[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-892914":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},892914,579,2,"多选题","关于闸门埋件安装和启闭试验，下列说法不正确的有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","埋件安装完并检查合格后如有碰撞应予复测",false,{"key":16,"text":17,"correct":18},"B","埋件的二期混凝土强度达到75%以后方可拆模",true,{"key":20,"text":21,"correct":14},"C","有条件时事故闸门应做动水启闭试验",{"key":23,"text":24,"correct":18},"D","闸门安装好后应在有水情况下做全行程启闭试验",{"key":26,"text":27,"correct":14},"E","启闭试验前应检查充水阀在最低位置时止水是否严密","BD","A项，埋件安装完并经检查合格后，应在5d内浇筑二期混凝土，如过期或有碰撞，应予复测，复测合格，方可浇筑二期混凝土。B项，埋件的二期混凝土强度达到70%以后方可拆模，拆模后应对埋件进行复测，并做好记录。C项，有条件时，工作闸门应做动水启闭试验，事故闸门应做动水关闭试验。D项，闸门安装好后，应在无水情况下做全行程启闭试验。E项，启闭试验前应检查充水阀在行程范围内的升降是否自如，在最低位置时止水是否严密。",{"id":6,"name":31,"category":32,"favorite":33},"[水利工程]建设工程计量与计价实务","建筑工程",0]