[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-583-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":604},{"id":5,"name":6,"category":7,"favorite":8},583,"建设工程技术与计量（安装)","建筑工程",0,18,50,2472,[13,34,46,58,70,82,94,103,115,127,137,146,158,170,182,194,206,218,230,242,254,266,278,289,301,313,325,336,348,360,372,384,396,406,418,430,442,454,466,476,488,497,509,521,533,545,557,569,581,593],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},901005,1,"单选题","与离心式通风机相比，轴流式通风机的使用特点为（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","风压高、流量小",false,{"key":24,"text":25,"correct":22},"B","体积较大",{"key":27,"text":28,"correct":29},"C","动叶、导叶可调节",true,{"key":31,"text":32,"correct":22},"D","经济性较差","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},901006,"既适用于输送腐蚀性、易燃、易爆、剧毒及贵重液体，也适用于输送高温、高压、高熔点液体，广泛用于石化及国防工业的泵为（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":29},"无填料泵",{"key":24,"text":41,"correct":22},"离心式耐腐蚀泵",{"key":27,"text":43,"correct":22},"筒式离心泵",{"key":31,"text":45,"correct":22},"离心式杂质泵",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},901007,"排出压力可高达18MPa，主要用于流量较大、扬程较高的城市给水、矿山排水和输油管线的泵为（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":29},"蜗壳式多级离心泵",{"key":24,"text":53,"correct":22},"单级双吸离心泵",{"key":27,"text":55,"correct":22},"离心式井泵",{"key":31,"text":57,"correct":22},"分段式多级离心水泵",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},901008,"风机安装完毕后需进行试运转，风机试运转时应符合的要求为（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"以电动机带动的风机经一次启动后即可直接进入运转",{"key":24,"text":65,"correct":22},"风机运转达到额定转速后，应将风机调理到设计负荷",{"key":27,"text":67,"correct":29},"风机启动后，不得在临界转速附近停留",{"key":31,"text":69,"correct":22},"风机的润滑油冷却系统中的冷却水压力应高于油压",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},901009,"具有绝对不泄漏的优点，最适合输送和计量易燃易爆、强腐蚀、剧毒、有放射性和贵重液体的泵为（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":29},"隔膜计量泵",{"key":24,"text":77,"correct":22},"柱塞计量泵",{"key":27,"text":79,"correct":22},"气动计量泵",{"key":31,"text":81,"correct":22},"齿轮计量泵",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},901010,"既可以在水平方向运输物料，也可以按一定倾斜角度向上或向下运输物料，且结构简单，经济性能好的固体输送设备是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"斗式提升机",{"key":24,"text":89,"correct":29},"带式输送机",{"key":27,"text":91,"correct":22},"链式输送机",{"key":31,"text":93,"correct":22},"螺旋输送机",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},901011,"某输送机结构简单，安装、运行、维护方便，节省能量，操作安全可靠，使用寿命长，在规定距离内每吨物料运费较其他设备低。此种输送设备为（ ）。",[98,100,101,102],{"key":20,"text":99,"correct":22},"斗式输送机",{"key":24,"text":91,"correct":22},{"key":27,"text":93,"correct":22},{"key":31,"text":89,"correct":29},{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":31,"analysis":33},901012,"具有全封闭式的机壳，被输送的物料在机壳内移动，不污染环境，能防止灰尘逸出的固体输送设备是（ ）。",[107,109,111,113],{"key":20,"text":108,"correct":22},"平行带式输送机",{"key":24,"text":110,"correct":22},"转斗输送机",{"key":27,"text":112,"correct":22},"鳞板输送机",{"key":31,"text":114,"correct":29},"埋刮板输送机",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":31,"analysis":33},901013,"机械设备安装工程中，常用于固定静置的简单设备或辅助设备的地脚螺栓为（ ）。",[119,121,123,125],{"key":20,"text":120,"correct":22},"长地脚螺栓",{"key":24,"text":122,"correct":22},"可拆卸地脚螺栓",{"key":27,"text":124,"correct":22},"活动地脚螺栓",{"key":31,"text":126,"correct":29},"胀锚地脚螺栓",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":24,"analysis":33},901014,"适用于有强烈振动和冲击的重型设备，且是一种可拆卸的地脚螺栓。