[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-577-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":616},{"id":5,"name":6,"category":7,"favorite":8},577,"[安装工程]建设工程计量与计价实务","建筑工程",0,7,50,1537,[13,34,46,58,70,82,94,106,118,129,141,153,165,177,189,201,213,225,237,249,261,273,285,297,309,321,333,345,357,369,381,393,405,417,427,439,451,463,475,487,499,511,523,535,547,556,568,580,592,604],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},890678,1,"单选题","室内排水立管安装，设置要求有（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","宜设置在与卧室相邻的内墙",false,{"key":24,"text":25,"correct":26},"B","立管上的管卡间距不得大于3m",true,{"key":28,"text":29,"correct":22},"C","不宜靠近外墙安装",{"key":31,"text":32,"correct":22},"D","立管穿楼板时，必须设置填料套管","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},890679,"组装速度快，组装应力小，不需要很大的吊装机械和太大的施工场地，适用任意大小球罐拼装，但高空作业量大。该组装方法是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"分片组装法",{"key":24,"text":41,"correct":22},"拼大片组装法",{"key":28,"text":43,"correct":22},"环带组装法",{"key":31,"text":45,"correct":22},"分带分片混合组装法",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},890680,"对于球罐焊缝内在质量的检验，选择100%射线探伤检验时，对于球壳板厚度大于38mm的焊缝还应做（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"超声波探伤复检",{"key":24,"text":53,"correct":22},"磁粉探伤复检",{"key":28,"text":55,"correct":22},"渗透探伤复检",{"key":31,"text":57,"correct":22},"涡流检测复检",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},890681,"塔器的直径和高度较大，质量在350～700t之间时，吊装可采用的起重设备为（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"单抱杆",{"key":24,"text":65,"correct":26},"双抱杆",{"key":28,"text":67,"correct":22},"轮胎式起重机",{"key":31,"text":69,"correct":22},"塔式起重机",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},890682,"传热系数较小，传热面受到容器限制，只适用于传热量不大的场合，该换热器为（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"夹套式换热器",{"key":24,"text":77,"correct":22},"蛇管式换热器",{"key":28,"text":79,"correct":22},"列管式换热器",{"key":31,"text":81,"correct":22},"板片式换热器",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},890683,"公称直径为70mm的压缩空气管道，其连接方式宜采用（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"法兰连接",{"key":24,"text":89,"correct":22},"螺纹连接",{"key":28,"text":91,"correct":26},"焊接",{"key":31,"text":93,"correct":22},"套管连接",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},890684,"设置在方形补偿器两侧的第一个支架形式应为（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"固定支架",{"key":24,"text":101,"correct":22},"导向支架",{"key":28,"text":103,"correct":26},"滑动支架",{"key":31,"text":105,"correct":22},"弹簧支架",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},890685,"给水管道的连接中，低压流体输送用（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"管径小于或等于100mm的镀锌钢管采用螺纹连接",{"key":24,"text":113,"correct":22},"球墨铸铁管采用螺纹连接",{"key":28,"text":115,"correct":22},"管径小于或等于100mm的镀锌焊接钢管采用法兰连接",{"key":31,"text":117,"correct":22},"球墨铸铁管采用法兰连接",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},890686,"在给水塑料管中，聚丙烯给水管（PP管）采用的连接方式是（ ）。",[122,124,126,127],{"key":20,"text":123,"correct":26},"热熔连接",{"key":24,"text":125,"correct":22},"承插连接",{"key":28,"text":87,"correct":22},{"key":31,"text":128,"correct":22},"橡胶圈连接",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":24,"analysis":33},890687,"排出管有室外排水管连接处的检查井，井中心距建筑物外墙不小于（ ）m。",[133,135,137,139],{"key":20,"text":134,"correct":22},"2",{"key":24,"text":136,"correct":26},"3",{"key":28,"text":138,"correct":22},"4",{"key":31,"text":140,"correct":22},"5",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":33},890688,"与其他金属管材和塑料管材相比，铸铁排水管材（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"不可再生循环利用",{"key":24,"text":148,"correct":26},"强度高",{"key":28,"text":150,"correct":22},"容易产生二次污染",{"key":31,"text":152,"correct":22},"噪声大",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":31,"analysis":33},890689,"关于塑料排水管UPVC的说法，错误的是（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"UPVC排水管物化性能优良，耐化学腐蚀，抗冲强度高",{"key":24,"text":160,"correct":22},"高层建筑中明设排水塑料管道应按设计要求设置阻火圈或防火套管",{"key":28,"text":162,"correct":22},"阻火圈由金属材料制作外壳，内填充阻燃膨胀芯材，套在硬聚氯乙烯管道外壁，固定在楼板或墙体部位",{"key":31,"text":164,"correct":26},"耐老化，使用寿命长，使用年限不低于30年",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":28,"analysis":33},890690,"热力管道采用架空敷设的特点为（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"维修、检查不方便",{"key":24,"text":172,"correct":22},"费用高、经济性很差",{"key":28,"text":174,"correct":26},"管道热损失较大",{"key":31,"text":176,"correct":22},"占地面积小",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":31,"analysis":33},890691,"热力管道敷设时，汽、水逆向流动时的坡度不得小于（ ）。",[181,183,185,187],{"key":20,"text":182,"correct":22},"2‰",{"key":24,"text":184,"correct":22},"3‰",{"key":28,"text":186,"correct":22},"4‰",{"key":31,"text":188,"correct":26},"5‰",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":31,"analysis":33},890692,"铝及铝合金管采用氧-乙炔焊时，焊前预热温度不得超过（ ）℃。",[193,195,197,199],{"key":20,"text":194,"correct":22},"100",{"key":24,"text":196,"correct":22},"160",{"key":28,"text":198,"correct":22},"180",{"key":31,"text":200,"correct":26},"200",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":33},890693,"应有代表钢种的油漆颜色和钢号、炉罐号、标准编号及制造厂的印记的高压钢管外径大于（ ）mm。",[205,207,209,211],{"key":20,"text":206,"correct":22},"25",{"key":24,"text":208,"correct":26},"35",{"key":28,"text":210,"correct":22},"40",{"key":31,"text":212,"correct":22},"50",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":31,"analysis":33},890694,"以下关于低压干式气柜的说法，错误的是（ ）。",[217,219,221,223],{"key":20,"text":218,"correct":22},"低压干式气柜的基础费用低",{"key":24,"text":220,"correct":22},"低压干式气柜运行管理和维修方便",{"key":28,"text":222,"correct":22},"低压干式气柜的寿命可长达30年",{"key":31,"text":224,"correct":26},"大容量干式气柜在技术方面优于湿式气柜，但在经济方面劣于湿式气柜",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":28,"analysis":33},890695,"（ ）制造容易，安装内件方便，承压能力较好，被广泛应用在各类项目中。",[229,231,233,235],{"key":20,"text":230,"correct":22},"球形容器",{"key":24,"text":232,"correct":22},"矩形容器",{"key":28,"text":234,"correct":26},"圆筒形容器",{"key":31,"text":236,"correct":22},"全集形容器",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":24,"analysis":33},890696,"在输送介质为热水的水平管道上，偏心异径管的连接方式应为（ ）。",[241,243,245,247],{"key":20,"text":242,"correct":22},"取管底平",{"key":24,"text":244,"correct":26},"取管顶平",{"key":28,"text":246,"correct":22},"取管左齐",{"key":31,"text":248,"correct":22},"取管右齐",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":28,"analysis":33},890697,"钛及钛合金管与其他金属管道连接时，宜采用的连接方式为（ ）。",[253,255,257,259],{"key":20,"text":254,"correct":22},"焊接连接",{"key":24,"text":256,"correct":22},"焊接法兰连接",{"key":28,"text":258,"correct":26},"活套法兰连接",{"key":31,"text":260,"correct":22},"卡套连接",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":33},890698,"在通风工程中，利用射流能量的密集，速度衰弱慢，而吸气气流衰减快的特点，有效控制有害物，进而排入排风管道系统的排风罩为（ ）。",[265,267,269,271],{"key":20,"text":266,"correct":22},"外部吸气罩",{"key":24,"text":268,"correct":26},"吹吸式排风罩",{"key":28,"text":270,"correct":22},"柜式排风罩",{"key":31,"text":272,"correct":22},"整体密闭罩",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":31,"analysis":33},890699,"在通风空调系统的无生产负荷联合试运转中，测试和调整内容除了需进行通风机风量、风压及转速测定外，还包括（ ）。",[277,279,281,283],{"key":20,"text":278,"correct":22},"通风机试运转",{"key":24,"text":280,"correct":22},"水泵试运转",{"key":28,"text":282,"correct":22},"制冷机试运转",{"key":31,"text":284,"correct":26},"通风机、制冷机、空调器的噪声测定",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":28,"analysis":33},890700,"事故通风系统中，室外排风口应布置在（ ）。",[289,291,293,295],{"key":20,"text":290,"correct":22},"有害气体散发量可能最大处",{"key":24,"text":292,"correct":22},"建筑物外端靠近事故处",{"key":28,"text":294,"correct":26},"高出20m范围内最高建筑物的屋面3m以上处",{"key":31,"text":296,"correct":22},"人员经常通行处",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":20,"analysis":33},890701,"近年来，在大型的高层民用建筑中，室内给水系统的总立管宜采用的管道为（ ）。",[301,303,305,307],{"key":20,"text":302,"correct":26},"球墨铸铁管",{"key":24,"text":304,"correct":22},"无缝钢管",{"key":28,"text":306,"correct":22},"给水硬聚氯乙烯管",{"key":31,"text":308,"correct":22},"给水聚丙烯管",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":24,"analysis":33},890702,"室内燃气管道管材选用时，正确的做法是（ ）。",[313,315,317,319],{"key":20,"text":314,"correct":22},"低压管道管径DN≤50mm时，可选用黑铁管，螺纹连接",{"key":24,"text":316,"correct":26},"低压管道管径DN＞50mm时，可采用无缝钢管，焊接或法兰连接",{"key":28,"text":318,"correct":22},"低压管道选用焊接钢管时，应采用加厚钢管",{"key":31,"text":320,"correct":22},"中压管道选用无缝钢管时，应采用螺纹连接",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":20,"analysis":33},890703,"在交通要道等振动较大的地段，埋地敷设给水承插铸铁管时，其接口形式应为（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":26},"青铅接口",{"key":24,"text":328,"correct":22},"膨胀水泥接口",{"key":28,"text":330,"correct":22},"石棉水泥接口",{"key":31,"text":332,"correct":22},"橡胶圈机械接口",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":20,"analysis":33},890704,"当设计需要安装伸缩节时，可在（ ）安装普通伸缩节。",[337,339,341,343],{"key":20,"text":338,"correct":26},"给水立管",{"key":24,"text":340,"correct":22},"给水横干管",{"key":28,"text":342,"correct":22},"排水主管",{"key":31,"text":344,"correct":22},"排水横干管",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":33},890705,"下列给排水管道的阀门中，公称压力为1.0MPa的阀门是（ ）。",[349,351,353,355],{"key":20,"text":350,"correct":22},"D741X-1.0",{"key":24,"text":352,"correct":26},"J11T-10",{"key":28,"text":354,"correct":22},"Z942M-100",{"key":31,"text":356,"correct":22},"Q21F-0.1P",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":33},890706,"室内采暖系统中，膨胀水箱连接管上不应装阀门的是（ ）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"膨胀管、循环管、信号管",{"key":24,"text":364,"correct":26},"膨胀管、循环管、溢流管",{"key":28,"text":366,"correct":22},"循环管、信号管、补水管",{"key":31,"text":368,"correct":22},"循环管、补水管、膨胀管",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":24,"analysis":33},890707,"城市燃气供应系统中，目前在中、低压两级系统使用的燃气压送设备有罗茨式鼓风机和（ ）。",[373,375,377,379],{"key":20,"text":374,"correct":22},"离心式鼓风机",{"key":24,"text":376,"correct":26},"往复式压送机",{"key":28,"text":378,"correct":22},"螺杆式压送机",{"key":31,"text":380,"correct":22},"滑片式压送机",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":31,"analysis":33},890708,"防爆等级低的防爆通风机，叶轮和机壳的制作材料应为（ ）。",[385,387,389,391],{"key":20,"text":386,"correct":22},"叶轮和机壳均用钢板",{"key":24,"text":388,"correct":22},"叶轮和机壳均用铝板",{"key":28,"text":390,"correct":22},"叶轮用钢板、机壳用铝板",{"key":31,"text":392,"correct":26},"叶轮用铝板、机壳用钢板",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":31,"analysis":33},890709,"某种通风机具有可逆转特性，在重量或功率相同的情况下，能提供较大的通风量和较高的风压，可用于铁路、公路隧道的通风换气，该风机为（ ）。",[397,399,401,403],{"key":20,"text":398,"correct":22},"离心式通风机",{"key":24,"text":400,"correct":22},"普通轴流式通风机",{"key":28,"text":402,"correct":22},"贯流式通风机",{"key":31,"text":404,"correct":26},"射流式通风机",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":28,"analysis":33},890710,"从技术和经济角度考虑，在人行频繁、非机动车辆通行的地方敷设热力管道，宜采用的敷设方式为（ ）。",[409,411,413,415],{"key":20,"text":410,"correct":22},"地面敷设",{"key":24,"text":412,"correct":22},"低支架敷设",{"key":28,"text":414,"correct":26},"中支架敷设",{"key":31,"text":416,"correct":22},"高支架敷设",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":24,"analysis":33},890711,"热力管道的安装，水平管道变径时应采用偏心异径管连接。当输送介质为蒸汽时，其安装要求为（ ）。",[421,422,423,425],{"key":20,"text":244,"correct":22},{"key":24,"text":242,"correct":26},{"key":28,"text":424,"correct":22},"取管左侧平",{"key":31,"text":426,"correct":22},"取管右侧平",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":33},890712,"合金钢管道焊接时，为确保焊口管道内壁焊肉饱满、平整等，其底层的焊接方法应为（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":26},"手工氩弧焊",{"key":24,"text":434,"correct":22},"手工电弧焊",{"key":28,"text":436,"correct":22},"熔化极氩弧焊",{"key":31,"text":438,"correct":22},"埋弧焊",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":31,"analysis":33},890713,"不锈钢用等离子切割机加工坡V1后，应对其坡V1处进行处理的方法是（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":22},"低热退火",{"key":24,"text":446,"correct":22},"高温回火",{"key":28,"text":448,"correct":22},"酸洗及钝化",{"key":31,"text":450,"correct":26},"打磨掉表面热影响层",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":20,"analysis":33},890714,"高压钢管焊接完成后，为保证焊接质量，应对焊缝进行检查和探伤。若用超声波探伤，应检查焊口数量的比例为（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":26},"100%",{"key":24,"text":458,"correct":22},"80%",{"key":28,"text":460,"correct":22},"50%",{"key":31,"text":462,"correct":22},"20%",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":24,"analysis":33},890715,"传热面积大，传热效果好，结构简单，制造的材料范围广，在高温高压的大型装置上采用较多的换热器为（ ）换热器。",[467,469,471,473],{"key":20,"text":468,"correct":22},"夹套式",{"key":24,"text":470,"correct":26},"列管式",{"key":28,"text":472,"correct":22},"套管式",{"key":31,"text":474,"correct":22},"蛇管式",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":20,"analysis":33},890716,"水泵的选择取决于室内用水的均匀程度，当一天用水量大且均匀时，由于这种工况下用水与送水曲线相近，可选用（ ）。",[479,481,483,485],{"key":20,"text":480,"correct":26},"恒速水泵",{"key":24,"text":482,"correct":22},"自动显示水泵",{"key":28,"text":484,"correct":22},"变频调速水泵",{"key":31,"text":486,"correct":22},"循环水泵",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":20,"analysis":33},890717,"高层建筑的加压泵房内不宜采用（ ）。",[491,493,495,497],{"key":20,"text":492,"correct":26},"UPVC管",{"key":24,"text":494,"correct":22},"PP管",{"key":28,"text":496,"correct":22},"PE-X管",{"key":31,"text":498,"correct":22},"PB管",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":31,"analysis":33},890718,"用于规模较大的供暖或空调水系统的水力平衡是（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"关断阀",{"key":24,"text":506,"correct":22},"调节阀",{"key":28,"text":508,"correct":22},"减压阀",{"key":31,"text":510,"correct":26},"平衡阀",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":24,"analysis":33},890719,"埋地铺设的聚乙烯管道，在长管段上通常设置（ ）。",[515,517,519,521],{"key":20,"text":516,"correct":22},"球形补偿器",{"key":24,"text":518,"correct":26},"套筒式补偿器",{"key":28,"text":520,"correct":22},"填料式补偿器",{"key":31,"text":522,"correct":22},"波形补偿器",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":31,"analysis":33},890720,"对室内空气的温度、湿度、清洁度、气流速度无严格要求的场合应优先考虑的通风方式为（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":22},"全面通风",{"key":24,"text":530,"correct":22},"局部通风",{"key":28,"text":532,"correct":22},"机械通风",{"key":31,"text":534,"correct":26},"自然通风",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":28,"analysis":33},890721,"下列关于压缩空气管道的敷设和安装的要求中，不正确的是（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"架空敷设高度不小于2.5m",{"key":24,"text":542,"correct":22},"材质选用无缝钢管",{"key":28,"text":544,"correct":26},"煨弯弯曲半径一般为3D",{"key":31,"text":546,"correct":22},"进行强度和严密性试验的介质为水",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":28,"analysis":33},890722,"变压器试运行时，一般应先进行（ ）次空载全电压冲击。",[551,552,553,554],{"key":20,"text":136,"correct":22},{"key":24,"text":138,"correct":22},{"key":28,"text":140,"correct":26},{"key":31,"text":555,"correct":22},"6",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":24,"analysis":33},890723,"当设计无要求时，控制电缆的支架层间最小距离是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"100mm",{"key":24,"text":563,"correct":26},"120mm",{"key":28,"text":565,"correct":22},"150mm",{"key":31,"text":567,"correct":22},"200mm",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":28,"analysis":33},890724,"需用于频繁操作及有易燃易爆危险的场所，要求加工精度高，对其密封性能要求严的高压断路器，应选用（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"多油断路器",{"key":24,"text":575,"correct":22},"少油断路器",{"key":28,"text":577,"correct":26},"六氟化硫断路器",{"key":31,"text":579,"correct":22},"空气断路器",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":31,"analysis":33},890725,"下列建筑电气系统中，属于弱电系统的是（ ）。",[584,586,588,590],{"key":20,"text":585,"correct":22},"电气照明",{"key":24,"text":587,"correct":22},"供电干线",{"key":28,"text":589,"correct":22},"变配电室",{"key":31,"text":591,"correct":26},"综合布线系统",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":20,"analysis":33},890726,"高压电器中常用的六氟化硫属于（ ）绝缘材料。",[596,598,600,602],{"key":20,"text":597,"correct":26},"气体",{"key":24,"text":599,"correct":22},"液体",{"key":28,"text":601,"correct":22},"固体",{"key":31,"text":603,"correct":22},"流体",{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":24,"analysis":33},890727,"电气工程预埋件的埋设方法取决于（ ）。",[608,610,612,614],{"key":20,"text":609,"correct":22},"预埋件类型",{"key":24,"text":611,"correct":26},"土建结构类型",{"key":28,"text":613,"correct":22},"电气装置类型",{"key":31,"text":615,"correct":22},"预埋件位置",[617,620,623,626,629,632],{"id":15,"name":618,"category":7,"favorite":619},"领导干部任职前廉政法规知识测试题",92,{"id":621,"name":622,"category":7,"favorite":15},595,"建筑结构与设备",{"id":624,"name":625,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":627,"name":628,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":630,"name":631,"category":7,"favorite":8},534,"BIM工程师",{"id":633,"name":631,"category":7,"favorite":8},535]