[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":620},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,9,50,2054,[13,34,46,61,74,87,99,111,123,136,148,160,171,184,197,209,221,233,245,257,269,281,293,305,318,330,342,349,358,370,382,394,406,418,430,442,454,466,478,487,499,512,524,536,548,560,572,584,596,608],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},880251,1,"单选题","供暖系统供回水管道采用补偿器时，要优先采用下列哪种补偿器？( )",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","套筒补偿器",false,{"key":24,"text":25,"correct":22},"B","波纹管补偿器",{"key":27,"text":28,"correct":22},"C","球形补偿器",{"key":30,"text":31,"correct":32},"D","方形补偿器",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":30,"analysis":33},880252,"某工业厂房内的粉尘浓度为6mg\u002Fm3，该种粉尘的接触限值为8mg\u002Fm3，当该厂房的机械送风系统采用部分循环空气时，该系统送入工作场所的空气中粉尘浓度应不大于下列哪一项？",[38,40,42,44],{"key":20,"text":39,"correct":22},"4mg\u002Fm3",{"key":24,"text":41,"correct":22},"3mg\u002Fm3",{"key":27,"text":43,"correct":22},"2.5mg\u002Fm3",{"key":30,"text":45,"correct":32},"2mg\u002Fm3",{"id":47,"libraryId":5,"type":48,"typeLabel":49,"stem":50,"options":51,"answer":60,"analysis":33},880253,2,"多选题","下述关于高压蒸汽供暖系统凝结水管道的设计方法中，正确的是哪几项？",[52,54,56,58],{"key":20,"text":53,"correct":22},"疏水器前的凝结水管不宜向上抬升",{"key":24,"text":55,"correct":32},"疏水器后的凝结水管向上抬升的高度应经计算确定",{"key":27,"text":57,"correct":32},"靠疏水器余压流动的凝结水管路，疏水器后的背压最小压力不应小于50kPa",{"key":30,"text":59,"correct":32},"疏水器至回水箱的蒸汽凝结水管，应按汽水乳状体进行计算","BCD",{"id":62,"libraryId":5,"type":48,"typeLabel":49,"stem":63,"options":64,"answer":73,"analysis":33},880254,"气压给水设备水泵流量的确定，下列的哪些观念是正确的？( )",[65,67,69,71],{"key":20,"text":66,"correct":22},"不小于系统最大小时用水量",{"key":24,"text":68,"correct":32},"不小于系统最大小时用水量的1.2倍",{"key":27,"text":70,"correct":22},"对应于气压水罐设定上限工作压力时水泵工作点的流量",{"key":30,"text":72,"correct":32},"对应于气压水罐设定上下限平均工作压力时水泵工作点的流量","BD",{"id":75,"libraryId":5,"type":48,"typeLabel":49,"stem":76,"options":77,"answer":86,"analysis":33},880255,"与疏水器的设计排水量有关的参数，是下列哪几项？",[78,80,82,84],{"key":20,"text":79,"correct":32},"疏水器阀孔直径",{"key":24,"text":81,"correct":32},"疏水器前后压差",{"key":27,"text":83,"correct":32},"疏水器选择倍率",{"key":30,"text":85,"correct":22},"疏水器的背压","ABC",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":30,"analysis":33},880256,"设在二级耐火等级的多层建筑首层的商场，设有火灾报警系统和自动喷水灭火系统和排烟设施，装修符合现行国家标准GB50222-95《建筑内部装修设计防火规范》规定，防火分区最大允许建筑面积为( )。",[91,93,95,97],{"key":20,"text":92,"correct":22},"2000㎡",{"key":24,"text":94,"correct":22},"2500㎡",{"key":27,"text":96,"correct":22},"5000㎡",{"key":30,"text":98,"correct":32},"10000㎡",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":20,"analysis":33},880257,"空调监测与控制系统的流量传感器，其量程应为系统( )。",[103,105,107,109],{"key":20,"text":104,"correct":32},"最大工作流量的1.2～1.3倍",{"key":24,"text":106,"correct":22},"最大工作流量的1.2～1.5倍",{"key":27,"text":108,"correct":22},"平均工作流量的1.2～1.3倍",{"key":30,"text":110,"correct":22},"平均工作流量的1.2～1.5倍",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":33},880258,"制冷剂临界温度( )，便于用一般冷却水或空气进行冷凝液化。