[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-577-17":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":607},{"id":5,"name":6,"category":7,"favorite":8},577,"[安装工程]建设工程计量与计价实务","建筑工程",0,17,50,1537,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,188,196,208,220,232,244,256,268,280,291,303,314,326,338,350,362,374,386,397,408,420,432,444,456,468,480,492,502,514,526,538,550,562,574,586,598],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},891321,1,"单选题","对于防爆等级低的通风机，叶轮与机壳的制作材料为（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","叶轮用铝板，机壳用钢板",true,{"key":24,"text":25,"correct":26},"B","叶轮用钢板，机壳用铝板",false,{"key":28,"text":29,"correct":26},"C","叶轮用铝板，机壳用铝板",{"key":31,"text":32,"correct":26},"D","叶轮用钢板，机壳用钢板","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},891322,"主要用于小断面风管调节风量的风阀是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"蝶式调节阀",{"key":24,"text":41,"correct":26},"三通调节阀",{"key":28,"text":43,"correct":26},"菱形多叶调节阀",{"key":31,"text":45,"correct":26},"复式多叶调节阀",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},891323,"空调系统中常用的送风口，具有均匀散流特性及简洁美观的外形，可根据使用要求制成正方形或长方形，能配合任何天花板的装修要求，这种风口是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"双层百叶风口",{"key":24,"text":53,"correct":26},"旋流风口",{"key":28,"text":55,"correct":22},"散流器",{"key":31,"text":57,"correct":26},"球形可调风口",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},891324,"在排风系统中，利用生产过程或设备产生的气流，诱导有害物随气流进入罩内的排风罩是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"局部密闭罩",{"key":24,"text":65,"correct":26},"外部吸气罩",{"key":28,"text":67,"correct":22},"接受式排风罩",{"key":31,"text":69,"correct":26},"吹吸式排风罩",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},891325,"一种最简单的消声器，利用多孔吸声材料来降低噪声，制作方便，阻力小，但只适用于较小的风道，直径一般不大于400mm风管，这种消声器是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"管式消声器",{"key":24,"text":77,"correct":26},"微穿孔式消声器",{"key":28,"text":79,"correct":26},"阻抗复合式消声器",{"key":31,"text":81,"correct":26},"消声弯头",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},891326,"民用建筑空调制冷工程中，具有制造简单、价格低廉、运行可靠、使用灵活等优点，在民用建筑空调中占重要地位的冷水机组是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"离心式冷水机组",{"key":24,"text":89,"correct":22},"活塞式冷水机组",{"key":28,"text":91,"correct":26},"螺杆式冷水机组",{"key":31,"text":93,"correct":26},"转子式冷水机组",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},891327,"空调系统的主要设备中，通常用在电力紧张的地方，但需要提供蒸汽或高温热水的吸收式制冷机组为（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"压缩式制冷机",{"key":24,"text":101,"correct":26},"离心式制冷机",{"key":28,"text":103,"correct":22},"吸收式冷水机",{"key":31,"text":105,"correct":26},"蓄冷式冷水机",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},891328,"空调冷冻机组内的管道安装，应编码列项的工程项目是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"通风空调工程",{"key":24,"text":113,"correct":22},"工业管道工程",{"key":28,"text":115,"correct":26},"消防工程",{"key":31,"text":117,"correct":26},"给排水、采暖、燃气工程",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},891329,"依据《通用安装工程量计算规范》（GB 