[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-900241":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},900241,583,1,"单选题","(2015年)对有严重锈蚀和污染的液体管道，当使用一般清洗方法未能达到要求时，可采取将管道分段进行( )。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","高压空气吹扫",false,{"key":16,"text":17,"correct":14},"B","高压蒸汽吹扫",{"key":19,"text":20,"correct":21},"C","高压水冲洗",true,{"key":23,"text":24,"correct":14},"D","酸洗","该题主要考察的是：水清洗的内容，“4. 水清洗(1）水冲洗应使用洁净水，冲洗不锈钢、镇及镇合金管道时，水中氯离子含量不得超过25×10 6(25ppm）。(2）水冲洗的流速不应小于1. 5m\u002Fs，冲洗压力不得超过管道的设计压力。(3）冲洗排放管的截面积不应小于被冲洗管截面积的60%。排水时，不得形成负压。(4）管道水冲洗应连续进行，以排出口的水色和透明度与入口处目测一致为合格。(5)对有严重锈蚀和污染的管道，当使用一般清洗方法未能达到要求时，可采用将管道分段进行高压水冲洗。”",{"id":6,"name":27,"category":28,"favorite":29},"建设工程技术与计量（安装)","建筑工程",0]