[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-577-24":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":670},{"id":5,"name":6,"category":7,"favorite":8},577,"[安装工程]建设工程计量与计价实务","建筑工程",0,24,50,1537,[13,38,53,68,80,92,104,117,130,142,155,167,180,192,205,218,230,242,254,266,278,290,302,314,326,339,354,368,382,397,411,426,440,454,469,483,497,509,523,530,542,556,567,579,591,603,617,629,643,657],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},891684,2,"多选题","起重量特性曲线考虑的因素包括（ ）。",[19,23,26,29,33],{"key":20,"text":21,"correct":22},"A","起重机的整体抗倾覆能力",true,{"key":24,"text":25,"correct":22},"B","各种机构的承载能力",{"key":27,"text":28,"correct":22},"C","起重臂的稳定性",{"key":30,"text":31,"correct":32},"D","起重机的起重臂长度",false,{"key":34,"text":35,"correct":32},"E","吊具的质量","ABC","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},891685,"关于流动式起重机的特曲线，下列说法正确的有（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"规定起重机在各种工作状态下允许吊装载荷的曲线，称为起重量特性曲线",{"key":24,"text":45,"correct":22},"反映了流动式起重机的最大起升高度随臂长、幅度变化而变化的规律",{"key":27,"text":47,"correct":32},"每台起重机都有其自身的特性曲线，在一定条件下型号相同的可以换用",{"key":30,"text":49,"correct":22},"一般应根据已确定的工作幅度、臂长，由特性曲线确定起重机能够吊装的载荷",{"key":34,"text":51,"correct":32},"在计算起重机载荷时，不应计入吊钩和索、吊具的质量","ABD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},891686,"对于焊接连接的调节阀、节流阀等，管道吹扫时应采取的保护措施包括（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":32},"与吹扫系统隔离",{"key":24,"text":60,"correct":22},"流经旁路",{"key":27,"text":62,"correct":22},"卸掉阀头及阀座",{"key":30,"text":64,"correct":32},"设置禁区",{"key":34,"text":66,"correct":32},"清洗干净相关工具","BC",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":52,"analysis":37},891687,"与等离子弧焊相比，钨极惰性气体保护焊的主要缺点有（）。",[72,74,76,78],{"key":20,"text":73,"correct":22},"仅适用于薄板及超薄板材的焊接",{"key":24,"text":75,"correct":22},"熔深浅，熔敷速度小，生产效率较低",{"key":27,"text":77,"correct":32},"是一种不熔化极的电弧焊",{"key":30,"text":79,"correct":22},"不适宜野外作业",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":52,"analysis":37},891688,"喷水灭火系统中，自动喷水预作用系统的特点有（ ）",[84,86,88,90],{"key":20,"text":85,"correct":22},"具有湿式系统和干式系统的特点",{"key":24,"text":87,"correct":22},"火灾发生时作用时间快、不延迟",{"key":27,"text":89,"correct":32},"系统组成较简单，无需充气设备",{"key":30,"text":91,"correct":22},"适用于不允许有水渍损失的场所",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":36,"analysis":37},891689,"油水分离器的类型有（ ）",[96,98,100,102],{"key":20,"text":97,"correct":22},"环形回转式",{"key":24,"text":99,"correct":22},"撞击折回式",{"key":27,"text":101,"correct":22},"离心旋转式",{"key":30,"text":103,"correct":32},"重力分离式",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":116,"analysis":37},891690,"有保护功能的继电器（ ）",[108,110,112,114],{"key":20,"text":109,"correct":32},"时间继电器",{"key":24,"text":111,"correct":32},"中间继电器",{"key":27,"text":113,"correct":22},"热继电器",{"key":30,"text":115,"correct":22},"电压继电器","CD",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":129,"analysis":37},891691,"配管符合要求的有（ ）。",[121,123,125,127],{"key":20,"text":122,"correct":32},"暗配的镀锌钢导管与盒箱可采用焊接连接",{"key":24,"text":124,"correct":22},"明配的钢导管与盒箱连接应采用螺纹连接",{"key":27,"text":126,"correct":22},"钢导管接到设备接线盒内，与用电设备直接连接",{"key":30,"text":128,"correct":22},"钢导管经柔性导管过渡到用电设备接线盒间接连接","BCD",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":116,"analysis":37},891692,"可用于大断面风管的风阀有（ ）",[134,136,138,140],{"key":20,"text":135,"correct":32},"蝶式调节阀",{"key":24,"text":137,"correct":32},"菱形单叶调节阀",{"key":27,"text":139,"correct":22},"菱形多叶调节阀",{"key":30,"text":141,"correct":22},"平行式多叶调节阀",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":154,"analysis":37},891693,"对于不允许中断供汽的热力管道敷设形式可采用（）。",[146,148,150,152],{"key":20,"text":147,"correct":32},"枝状管网",{"key":24,"text":149,"correct":22},"复线枝状管网",{"key":27,"text":151,"correct":32},"放射状管网",{"key":30,"text":153,"correct":22},"环状管网","BD",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":52,"analysis":37},891694,"集散控制系统中，被控设备现场的计算机系统控制完成的任务包括（ ）",[159,161,163,165],{"key":20,"text":160,"correct":22},"被控设备的监视",{"key":24,"text":162,"correct":22},"对被控设备的测量",{"key":27,"text":164,"correct":32},"对相关数据的打印",{"key":30,"text":166,"correct":22},"对被控设备的控制",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":179,"analysis":37},891695,"按入侵探测器防范的范围划分，属于点型入侵探测器的是（ ）。",[171,173,175,177],{"key":20,"text":172,"correct":22},"开关入侵探测器",{"key":24,"text":174,"correct":22},"振动入侵探测器",{"key":27,"text":176,"correct":32},"声入侵探测器",{"key":30,"text":178,"correct":32},"激光入侵探测器","AB",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":129,"analysis":37},891696,"闭路监控系统信号传输距离较远时，应采用的传输方式为（ ）。",[184,186,188,190],{"key":20,"text":185,"correct":32},"基带传输",{"key":24,"text":187,"correct":22},"射频传输",{"key":27,"text":189,"correct":22},"微波传输",{"key":30,"text":191,"correct":22},"光纤传输",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":204,"analysis":37},891697,"按照作用原理分类，泵可分为动力式泵、容积式泵及其他类型泵。下列属于动力式泵的有（ ）",[196,198,200,202],{"key":20,"text":197,"correct":22},"轴流泵",{"key":24,"text":199,"correct":32},"转子泵",{"key":27,"text":201,"correct":22},"旋涡泵",{"key":30,"text":203,"correct":32},"齿轮泵","AC",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":217,"analysis":37},891699,"有防锈要求的脱脂件经脱脂处理后，宜采取的保护措施有（）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"充氮封存",{"key":24,"text":212,"correct":32},"固相防锈纸密封",{"key":27,"text":214,"correct":22},"气相防锈密封",{"key":30,"text":216,"correct":22},"气相防锈塑料薄膜密封","ACD",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":67,"analysis":37},891700,"经酸洗后的设备和管道内壁要进行钝化，钝化时应遵循的规定有（）。",[222,224,226,228],{"key":20,"text":223,"correct":32},"酸洗后的设备和管道，应在两周内钝化",{"key":24,"text":225,"correct":22},"钝化液通常采用亚硝酸钠溶液",{"key":27,"text":227,"correct":22},"钝化结束后，要用偏碱的水冲洗",{"key":30,"text":229,"correct":32},"钝化时不得采用流动清洗法",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":36,"analysis":37},891701,"大型机械的润滑油、密封油等管道系统进行油清洗时，应遵循的规定有（）。",[234,236,238,240],{"key":20,"text":235,"correct":22},"系统酸洗合格后，试运转前进行油清洗",{"key":24,"text":237,"correct":22},"不锈钢油管道系统宜采用蒸汽吹净后，再进行油清洗",{"key":27,"text":239,"correct":22},"酸洗钝化或蒸汽吹扫合格后，应在两周内进