",[115,117,119,121],{"key":20,"text":116,"correct":32},"高",{"key":24,"text":118,"correct":22},"低",{"key":27,"text":120,"correct":22},"适当",{"key":30,"text":122,"correct":22},"无所谓",{"id":124,"libraryId":5,"type":48,"typeLabel":49,"stem":125,"options":126,"answer":135,"analysis":33},880259,"吸附法净化有害气体适用于( )。",[127,129,131,133],{"key":20,"text":128,"correct":32},"有害气体浓度较低",{"key":24,"text":130,"correct":22},"有害气体浓度较高",{"key":27,"text":132,"correct":32},"有害气体毒性较大",{"key":30,"text":134,"correct":32},"有害气体流量不宜过大","ACD",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":20,"analysis":33},880260,"采用直燃溴化锂吸收式冷热水机组制冷、制热时，与电动制冷机相比，其能源利用和能源转化效率为下列哪一项？( )",[140,142,144,146],{"key":20,"text":141,"correct":32},"一般",{"key":24,"text":143,"correct":22},"最好",{"key":27,"text":145,"correct":22},"最差",{"key":30,"text":147,"correct":22},"较优",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":27,"analysis":33},880261,"某热水采暖系统顶点的工作压力为0.15MPa，该采暖系统顶点的试验压力，应是下列哪一项？",[152,154,156,158],{"key":20,"text":153,"correct":22},"不应小于0.2MPa",{"key":24,"text":155,"correct":22},"不应小于0.25MPa",{"key":27,"text":157,"correct":32},"不应小于0.3MPa",{"key":30,"text":159,"correct":22},"不应小于0.35MPa",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":27,"analysis":33},880262,"高层建筑内地下展览厅，设有火灾自动报警系统和自动灭火系统，且采用不燃材料装修，其防火分区的最大允许建筑面积为( )。",[164,166,168,169],{"key":20,"text":165,"correct":22},"1000㎡",{"key":24,"text":167,"correct":22},"1500㎡",{"key":27,"text":92,"correct":32},{"key":30,"text":170,"correct":22},"4000㎡",{"id":172,"libraryId":5,"type":48,"typeLabel":49,"stem":173,"options":174,"answer":183,"analysis":33},880263,"空调系统可以采用电直接加热方式的情况是( )。",[175,177,179,181],{"key":20,"text":176,"correct":32},"对于室内温度控制精度要求高的实验室，空调系统采用电加热器进行微调",{"key":24,"text":178,"correct":32},"夏热冬暖地区短期使用的实验室，对温度控制精度有一定要求，采用电加热器作为空调系统的加热热源",{"key":27,"text":180,"correct":22},"严寒地区五星级宾馆的空调新风系统，为了防冻，采用电加热器进行预热",{"key":30,"text":182,"correct":32},"严寒气候区无集中供暖的某风景区，其中有国家级文物保护建筑，相关部门不允许采用燃煤、燃油和燃气锅炉，其空调系统采用电加热器进行供暖","ABD",{"id":185,"libraryId":5,"type":48,"typeLabel":49,"stem":186,"options":187,"answer":196,"analysis":33},880264,"适用于垂直单管跨越式系统的用户热分摊方法包括下列哪几项？( )",[188,190,192,194],{"key":20,"text":189,"correct":32},"散热器热分配计法",{"key":24,"text":191,"correct":32},"流量温度法",{"key":27,"text":193,"correct":22},"通断时间面积法",{"key":30,"text":195,"correct":22},"户用热量表法","AB",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":20,"analysis":33},880265,"当热负荷主要是蒸汽或热水负荷时，冷热电三联供系统余热设备宜采用( )。",[201,203,205,207],{"key":20,"text":202,"correct":32},"余热锅炉",{"key":24,"text":204,"correct":22},"吸收式冷(温)水机组",{"key":27,"text":206,"correct":22},"板式换热器",{"key":30,"text":208,"correct":22},"以上均可",{"id":210,"libraryId":5,"type":48,"typeLabel":49,"stem":211,"options":212,"answer":73,"analysis":33},880266,"关于冷凝温度和蒸发温度对压缩机的影响，下列说法正确的是( )。",[213,215,217,219],{"key":20,"text":214,"correct":22},"当冷凝温度升高，蒸发温度不变，则压缩机的输气系数、摩擦效率、指标效率均下降",{"key":24,"text":216,"correct":32},"当冷凝温度升高，蒸发温度不变，则压缩机的输气系数、摩擦效率、指标效率均上升",{"key":27,"text":218,"correct":22},"当蒸发温度降低，冷凝温度不变，则压缩机的输气系数、摩擦效率、指标效率均上升",{"key":30,"text":220,"correct":32},"当蒸发温度降低，冷凝温度不变，则压缩机的输气系数、摩擦效率、指标效率均下降",{"id":222,"libraryId":5,"type":48,"typeLabel":49,"stem":223,"options":224,"answer":196,"analysis":33},880267,"亲水性过滤器不宜直接设在下列哪些组件后面？