[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-577-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":603},{"id":5,"name":6,"category":7,"favorite":8},577,"[安装工程]建设工程计量与计价实务","建筑工程",0,20,50,1537,[13,34,46,58,70,82,94,105,117,129,141,153,165,177,187,199,210,222,234,246,258,270,282,290,302,314,326,338,350,362,374,386,396,408,420,432,442,454,466,478,488,500,512,524,534,546,558,567,579,591],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},891472,1,"单选题","下列管道中，室内外界线以地下引入室内的管道以室内第一个阀门为界的管道是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","采暖管道",false,{"key":24,"text":25,"correct":22},"B","空调水管道",{"key":27,"text":28,"correct":22},"C","给排水管道",{"key":30,"text":31,"correct":32},"D","燃气管道",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},891473,"设置于封闭管廊、管道井内的管道、阀门、法兰和支架安装，人工乘以系数（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"1.1",{"key":24,"text":41,"correct":32},"1.2",{"key":27,"text":43,"correct":22},"1.02",{"key":30,"text":45,"correct":22},"1.22",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":30,"analysis":33},891474,"排出管与室外排水管连接处设置检查井。一般检查井中心至建筑物外墙的距离不小于（ ）m，不大于（ ）m。",[50,52,54,56],{"key":20,"text":51,"correct":22},"3，5",{"key":24,"text":53,"correct":22},"5，10",{"key":27,"text":55,"correct":22},"10，15",{"key":30,"text":57,"correct":32},"3，10",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},891475,"下列选项中，不属于室内给排水平面图应表达的主要内容（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"轴线及编号，门.窗位置，房间尺寸及地面标高",{"key":24,"text":65,"correct":22},"给排水主管位置及编号，横支管平面位置.走向.坡度.管径及管长等",{"key":27,"text":67,"correct":32},"表明它的位置及相互关系.管径.坡度及坡向.标髙等",{"key":30,"text":69,"correct":22},"卫生洁具及用水设备的定位尺寸及朝向",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},891476,"根据管道工程系统安装的通用工艺流程，首先要进行的工作是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"预制加工",{"key":24,"text":77,"correct":32},"安装准备",{"key":27,"text":79,"correct":22},"定位放线",{"key":30,"text":81,"correct":22},"干管安装",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},891477,"给水系统交付使用前必须进行（ ）并做好记录。",[86,88,90,92],{"key":20,"text":87,"correct":22},"强度试验",{"key":24,"text":89,"correct":22},"严密性试验",{"key":27,"text":91,"correct":22},"灌水试验",{"key":30,"text":93,"correct":32},"通水试验",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},891478,"在连接（ ）卫生器具的污水横管上应设置清扫口。",[98,100,102,103],{"key":20,"text":99,"correct":22},"2个及2以上",{"key":24,"text":101,"correct":32},"3个及3以上",{"key":27,"text":101,"correct":22},{"key":30,"text":104,"correct":22},"4个及4以上",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":24,"analysis":33},891479,"在无冰冻地区，室外给水系统中埋地敷设时，管顶的覆土厚度不得小于（ ）m。",[109,111,113,115],{"key":20,"text":110,"correct":22},"0.3",{"key":24,"text":112,"correct":32},"0.5",{"key":27,"text":114,"correct":22},"0.7",{"key":30,"text":116,"correct":22},"1.0",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":30,"analysis":33},891480,"下列不属于给水管道按水平干管敷设位置布置形式的是（ ）。",[121,123,125,127],{"key":20,"text":122,"correct":22},"下行上给式",{"key":24,"text":124,"correct":22},"上行下给式",{"key":27,"text":126,"correct":22},"中分式",{"key":30,"text":128,"correct":32},"分区供水式",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":24,"analysis":33},891481,"给水硬聚氯乙烯管（UPV C），输送水的温度不超过（ ）℃。",[133,135,137,139],{"key":20,"text":134,"correct":22},"30",{"key":24,"text":136,"correct":32},"45",{"key":27,"text":138,"correct":22},"60",{"key":30,"text":140,"correct":22},"100",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":30,"analysis":33},891482,"当管径小于或等于50mm时，宜采用的阀门是（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"闸阀和蝶阀",{"key":24,"text":148,"correct":22},"闸阀和快开阀",{"key":27,"text":150,"correct":22},"蝶阀和球阀",{"key":30,"text":152,"correct":32},"闸阀和球阀",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":27,"analysis":33},891483,"排水系统中，立管上检查口之间的距离不大（ ）m。",[157,159,161,163],{"key":20,"text":158,"correct":22},"3",{"key":24,"text":160,"correct":22},"5",{"key":27,"text":162,"correct":32},"10",{"key":30,"text":164,"correct":22},"12",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":27,"analysis":33},891484,"关于承压管道系统的管道的说法错误的是（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"管道在安装完毕.压力试验前应进行吹扫",{"key":24,"text":172,"correct":22},"管道必须按规定进行强度和严密性试验",{"key":27,"text":174,"correct":32},"燃气管道试验介质宜采用水，严禁用空气",{"key":30,"text":176,"correct":22},"管道上使用冲压弯头时，所使用的冲压弯头外径应与管外径相同",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":33},891485,"关于承压管道系统的管道的说法正确的是（ ）。",[181,183,184,185],{"key":20,"text":182,"correct":22},"管道在安装完毕.压力试验后应进行吹扫",{"key":24,"text":172,"correct":32},{"key":27,"text":174,"correct":22},{"key":30,"text":186,"correct":22},"管道上使用冲压弯头时，所使用的冲压弯头外径应与管内径相同",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":27,"analysis":33},891486,"燃气管道应喷涂（刷）识别漆，一般采用（ ）防腐漆。",[191,193,195,197],{"key":20,"text":192,"correct":22},"蓝色",{"key":24,"text":194,"correct":22},"红色",{"key":27,"text":196,"correct":32},"黄色",{"key":30,"text":198,"correct":22},"白色",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":20,"analysis":33},891487,"室内给水管道试验压力为工作压力的1.5倍，但是不得小于（ ）MPa。",[203,205,206,208],{"key":20,"text":204,"correct":32},"0.6",{"key":24,"text":112,"correct":22},{"key":27,"text":207,"correct":22},"1.6",{"key":30,"text":209,"correct":22},"1.5",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":27,"analysis":33},891488,"当外网的水量满足室内要求，而水压大部分时间不足时室内给水方式应采用（ ）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"单设水箱的给水方式",{"key":24,"text":217,"correct":22},"单设水泵的给水方式",{"key":27,"text":219,"correct":32},"设贮水池水泵的给水方式",{"key":30,"text":221,"correct":22},"设水泵水箱的给水方式",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":30,"analysis":33},891489,"在建筑给水系统中一般采用的泵是（ ）。",[226,228,230,232],{"key":20,"text":227,"correct":22},"旋涡泵",{"key":24,"text":229,"correct":22},"混流泵",{"key":27,"text":231,"correct":22},"轴流泵",{"key":30,"text":233,"correct":32},"离心泵",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":20,"analysis":33},891490,"近年来，在大型的高层民用建筑中，室内给水系统的总立管宜采用的管道为（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":32},"球墨铸铁管",{"key":24,"text":241,"correct":22},"无缝钢管",{"key":27,"text":243,"correct":22},"给水硬聚氯乙烯管",{"key":30,"text":245,"correct":22},"给水聚丙烯管",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":24,"analysis":33},891491,"室内给水管网上应设置阀门，下列叙述正确的是（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":22},"DN≤50mm的管道上，宜采用闸阀或蝶阀",{"key":24,"text":253,"correct":32},"DN≤50mm的管道上，宜采用闸阀或球阀",{"key":27,"text":255,"correct":22},"DN＞50mm的管道上，宜采用闸阀或球阀",{"key":30,"text":257,"correct":22},"DN＞50mm的管道上，宜采用球阀或蝶阀",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":27,"analysis":33},891492,"在连接2个及以上的大便器或3个及以上的卫生器具的污水横管上，应设（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"通气管",{"key":24,"text":265,"correct":22},"检查口",{"key":27,"text":267,"correct":32},"清扫口",{"key":30,"text":269,"correct":22},"检查井",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":20,"analysis":33},891493,"在施工及设计说明中，主要说明建筑面积、层高、楼层分部情况、给排水系统划分、用水量设计、水源进出方式和水箱设置情况的部分是（ ）。",[274,276,278,280],{"key":20,"text":275,"correct":32},"工程概况",{"key":24,"text":277,"correct":22},"管材与附件",{"key":27,"text":279,"correct":22},"管道防腐.