[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-901920":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},901920,583,2,"多选题","(2014年)球罐水压试验过程中要进行基础沉降观测，并做好实测记录。正确的观测时点为()。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","充水前",true,{"key":16,"text":17,"correct":18},"B","充水到1\u002F2球罐本体高度",false,{"key":20,"text":21,"correct":14},"C","充满水24h",{"key":23,"text":24,"correct":14},"D","放水后","ACD","该题主要考察的是水压试验的要求，水压试验的要求：(1)水压试验压力应为设计压力的1.25倍。设计有特殊规定时，按设计文件要求进行，但不应小于球罐设计压力的1.25倍。(2)试验用水应为清洁的工业用水，对碳素钢和16MnR钢制球罐水温不得低于5℃；其他低合金钢球罐试压用水温度不得低于15℃；对新钢种的试验水温应按设计规定进行。(3)球罐水压试验过程中要进行基础沉降观测，观测应分别在充水前、充水到1\u002F3、充水到2\u002F3球罐本体高度、充满水24h和放水后各个阶段进行观测，并做好实测记录。",{"id":6,"name":28,"category":29,"favorite":30},"建设工程技术与计量（安装)","建筑工程",0]