50856－2013）的规定，计算通风管道制作安装工程量时，应按其设计图示以展开面积计算，其中需扣除的面积为（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"送、吸风口面积",{"key":24,"text":125,"correct":22},"风管蝶阀面积",{"key":28,"text":127,"correct":26},"测定孔面积",{"key":31,"text":129,"correct":26},"检查孔面积",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},891330,"适用于大型建筑群、超高层建筑，可对建筑中的消防设备实现联动控制和手动控制的火灾自动报警系统为（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"区域报警系统",{"key":24,"text":137,"correct":26},"集中报警控制器",{"key":28,"text":139,"correct":26},"联动报警系统",{"key":31,"text":141,"correct":22},"控制中心报警系统",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":31,"analysis":33},891331,"为火灾探测器供电，接收探测点火警电信号，以声、光信号发出火灾报警，是整个火灾自动报警系统的指挥中心的消防设备为（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"输入模块",{"key":24,"text":149,"correct":26},"控制模块",{"key":28,"text":151,"correct":26},"联动控制器",{"key":31,"text":153,"correct":22},"火灾自动报警控制器",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},891332,"自动喷水雨淋式灭火系统包括管道系统、雨淋阀、火灾探测器以及（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":26},"水流指示器",{"key":24,"text":161,"correct":26},"预作用阀",{"key":28,"text":163,"correct":22},"开式洒水喷头",{"key":31,"text":165,"correct":26},"闭式喷头",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},891333,"喷水灭火系统中，不具备直接灭火的灭火系统为（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":26},"水喷雾系统",{"key":24,"text":173,"correct":22},"水幕系统",{"key":28,"text":175,"correct":26},"自动喷水干式系统",{"key":31,"text":177,"correct":26},"自动喷水预作用系统",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":31,"analysis":33},891334,"适用于由于空间高度较高，采用自动喷水灭火系统难以有效探测、扑灭及控制火灾的大空间场所的灭火系统为（ ）。",[182,183,184,186],{"key":20,"text":171,"correct":26},{"key":24,"text":173,"correct":26},{"key":28,"text":185,"correct":26},"消火栓灭火系统",{"key":31,"text":187,"correct":22},"消防水炮灭火系统",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":20,"analysis":33},891335,"具有多种灭火机理，一般用在扑灭可燃液体火灾或电器火灾中的灭火系统为（ ）。",[192,193,194,195],{"key":20,"text":171,"correct":22},{"key":24,"text":173,"correct":26},{"key":28,"text":185,"correct":26},{"key":31,"text":187,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":24,"analysis":33},891336,"泡沫发泡倍数在20～200倍之间的泡沫灭火系统为（ ）。",[200,202,204,206],{"key":20,"text":201,"correct":26},"低倍数泡沫灭火系统",{"key":24,"text":203,"correct":22},"中倍数泡沫灭火系统",{"key":28,"text":205,"correct":26},"中高倍数泡沫灭火系统",{"key":31,"text":207,"correct":26},"高倍数泡沫灭火系统",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":28,"analysis":33},891337,"消防报警系统配管、配线、接线盒应编码列项的项目为（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":26},"附录E建筑智能化工程",{"key":24,"text":215,"correct":26},"附录K给排水采暖燃气工程",{"key":28,"text":217,"correct":22},"附录D电气设备安装工程",{"key":31,"text":219,"correct":26},"附录F自动化控制仪表安装工程",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":20,"analysis":33},891338,"消防系统调试，自动喷洒系统工程计量为（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":22},"按水流指示器数量以点（支路）计算",{"key":24,"text":227,"correct":26},"按消火栓启泵按钮数量以点计算",{"key":28,"text":229,"correct":26},"按水炮数量以点计算",{"key":31,"text":231,"correct":26},"按控制装置的点数计算",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":20,"analysis":33},891339,"大中型企业由于负荷较大，往往采用35kV（或以上）电源进线，降压至10kV或6kV，再向各车间变电所和高压用电设备配电，称为（ ）。",[236,238,240,242],{"key":20,"text":237,"correct":22},"总降压变电所",{"key":24,"text":239,"correct":26},"车间变电所",{"key":28,"text":241,"correct":26},"独立变电所",{"key":31,"text":243,"correct":26},"杆上变电所",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":24,"analysis":33},891340,"建筑物及高层建筑物变电所中高压开关，从防火安全角度考虑，一般不采用（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":26},"空气断路器",{"key":24,"text":251,"correct":22},"少油断路器",{"key":28,"text":253,"correct":26},"六氟化硫断路器",{"key":31,"text":255,"correct":26},"真空断路器",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":20,"analysis":33},891341,"当动力设备数量不多，容量大小差别较大，设备运行状态比较平稳时，主配电箱安装在容量较大的设备附近，可以采用的低压配电系统为（ ）。",[260,262,264,266],{"key":20,"text":261,"correct":22},"放射式动力配电系统",{"key":24,"text":263,"correct":26},"树干式动力配电系统",{"key":28,"text":265,"correct":26},"链式动力配电系统",{"key":31,"text":267,"correct":26},"环形式动力配电系统",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":28,"analysis":33},891342,"为了保证人身安全，防止触电事故,如电气设备正常运行时不带电的金属外壳及构架的接地为（ ）。",[272,274,276,278],{"key":20,"text":273,"correct":26},"工作接地",{"key":24,"text":275,"correct":26},"保护接零",{"key":28,"text":277,"correct":22},"保护接地",{"key":31,"text":279,"correct":26},"重复接地",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":24,"analysis":33},891343,"主要功能是保证其他设备和线路的安全检修及人身安全，断开后具有明显的可见断开间隙，保证绝缘可靠，该高压开关为（ ）。",[284,285,287,289],{"key":20,"text":253,"correct":26},{"key":24,"text":286,"correct":22},"高压隔离开关",{"key":28,"text":288,"correct":26},"高压熔断器",{"key":31,"text":290,"correct":26},"互感器",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":28,"analysis":33},891344,"具有良好的非线性、动作迅速、残压低、通流容量大、无续流、耐污能力强等优点，是传统避雷器的更新换代产品，在电站及变电所中得到了广泛应用的避雷器是（ ）。",[295,297,299,301],{"key":20,"text":296,"correct":26},"管型避雷器",{"key":24,"text":298,"correct":26},"阀型避雷器",{"key":28,"text":300,"correct":22},"氧化锌避雷器",{"key":31,"text":302,"correct":26},"保护间隙避雷器",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":31,"analysis":33},891345,"在变配电系统中，避免短路电流直接流过测量仪表的重要设备是（ ）。",[307,309,311,313],{"key":20,"text":308,"correct":26},"断路器",{"key":24,"text":310,"correct":26},"隔离开关",{"key":28,"text":312,"correct":26},"调压器",{"key":31,"text":290,"correct":22},{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":28,"analysis":33},891346,"在电气照明配管配线工程中，不可明配的管道有（ ）。",[318,320,322,324],{"key":20,"text":319,"correct":26},"钢管",{"key":24,"text":321,"correct":26},"硬塑料管",{"key":28,"text":323,"correct":22},"半硬塑料管",{"key":31,"text":325,"correct":26},"电线管",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":20,"analysis":33},891347,"穿管配线时，管内导线的截面总和不应超过管子截面积的（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"40%",{"key":24,"text":333,"correct":26},"50%",{"key":28,"text":335,"correct":26},"60%",{"key":31,"text":337,"correct":26},"70%",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":20,"analysis":33},891348,"电力电缆安装前要进行检查，对1KV以上的电缆进线检查的内容是（ ）",[342,344,346,348],{"key":20,"text":343,"correct":22},"直流耐压试验",{"key":24,"text":345,"correct":26},"交流耐压实验",{"key":28,"text":347,"correct":26},"用500V摇表测绝缘",{"key":31,"text":349,"correct":26},"用1000V摇表测绝缘",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":20,"analysis":33},891349,"电缆安装工程施工时，下列做法中正确的是（ ）。",[354,356,358,360],{"key":20,"text":355,"correct":22},"直埋电缆做波浪形敷设",{"key":24,"text":357,"correct":26},"在三相四线制系统中采用三芯电缆另加一根单芯电缆",{"key":28,"text":359,"correct":26},"并联运行电缆采用不同型号、规格及长度的电缆",{"key":31,"text":361,"correct":26},"裸钢带铠装电缆进行直接埋地敷设",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":31,"analysis":33},891350,"电缆在室外可以直接埋地敷设，经过农田的电缆埋设深度不应小于（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":26},"0.5m",{"key":24,"text":369,"correct":26},"0.7m",{"key":28,"text":371,"correct":26},"0.8m",{"key":31,"text":373,"correct":22},"1.0m",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":28,"analysis":33},891351,"多根电缆同沟敷设时，10kV以上电缆平行距离为（ ）。",[378,380,382,384],{"key":20,"text":379,"correct":26},"150mm",{"key":24,"text":381,"correct":26},"170mm",{"key":28,"text":383,"correct":22},"350mm",{"key":31,"text":385,"correct":26},"400mm",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":28,"analysis":33},891352,"检验电气设备承受雷电压和操作电压的绝缘性能和保护性能，应采用的检验方法为（ ）。",[390,392,393,395],{"key":20,"text":391,"correct":26},"绝缘电阻测试",{"key":24,"text":343,"correct":26},{"key":28,"text":394,"correct":22},"冲击波试验",{"key":31,"text":396,"correct":26},"泄漏电流测试",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":28,"analysis":33},891353,"人工垂直接地体的长度宜为（ ）。",[401,402,404,406],{"key":20,"text":367,"correct":26},{"key":24,"text":403,"correct":26},"1m",{"key":28,"text":405,"correct":22},"2.5m",{"key":31,"text":407,"correct":26},"5m",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":24,"analysis":33},891354,"针式接地极的接地电阻应小于（ ）。",[412,414,416,418],{"key":20,"text":413,"correct":26},"1Ω",{"key":24,"text":415,"correct":22},"4Ω",{"key":28,"text":417,"correct":26},"5Ω",{"key":31,"text":419,"correct":26},"10Ω",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":31,"analysis":33},891355,"根据《通用安装工程工程量计算规范》，单独安装的铁壳开关、自动开关的外部进出线预留长度应从（ ）。",[424,426,428,430],{"key":20,"text":425,"correct":26},"安装对象最远端子接口算起",{"key":24,"text":427,"correct":26},"安装对象最近端子接口算起",{"key":28,"text":429,"correct":26},"安装对象下端往上2\u002F3处算起",{"key":31,"text":431,"correct":22},"安装对象中心算起",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":33},891356,"—般位于内部网的入口处，能检测到的攻击类型常见的是：系统扫描、拒绝服务和系统渗透，这种网络安全系统是（ ）。",[436,438,440,442],{"key":20,"text":437,"correct":26},"防火墙",{"key":24,"text":439,"correct":22},"IDS（网络入侵检测系统）",{"key":28,"text":441,"correct":26},"IPS（入侵防御系统）",{"key":31,"text":443,"correct":26},"杀毒软件",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":31,"analysis":33},891357,"由终端设备连接到信息插座之间的设备组成，包括信息插座、插座盒（或面板）、连接软线、适配器等，该综合布线子系统为（ ）。",[448,450,452,454],{"key":20,"text":449,"correct":26},"管理系统",{"key":24,"text":451,"correct":26},"配线子系统",{"key":28,"text":453,"correct":26},"入口设施",{"key":31,"text":455,"correct":22},"工作区",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":28,"analysis":33},891358,"有线电视系统中前端部分设备的有（ ）。",[460,462,464,466],{"key":20,"text":461,"correct":26},"自播节目设备",{"key":24,"text":463,"correct":26},"卫星天线",{"key":28,"text":465,"correct":22},"调制解调器",{"key":31,"text":467,"correct":26},"线路均衡器",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":20,"analysis":33},891359,"公共广播系统从服务功能上划分为（ ）。",[472,474,476,478],{"key":20,"text":473,"correct":22},"背景音乐广播",{"key":24,"text":475,"correct":26},"传统公共广播器材",{"key":28,"text":477,"correct":26},"数字可寻址公共广播器材",{"key":31,"text":479,"correct":26},"流媒体（IP）智能数字广播",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":24,"analysis":33},891360,"电子信息系统运行中断将造成较大的经济损失或公共场所秩序混乱，该机房工程等级为（ ）。",[484,486,488,490],{"key":20,"text":485,"correct":26},"A级",{"key":24,"text":487,"correct":22},"B级",{"key":28,"text":489,"correct":26},"C级",{"key":31,"text":491,"correct":26},"D级",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":20,"analysis":33},891361,"建筑智能化工程中的配管工程、线槽、桥架、电气设备、电气器件、接线箱、盒等应编码列项的工程为（ ）。",[496,498,499,500],{"key":20,"text":497,"correct":22},"附录D电气设备工程",{"key":24,"text":213,"correct":26},{"key":28,"text":219,"correct":26},{"key":31,"text":501,"correct":26},"附录Ｌ通信设备及线路工程",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":24,"analysis":33},891362,"有线电视系统所涉及的视频线缆敷设、接头制作、前端机柜、用户终端安装执行的定额子目为（ ）。",[506,508,510,512],{"key":20,"text":507,"correct":26},"第一章计算机应用、网络系统工程",{"key":24,"text":509,"correct":22},"第二章综合布线系统工程",{"key":28,"text":511,"correct":26},"第五章有线电视卫星接收系统工程",{"key":31,"text":513,"correct":26},"第六章音频视频工程",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":20,"analysis":33},891363,"施工组织设计的编制依据有（ ）。",[518,520,522,524],{"key":20,"text":519,"correct":22},"招标投标文件",{"key":24,"text":521,"correct":26},"将批准的设计资料",{"key":28,"text":523,"correct":26},"将签约的与工程有关的协议",{"key":31,"text":525,"correct":26},"发包人的生产能力、技术装备",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":24,"analysis":33},891364,"测量较贵，适用于高黏度介质流量的测量，不适用于含有固体颗粒的液体， 精度较高，计量稳定的流量仪表为（ ）。",[530,532,534,536],{"key":20,"text":531,"correct":26},"涡轮流量计",{"key":24,"text":533,"correct":22},"椭圆齿轮流量计",{"key":28,"text":535,"correct":26},"均速管流量计",{"key":31,"text":537,"correct":26},"玻璃管转子流量计",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":28,"analysis":33},891365,"一种主要的压力标准计量仪器，测量精度很高，可用来检验精密压力表的压力表为（ ）。",[542,544,546,548],{"key":20,"text":543,"correct":26},"弹性式压力计",{"key":24,"text":545,"correct":26},"液柱式压力计",{"key":28,"text":547,"correct":22},"活塞式压力计",{"key":31,"text":549,"correct":26},"电气式压力计",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":28,"analysis":33},891366,"用于测量各种温度物体，测量范围极大，远远大于酒精、水银温度计，适用于测量炼钢炉、炼焦炉等高温场合，也可测量液态氢、液态氮等低温物体的温度计为（ ）。",[554,556,558,560],{"key":20,"text":555,"correct":26},"压力式温度计",{"key":24,"text":557,"correct":26},"双金属温度计",{"key":28,"text":559,"correct":22},"热电偶温度计",{"key":31,"text":561,"correct":26},"热电阻温度计",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":31,"analysis":33},891367,"当滑车的轮数超过5个时，穿绕跑绳应采用的方法为（ ）。",[566,568,570,572],{"key":20,"text":567,"correct":26},"顺穿",{"key":24,"text":569,"correct":26},"逆穿",{"key":28,"text":571,"correct":26},"花穿",{"key":31,"text":573,"correct":22},"双抽头方式",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":31,"analysis":33},891368,"建筑、安装工程常用的臂架型起重机有（ ）。",[578,580,582,584],{"key":20,"text":579,"correct":26},"梁式起重机",{"key":24,"text":581,"correct":26},"桥式起重机",{"key":28,"text":583,"correct":26},"门式起重机",{"key":31,"text":585,"correct":22},"塔式起重机",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":24,"analysis":33},891369,"LNG罐顶部防潮层钢板外侧需焊接大量的混凝土挂钉，可提高功效十几倍的焊接方法为（ ）。",[590,592,594,596],{"key":20,"text":591,"correct":26},"焊条电弧焊",{"key":24,"text":593,"correct":22},"螺柱焊",{"key":28,"text":595,"correct":26},"药芯焊丝电弧焊",{"key":31,"text":597,"correct":26},"埋弧焊",{"id":599,"libraryId":5,"type":15,"typeLabel":16,"stem":600,"options":601,"answer":24,"analysis":33},891370,"连接薄板金属和打底焊的一种极好的焊接方法是（ ）。",[602,603,605,606],{"key":20,"text":591,"correct":26},{"key":24,"text":604,"correct":22},"钨极气体保护焊",{"key":28,"text":595,"correct":26},{"key":31,"text":597,"correct":26},[608,611,614,617,620,623],{"id":15,"name":609,"category":7,"favorite":610},"领导干部任职前廉政法规知识测试题",92,{"id":612,"name":613,"category":7,"favorite":15},595,"建筑结构与设备",{"id":615,"name":616,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":618,"name":619,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":621,"name":622,"category":7,"favorite":8},534,"BIM工程师",{"id":624,"name":622,"category":7,"favorite":8},535]