绝热",{"key":30,"text":281,"correct":22},"管道支吊架",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":27,"analysis":33},891494,"在施工及设计说明中，主要说明给水管和排水管的刷漆要求，暗设和埋地管道的防腐要求，热回水管、外露给水管的保温、防冻材料及做法要求的部分是（ ）。",[286,287,288,289],{"key":20,"text":275,"correct":22},{"key":24,"text":277,"correct":22},{"key":27,"text":279,"correct":32},{"key":30,"text":281,"correct":22},{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":33},891495,"根据《通用安装工程工程量计算规范》（GB50856—2013）的规定，管道工程量计算不扣除阀门、管件及附属构筑物所占长度，方形补偿器以其（ ）列入管道安装工程量。",[294,296,298,300],{"key":20,"text":295,"correct":32},"所占长度",{"key":24,"text":297,"correct":22},"总长度",{"key":27,"text":299,"correct":22},"所占长度的1\u002F2",{"key":30,"text":301,"correct":22},"总长度的1\u002F2",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":30,"analysis":33},891496,"下列选项中关于刷油工程计量的说法错误的是（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":22},"管道刷油可以按设计图示表面积计算，计量单位为“m2”",{"key":24,"text":309,"correct":22},"铸铁管和暖气片刷油管道刷油可以按设计图示表面积计算，计量单位为“m2”",{"key":27,"text":311,"correct":22},"管道刷油可以按设计图示尺寸以长度计算，计量单位为“m”",{"key":30,"text":313,"correct":32},"金属结构刷油清单项目可以按设计图示尺寸以长度计算，计量单位为“m”",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":27,"analysis":33},891497,"下列选项中关于刷油工程清单应用的的说法错误的是（ ）。",[318,320,322,324],{"key":20,"text":319,"correct":22},"除锈工程不能单独编制清单项目",{"key":24,"text":321,"correct":22},"应在刷油.防腐.绝热等清单项目的综合单价中编制除锈相关费用",{"key":27,"text":323,"correct":32},"管道刷油扣除附属构筑物.管件及阀门等所占长度",{"key":30,"text":325,"correct":22},"管道刷油不扣除附属构筑物.管件及阀门等所占长度",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":30,"analysis":33},891498,"下列选项中，关于除锈工程说法错误的是（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"设备.管道除锈以m2计量",{"key":24,"text":333,"correct":22},"钢结构除锈以kg计量",{"key":27,"text":335,"correct":22},"各种管件.阀件及设备上人孔.管口凹凸部分的除锈不再单独计算其除锈工程量",{"key":30,"text":337,"correct":32},"Sa2级或Sa1级，则人工.材料和机械乘以系数1.1",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":24,"analysis":33},891499,"在通风系统中，对于污染源比较固定的地点，从经济和有效方面应优先考虑的通风方式是（ ）。",[342,344,346,348],{"key":20,"text":343,"correct":22},"局部送风",{"key":24,"text":345,"correct":32},"局部排风",{"key":27,"text":347,"correct":22},"全面通风",{"key":30,"text":349,"correct":22},"置换通风",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":30,"analysis":33},891500,"全压系数较大，效率较低，其进、出口均是矩形的，易于建筑配合，目前大量应用于空调挂机、空调扇、风幕机等设备产品的通风机为（ ）。",[354,356,358,360],{"key":20,"text":355,"correct":22},"离心式通风机",{"key":24,"text":357,"correct":22},"轴流式通风机",{"key":27,"text":359,"correct":22},"活塞式通风机",{"key":30,"text":361,"correct":32},"贯流式通风机",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":30,"analysis":33},891501,"通风系统管式消声器的消声性能为（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":22},"良好的低中频消声",{"key":24,"text":369,"correct":22},"良好的低中高频消声",{"key":27,"text":371,"correct":22},"良好的低高频消声",{"key":30,"text":373,"correct":32},"良好的中高频消声",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":24,"analysis":33},891502,"民用建筑空调制冷工程中，具有制造简单、价格低廉、运行可靠、使用灵活等优点，在民用建筑空调中占重要地位的冷水机组是（ ）。",[378,380,382,384],{"key":20,"text":379,"correct":22},"离心式冷水机组",{"key":24,"text":381,"correct":32},"活塞式冷水机组",{"key":27,"text":383,"correct":22},"螺杆式冷水机组",{"key":30,"text":385,"correct":22},"转子式冷水机组",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":24,"analysis":33},891503,"高效过滤器主要用于去除（ ）μm以下的粒子。",[390,392,393,394],{"key":20,"text":391,"correct":22},"5.0",{"key":24,"text":116,"correct":32},{"key":27,"text":112,"correct":22},{"key":30,"text":395,"correct":22},"0.1",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":30,"analysis":33},891504,"通风空调系统使用离心水泵时，泵的找平应保证卧式和立式泵的纵、横向水平度不应（ ），测量时，以加工面为基准。",[400,402,404,406],{"key":20,"text":401,"correct":22},"小于1\u002F100",{"key":24,"text":403,"correct":22},"小于1\u002F1000",{"key":27,"text":405,"correct":22},"超过1\u002F100",{"key":30,"text":407,"correct":32},"超过1\u002F1000",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":30,"analysis":33},891505,"制冷设备安装前，拆箱应（ ）顺序进行。",[412,414,416,418],{"key":20,"text":413,"correct":22},"从左到右",{"key":24,"text":415,"correct":22},"从前到后",{"key":27,"text":417,"correct":22},"自下而上",{"key":30,"text":419,"correct":32},"自上而下",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":30,"analysis":33},891506,"通风管道制作时，圆形风管的三通或四通，夹角宜为（ ）。",[424,426,428,430],{"key":20,"text":425,"correct":22},"3°",{"key":24,"text":427,"correct":22},"5°",{"key":27,"text":429,"correct":22},"10°～11°",{"key":30,"text":431,"correct":32},"15°～16°",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":33},891507,"制作风管，咬口连接适用于厚度不大于（ ）mm的碳钢板。",[436,438,439,440],{"key":20,"text":437,"correct":22},"1",{"key":24,"text":41,"correct":32},{"key":27,"text":209,"correct":22},{"key":30,"text":441,"correct":22},"1.8",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":27,"analysis":33},891508,"通风空调系统在水平管安装调节装置时，插板应（ ）安装。",[446,448,450,452],{"key":20,"text":447,"correct":22},"前端",{"key":24,"text":449,"correct":22},"末端",{"key":27,"text":451,"correct":32},"顺气流",{"key":30,"text":453,"correct":22},"逆气流",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":27,"analysis":33},891509,"根据《民用安装工程工程量计算规范》，下列项目不以“平方米”为计量单位的是（ ）。",[458,460,462,464],{"key":20,"text":459,"correct":22},"铝板通风管",{"key":24,"text":461,"correct":22},"塑料通风管",{"key":27,"text":463,"correct":32},"柔性软风管",{"key":30,"text":465,"correct":22},"不锈钢板通风管",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":27,"analysis":33},891510,"《2012安装预算定额》第七册《通风空调工程》规定，系统调试费按系统工程人工费的（ ）计算。",[470,472,474,476],{"key":20,"text":471,"correct":22},"26%",{"key":24,"text":473,"correct":22},"18%",{"key":27,"text":475,"correct":32},"13.8%",{"key":30,"text":477,"correct":22},"9.8%",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":30,"analysis":33},891511,"《2012安装预算定额》第七册《通风空调工程》规定，整个通风系统设计采用渐缩管均匀送风时，按平均直径（或大边长）执行相应定额子目，其人工乘以系数（ ）。",[482,483,484,486],{"key":20,"text":39,"correct":22},{"key":24,"text":41,"correct":22},{"key":27,"text":485,"correct":22},"1.4",{"key":30,"text":487,"correct":32},"2.5",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":24,"analysis":33},891512,"下列不属于建筑通风中风道系统的是（ ）。",[492,494,496,498],{"key":20,"text":493,"correct":22},"风管",{"key":24,"text":495,"correct":32},"风帽",{"key":27,"text":497,"correct":22},"阀部件",{"key":30,"text":499,"correct":22},"排气罩",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":24,"analysis":33},891513,"使有害物随生产过程或设备本身产生或诱导的气流直接进入罩内的局部排风罩为（ ）。",[504,506,508,510],{"key":20,"text":505,"correct":22},"吹吸式排风罩",{"key":24,"text":507,"correct":32},"接受式排风罩",{"key":27,"text":509,"correct":22},"外部吸气罩",{"key":30,"text":511,"correct":22},"密闭小室",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":27,"analysis":33},891514,"地源热系统与传统空调相比，比传统空调节能（ ）。",[516,518,520,522],{"key":20,"text":517,"correct":22},"20%～40%",{"key":24,"text":519,"correct":22},"30%～50%",{"key":27,"text":521,"correct":32},"40%～60%",{"key":30,"text":523,"correct":22},"50%～70%",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":20,"analysis":33},891515,"普通民用建筑的居住、办公室等，宜采用（ ）。",[528,530,532,533],{"key":20,"text":529,"correct":32},"自然通风",{"key":24,"text":531,"correct":22},"机械通风",{"key":27,"text":345,"correct":22},{"key":30,"text":343,"correct":22},{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":27,"analysis":33},891516,"空调换热器按（ ）分为加热器、预热器、过热器、蒸发器等。",[538,540,542,544],{"key":20,"text":539,"correct":22},"传热原理",{"key":24,"text":541,"correct":22},"结构",{"key":27,"text":543,"correct":32},"用途",{"key":30,"text":545,"correct":22},"性质",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":27,"analysis":33},891517,"空调水系统管道安装时镀锌钢管管径（ ）时，可采用卡箍、法兰或焊接连接。",[550,552,554,556],{"key":20,"text":551,"correct":22},"大于DN80",{"key":24,"text":553,"correct":22},"小于DN80",{"key":27,"text":555,"correct":32},"大于DN100",{"key":30,"text":557,"correct":22},"小于DN100",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":27,"analysis":33},891518,"制冷设备阀门有锈蚀时要做强度和严密性试验，强度试验的压力为公称压力的（ ）倍。",[562,563,564,565],{"key":20,"text":437,"correct":22},{"key":24,"text":41,"correct":22},{"key":27,"text":209,"correct":32},{"key":30,"text":566,"correct":22},"2",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":30,"analysis":33},891519,"在执行火灾自动报警系统定额项目时，下列说法不正确的是（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":22},"安装定额中箱.机是以成套装置编制的",{"key":24,"text":574,"correct":22},"短路隔离器安装执行多输入多输出模块安装定额子目",{"key":27,"text":576,"correct":22},"闪灯执行声光报警器",{"key":30,"text":578,"correct":32},"柜式执行落地式安装相应项目，琴台式不能按照落地式项目执行",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":20,"analysis":33},891520,"下列关于消防水灭火系统定额执行的注意事项，不正确的是（ ）。",[583,585,587,589],{"key":20,"text":584,"correct":32},"室外消火栓安装定额中包括法兰接管但不包括弯头（三通）的安装",{"key":24,"text":586,"correct":22},"水流指示器（马鞍形）项目的主材包括胶圈和U形卡",{"key":27,"text":588,"correct":22},"集热罩安装项目主材包括所配备的成品支架",{"key":30,"text":590,"correct":22},"消防水炮项目定额中包括主体安装不包括型钢底座制作安装",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":24,"analysis":33},891521,"消防图例中，该图标表示的是（ ）。",[595,597,599,601],{"key":20,"text":596,"correct":22},"湿式报警阀",{"key":24,"text":598,"correct":32},"干式报警阀",{"key":27,"text":600,"correct":22},"信号阀",{"key":30,"text":602,"correct":22},"防火阀",[604,607,610,613,616,619],{"id":15,"name":605,"category":7,"favorite":606},"领导干部任职前廉政法规知识测试题",92,{"id":608,"name":609,"category":7,"favorite":15},595,"建筑结构与设备",{"id":611,"name":612,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":614,"name":615,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":617,"name":618,"category":7,"favorite":8},534,"BIM工程师",{"id":620,"name":618,"category":7,"favorite":8},535]