[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-577-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":589},{"id":5,"name":6,"category":7,"favorite":8},577,"[安装工程]建设工程计量与计价实务","建筑工程",0,14,50,1537,[13,34,46,58,70,82,94,106,118,130,142,151,163,175,187,199,208,220,232,241,253,265,276,287,299,311,319,329,341,351,363,375,385,397,409,421,433,445,457,467,479,486,498,510,521,533,545,557,569,577],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},891167,1,"单选题","下列关于消防系统调试定额项目执行注意事项的说法中，错误的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","系统调试的前提是消防系统安装完毕且联通，并达到国家相关验收标准",false,{"key":24,"text":25,"correct":26},"B","定额中应包括气体灭火系统调试试验时采取的安全措施",true,{"key":28,"text":29,"correct":22},"C","自动报警系统中包含各类探测器",{"key":31,"text":32,"correct":22},"D","消防系统的调试项目包括自动报警系统.水灭火系统.防火控制装置和气体灭火系统装置调试","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},891168,"下列气体灭火系统定额项目执行中的注意事项中，错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"定额中的无缝钢管.钢制管件.选择阀安装及系统组件试验等适用于七氟丙烷.IG541灭火系统",{"key":24,"text":41,"correct":26},"高压二化碳灭火系统执行本章定额，但子目中的人工.机械乘以系数1.50",{"key":28,"text":43,"correct":22},"无缝钢管法兰连接定额包括管件及法兰安装，螺栓按设计用量加3%损耗计算",{"key":31,"text":45,"correct":22},"气体灭火系统管道若采用不锈钢管.铜管时，管道及管件安装执行第八册《工业管道工程》相应子目",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},891169,"点型火灾探测器的类型包括（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"感烟探测器",{"key":24,"text":53,"correct":26},"紫外线探测器",{"key":28,"text":55,"correct":22},"感温探测器",{"key":31,"text":57,"correct":22},"可燃气体探测器",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},891170,"下列不属于室内消火栓安装清单项目的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"消火栓箱",{"key":24,"text":65,"correct":22},"水枪",{"key":28,"text":67,"correct":22},"水带挂架",{"key":31,"text":69,"correct":26},"连接管",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},891171,"水灭火系统是消防工程中一项重要的分部工程，下列不属于水灭火系统工程的分项工程是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"防火阀",{"key":24,"text":77,"correct":22},"末端试水装置",{"key":28,"text":79,"correct":22},"水流指示器",{"key":31,"text":81,"correct":22},"室内消火栓",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},891173,"给水系统分区设置水箱和水泵，水泵分散布置，总管线较短，投资较省，能量消耗较小，但供水独立性差，上区受下区限制的给水方式是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"分区水箱减压给水",{"key":24,"text":89,"correct":26},"分区串联给水",{"key":28,"text":91,"correct":22},"分区并联给水",{"key":31,"text":93,"correct":22},"高位水箱减压阀给水",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},891174,"室内给水管网上阀门设置正确的（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"DN≤50mm，使用闸阀和蝶阀",{"key":24,"text":101,"correct":26},"DN≤50mm，使用闸阀和球阀",{"key":28,"text":103,"correct":22},"DN＞50mm，使用闸阀和球阀",{"key":31,"text":105,"correct":22},"DN＞50mm，使用球阀和蝶阀",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},891175,"排出管应作（ ）试验。",[110,112,114,116],{"key":20,"text":111,"correct":22},"水压试验",{"key":24,"text":113,"correct":22},"通球试验",{"key":28,"text":115,"correct":26},"灌水试验",{"key":31,"text":117,"correct":22},"气压试验",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},891176,"室内给水管道试验压力为工作压力的（ ），不得小于0.6MPa。",[122,124,126,128],{"key":20,"text":123,"correct":22},"0.8倍",{"key":24,"text":125,"correct":22},"1.0倍",{"key":28,"text":127,"correct":22},"1.15倍",{"key":31,"text":129,"correct":26},"1.5倍",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},891177,"建筑给水系统中，一般采用（ ）水泵，它具有结构简单、体积小、效率高，且流量和扬程在一定范围内可以调整等优点。",[134,136,138,140],{"key":20,"text":135,"correct":22},"混流式",{"key":24,"text":137,"correct":22},"真空式",{"key":28,"text":139,"correct":26},"离心式",{"key":31,"text":141,"correct":22},"轴流式",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},891179,"利用水箱减压，适用于允许分区设备水箱，电力供应充足，电价较低的各类高层建筑，水泵数目少，维护管理方便，分区水箱容积小，少占建筑面积，下区供水受上区限制，屋顶水箱容积大，这种供水方式为（ ）。",[146,147,148,149],{"key":20,"text":91,"correct":22},{"key":24,"text":89,"correct":22},{"key":28,"text":87,"correct":26},{"key":31,"text":150,"correct":22},"分区减压阀减压给水",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":28,"analysis":33},891180,"与铸铁散热器相比，钢制散热器的特点是（ ）。",[155,157,159,161],{"key":20,"text":156,"correct":22},"结构简单，热稳定性好",{"key":24,"text":158,"correct":22},"防腐蚀性好",{"key":28,"text":160,"correct":26},"耐压强度高",{"key":31,"text":162,"correct":22},"占地小，使用寿命长",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":24,"analysis":33},891181,"当引入口遇到暖气沟或地下室时，因规范不允许燃气管道通过，必须从室外绕行，故需要做（ ）。",[167,169,171,173],{"key":20,"text":168,"correct":22},"地下引入口",{"key":24,"text":170,"correct":26},"地上引入口",{"key":28,"text":172,"correct":22},"侧面引入口",{"key":31,"text":174,"correct":22},"外墙引入口",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":31,"analysis":33},891182,"某补偿器优点是制造方便、补偿能力大、轴向推力小、维修方便、运行可靠；缺点是占地面积较大。此种补偿器为（ ）。",[179,181,183,185],{"key":20,"text":180,"correct":22},"填料补偿器",{"key":24,"text":182,"correct":22},"波形补偿器",{"key":28,"text":184,"correct":22},"球形补偿器",{"key":31,"text":186,"correct":26},"方形补偿器",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":24,"analysis":33},891183,"住宅建筑应在配水管上和分户管上设置水表，根据有关规定，（ ）水表在表前与阀门间应有8-10倍水表直径的直线管段。",[191,193,195,197],{"key":20,"text":192,"correct":22},"旋翼式",{"key":24,"text":194,"correct":26},"螺翼式",{"key":28,"text":196,"correct":22},"孔板式",{"key":31,"text":198,"correct":22},"容积活塞式",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":31,"analysis":33},891184,"在室内排水系统的排出管施工中，隐蔽前必须做（ ）。",[203,204,205,207],{"key":20,"text":111,"correct":22},{"key":24,"text":117,"correct":22},{"key":28,"text":206,"correct":22},"渗漏试验",{"key":31,"text":115,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":28,"analysis":33},891185,"布置简单，基建投资少，运行管理方便，是热网最普遍采用的形式，此种管网布置形式为（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":22},"平行管网",{"key":24,"text":215,"correct":22},"辐射管网",{"key":28,"text":217,"correct":26},"枝状管网",{"key":31,"text":219,"correct":22},"环状管网",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":24,"analysis":33},891186,"装饰性强，小体积能达到最佳散热效果，无需加暖气罩，最大程度减小室内占用空间，提高房间的利用率的散热器结构形式为（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":22},"翼型散热器",{"key":24,"text":227,"correct":26},"钢制板式散热器",{"key":28,"text":229,"correct":22},"钢制翅片管对流散热器",{"key":31,"text":231,"correct":22},"光排管散热器",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":24,"analysis":33},891187,"燃气系统中，埋地铺设的聚乙烯管道长管段上通常设置（ ）。",[236,237,239,240],{"key":20,"text":186,"correct":22},{"key":24,"text":238,"correct":26},"套筒补偿器",{"key":28,"text":182,"correct":22},{"key":31,"text":184,"correct":22},{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":31,"analysis":33},891189,"关于建筑给水、排水、采暖及燃气工程所用阀门的说法错误的是（ ）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"阀门安装前应做强度试验",{"key":24,"text":248,"correct":22},"阀门安装前做严密性试验",{"key":28,"text":250,"correct":22},"在主干管上起切断作用的闭路阀门应逐个做强度和严密性试验",{"key":31,"text":252,"correct":26},"阀门安装后应作强度和严密性试验",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":28,"analysis":33},891190,"燃气管道试验介质宜采用（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":22},"水",{"key":24,"text":260,"correct":22},"燃气",{"key":28,"text":262,"correct":26},"空气",{"key":31,"text":264,"correct":22},"液压油",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":28,"analysis":33},891191,"非承压管道系统和设备在隐蔽前必须做（ ）。",[269,271,273,274],{"key":20,"text":270,"correct":22},"强度试验",{"key":24,"text":272,"correct":22},"严密性试验",{"key":28,"text":115,"correct":26},{"key":31,"text":275,"correct":22},"通水试验",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":20,"analysis":33},891192,"在连接（ ）上大便器的污水横管上应设置清扫口。",[280,282,284,285],{"key":20,"text":281,"correct":26},"2个及2以上",{"key":24,"text":283,"correct":22},"3个及3以上",{"key":28,"text":283,"correct":22},{"key":31,"text":286,"correct":22},"4个及4以上",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":24,"analysis":33},891193,"室内给水管道应设置阀门，当管径大于50mm时宜采用（ ）。",[291,293,295,297],{"key":20,"text":292,"correct":22},"球阀",{"key":24,"text":294,"correct":26},"蝶阀",{"key":28,"text":296,"correct":22},"截止阀",{"key":31,"text":298,"correct":22},"旋塞阀",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":20,"analysis":33},891194,"给水管道材料使用中，在一般民用建筑，采用低压流体输送时用（ ）。",[303,305,307,309],{"key":20,"text":304,"correct":26},"镀锌焊接钢管",{"key":24,"text":306,"correct":22},"镀锌无缝钢管",{"key":28,"text":308,"correct":22},"给水硬聚氯乙烯管",{"key":31,"text":310,"correct":22},"衬塑铝合金管",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":20,"analysis":33},891195,"室内给水管道应设置阀门，当管径小于或等于50mm时宜采用（ ）。",[315,316,317,318],{"key":20,"text":292,"correct":26},{"key":24,"text":294,"correct":22},{"key":28,"text":296,"correct":22},{"key":31,"text":298,"correct":22},{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":28,"analysis":33},891196,"高级、高层民用建筑室内给水系统中，对于DN＜150mm的冷水管，宜采用的管材为（ ）。",[323,325,326,328],{"key":20,"text":324,"correct":22},"给水聚丙烯管",{"key":24,"text":310,"correct":22},{"key":28,"text":327,"correct":26},"薄壁铜管",{"key":31,"text":306,"correct":22},{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":20,"analysis":33},891197,"室内给水系统采用设贮水池、水泵的给水方式时，其不足之处为（ ）。",[333,335,337,339],{"key":20,"text":334,"correct":26},"外网水压没有充分利用",{"key":24,"text":336,"correct":22},"增加建筑物结构荷载",{"key":28,"text":338,"correct":22},"供水的安全性.可靠性低",{"key":31,"text":340,"correct":22},"不适用于城市建筑小区定时或全日供水",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":20,"analysis":33},891198,"适用于系统工作压力小于等于0.6MPa，工作温度小于等于70℃室内给水系统，采用热熔承插链接，与金属配管配件用螺纹连接的给水管材是（ ）。",[345,346,348,350],{"key":20,"text":324,"correct":26},{"key":24,"text":347,"correct":22},"给水聚乙烯管",{"key":28,"text":349,"correct":22},"工程塑料管",{"key":31,"text":308,"correct":22},{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":24,"analysis":33},891199,"硬聚氯乙烯给水管（UPV C）的应用场合为（ ）。",[355,357,359,361],{"key":20,"text":356,"correct":22},"给水温度50℃的生活给水系统",{"key":24,"text":358,"correct":26},"工作压力0.5MPa的生活给水系统",{"key":28,"text":360,"correct":22},"高层建筑的加压泵房内的给水管",{"key":31,"text":362,"correct":22},"水箱的进出水管",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":28,"analysis":33},891200,"排水系统中，伸顶通气管高出屋面不得小于（）m，且必须大于最大积雪厚度。",[367,369,371,373],{"key":20,"text":368,"correct":22},"0.1",{"key":24,"text":370,"correct":22},"0.2",{"key":28,"text":372,"correct":26},"0.3",{"key":31,"text":374,"correct":22},"0.5",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":20,"analysis":33},891201,"在室内排水系统中，排水立管安装后应做（ ）。",[379,380,382,383],{"key":20,"text":113,"correct":26},{"key":24,"text":381,"correct":22},"高压水清洗",{"key":28,"text":111,"correct":22},{"key":31,"text":384,"correct":22},"化学清洗",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":24,"analysis":33},891202,"在施工及设计说明中，主要说明给水、排水及消防系统所采用的管材、附件和连接方式，给水管材出厂压力要求，试验压力和工作压力之间的倍数关系的部分是（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":22},"工程概况",{"key":24,"text":392,"correct":26},"管材与附件",{"key":28,"text":394,"correct":22},"管道防腐.绝热",{"key":31,"text":396,"correct":22},"管道支吊架",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":28,"analysis":33},891203,"下列选项中关于刷油工程计量的说法正确的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":22},"管道刷油可以按按金属结构的理论质量计算，计量单位为“kg”",{"key":24,"text":404,"correct":22},"铸铁管和暖气片刷油管道刷油可以按金属结构的理论质量计算，计量单位为“kg”",{"key":28,"text":406,"correct":26},"管道刷油可以按设计图示尺寸以长度计算，计量单位为“m”",{"key":31,"text":408,"correct":22},"金属结构刷油清单项目可以按设计图示尺寸以长度计算，计量单位为“m”",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":28,"analysis":33},891204,"下列选项中关于系统调试费计取方法说法错误的是（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":22},"采暖系统调试费按采暖工程人工费的10%计算",{"key":24,"text":416,"correct":22},"空调水系统调试费按空调水工程人工费的10%计算",{"key":28,"text":418,"correct":26},"系统调试费不构成工程实体的费用",{"key":31,"text":420,"correct":22},"系统调试费在工程量清单计价中应列入分部分项工程费用中",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":24,"analysis":33},891205,"第十册《给排水、采暖、燃气工程》中，第四章“燃气管道”内容适用于工作压力（ ）的室内外中、低压燃气管道，不适用于高压燃气管道、生产燃气管道和市政燃气管道。",[425,427,429,431],{"key":20,"text":426,"correct":22},"不大于0.8MPa",{"key":24,"text":428,"correct":26},"不大于0.6MPa",{"key":28,"text":430,"correct":22},"小于0.8MPa",{"key":31,"text":432,"correct":22},"小于0.6MPa",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":28,"analysis":33},891206,"第十册《给排水、采暖、燃气工程》中，第八章“燃气器具及其他”，户内家用可燃气体检测报警器与电磁阀成套暗装的，执行“第五章管道附件”中螺纹电电磁阀项目，人工乘以系数（ ）。",[437,439,441,443],{"key":20,"text":438,"correct":22},"0.8",{"key":24,"text":440,"correct":22},"1.2",{"key":28,"text":442,"correct":26},"1.3",{"key":31,"text":444,"correct":22},"1.5",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":24,"analysis":33},891207,"下列选项中，关于刷油工程说法错误的是（ ）。",[449,451,453,455],{"key":20,"text":450,"correct":22},"各种管件.阀门和设备上人孔.管口凸凹部分的刷油已综合考虑在定额内",{"key":24,"text":452,"correct":26},"零星刷油人工乘以系数1.1",{"key":28,"text":454,"correct":22},"刷油和防腐蚀工程按安装场地内涂刷油漆考虑",{"key":31,"text":456,"correct":22},"主材与稀干料可以换算，但人工和材料消耗量不变",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},891208,"根据《2017安装预算定额》第十二册《刷油、防腐蚀、绝热工程》，管道若先绝热后安装，其人工乘以系数（ ）。",[461,463,465,466],{"key":20,"text":462,"correct":22},"0.45",{"key":24,"text":464,"correct":26},"0.9",{"key":28,"text":440,"correct":22},{"key":31,"text":444,"correct":22},{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":31,"analysis":33},891209,"下列选项中关于绝热工程量计算规则及计置单位的说法错误的是（ ）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"设备绝热.管道绝热.阀门绝热和法兰绝热清单项目工程量均按设计图示表面积加绝热层厚度及调整系数以体积计算，计量单位为“m3”",{"key":24,"text":474,"correct":22},"通风管道绝热清单项目工程量计算可以按设计图示表面积加绝热层厚度及调整系数以体积计算，计量单位为“m3”",{"key":28,"text":476,"correct":22},"防潮层.保护层清单项目工程量计算可以按图示金属结构的质量计算，计量单位为“kg”",{"key":31,"text":478,"correct":26},"喷涂.