这种螺栓为（ ）。",[131,133,134,135],{"key":20,"text":132,"correct":22},"短地脚螺栓",{"key":24,"text":120,"correct":29},{"key":27,"text":126,"correct":22},{"key":31,"text":136,"correct":22},"粘接地脚螺栓",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":20,"analysis":33},901015,"适用于有强烈振动和冲击的重型设备在基础上固定所采用的地脚螺栓为（ ）。",[141,142,144,145],{"key":20,"text":124,"correct":29},{"key":24,"text":143,"correct":22},"固定地脚螺栓",{"key":27,"text":126,"correct":22},{"key":31,"text":136,"correct":22},{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":27,"analysis":33},901016,"机械设备按使用范围可分为通用机械设备和专用机械设备，下列设备中属于专用机械设备的是（ ）。",[150,152,154,156],{"key":20,"text":151,"correct":22},"铸造设备",{"key":24,"text":153,"correct":22},"锻压设备",{"key":27,"text":155,"correct":29},"过滤设备",{"key":31,"text":157,"correct":22},"压缩机",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":20,"analysis":33},901017,"在机械设备安装中，对中、小型形状复杂的装配件，采用清洗液浸、涮清洗后，最终清洗宜采用（ ）。",[162,164,166,168],{"key":20,"text":163,"correct":29},"超声波清洗",{"key":24,"text":165,"correct":22},"喷洗",{"key":27,"text":167,"correct":22},"浸一喷联合清洗",{"key":31,"text":169,"correct":22},"擦洗",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":20,"analysis":33},901018,"按作用原理分类，属于透平式风机的是（ ）。",[174,176,178,180],{"key":20,"text":175,"correct":29},"混流式",{"key":24,"text":177,"correct":22},"滑片式",{"key":27,"text":179,"correct":22},"螺杆式",{"key":31,"text":181,"correct":22},"罗茨式",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":27,"analysis":33},901019,"在禁油条件下工作的零、部件及管路在安装前应进行（ ）。",[186,188,190,192],{"key":20,"text":187,"correct":22},"酸洗",{"key":24,"text":189,"correct":22},"碱洗",{"key":27,"text":191,"correct":29},"脱脂",{"key":31,"text":193,"correct":22},"用溶剂油清洗",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":31,"analysis":33},901020,"电动机和泵制成一体，浸入水中进行抽吸和输送水的泵是（ ）。",[198,200,202,204],{"key":20,"text":199,"correct":22},"离心泵",{"key":24,"text":201,"correct":22},"浅井泵",{"key":27,"text":203,"correct":22},"轴流泵",{"key":31,"text":205,"correct":29},"潜水泵",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":20,"analysis":33},901021,"下列关于受热面蒸发率和受热面发热率叙述正确的是（ ）。",[210,212,214,216],{"key":20,"text":211,"correct":29},"每平方米受热面每小时产生的蒸汽量称为锅炉受热面蒸发率",{"key":24,"text":213,"correct":22},"每平方米受热面每小时产生的蒸汽量称为锅炉受热面发热率",{"key":27,"text":215,"correct":22},"受热面蒸发率数值越小，表示传热效果越好",{"key":31,"text":217,"correct":22},"受热面发热率数值越小，表示传热效果越好",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":24,"analysis":33},901022,"下列对煮炉的过程，表述错误的是（ ）。",[222,224,226,228],{"key":20,"text":223,"correct":22},"煮炉时间通常为48～72小时",{"key":24,"text":225,"correct":29},"煮炉的最后48小时宜使蒸汽压力保持在额定工作压力的75％",{"key":27,"text":227,"correct":22},"将煮炉用药品先调成20％浓度的水溶液，搅拌均匀",{"key":31,"text":229,"correct":22},"加药时，不得使药液进入过热器内",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":27,"analysis":33},901023,"根据生产工艺要求，烟气除尘率达到85％左右既满足要求，可选用没有运动部件，结构简单、造价低、维护管理方便，且广泛应用的除尘设备是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":22},"麻石水膜除尘器",{"key":24,"text":237,"correct":22},"旋风水膜除尘器",{"key":27,"text":239,"correct":29},"旋风除尘器",{"key":31,"text":241,"correct":22},"静电除尘器",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":31,"analysis":33},901024,"依据《通用安装工程工程量计算规范》GB50856-2013的规定，中压锅炉本体设备安装工程量计量时，按图示数量以“套”计算的项目是（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":22},"旋风分离器",{"key":24,"text":249,"correct":22},"省煤器",