[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-884889":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},884889,571,1,"单选题","两水池用虹吸管连接，管路如图所示。已知上下游水池的水位差H为2m，管长L1为3m，L2为5m，L3为4m，管径为100mm，沿程阻力系数为0.026，进口阻力系数为0.5，弯头阻力系数为1.5，出口阻力系数为1.0。求通过虹吸管的流量，并说明在上下游水位差不变的条件下，哪些措施可以提高虹吸管的流量？ A.Q=0.0178m3\u002Fs，减小虹吸管管径，可以增大出流量",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","Q=0.0178m3\u002Fs，减小虹吸管长度，可以增大出流量",false,{"key":16,"text":17,"correct":18},"B","Q=1.78m3\u002Fs，增大虹吸管管径，可以增大出流量",true,{"key":20,"text":21,"correct":14},"C","Q=1.78m3\u002Fs，减小虹吸管内壁的粗糙度，可以增大出流量",{"key":23,"text":24,"correct":14},"D","","提示 计算如下: 可知，减小虹吸管长度，可以增大流量。",{"id":6,"name":27,"category":28,"favorite":29},"注册环保工程师 - 专业基础","建筑工程",0]