[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-886185":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},886185,572,2,"多选题","根据《环境影响评价技术导则—地下水环境》，下列关于地下水水质样品采集与现场测定的说法，正确的有（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","应采用定深采样器进行采集",true,{"key":16,"text":17,"correct":14},"B","采集前应先测量井孔地下水水位",{"key":19,"text":20,"correct":14},"C","应进行全井孔清洗",{"key":22,"text":23,"correct":24},"D","特征因子应在现场测定",false,"ABC","根据《环境影响评价技术导则—地下水环境》（HJ 610—2016），地下水样品采集与现场测定的内容包括：①地下水样品应采用自动式采样泵或人工活塞闭合式与敞口式定深采样器进行采集；②样品采集前，应先测量井孔地下水水位（或地下水水位埋深）并做好记录，然后采用潜水泵或离心泵对采样井（孔）进行全井孔清洗，抽汲的水量不得小于3倍的井筒水（量）体积；③地下水水质样品的管理、分析化验和质量控制按照（HJ\u002FT 164）执行。PH、Eh、DO、水温等不稳定项目应在现场测定。",{"id":6,"name":28,"category":29,"favorite":30},"环境影响评价技术导则与标准","建筑工程",0]