[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-900634":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},900634,583,1,"单选题","蒸汽锅炉安全阀的安装和试验，正确的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","安装前安全阀应按50%抽检，进行严密性试验",false,{"key":16,"text":17,"correct":14},"B","蒸发量小于0.5t\u002Fh 的锅炉，至少应装设两个安全阀",{"key":19,"text":20,"correct":21},"C","对装有过热器的锅炉，过热器上的安全阀应先开启",true,{"key":23,"text":24,"correct":14},"D","省煤器安全阀整定压力调整，应在蒸汽严密性试验之后用水压的方法进行","蒸汽锅炉安全阀的安装和试验，应符合下列要求： 1）安装前安全阀应逐个进行严密性试验； 2）蒸发量大于0.5t\u002Fh 的锅炉，至少应装设两个安全阀（不包括省煤器上的安全阀）。 锅炉上必须有一个安全阀按表中较低的整定压力进行调整；对装有过热器的锅炉，按较低压力进行整定的安全阀必须是过热器上的安全阀，过热器上的安全阀应先开启； 4）省煤器安全阀整定压力调整，应在蒸汽严密性试验前用水压的方法进行。",{"id":6,"name":27,"category":28,"favorite":29},"建设工程技术与计量（安装)","建筑工程",0]