[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-577-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":597},{"id":5,"name":6,"category":7,"favorite":8},577,"[安装工程]建设工程计量与计价实务","建筑工程",0,13,50,1537,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,393,400,411,422,433,443,453,464,476,488,500,512,523,535,547,557,565,573,585],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},891116,1,"单选题","能够降低建筑物内不同金属部件之间的电位差，并消除自建筑物外经电气线路和各种金属管道引入的危险故障电压危害的方法是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","局部等电位联结",false,{"key":24,"text":25,"correct":22},"B","分段等电位联结",{"key":27,"text":28,"correct":29},"C","总等电位联结",true,{"key":31,"text":32,"correct":22},"D","保护接地","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},891117,"关于建筑电气工程安装时的预埋工作，不正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"电气埋地保护管需在土建铺设地坪时预先敷设好",{"key":24,"text":41,"correct":22},"固定配电箱需在土建砌墙时同时埋设",{"key":27,"text":43,"correct":29},"避雷带的支座需在土建砌墙完成后埋设",{"key":31,"text":45,"correct":22},"进行预埋工作时，应注意不要破坏建筑物的结构强度和损坏建筑物的外观",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},891118,"配电箱的安装高度及安装位置应根据图纸设计确定。无详细规定者，配电箱底边距地面高度为（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"1m",{"key":24,"text":53,"correct":29},"1.5m",{"key":27,"text":55,"correct":22},"2m",{"key":31,"text":57,"correct":22},"2.5m",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},891119,"关于电气设备的基本试验，错误的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"绝缘电阻试验中，绝缘电阻值的大小能有效地反映绝缘的整体受潮.污秽以及严重过热老化等缺陷",{"key":24,"text":65,"correct":22},"直流耐压试验电压较高，对发现绝缘某些局部缺陷具有特殊的作用",{"key":27,"text":67,"correct":22},"交流耐压试验能有效地发现较危险的集中性缺陷",{"key":31,"text":69,"correct":29},"三倍频及工频感应耐压试验能检验电气设备承受雷电压和操作电压的绝缘性能和保护性能",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},891120,"在建筑电气工程施工图中，安装施工和编制工程预算的主要依据是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"系统图",{"key":24,"text":77,"correct":29},"平面图",{"key":27,"text":79,"correct":22},"电路图",{"key":31,"text":81,"correct":22},"详图",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},891121,"阅读建筑电气工程平面图的一般顺序是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"进线-总配电箱-支干线-干线-分配电箱-用电设备",{"key":24,"text":89,"correct":22},"进线-分配电箱-干线-支干线-总配电箱-用电设备",{"key":27,"text":91,"correct":29},"进线-总配电箱-干线-支干线-分配电箱-用电设备",{"key":31,"text":93,"correct":22},"进线-干线-支干线-总配电箱-分配电箱-用电设备",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},891122,"WC表示线路敷设在（ ）部位。",[98,100,102,104],{"key":20,"text":99,"correct":22},"暗敷设在梁内",{"key":24,"text":101,"correct":29},"暗敷设在墙内",{"key":27,"text":103,"correct":22},"沿墙面敷设",{"key":31,"text":105,"correct":22},"吊顶内敷设",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},891123,"防雷接地设备的引下线是指连接接闪器和接地装置的金属导体，优先采用（ )",[110,112,114,116],{"key":20,"text":111,"correct":22},"扁钢",{"key":24,"text":113,"correct":29},"圆钢",{"key":27,"text":115,"correct":22},"角钢",{"key":31,"text":117,"correct":22},"型钢",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},891124,"防雷接地系统安装时，在土壤条件极差的山石地区应采用接地极水平敷设。