( )",[225,227,229,231],{"key":20,"text":226,"correct":32},"淋水室",{"key":24,"text":228,"correct":32},"加湿室",{"key":27,"text":230,"correct":22},"加热室",{"key":30,"text":232,"correct":22},"中间室",{"id":234,"libraryId":5,"type":48,"typeLabel":49,"stem":235,"options":236,"answer":135,"analysis":33},880268,"下列关于空调冷源选择的说法，不正确的是( )。",[237,239,241,243],{"key":20,"text":238,"correct":32},"由于在制冷量较大的情况下，离心式冷水机组的能效比比螺杆式冷水机组高，因此应采用单台离心式冷水机组取代总制冷量相同的两台螺杆式冷水机组",{"key":24,"text":240,"correct":22},"不能以设计工况下能效比最高为依据来选择冷水机组",{"key":27,"text":242,"correct":32},"离心式冷水机组的调节性能好，机组制冷量可以从100%连续调节到25%，因此在调节性能要求高的情况下，应选用离心式冷水机组",{"key":30,"text":244,"correct":32},"部分负荷的情况下，冷水机组的制冷效率下降，因此应尽可能采用双机或多机并联设计",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":24,"analysis":33},880269,"分体式空调器在室外环境温度比较低的条件下，不能进行制热工况运行，其主要原因是下列哪一项？",[249,251,253,255],{"key":20,"text":250,"correct":22},"润滑油黏度太大，致使压缩机不能正常运行",{"key":24,"text":252,"correct":32},"压缩机排气温度过高，致使压缩机不能正常运行",{"key":27,"text":254,"correct":22},"不能保证室内空气温度要求",{"key":30,"text":256,"correct":22},"制热效率太低，经济不合算",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":27,"analysis":33},880270,"空调夏季设计热负荷的概算值与下列哪个因素无关？( )",[261,263,265,267],{"key":20,"text":262,"correct":22},"空调冷指标",{"key":24,"text":264,"correct":22},"建筑物的建筑面积",{"key":27,"text":266,"correct":32},"空调热指标",{"key":30,"text":268,"correct":22},"吸收式制冷机的制冷系数",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":30,"analysis":33},880271,"某小型办公楼采用风机盘管+新风的空调设计方案，空调水系统冬夏季共用，采用一级泵变频调节方案，水系统管路采用异程布置方案，下列说法中正确的是( )。",[273,275,277,279],{"key":20,"text":274,"correct":22},"在空调水系统各主要环路均设置动态平衡阀",{"key":24,"text":276,"correct":22},"在空调水系统各主要环路均设置定流量动态平衡阀",{"key":27,"text":278,"correct":22},"在空调水系统各主要环路均设置静态平衡阀",{"key":30,"text":280,"correct":32},"在空调水系统各主要环路均不设置平衡阀",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":30,"analysis":33},880272,"空调房间内回风口的位置，对气流组织影响比较小的根本原因为下列哪一项？( )",[285,287,289,291],{"key":20,"text":286,"correct":22},"回风口常处于房间不重要的位置",{"key":24,"text":288,"correct":22},"回风口的数量一般较送风口少",{"key":27,"text":290,"correct":22},"随着离开回风口距离的增加，吸风速度呈距离的四次幂衰减",{"key":30,"text":292,"correct":32},"随着离开回风口距离的增加，吸风速度与距离呈二次幂衰减",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":24,"analysis":33},880273,"当空调系统采甩低温送风方式时，空调冷水供水温度不宜高于( )。",[297,299,301,303],{"key":20,"text":298,"correct":22},"4℃",{"key":24,"text":300,"correct":32},"5℃",{"key":27,"text":302,"correct":22},"6℃",{"key":30,"text":304,"correct":22},"7℃",{"id":306,"libraryId":5,"type":48,"typeLabel":49,"stem":307,"options":308,"answer":317,"analysis":33},880274,"关于“下进上出”式氨泵供液系统，下列说法正确的是( )。",[309,311,313,315],{"key":20,"text":310,"correct":22},"充液量比“上进下出”式少",{"key":24,"text":312,"correct":32},"