[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-901289":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},901289,583,1,"单选题","气柜施工过程中，根据焊接规范要求，应对焊接质量进行检验，以下操作正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","气柜壁板所有对焊焊缝均应作真空试漏试验",false,{"key":16,"text":17,"correct":18},"B","下水封的焊缝应进行注水试验",true,{"key":20,"text":21,"correct":14},"C","水槽壁对接焊缝应作氨气渗漏试验",{"key":23,"text":24,"correct":14},"D","气柜底板焊缝应作煤油渗透试验","2020版教材P341 湿式气柜的制作，安装施工方法。 （1）施工过程中的焊接质量检验。焊接规范要求如下： 1）气柜壁板所有对焊焊缝均应经煤油渗透试验。 2）下水封的焊缝应进行注水试验，不漏为合格。 3）当钢板厚度为8mm以上时，水槽壁对接焊缝应进行元损探伤检查，抽查数量，立焊缝不少于10%，环缝不少于5%。如不合格，则应在该焊工所焊焊缝有缺陷部分的延伸方向加倍检查，或在其他可疑部分进行补充探伤，如仍不合格，则该焊工所焊的焊缝应100%探伤检查。",{"id":6,"name":27,"category":28,"favorite":29},"建设工程技术与计量（安装)","建筑工程",0]