要求接地装置所用材料全部采用（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"镀锌圆钢",{"key":24,"text":125,"correct":22},"镀锌方钢",{"key":27,"text":127,"correct":22},"镀锌角钢",{"key":31,"text":129,"correct":29},"镀锌扁钢",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},891125,"民用建筑物变电所内的高压开关，从安全角度考虑，一般不采用（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"落地式真空断路器",{"key":24,"text":137,"correct":22},"手车式真空断路器",{"key":27,"text":139,"correct":29},"少油断路器",{"key":31,"text":141,"correct":22},"六氟化硫断路器",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},891126,"变电工程中，起接受电力作用的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":29},"高压配电室",{"key":24,"text":149,"correct":22},"变压器室",{"key":27,"text":151,"correct":22},"低压配电室",{"key":31,"text":153,"correct":22},"电容器室",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":27,"analysis":33},891127,"以下灯具中具有“小太阳”美称的是（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"高压钠灯",{"key":24,"text":161,"correct":22},"白炽灯",{"key":27,"text":163,"correct":29},"氙灯",{"key":31,"text":165,"correct":22},"低压钠灯",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":27,"analysis":33},891128,"直埋电缆时，埋设电缆的深度应为（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"设计深度；",{"key":24,"text":173,"correct":22},"设计埋深加50mm；",{"key":27,"text":175,"correct":29},"设计埋深加100mm",{"key":31,"text":177,"correct":22},"设计埋深加150mm",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},891129,"配线进入箱、柜、板的预留长度为（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":29},"高+宽",{"key":24,"text":185,"correct":22},"高",{"key":27,"text":187,"correct":22},"宽",{"key":31,"text":189,"correct":22},"0.3m",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":27,"analysis":33},891130,"（ ）是供配电系统的中枢。",[194,196,198,200],{"key":20,"text":195,"correct":22},"变电所",{"key":24,"text":197,"correct":22},"配电所",{"key":27,"text":199,"correct":29},"变配电所",{"key":31,"text":201,"correct":22},"防雷接地",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":27,"analysis":33},891131,"中杆灯是指安装高度在（ ）m的灯杆上的照明器具。",[206,208,210,212],{"key":20,"text":207,"correct":22},"≤15",{"key":24,"text":209,"correct":22},"＞15",{"key":27,"text":211,"correct":29},"≤19",{"key":31,"text":213,"correct":22},"＞19",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":31,"analysis":33},891132,"根据建筑电气项目计量规则，电缆安装时，防火涂料按设计图示尺寸以（ ）计算。",[218,220,222,224],{"key":20,"text":219,"correct":22},"面积“km2”",{"key":24,"text":221,"correct":22},"面积“m2”",{"key":27,"text":223,"correct":22},"质量“t”",{"key":31,"text":225,"correct":29},"质量“kg",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":27,"analysis":33},891133,"根据建筑电气项目计量规则，电阻器按设计图示数量以（ ）计算。",[230,232,234,236],{"key":20,"text":231,"correct":22},"个",{"key":24,"text":233,"correct":22},"组",{"key":27,"text":235,"correct":29},"箱",{"key":31,"text":237,"correct":22},"套",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":27,"analysis":33},891134,"根据2017电气设备安装工程预算定额，关于防雷及接地装置，错误的说法是（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":22},"本章定额已包括高空作业工时，不得另行计算",{"key":24,"text":245,"correct":22},"接地母线.引下线.避雷网的搭接长度，分别综合在有关定额子目中，不得另行计算",{"key":27,"text":247,"correct":29},"均压环敷设长度按设计需要作为均压接地梁的面积计算",{"key":31,"text":249,"correct":22},"避雷网.