由于氨液通过氨泵输送，即使在并联支路较多的情况下也容易做到均匀配液",{"key":27,"text":314,"correct":32},"库房温度达到设定值停止供液后，由于排管中的液体不能自行排出，残留的氨液仍要继续汽化吸热，使库温继续下降，因此给准确控制库温带来一定的困难",{"key":30,"text":316,"correct":22},"在停止供液后排管中的氨液立即自行流至低压循环桶，不存在残留氨液继续汽化吸热降温的问题，因此可以较准确地控制库温，易于实现自动控制","BC",{"id":319,"libraryId":5,"type":48,"typeLabel":49,"stem":320,"options":321,"answer":86,"analysis":33},880275,"关于第二类吸收式热泵，以下说法正确的是( )。",[322,324,326,328],{"key":20,"text":323,"correct":32},"热泵的蒸发压力高于冷凝压力",{"key":24,"text":325,"correct":32},"可以利用低于输出热温度的热源作为驱动热源",{"key":27,"text":327,"correct":32},"冷却源温度越低，对驱动热源品位要求越低",{"key":30,"text":329,"correct":22},"因供热性能系数低，节能效果低于第一类吸收式热泵",{"id":331,"libraryId":5,"type":48,"typeLabel":49,"stem":332,"options":333,"answer":183,"analysis":33},880276,"关于蓄冷空调冷水供水温度，下列哪几项说法是正确的?( )。",[334,336,338,340],{"key":20,"text":335,"correct":32},"水蓄冷空调供水温度采用4～8℃",{"key":24,"text":337,"correct":32},"共晶盐蓄冷空调供水温度采用7～10℃",{"key":27,"text":339,"correct":22},"内融冰盘管蓄冷空调供水温度采用2～5℃",{"key":30,"text":341,"correct":32},"封装式冰蓄冷空调供水温度采用3～6℃",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":344,"answer":30,"analysis":33},880277,[345,346,347,348],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":32},{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":27,"analysis":33},880278,"逆卡诺循环的制冷系数与( )有关。",[353,355,356,357],{"key":20,"text":354,"correct":22},"制冷剂性质",{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":32},{"key":30,"text":33,"correct":22},{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},880279,"天窗局部阻力系数ζ反映了天窗在一定压差下的通风能力，ζ大，通风能力( )。",[362,364,366,368],{"key":20,"text":363,"correct":22},"大",{"key":24,"text":365,"correct":32},"小",{"key":27,"text":367,"correct":22},"根据压差大小不同变化",{"key":30,"text":369,"correct":22},"根据压差正负不同变化",{"id":371,"libraryId":5,"type":48,"typeLabel":49,"stem":372,"options":373,"answer":60,"analysis":33},880280,"洁净室运行管理工作中，对核心的物品，例如高效空气过滤器应该及时更换。需及时更换高效空气过滤器的情况是( )。",[374,376,378,380],{"key":20,"text":375,"correct":22},"高效空气过滤器安装已经2年以上",{"key":24,"text":377,"correct":32},"气流流速降低到最低限度，及时更换粗、中效空气过滤器以后，气流流速仍不能增大",{"key":27,"text":379,"correct":32},"高效空气过滤器的阻力达到初阻力的1.5～2.0倍",{"key":30,"text":381,"correct":32},"高效空气过滤器出现无法修补的渗漏",{"id":383,"libraryId":5,"type":48,"typeLabel":49,"stem":384,"options":385,"answer":196,"analysis":33},880281,"逆卡诺循环由( )组成。",[386,388,390,392],{"key":20,"text":387,"correct":32},"两个等温过程",{"key":24,"text":389,"correct":32},"两个等熵过程",{"key":27,"text":391,"correct":22},"两个等压过程",{"key":30,"text":393,"correct":22},"两个等焓过程",{"id":395,"libraryId":5,"type":48,"typeLabel":49,"stem":396,"options":397,"answer":183,"analysis":33},880282,"螺杆式、离心式冷水机组，名义制冷工况条件下进行性能试验时，关于性能的最大偏差数值，正确的应是下列哪几项？