[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-891669":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},891669,577,2,"多选题","液压试验的目的是检查设备或管道的强度和密封性能，液压试验的方法及要求包括（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","液压试验不可采用其他无毒液体进行液压试验",false,{"key":16,"text":17,"correct":18},"B","当采用可燃液体介质进行试验时，其闪点不得低于50℃，并应采取安全防护措施",true,{"key":20,"text":21,"correct":18},"C","碳素钢在液压试验时，液体温度不得低于5℃",{"key":23,"text":24,"correct":18},"D","对于不锈耐酸钢容器，试验用水的氯离子含量不应超过25×10－6",{"key":26,"text":27,"correct":14},"E","试验时，环境温度不宜低于10℃","BCD","液压试验应使用清洁水。当对不锈钢、镍及镍合金管道，或对连有不锈钢、镍及镍合金管道或设备的管道进行试验时，试验用水中氯离子含量不得超过25×10－6（25ppm）。也可采用其他无毒液体进行液压试验。当采用可燃液体介质进行试验时，其闪点不得低于50℃，并应采取安全防护措施。试验时，环境温度不宜低于5℃。当环境温度低于5℃时，应采取防冻措施。碳素钢、Q345R、Q370R制设备在液压试验时，液体温度不得低于5℃；其他低合金钢制设备液压试验时，液体温度不得低于15℃。",{"id":6,"name":31,"category":32,"favorite":33},"[安装工程]建设工程计量与计价实务","建筑工程",0]