[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-887671":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},887671,573,2,"多选题","为保证堤坝式电站在建设和运行期间不造成下游河道断流，必须考虑下泄生态流量的时期有（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","电站初期蓄水期间",true,{"key":16,"text":17,"correct":18},"B","电站正常发电过程中",false,{"key":20,"text":21,"correct":18},"C","电站机组部分停机时",{"key":23,"text":24,"correct":14},"D","电站机组全部停机时","AD","对于引水式电站，厂址间段会出现不同程度的脱水河段，其水生生态、用水设施和景观影响较大；对于日调节水电站，下泄流量、下游河段河水流速和水位在日内变化较大，对下游河道的航运和用水设施影响明显；对于年调节电站，水库水温分层相对稳定，下泄河水温度相对较低，对下游水生生物和农灌作物影响较大。生态流量，一般按10％（当多年平均流量小于80m3\u002Fs）或5％（当多年平均流量大于80m3\u002Fs），流量不会很大。水电站机组发电时，额定流量很大，一般都是三位数，足以满足下游生态流量。所以部分机组停机也不用考虑下游生态流量，单机发电的流量足以满足下游的流量。",{"id":6,"name":28,"category":29,"favorite":30},"环境影响评价技术方法","建筑工程",0]