行油清洗",{"key":30,"text":241,"correct":32},"油清洗合格的管道，应脱脂后进行封闭保护",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":67,"analysis":37},891702,"涂料涂覆工艺中的电泳涂装的主要特点有（）。",[246,248,250,252],{"key":20,"text":247,"correct":32},"使用水溶性涂料和油溶性涂料",{"key":24,"text":249,"correct":22},"涂装效率高，涂料损失小",{"key":27,"text":251,"correct":22},"涂膜厚度均匀，附着力强",{"key":30,"text":253,"correct":32},"不适用复杂形状工件的涂装",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":67,"analysis":37},891703,"在各种自动控制系统温度测量仪表中，能够进行高温测量的温度检测仪表有（）。",[258,260,262,264],{"key":20,"text":259,"correct":32},"外标式玻璃温度计",{"key":24,"text":261,"correct":22},"薄膜型热电偶温度计",{"key":27,"text":263,"correct":22},"半导体热敏电阻温度计",{"key":30,"text":265,"correct":32},"压力式温度计",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":116,"analysis":37},891704,"属于差压式流量检测仪表的有（）。",[270,272,274,276],{"key":20,"text":271,"correct":32},"玻璃管转子流量计",{"key":24,"text":273,"correct":32},"涡轮流量计",{"key":27,"text":275,"correct":22},"节流装置流量计",{"key":30,"text":277,"correct":22},"均速管流量计",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":204,"analysis":37},891705,"选用卷扬机的主要参数有（）。",[282,284,286,288],{"key":20,"text":283,"correct":22},"额定牵引拉力",{"key":24,"text":285,"correct":32},"功率",{"key":27,"text":287,"correct":22},"卷筒容绳量",{"key":30,"text":289,"correct":32},"速比",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":217,"analysis":37},891706,"无损检测时，关于射线探伤特点的正确表示为（）。",[294,296,298,300],{"key":20,"text":295,"correct":22},"X射线照射时间短，速度快",{"key":24,"text":297,"correct":32},"Y射线穿透能力比X射线强，灵敏度高",{"key":27,"text":299,"correct":22},"Y射线投资少，成本低，施工现场使用方便",{"key":30,"text":301,"correct":22},"中子射线检测能够检测封闭在高密度金属材料中的低密度非金属材料",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":36,"analysis":37},891707,"埋弧焊是工业生产中常用的焊接方法，其主要优点有（）。",[306,308,310,312],{"key":20,"text":307,"correct":22},"热效率较高，工件坡口可较小",{"key":24,"text":309,"correct":22},"焊接速度快，生产效率高",{"key":27,"text":311,"correct":22},"焊接中产生气孔、裂缝的可能性较小",{"key":30,"text":313,"correct":32},"适用于各种厚度板材的焊接",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":217,"analysis":37},891708,"燃气输配系统是一个综合设施，其组成除包括燃气输配管网、储配站外，还有（ ）。",[318,320,322,324],{"key":20,"text":319,"correct":22},"调压计量站",{"key":24,"text":321,"correct":32},"恒流计量站",{"key":27,"text":323,"correct":22},"运行监控系统",{"key":30,"text":325,"correct":22},"数据采集系统",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":338,"analysis":37},891709,"活塞式压缩机的性能特点有（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"速度低，损失小",{"key":24,"text":333,"correct":32},"小流量，超高压范围内不适用",{"key":27,"text":335,"correct":32},"旋转零部件采用高强度合金钢",{"key":30,"text":337,"correct":22},"外形尺寸大，重量大，结构复杂","AD",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":353,"analysis":37},891710,"关于施工方案交底说法正确的是（）。",[343,345,347,349,351],{"key":20,"text":344,"correct":22},"“四新”项目交底",{"key":24,"text":346,"correct":32},"指导工程施工管理的综合性文件",{"key":27,"text":348,"correct":22},"特殊环境、特种作业交底",{"key":30,"text":350,"correct":32},"总包的编制人员应向施工作业人员",{"key":34,"text":352,"correct":22},"交底内容应包括质量控制、安全措施","ACE",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":129,"analysis":37},891711,"某工程双代号网络图如下图所示，绘图错误有 ( )",[358,360,362,364,366],{"key":20,"text":359,"correct":32},"多个起点节点",{"key":24,"text":361,"correct":22},"存在循环回路",{"key":27,"text":363,"correct":22},"节点编号有误",{"key":30,"text":365,"correct":22},"多个终点节点",{"key":34,"text":367,"correct":32},"有无箭头的连线",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":353,"analysis":37},891712,"加快的成倍节拍流水施工的特点有( )。",[372,374,376,378,380],{"key":20,"text":373,"correct":22},"同一施工过程在各个施工段上的流水节拍均相等",{"key":24,"text":375,"correct":32},"相邻施工过程的流水步距等于流水节拍",{"key":27,"text":377,"correct":22},"各个专业工作队在施工段上能够连续作业",{"key":30,"text":379,"correct":32},"每个施工过程均成立一个专业工作队",{"key":34,"text":381,"correct":22},"所有施工段充分利用且没有空闲时间",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":396,"analysis":37},891713,"建设工程组织固定节拍流水施工的特点有( )",[386,388,390,392,394],{"key":20,"text":387,"correct":32},"施工过程在各施工段上的流水节拍不尽相等",{"key":24,"text":389,"correct":22},"各专业工作队在各施工段上能够连续作业",{"key":27,"text":391,"correct":22},"相邻施工过程之间的流水步距相等",{"key":30,"text":393,"correct":32},"专业工作队数大于施工过程数",{"key":34,"text":395,"correct":22},"各施工段之间没有空闲时间","BCE",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":217,"analysis":37},891714,"施工组织设计的类型按编制对象范围的分类包括（ ）。",[401,403,405,407,409],{"key":20,"text":402,"correct":22},"施工组织总设计",{"key":24,"text":404,"correct":32},"单位工程施工总设计",{"key":27,"text":406,"correct":22},"单位工程施工组织设计",{"key":30,"text":408,"correct":22},"分部分项工程施工组织设计",{"key":34,"text":410,"correct":32},"分部分项工程施工总设计",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":425,"analysis":37},891715,"施工部署根据建设项目的性质、规模和客观条件的不同而有所不同，其具体表现有（ ）。",[415,417,419,421,423],{"key":20,"text":416,"correct":22},"确定项目施工目标",{"key":24,"text":418,"correct":22},"确定项目分阶段（期）交付的计划",{"key":27,"text":420,"correct":32},"建立项目环境管理的组织机构并明确职责",{"key":30,"text":422,"correct":22},"确定项目分阶段（期）施工的合理顺序及空间组织",{"key":34,"text":424,"correct":22},"对主要分包项目施工单位的资质和能力提出明确要求","ABDE",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":439,"analysis":37},891716,"环境管理计划的内容包括（ ）。",[430,432,434,435,437],{"key":20,"text":431,"correct":32},"根据项目施工预算，制订项目施工成本目标",{"key":24,"text":433,"correct":22},"确定项目重要环境因素，制订项目环境管理目标",{"key":27,"text":420,"correct":22},{"key":30,"text":436,"correct":22},"根据项目特点进行环境保护方面的资源配置",{"key":34,"text":438,"correct":22},"制订现场环境保护的控制措施","BCDE",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":425,"analysis":37},891717,"施工平面图的设计依据编制施工平面图时可参考的依据有（ ）。",[444,446,448,450,452],{"key":20,"text":445,"correct":22},"建筑总平面图",{"key":24,"text":447,"correct":22},"地形地貌图",{"key":27,"text":449,"correct":32},"施工现场周围的环境",{"key":30,"text":451,"correct":22},"区域规划图",{"key":34,"text":453,"correct":22},"建设地区的自然条件和技术经济条件",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":468,"analysis":37},891718,"施工现场平面图在布置时应当遵循的原则包括（ ）。",[458,460,462,464,466],{"key":20,"text":459,"correct":22},"施工平面布置应紧凑合理，尽量减少施工用地",{"key":24,"text":461,"correct":32},"可能开拓新的施工用地",{"key":27,"text":463,"correct":22},"尽量采用装配式施工设施",{"key":30,"text":465,"correct":22},"保证现场运输道路合理、通畅",{"key":34,"text":467,"correct":22},"各种施工设施、堆场、加工厂等的布置应便于施工活动","ACDE",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":425,"analysis":37},891719,"下列选项，属于施工组织设计编制依据的有（ ）。",[473,475,477,479,481],{"key":20,"text":474,"correct":22},"工程建设有关法律法规及政策",{"key":24,"text":476,"correct":22},"工程建设标准和技术经济指标",{"key":27,"text":478,"correct":32},"项目施工目标",{"key":30,"text":480,"correct":22},"工程施工合同文件",{"key":34,"text":482,"correct":22},"与工程有关的资源供应条件",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":217,"analysis":37},891720,"定量分析常采用的指标包括（ ）。",[487,489,491,493,495],{"key":20,"text":488,"correct":22},"工期指标",{"key":24,"text":490,"correct":32},"工时指标",{"key":27,"text":492,"correct":22},"劳动量消耗指标",{"key":30,"text":494,"correct":22},"主要材料消耗指标",{"key":34,"text":496,"correct":32},"工作量指标",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":439,"analysis":37},891721,"下列哪些选项属于施工平面图应标明的内容？（ ）",[501,502,504,506,508],{"key":20,"text":453,"correct":32},{"key":24,"text":503,"correct":22},"起重机轨道和开行路线以及垂直运输设施的位置",{"key":27,"text":505,"correct":22},"材料、加工半成品、构件和机具堆场",{"key":30,"text":507,"correct":22},"场内外交通布置",{"key":34,"text":449,"correct":22},{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":116,"analysis":37},891766,"电气配管配线工程中，半硬质阻燃管的使用特点包括（ ）。",[513,515,517,519,521],{"key":20,"text":514,"correct":32},"耐腐蚀性较好，可用于腐蚀性较大的场所",{"key":24,"text":516,"correct":32},"机械强度较好，适用于有机械外力的场所",{"key":27,"text":518,"correct":22},"劳动强度较低，易于施工",{"key":30,"text":520,"correct":22},"广泛用于民用建筑暗配管",{"key":34,"text":522,"correct":32},"运输比较麻烦",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":525,"answer":338,"analysis":37},891767,[526,527,528,529],{"key":20,"text":331,"correct":22},{"key":24,"text":333,"correct":32},{"key":27,"text":335,"correct":32},{"key":30,"text":337,"correct":22},{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":67,"analysis":37},891768,"对于提升倾角较大的散装固体物料，其使用的输送设备有（ ）。",[534,536,538,540],{"key":20,"text":535,"correct":32},"振动输送机",{"key":24,"text":537,"correct":22},"斗式输送机",{"key":27,"text":539,"correct":22},"斗式提升机",{"key":30,"text":541,"correct":32},"带式输送机",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":129,"analysis":37},891769,"下列各项属于锅炉的安全附件的有（ ）。",[546,548,550,552,554],{"key":20,"text":547,"correct":32},"空气预热器",{"key":24,"text":549,"correct":22},"水位计",{"key":27,"text":551,"correct":22},"安全阀",{"key":30,"text":553,"correct":22},"压力表",{"key":34,"text":555,"correct":32},"电源",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":36,"analysis":37},891770,"锅炉的汽、水压力系统及其附属设备安装完毕后，必须进行水压试验，进行水压试验的组成部分有（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"锅筒",{"key":24,"text":563,"correct":22},"联箱",{"key":27,"text":565,"correct":22},"过热器",{"key":30,"text":547,"correct":32},{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":179,"analysis":37},891771,"消防水池设置正确的为（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":22},"生产生活用水达最大，市政不能满足",{"key":24,"text":574,"correct":22},"只有一条引入管，室外消火栓设计流量大于20L\u002Fs",{"key":27,"text":576,"correct":32},"只有一路消防供水，建筑高于80m",{"key":30,"text":578,"correct":32},"两路供水，消防水池有效容积不应小于40m3",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":36,"analysis":37},891772,"目前在我国生产的泡沫灭火系统中，所用泡沫比例混合器的形式有（ ）。",[583,585,587,589],{"key":20,"text":584,"correct":22},"环泵式",{"key":24,"text":586,"correct":22},"管线式",{"key":27,"text":588,"correct":22},"压力式",{"key":30,"text":590,"correct":32},"不平衡压力式",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":217,"analysis":37},891773,"在低压电气设备中，按结构及工作原理分类，感应电动机可分为（ ）。",[595,597,599,601],{"key":20,"text":596,"correct":22},"单相异步电动机",{"key":24,"text":598,"correct":32},"两相异步电动机",{"key":27,"text":600,"correct":22},"三相异步电动机",{"key":30,"text":602,"correct":22},"罩极异步电动机",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":52,"analysis":37},891774,"室内消火栓给水系统的给水方式有（ ）。",[607,609,611,613,615],{"key":20,"text":608,"correct":22},"无水泵和水箱",{"key":24,"text":610,"correct":22},"设消防水泵和水箱",{"key":27,"text":612,"correct":32},"不设水箱",{"key":30,"text":614,"correct":22},"区域集中",{"key":34,"text":616,"correct":32},"有水泵",{"id":618,"libraryId":5,"type":15,"typeLabel":16,"stem":619,"options":620,"answer":217,"analysis":37},891775,"在气柜总体实验中，进行气柜的气密性试验和快速升降试验的目的是检查（ ）。",[621,623,625,627],{"key":20,"text":622,"correct":22},"各中节、钟罩在升降时的性能",{"key":24,"text":624,"correct":32},"气柜壁板焊缝的焊接质量",{"key":27,"text":626,"correct":22},"各导轮、导轨、配合及工作情况",{"key":30,"text":628,"correct":22},"整体气柜密封性能",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":67,"analysis":37},891776,"室内采暖管道常采用的管道有（ ）。",[633,635,637,639,641],{"key":20,"text":634,"correct":32},"交联聚乙烯管",{"key":24,"text":636,"correct":22},"镀锌钢管",{"key":27,"text":638,"correct":22},"普通焊接钢管",{"key":30,"text":640,"correct":32},"钢板卷焊管",{"key":34,"text":642,"correct":32},"无缝钢管",{"id":644,"libraryId":5,"type":15,"typeLabel":16,"stem":645,"options":646,"answer":338,"analysis":37},891777,"空调用冷却塔常见的有（ ）。",[647,649,651,653,655],{"key":20,"text":648,"correct":22},"逆流式",{"key":24,"text":650,"correct":32},"顺流式",{"key":27,"text":652,"correct":32},"纵流式",{"key":30,"text":654,"correct":22},"横流式",{"key":34,"text":656,"correct":32},"倒流式",{"id":658,"libraryId":5,"type":15,"typeLabel":16,"stem":659,"options":660,"answer":217,"analysis":37},891778,"在风阀中只有控制功能的有（ ）。",[661,663,665,667,669],{"key":20,"text":662,"correct":22},"止回阀",{"key":24,"text":664,"correct":32},"插板阀",{"key":27,"text":666,"correct":22},"防火阀",{"key":30,"text":668,"correct":22},"排烟阀",{"key":34,"text":135,"correct":32},[671,675,678,681,684,687],{"id":672,"name":673,"category":7,"favorite":674},1,"领导干部任职前廉政法规知识测试题",92,{"id":676,"name":677,"category":7,"favorite":672},595,"建筑结构与设备",{"id":679,"name":680,"category":7,"favorite":672},715,"招标采购专业知识与法律法规",{"id":682,"name":683,"category":7,"favorite":672},848,"市政方向-通用基础",{"id":685,"name":686,"category":7,"favorite":8},534,"BIM工程师",{"id":688,"name":686,"category":7,"favorite":8},535]