"correct":22},"通风机试运转",{"key":24,"text":408,"correct":22},"水泵试运转",{"key":27,"text":410,"correct":22},"制冷机试运转",{"key":31,"text":412,"correct":29},"通风机、制冷机、空调器的噪声测定",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},901195,"铝板风管采用法兰连接时，其固定螺栓、垫圈的种类应为()。",[417,419,421,423],{"key":20,"text":418,"correct":22},"不锈钢螺栓及垫圈",{"key":24,"text":420,"correct":29},"镀锌螺栓及垫圈",{"key":27,"text":422,"correct":22},"喷刷涂料的普通碳素钢螺栓及垫圈",{"key":31,"text":424,"correct":22},"增强尼龙螺栓及垫圈",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":24,"analysis":33},901196,"民用建筑空调制冷工程中，采用时间最长、使用数量最多的冷水机组是()。",[429,431,433,435],{"key":20,"text":430,"correct":22},"离心式冷水机组",{"key":24,"text":432,"correct":29},"活塞式冷水机组",{"key":27,"text":434,"correct":22},"螺杆式冷水机组",{"key":31,"text":436,"correct":22},"转子式冷水机组",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":20,"analysis":33},901197,"空调系统中，风机盘管系统适用的场合为()。",[441,443,445,447],{"key":20,"text":442,"correct":29},"空间不大、负荷密度高",{"key":24,"text":444,"correct":22},"空间大、负荷密度高",{"key":27,"text":446,"correct":22},"空间不大、负荷密度不高",{"key":31,"text":448,"correct":22},"空间大、负荷密度不高",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":27,"analysis":33},901198,"具有质量轻、制冷系数较高、容量调节方便等优点，但用于小制冷量时能效下降大，负荷太低时有喘振现象。广泛使用在大中型商业建筑空调系统中，该制冷装置为（ ）。",[453,454,455,456],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":22},{"key":27,"text":430,"correct":29},{"key":31,"text":457,"correct":22},"冷风机组",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":31,"analysis":33},901199,"防爆等级低的防爆通风机，叶轮和机壳的制作材料为（ ）。",[462,464,466,468],{"key":20,"text":463,"correct":22},"叶轮和机壳均用钢板",{"key":24,"text":465,"correct":22},"叶轮和机壳均用铝板",{"key":27,"text":467,"correct":22},"叶轮用钢板、机壳用铝板",{"key":31,"text":469,"correct":29},"叶轮用铝板、机壳用钢板",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":20,"analysis":33},901200,"它能广泛应用于无机气体如硫氧化物、氮氢化物、硫化氢、氯化氢等有害气体的净化，同时能进行除尘，适用于处理气体量大的场合。与其他净化方法相比费用较低。这种有害气体净化方法为（ ）。",[474,476,478,480],{"key":20,"text":475,"correct":29},"吸收法",{"key":24,"text":477,"correct":22},"吸附法",{"key":27,"text":479,"correct":22},"冷凝法",{"key":31,"text":481,"correct":22},"燃烧法",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":27,"analysis":33},901201,"根据《通用安装工程工程量计算规范》GB50856-2013，下列项目以“m”为计量单位的是（ ）。",[486,488,490,492],{"key":20,"text":487,"correct":22},"碳钢通风管",{"key":24,"text":489,"correct":22},"塑料通风管",{"key":27,"text":491,"correct":29},"柔性软风管",{"key":31,"text":493,"correct":22},"净化通风管",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":27,"analysis":33},901202,"将回风与新风在空气处理设备前混合，再一起进入空气处理设备，目前是空调中应用最广泛的形式，这种空调系统形式是（ ）。",[498,500,502,504],{"key":20,"text":499,"correct":22},"直流式系统",{"key":24,"text":501,"correct":22},"封闭式系统",{"key":27,"text":503,"correct":29},"一次回风系统",{"key":31,"text":505,"correct":22},"二次回风系统",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":31,"analysis":33},901203,"按空气处理设备情况分类，设置风机盘管机组的空调系统应属于（ ）。",[510,512,514,516],{"key":20,"text":511,"correct":22},"集中式系统",{"key":24,"text":513,"correct":22},"分散式系统",{"key":27,"text":515,"correct":22},"局部系统",{"key":31,"text":517,"correct":29},"半集中式系统",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":20,"analysis":33},901204,"通风系统中抗性消声器的消声性能为（ ）。",[522,524,526,528],{"key":20,"text":523,"correct":29},"良好的低中频消声",{"key":24,"text":525,"correct":22},"良好的低中高频消声",{"key":27,"text":527,"correct":22},"良好的低高频消声",{"key":31,"text":529,"correct":22},"良好的中高频消声",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":24,"analysis":33},901205,"某除尘器结构简单、投资低、占地面积少、除尘效率高，能同时进行有害气体的净化，但回收物料处理较困难。此种除尘器是（ ）。",[534,536,538,540],{"key":20,"text":535,"correct":22},"旋风除尘器",{"key":24,"text":537,"correct":29},"湿式除尘器",{"key":27,"text":539,"correct":22},"过滤式除尘器",{"key":31,"text":541,"correct":22},"静电除尘器",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":27,"analysis":33},901206,"在建筑高度过高和重要的建筑物中，其垂直通道的防排烟方法为（ ）。",[546,548,550,551],{"key":20,"text":547,"correct":22},"自然排烟",{"key":24,"text":549,"correct":22},"机械排烟",{"key":27,"text":296,"correct":29},{"key":31,"text":552,"correct":22},"负压防烟",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":24,"analysis":33},901207,"靠外墙的防烟楼梯间及其前室、消防电梯间前室和合用前室，宜采用（ ）方式。",[557,558,559,560],{"key":20,"text":549,"correct":22},{"key":24,"text":547,"correct":29},{"key":27,"text":296,"correct":22},{"key":31,"text":561,"correct":22},"全面通风",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":31,"analysis":33},901208,"置换通风送风分布器的位置通常设在（ ）。",[566,568,570,572],{"key":20,"text":567,"correct":22},"靠近房顶处",{"key":24,"text":569,"correct":22},"房顶上",{"key":27,"text":571,"correct":22},"房顶与地板中间处",{"key":31,"text":573,"correct":29},"靠近地板处",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":27,"analysis":33},901209,"通风工程中，不属于全面通风的是（ ）",[578,579,580,582],{"key":20,"text":328,"correct":22},{"key":24,"text":334,"correct":22},{"key":27,"text":581,"correct":29},"双向流通风",{"key":31,"text":332,"correct":22},{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":27,"analysis":33},901210,"安装吊顶式空调箱，以下选项符合规定的是（ ）。",[587,589,591,593],{"key":20,"text":588,"correct":22},"单独设置机房",{"key":24,"text":590,"correct":22},"因风机为低噪声风机，可不考虑减振措施",{"key":27,"text":592,"correct":29},"机组送风口与送风管连接采用帆布软管",{"key":31,"text":594,"correct":22},"一般情况下吊装机组风量不超过10000m3／h",[596,599,602,605,608,611],{"id":15,"name":597,"category":7,"favorite":598},"领导干部任职前廉政法规知识测试题",92,{"id":600,"name":601,"category":7,"favorite":15},595,"建筑结构与设备",{"id":603,"name":604,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":606,"name":607,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":609,"name":610,"category":7,"favorite":8},534,"BIM工程师",{"id":612,"name":610,"category":7,"favorite":8},535]