涂抹清单项目工程量按金属结构的质量计算，计量单位为“kg”",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":481,"answer":24,"analysis":33},891210,[482,483,484,485],{"key":20,"text":87,"correct":22},{"key":24,"text":89,"correct":26},{"key":28,"text":91,"correct":22},{"key":31,"text":93,"correct":22},{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":31,"analysis":33},891211,"具有耐腐蚀、寿命长的优点，但是管壁厚、质脆、强度较钢管差，尤其适用于埋地铺设，多用于DN≥75mm的给水管材是（ ）。",[490,492,494,496],{"key":20,"text":491,"correct":22},"钢管",{"key":24,"text":493,"correct":22},"铜管",{"key":28,"text":495,"correct":22},"不锈钢管",{"key":31,"text":497,"correct":26},"给水铸铁管",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":28,"analysis":33},891212,"建筑给水系统设有水箱时，水泵的扬程设置应（ ）。",[502,504,506,508],{"key":20,"text":503,"correct":22},"满足最不利处的配水点或消火栓所需水压",{"key":24,"text":505,"correct":22},"满足距水泵直线距离最远处配水点或消火栓所需水压",{"key":28,"text":507,"correct":26},"满足水箱进水所需水压和消火栓所需水压",{"key":31,"text":509,"correct":22},"满足水箱出水所需水压和消火栓所需水压",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":24,"analysis":33},891213,"第十册《给排水、采暖、燃气工程》中规定，在洞库、暗室，已封闭的管道间（井）、地沟、吊顶内安装的项目，人工、机械乘以系数（ ）。",[514,516,517,519],{"key":20,"text":515,"correct":22},"1.1",{"key":24,"text":440,"correct":26},{"key":28,"text":518,"correct":22},"1.02",{"key":31,"text":520,"correct":22},"1.22",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":31,"analysis":33},891214,"下列管道中，室内外界线以地上引入室内的管道以墙外三通为界的管道是（ ）。",[525,527,529,531],{"key":20,"text":526,"correct":22},"采暖管道",{"key":24,"text":528,"correct":22},"空调水管道",{"key":28,"text":530,"correct":22},"给排水管道",{"key":31,"text":532,"correct":26},"燃气管道",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":24,"analysis":33},891215,"管道规格表示与管材有关，一般用（ ）标注。",[537,539,541,543],{"key":20,"text":538,"correct":22},"外径",{"key":24,"text":540,"correct":26},"公称直径",{"key":28,"text":542,"correct":22},"内径",{"key":31,"text":544,"correct":22},"以上选项均不对",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":28,"analysis":33},891216,"室内给排水平面图是施工图的主要部分，常用比例为（ ）。",[549,551,553,555],{"key":20,"text":550,"correct":22},"1：2～1：5",{"key":24,"text":552,"correct":22},"1：5～1：10",{"key":28,"text":554,"correct":26},"1：50～1：100",{"key":31,"text":556,"correct":22},"1：100～1：500",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":31,"analysis":33},891217,"排出管与室外排水管连接处的检查井，井中心距建筑物外墙不大于（ ）。",[561,563,565,567],{"key":20,"text":562,"correct":22},"2m",{"key":24,"text":564,"correct":22},"6m",{"key":28,"text":566,"correct":22},"8m",{"key":31,"text":568,"correct":26},"10m",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":24,"analysis":33},891218,"室内排水系统中，排出管在隐蔽前必须进行的试验为（ ）。",[573,574,575,576],{"key":20,"text":111,"correct":22},{"key":24,"text":115,"correct":26},{"key":28,"text":270,"correct":22},{"key":31,"text":113,"correct":22},{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":20,"analysis":33},891219,"关于住宅小区及厂区的室外管网地铺设，说法错误的是（ ）。",[581,583,585,587],{"key":20,"text":582,"correct":26},"住宅小区及厂区的室外管网一般采用露天铺设",{"key":24,"text":584,"correct":22},"住宅小区及厂区的室外管网应铺设在当地冰冻线以下",{"key":28,"text":586,"correct":22},"住宅小区及厂区的室外管网如必须在冰冻线以上铺设时，应做可靠的保温防潮措施",{"key":31,"text":588,"correct":22},"塑料管必须露天架空敷设时应有保温和防晒措施",[590,593,596,599,602,605],{"id":15,"name":591,"category":7,"favorite":592},"领导干部任职前廉政法规知识测试题",92,{"id":594,"name":595,"category":7,"favorite":15},595,"建筑结构与设备",{"id":597,"name":598,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":600,"name":601,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":603,"name":604,"category":7,"favorite":8},534,"BIM工程师",{"id":606,"name":604,"category":7,"favorite":8},535]