接地母线敷设按照设计图示敷设数量以“m”为计量单位",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":27,"analysis":33},891135,"根据2017电气设备安装工程预算定额，滑触线及支架安装高度定额是按10m以下编制的，若实际安装髙度超过此高度时，其超过部分的人工工日乘以系数（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":22},"1.5",{"key":24,"text":257,"correct":22},"1.25",{"key":27,"text":259,"correct":29},"1.2",{"key":31,"text":261,"correct":22},"1.15",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},891136,"根据2017电气设备安装工程预算定额，下列说法错误的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"脚手架搭拆费按定额人工费的5%计算，其中费用中人工费占35%",{"key":24,"text":269,"correct":29},"操作高度除各章节另有规定者外，均按3m以下编制",{"key":27,"text":271,"correct":22},"建筑物层数大于6层应计算高层建筑增加费",{"key":31,"text":273,"correct":22},"定额不包括安装所用螺栓",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},891138,"自动喷水灭火系统中，同时具有湿式系统和干式系统特点的灭火系统为（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":22},"自动喷水雨淋系统",{"key":24,"text":281,"correct":29},"自动喷水预作用系统",{"key":27,"text":283,"correct":22},"自动喷水干式灭火系统系统",{"key":31,"text":285,"correct":22},"水喷雾灭火系统",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":20,"analysis":33},891139,"（ ）灭火系统可用于扑救电气火灾、液体火灾或可熔化的固体火灾、固体表面火灾及灭火前能切断气源的气体火灾。",[290,292,294,296],{"key":20,"text":291,"correct":29},"七氟丙烷",{"key":24,"text":293,"correct":22},"二氧化碳",{"key":27,"text":295,"correct":22},"泡沫",{"key":31,"text":297,"correct":22},"干粉",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":27,"analysis":33},891140,"防火控制装置清单制作时，以“部”计算的是（ ）。",[302,304,306,308],{"key":20,"text":303,"correct":22},"电动防火门",{"key":24,"text":305,"correct":22},"防火卷帘门",{"key":27,"text":307,"correct":29},"消防电梯",{"key":31,"text":309,"correct":22},"排烟防火阀",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":27,"analysis":33},891141,"某大楼内进行自动喷水灭火系统的管道安装，下列安装顺序正确的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":22},"配水支管—配水管—配水干管",{"key":24,"text":317,"correct":22},"配水支管—配水干管—配水管",{"key":27,"text":319,"correct":29},"配水干管—配水管—配水支管",{"key":31,"text":321,"correct":22},"配水干管—配水支管—配水管",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":27,"analysis":33},891142,"自动喷水灭火系统管道安装时需注意，横向安装宜设置（ ）的坡度，坡向（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"1‰~3‰，排水管",{"key":24,"text":329,"correct":22},"2‰~5‰，供水管",{"key":27,"text":331,"correct":29},"2‰~5‰，排水管",{"key":31,"text":333,"correct":22},"1‰~3‰，供水管",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":20,"analysis":33},891143,"消防管道中设置的减压孔板设计参数错误的是（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":29},"减压孔板不应设置在50mm以下的水平管道上",{"key":24,"text":341,"correct":22},"减压孔板孔口直径不应小于管段直径的80%",{"key":27,"text":343,"correct":22},"安装在管道转弯下游的减压孔板与转弯距离不应小于管道公称直径的2倍",{"key":31,"text":345,"correct":22},"减压孔板是为了防止建筑低区压力过大损害消防设备而设置的组件",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":31,"analysis":33},891144,"声光报警器是安装在现场的声光报警设备，声光报警器一般安装在墙壁上，距地面（ ）m。",[350,352,354,356],{"key":20,"text":351,"correct":22},"1.5~1.8",{"key":24,"text":353,"correct":22},"1.8~2.0",{"key":27,"text":355,"correct":22},"1.5~2.0",{"key":31,"text":357,"correct":29},"1.8~2.5",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":31,"analysis":33},891145,"消防控制中心应具有的功能不包括（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"能独立编写程序",{"key":24,"text":365,"correct":22},"拥有对与消防相关全部系统的显示和操作功能",{"key":27,"text":367,"correct":22},"能独立显示.打印",{"key":31,"text":369,"correct":29},"不具备独立控制联动设备，需配合相应技术人员操作",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":27,"analysis":33},891146,"消防图例中，该图标表示的是（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"感烟探测器",{"key":24,"text":377,"correct":22},"燃气控制器",{"key":27,"text":379,"correct":29},"感温探测器",{"key":31,"text":381,"correct":22},"气体探测器",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":384,"answer":20,"analysis":33},891147,[385,387,389,391],{"key":20,"text":386,"correct":29},"电源自动切换箱",{"key":24,"text":388,"correct":22},"事故照明配电箱",{"key":27,"text":390,"correct":22},"信号板.