{"key":27,"text":251,"correct":22},"管式空气预热器",{"key":31,"text":253,"correct":29},"炉排及燃烧装置",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":31,"analysis":33},901025,"额定蒸发量2t\u002Fh的锅炉，其水位计和安全阀（不包括省煤器上的安全阀）的安装数量为（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"一个水位计，一个安全阀",{"key":24,"text":261,"correct":22},"一个水位计，至少两个安全阀",{"key":27,"text":263,"correct":22},"两个水位计，一个安全阀",{"key":31,"text":265,"correct":29},"两个水位计，至少两个安全阀",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":31,"analysis":33},901026,"锅炉有效利用热量与单位时间内锅炉的输入热量的百分比称（ ）。",[270,272,274,276],{"key":20,"text":271,"correct":22},"传热效率",{"key":24,"text":273,"correct":22},"热量利用率",{"key":27,"text":275,"correct":22},"工作效率",{"key":31,"text":277,"correct":29},"锅炉热效率",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":20,"analysis":33},901027,"锅炉本体主要由“锅”和“炉”组成，下列哪项不是“炉”所包括的设备（ ）。",[282,283,285,287],{"key":20,"text":249,"correct":29},{"key":24,"text":284,"correct":22},"煤斗",{"key":27,"text":286,"correct":22},"炉排",{"key":31,"text":288,"correct":22},"送风装置",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":24,"analysis":33},901028,"锅炉水处理方法的选择要根据水质情况选定，当地下水用于工业锅炉时，应采取的处理方法为（ ）。",[293,295,297,299],{"key":20,"text":294,"correct":22},"除碱",{"key":24,"text":296,"correct":29},"软化、除氧",{"key":27,"text":298,"correct":22},"除盐",{"key":31,"text":300,"correct":22},"软化、除盐",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":31,"analysis":33},901029,"锅炉安全附件安装中，常用的水位计有玻璃管式、磁翻柱液位计以及（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"波纹管式水位计",{"key":24,"text":308,"correct":22},"弹簧式水位计",{"key":27,"text":310,"correct":22},"杠杆式水位计",{"key":31,"text":312,"correct":29},"平板式水位计",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":33},901030,"锅炉本体安装时，对流式过热器安装的部位应为（ ）。",[317,319,321,323],{"key":20,"text":318,"correct":22},"水平悬挂于锅炉尾部",{"key":24,"text":320,"correct":29},"垂直悬挂于锅炉尾部",{"key":27,"text":322,"correct":22},"包覆于炉墙内壁上",{"key":31,"text":324,"correct":22},"包覆于锅炉的炉顶部",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":31,"analysis":33},901031,"衡量蒸汽锅炉热经济性的指标是（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":22},"蒸发量",{"key":24,"text":332,"correct":22},"蒸汽压力和温度",{"key":27,"text":334,"correct":22},"受热面蒸发率",{"key":31,"text":277,"correct":29},{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":24,"analysis":33},901032,"容量是锅炉的主要性能指标之一，热水锅炉容量单位是（ ）。",[340,342,344,346],{"key":20,"text":341,"correct":22},"t／h",{"key":24,"text":343,"correct":29},"MW",{"key":27,"text":345,"correct":22},"kg／（m2.h）",{"key":31,"text":347,"correct":22},"kj／（m2.h）",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":27,"analysis":33},901035,"下列存储装置属于热气溶胶预制灭火系统的为（ ）。",[352,354,356,358],{"key":20,"text":353,"correct":22},"储存容器",{"key":24,"text":355,"correct":22},"容器阀",{"key":27,"text":357,"correct":29},"引发器",{"key":31,"text":359,"correct":22},"集流管",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":27,"analysis":33},901036,"在泡沫灭火系统中，非吸气型泡沫喷头可以采用（ ）",[364,366,368,370],{"key":20,"text":365,"correct":22},"蛋白泡沫液",{"key":24,"text":367,"correct":22},"氟蛋白泡沫液",{"key":27,"text":369,"correct":29},"水成膜泡沫液",{"key":31,"text":371,"correct":22},"抗溶性泡沫液",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":27,"analysis":33},901037,"从环保的角度来看，较为理想的灭火剂为（ ）。",[376,378,380,382],{"key":20,"text":377,"correct":22},"二氧化碳灭火系统",{"key":24,"text":379,"correct":22},"七氟丙烷灭火系统",{"key":27,"text":381,"correct":29},"IG541混合气体灭火系统",{"key":31,"text":383,"correct":22},"热气溶胶预制灭火系统",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":31,"analysis":33},901038,"一般适用于工业领域中的石化、交通、电力部门和高层建筑内的柴油发电机房、燃油锅炉等处的灭火系统为（ ）。",[388,390,392,394],{"key":20,"text":389,"correct":22},"自动喷水干式灭火系统",{"key":24,"text":391,"correct":22},"重复启闭预作用灭火系统",{"key":27,"text":393,"correct":22},"水幕系统",{"key":31,"text":395,"correct":29},"水喷雾灭火系统",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":33},901039,"储存装置由储存容器、容器阀和集流管等组成的灭火系统为（ ）。",[400,402,403,405],{"key":20,"text":401,"correct":29},"二氧化碳灭火管网系统",{"key":24,"text":379,"correct":22},{"key":27,"text":404,"correct":22},"IG541预制灭火系统",{"key":31,"text":383,"correct":22},{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":27,"analysis":33},901040,"IG541混合气体灭火系统不可用于扑救（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"电子计算机机房火灾",{"key":24,"text":413,"correct":22},"电气火灾",{"key":27,"text":415,"correct":29},"D类活泼金属火灾",{"key":31,"text":417,"correct":22},"可溶化的固体火灾",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":33},901041,"室内消火栓给水管网和自动喷水灭火系统的管网设置方式应为（ ）。",[422,424,426,428],{"key":20,"text":423,"correct":29},"分开设置",{"key":24,"text":425,"correct":22},"报警阀后分开",{"key":27,"text":427,"correct":22},"合并设置",{"key":31,"text":429,"correct":22},"报警阀前合并",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":27,"analysis":33},901042,"当建筑物的高度超过50m或消火栓处的静水压力超过0.8MPa时，应采用（ ）。",[434,436,438,440],{"key":20,"text":435,"correct":22},"设水箱的室内消火栓给水系统",{"key":24,"text":437,"correct":22},"设消防水泵和水箱的室内消火栓给水系统",{"key":27,"text":439,"correct":29},"分区给水的室内消火栓给水系统",{"key":31,"text":441,"correct":22},"区域集中的室内高压消火栓给水系统",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":33},901043,"当室内消防用水量不能满足消防要求时，消防车可通过连接一设备向室内管网供水灭火，消防车所连接的设备是（ ）。",[446,448,450,452],{"key":20,"text":447,"correct":22},"消火栓",{"key":24,"text":449,"correct":29},"水泵接合器",{"key":27,"text":451,"correct":22},"压力开关",{"key":31,"text":453,"correct":22},"气压水罐",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":20,"analysis":33},901044,"绝热性能好、无毒、能消烟、能排除有毒气体，灭火剂用量和水用量少，水渍损失少，灭火后泡沫易清除，但不能扑救立式油罐内火灾的泡沫灭火系统为（ ）。",[458,460,462,464],{"key":20,"text":459,"correct":29},"高倍数泡沫灭火系统",{"key":24,"text":461,"correct":22},"中倍数泡沫灭火系统",{"key":27,"text":463,"correct":22},"氟蛋白泡沫灭火系统",{"key":31,"text":465,"correct":22},"成膜氟蛋白泡沫灭火系统",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":27,"analysis":33},901045,"具有冷却、乳化、稀释等作用，且不仅可以用于灭火，还可以用来控制火势及防护冷却的灭火系统为（ ）。",[470,472,473,474],{"key":20,"text":471,"correct":22},"自动喷水湿式灭火系统",{"key":24,"text":389,"correct":22},{"key":27,"text":395,"correct":29},{"key":31,"text":475,"correct":22},"水幕灭火系统",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":20,"analysis":33},901046,"在自动喷水灭火系统管道安装中，下列做法正确的是（ ）。",[480,482,484,486],{"key":20,"text":481,"correct":29},"管道穿过楼板时加设套管，套管应高出楼面50mm",{"key":24,"text":483,"correct":22},"管道安装顺序为先支管，后配水管和干管",{"key":27,"text":485,"correct":22},"管道弯头处应采用补芯",{"key":31,"text":487,"correct":22},"管道横向安装宜设1‰~2‰的坡度，坡向立管",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":24,"analysis":33},901047,"水压高、水量大并具有冷却、窒熄、乳化、稀释作用，不仅用于灭火还可控制火势，主要用于保护火灾危险性大、扑救难度大的专用设备或设施的灭火系统为（ ）。",[492,493,494,496],{"key":20,"text":393,"correct":22},{"key":24,"text":395,"correct":29},{"key":27,"text":495,"correct":22},"自动喷水雨淋系统",{"key":31,"text":391,"correct":22},{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":31,"analysis":33},901048,"下列可燃性液体发生火灾时，可采用普遍蛋白泡沫灭火剂的是（ ）。",[501,503,505,507],{"key":20,"text":502,"correct":22},"乙醇",{"key":24,"text":504,"correct":22},"丙醇",{"key":27,"text":506,"correct":22},"醋酸乙酯",{"key":31,"text":508,"correct":29},"柴油",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":27,"analysis":33},901049,"在室内消火栓系统中，无缝钢管采用法兰连接，在保证镀锌加工尺寸要求的前提下，其管道配件短管连接应采用（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":22},"法兰连接",{"key":24,"text":516,"correct":22},"螺纹连接",{"key":27,"text":518,"correct":29},"焊接连接",{"key":31,"text":520,"correct":22},"卡箍管接头",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":27,"analysis":33},901050,"在气体灭火系统中，二氧化碳灭火系统不适用于扑灭（ ）。",[525,527,529,531],{"key":20,"text":526,"correct":22},"多油开关及发电机房火灾",{"key":24,"text":528,"correct":22},"大中型电子计算机房火灾",{"key":27,"text":530,"correct":29},"硝化纤维和火药库火灾",{"key":31,"text":532,"correct":22},"文物资料珍藏室火灾",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":31,"analysis":33},901051,"与自热喷水灭火系统相比，水喷雾灭火系统对水压、水量的要求应为（ ）。",[537,539,541,543],{"key":20,"text":538,"correct":22},"水压低、力量小",{"key":24,"text":540,"correct":22},"水压高、水量小",{"key":27,"text":542,"correct":22},"水压低、水量大",{"key":31,"text":544,"correct":29},"水压高、水量大",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":27,"analysis":33},901053,"省电、耐振、寿命长、发光强、启动慢、显色性差和功率因数低的电光源应是()。",[549,551,553,555],{"key":20,"text":550,"correct":22},"白炽灯",{"key":24,"text":552,"correct":22},"光灯",{"key":27,"text":554,"correct":29},"高压汞灯",{"key":31,"text":556,"correct":22},"金属卤化物灯",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":24,"analysis":33},901054,"某化工车间电气配管为明敷，车间内潮湿，空气中有轻微腐蚀气体，且该管受到一定机械外力时，应选择的管道为( )。",[561,563,565,567],{"key":20,"text":562,"correct":22},"电线管",{"key":24,"text":564,"correct":29},"焊接钢管",{"key":27,"text":566,"correct":22},"硬质聚氯乙烯管",{"key":31,"text":568,"correct":22},"半硬质阻燃管",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":24,"analysis":33},901055,"被用来限制机械运动的位置和行程，使运动机械按一定位置或行程自动停止、反向运动、变速运动或自动往返等的电气设备为（ ）。",[573,575,577,579],{"key":20,"text":574,"correct":22},"自动开关",{"key":24,"text":576,"correct":29},"行程开关",{"key":27,"text":578,"correct":22},"接近开关",{"key":31,"text":580,"correct":22},"转换开关",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":24,"analysis":33},901056,"能够满足电动机平稳启动，同时可靠性高、维护量小、参数设置简单的电动机启动方法是（ ）。",[585,587,589,591],{"key":20,"text":586,"correct":22},"直接启动",{"key":24,"text":588,"correct":29},"软启动器启动",{"key":27,"text":590,"correct":22},"变频启动",{"key":31,"text":592,"correct":22},"星-三角启动",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":31,"analysis":33},901057,"优点是发光效率高、省电、附件少，功率因数接近于1。缺点是寿命短，只有大约1000h左右的电光源为（ ）。",[597,599,600,602],{"key":20,"text":598,"correct":22},"荧光灯",{"key":24,"text":550,"correct":22},{"key":27,"text":601,"correct":22},"低压钠灯",{"key":31,"text":603,"correct":29},"自镇流高压汞灯",[605,608,611,614,617,620],{"id":15,"name":606,"category":7,"favorite":607},"领导干部任职前廉政法规知识测试题",92,{"id":609,"name":610,"category":7,"favorite":15},595,"建筑结构与设备",{"id":612,"name":613,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":615,"name":616,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":618,"name":619,"category":7,"favorite":8},534,"BIM工程师",{"id":621,"name":619,"category":7,"favorite":8},535]