[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-892897":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},892897,579,2,"多选题","下列属于信息化系统自动化监测的有（ ）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","水位监测",true,{"key":16,"text":17,"correct":14},"B","流量监测",{"key":19,"text":20,"correct":14},"C","墒情自动测报",{"key":22,"text":23,"correct":14},"D","水工建筑物安全自动监测",{"key":25,"text":26,"correct":27},"E","工程运行基础数据监测",false,"ABCD","信息化系统根据工程运行调度的需要进行自动化监测，相关内容包括：①水位监测。采集信息宜采用4～20mA模拟量信号或现地总线等方式接入现场采集终端。②流量监测。根据情况选用超声波流量计、电磁流量计、缆道测流或通过水位与闸门开度测算等方式，采用4～20mA模拟量信号或现场总线等方式接入现地采集终端。③在线水质监测。宜采用4～20mA模拟信号或现地总线等方式接入现地采集终端，或根据工程实际情况，辅以人工采样、后台分析和手工录入方式。④水雨情自动测报。宜接入水雨情采集终端，配置相应的应用软件，实现应答式、自报式或混合式的数据采集功能。⑤墒情自动测报。可根据墒情站点，进行土壤含水量信息采集，接入墒情采集终端，配置相应的应用软件，实现数据采集功能。⑥水工建筑物安全自动监测。信息应接入监测终端，并应配置相应的应用软件，实现数据采集功能。⑦地下水监测。信息应接入监测终端，并应配置相应的应用软件，实现数据采集功能。",{"id":6,"name":31,"category":32,"favorite":33},"[水利工程]建设工程计量与计价实务","建筑工程",0]