箱.屏",{"key":31,"text":392,"correct":22},"柜.箱.屏",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":395,"answer":27,"analysis":33},891148,[396,397,398,399],{"key":20,"text":386,"correct":22},{"key":24,"text":388,"correct":22},{"key":27,"text":390,"correct":29},{"key":31,"text":392,"correct":22},{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":402,"answer":31,"analysis":33},891149,[403,405,407,409],{"key":20,"text":404,"correct":22},"排风扇",{"key":24,"text":406,"correct":22},"水流指示器",{"key":27,"text":408,"correct":22},"消防端子箱",{"key":31,"text":410,"correct":29},"带电话插孔的手报按钮",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":413,"answer":20,"analysis":33},891150,[414,416,418,420],{"key":20,"text":415,"correct":29},"消火栓按钮",{"key":24,"text":417,"correct":22},"带插孔的手报按钮",{"key":27,"text":419,"correct":22},"消防广播音响",{"key":31,"text":421,"correct":22},"消防电话",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":424,"answer":31,"analysis":33},891151,[425,427,429,431],{"key":20,"text":426,"correct":22},"信号阀",{"key":24,"text":428,"correct":22},"防火阀",{"key":27,"text":430,"correct":22},"干式报警阀",{"key":31,"text":432,"correct":29},"湿式报警阀",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":435,"answer":31,"analysis":33},891152,[436,437,439,441],{"key":20,"text":406,"correct":22},{"key":24,"text":438,"correct":22},"延迟器",{"key":27,"text":440,"correct":22},"水力警铃",{"key":31,"text":442,"correct":29},"压力开关",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":445,"answer":31,"analysis":33},891153,[446,448,449,451],{"key":20,"text":447,"correct":22},"防火卷帘",{"key":24,"text":388,"correct":22},{"key":27,"text":450,"correct":22},"局部等电位端子箱",{"key":31,"text":452,"correct":29},"总等电位端子箱",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":455,"answer":27,"analysis":33},891154,[456,458,460,462],{"key":20,"text":457,"correct":22},"手报按钮",{"key":24,"text":459,"correct":22},"消火栓启动按钮",{"key":27,"text":461,"correct":29},"防火卷帘按钮",{"key":31,"text":463,"correct":22},"气体灭火系统控制按钮",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":24,"analysis":33},891155,"下列关于消防水灭火系统定额执行中的注意事项，不正确的是（ ）。",[468,470,472,474],{"key":20,"text":469,"correct":22},"钢管（法兰连接）定额中包含管件及法兰安装，但管件.法兰数量应按设计图纸用量另行计算",{"key":24,"text":471,"correct":29},"集热罩安装项目主材不包括所配备的成品支架",{"key":27,"text":473,"correct":22},"减压孔板不论在法兰盘内.活接头内或消火栓接口内安装，均执行同一子目",{"key":31,"text":475,"correct":22},"报警装置安装项目定额中已包括装配管.泄放试验管及水力警铃出水管安装",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":31,"analysis":33},891156,"根据使用环境的不同，火灾自动报警系统采用不同的模式，下列说法错误的是（ ）。",[480,482,484,486],{"key":20,"text":481,"correct":22},"结构简单的小型建筑应采用区域报警系统",{"key":24,"text":483,"correct":22},"高层商务楼应采用集中报警系统",{"key":27,"text":485,"correct":22},"大型商业综合体应采用控制中心报警系统",{"key":31,"text":487,"correct":29},"超高层建筑应采用集中报警系统",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":31,"analysis":33},891157,"某图书馆重要书籍资料管理室应设置的灭火系统类别是（ ）。",[492,494,496,498],{"key":20,"text":493,"correct":22},"自动喷水灭火系统",{"key":24,"text":495,"correct":22},"泡沫灭火系统",{"key":27,"text":497,"correct":22},"消火栓系统",{"key":31,"text":499,"correct":29},"七氟丙烷灭火系统",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":31,"analysis":33},891158,"固定式泡沫灭火系统的泡沫喷射可分为液上喷射和液下喷射两种方式，液下喷射泡沫适用于（ ）。",[504,506,508,510],{"key":20,"text":505,"correct":22},"内浮顶储罐",{"key":24,"text":507,"correct":22},"外浮顶储罐",{"key":27,"text":509,"correct":22},"双盘外浮顶储罐",{"key":31,"text":511,"correct":29},"固定拱顶储罐",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":27,"analysis":33},891159,"自动喷水雨淋式灭火系统包括管道系统、雨淋阀、火灾探测器以及（ ）。",[516,517,519,521],{"key":20,"text":406,"correct":22},{"key":24,"text":518,"correct":22},"预作用阀",{"key":27,"text":520,"correct":29},"开式喷头",{"key":31,"text":522,"correct":22},"闭式喷头",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":27,"analysis":33},891160,"探测器是火灾自动报警系统中应用量最大、应用面最广的设备。下列选项中不符合点型探测器安装要求的是（ ）",[527,529,531,533],{"key":20,"text":528,"correct":22},"探测区域内的每个房间至少应设置一只火灾探测器",{"key":24,"text":530,"correct":22},"在宽度小于3m的走道顶棚上设置探测器时，宜居中布置",{"key":27,"text":532,"correct":29},"感温探测器的安装距离不超过15m,感烟探测器的安装间距不应超过10m",{"key":31,"text":534,"correct":22},"探测器周围0.5m内，不应有遮挡物。",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":24,"analysis":33},891161,"下列有关消防水泵接合器的作用，说法正确的是（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"灭火时通过消防水泵接合器接消防水带向室外供水灭火",{"key":24,"text":542,"correct":29},"火灾发生时消防车通过水泵接合器向室内管网供水灭火",{"key":27,"text":544,"correct":22},"灭火时通过水泵接合器给消防车供水",{"key":31,"text":546,"correct":22},"火灾发生时通过水泵接合器控制泵房消防水泵",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":549,"answer":27,"analysis":33},891162,[550,552,554,555],{"key":20,"text":551,"correct":22},"排烟口",{"key":24,"text":553,"correct":22},"送风口",{"key":27,"text":447,"correct":29},{"key":31,"text":556,"correct":22},"排风口",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":559,"answer":27,"analysis":33},891163,[560,561,563,564],{"key":20,"text":415,"correct":22},{"key":24,"text":562,"correct":22},"系统模块",{"key":27,"text":421,"correct":29},{"key":31,"text":419,"correct":22},{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":567,"answer":20,"analysis":33},891164,[568,569,571,572],{"key":20,"text":562,"correct":29},{"key":24,"text":570,"correct":22},"控制模块",{"key":27,"text":421,"correct":22},{"key":31,"text":406,"correct":22},{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":33},891165,"下列关于消防水灭火系统各主要组件的说法中，错误的是（ ）。",[577,579,581,583],{"key":20,"text":578,"correct":29},"建筑内给水管网通过水泵接合器向消防车送水加压",{"key":24,"text":580,"correct":22},"消防水箱需保证5~10min的灭火用水量",{"key":27,"text":582,"correct":22},"发生火灾且触发自动灭火系统后，消防水泵要在5min内启动",{"key":31,"text":584,"correct":22},"消防水泵应设有备用泵",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":27,"analysis":33},891166,"关于消防水灭火系统的说法中，错误的是（ ）。",[589,591,593,595],{"key":20,"text":590,"correct":22},"室外消火栓有地上式和地下式",{"key":24,"text":592,"correct":22},"室内消火栓由消火栓.水枪.水带.消防管道组成",{"key":27,"text":594,"correct":29},"自动喷水灭火系统中雨淋系统属于开式系统",{"key":31,"text":596,"correct":22},"水幕系统的作用不是喷水灭火",[598,601,604,607,610,613],{"id":15,"name":599,"category":7,"favorite":600},"领导干部任职前廉政法规知识测试题",92,{"id":602,"name":603,"category":7,"favorite":15},595,"建筑结构与设备",{"id":605,"name":606,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":608,"name":609,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":611,"name":612,"category":7,"favorite":8},534,"BIM工程师",{"id":614,"name":612,"category":7,"favorite":8},535]