( )",[398,400,402,404],{"key":20,"text":399,"correct":32},"机组制冷量不应小于名义规定值的95%",{"key":24,"text":401,"correct":32},"机组消耗总电功率不应大于机组名义消耗电功率的110%",{"key":27,"text":403,"correct":22},"名义制冷工况的性能系数不应小于机组名义值的95%",{"key":30,"text":405,"correct":32},"冷水、冷却水的压力损失不应大于机组名义规定值的115%",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":30,"analysis":33},880283,"散热器表面涂刷瓷漆时的散热量比刷银粉漆时的散热量大，其原因是( )。",[410,412,414,416],{"key":20,"text":411,"correct":22},"涂刷瓷漆能提高散热器表面温度",{"key":24,"text":413,"correct":22},"涂刷瓷漆能减小表面污垢热阻",{"key":27,"text":415,"correct":22},"涂刷瓷漆能增强表面对流放热",{"key":30,"text":417,"correct":32},"涂刷瓷漆能增强表面辐射放热",{"id":419,"libraryId":5,"type":48,"typeLabel":49,"stem":420,"options":421,"answer":73,"analysis":33},880284,"《公建节能》中“窗墙面积比”的含义正确的是( )。",[422,424,426,428],{"key":20,"text":423,"correct":22},"某一朝向的外窗总面积与同朝向墙面面积(不包括窗面积在内)之比",{"key":24,"text":425,"correct":32},"某一朝向的外窗总面积与同朝向墙面总面积(包括窗面积在内)之比",{"key":27,"text":427,"correct":22},"外窗总面积中包括玻璃幕墙",{"key":30,"text":429,"correct":32},"外窗总面积中包括幕墙中的透明部分",{"id":431,"libraryId":5,"type":48,"typeLabel":49,"stem":432,"options":433,"answer":317,"analysis":33},880285,"以下有关于旋风除尘器、袋式除尘器和静电除尘器有关性能的叙述，下列哪几项是正确的？",[434,436,438,440],{"key":20,"text":435,"correct":22},"旋风除尘器的分割粒径越大，旋风除尘器的效率越高",{"key":24,"text":437,"correct":32},"旋风除尘器的压力损失与其进口速度的平方成正比",{"key":27,"text":439,"correct":32},"袋式除尘器过滤层的压力损失与过滤速度成正比",{"key":30,"text":441,"correct":22},"粉尘的比电阻超过1011～1012Ω·cm时，静电除尘器的除尘效率增高",{"id":443,"libraryId":5,"type":48,"typeLabel":49,"stem":444,"options":445,"answer":317,"analysis":33},880286,"关于空调水管材料的选择表述中，错误的是( )。",[446,448,450,452],{"key":20,"text":447,"correct":22},"铜管比较光滑，与钢管相比，其流动阻力损失较小，因此水泵能耗较小",{"key":24,"text":449,"correct":32},"由于废钢管可以回收，而塑料水管不能回收，因此从环保角度来说，空调水管不应采用塑料管",{"key":27,"text":451,"correct":32},"铜管流动阻力小、耐腐蚀、可回收再生，因此空调水管应采用铜管代替钢管",{"key":30,"text":453,"correct":22},"由于PVC管的导热性能差，因此冷凝水管宜采用PVC管",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":24,"analysis":33},880287,"溴化锂溶液中加入表面活性剂是为了( )。",[458,460,462,464],{"key":20,"text":459,"correct":22},"防止溴化锂溶液对设备的腐蚀",{"key":24,"text":461,"correct":32},"强化传热传质过程",{"key":27,"text":463,"correct":22},"减小溴化锂溶液的流动阻力",{"key":30,"text":465,"correct":22},"提高机组的真空度",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":27,"analysis":33},880288,"在国家标准《多联机空调(热泵)机组能效限定值及能源效率等级》GB214542008中，关于多联机能效等级的分级，正确的是下列哪一项？",[470,472,474,476],{"key":20,"text":471,"correct":22},"能效等级共分为3级，其中1级为能效最高级",{"key":24,"text":473,"correct":22},"能效等级共分为4级，其中l级为能效最高级",{"key":27,"text":475,"correct":32},"能效等级共分为5级，其中1级为能效最高级",{"key":30,"text":477,"correct":22},"能效等级共分为5级，其中5级为能效最高级",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},880289,"地下车库的通风系统节能运行，宜根据车库内的某种气体浓度进行自动运行控制，该种气体应是下列哪一项？( )",[482,483,485,486],{"key":20,"text":33,"correct":22},{"key":24,"text":484,"correct":32},"CO",{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":22},{"id":488,"libraryId":5,"type":48,"typeLabel":49,"stem":489,"options":490,"answer":60,"analysis":33},880290,"某除尘系统带有一个吸尘口，风机的全压为2800Pa，系统调试时，发现在吸尘口处无空气流动。可能形成该问题的原因，应是下列选项中的哪几项？",[491,493,495,497],{"key":20,"text":492,"correct":22},"除尘系统管路风速过高",{"key":24,"text":494,"correct":32},"风机的电机的电源相线接反",{"key":27,"text":496,"correct":32},"风机的叶轮装反",{"key":30,"text":498,"correct":32},"除尘系统管路上的斜插板阀处于关闭状态",{"id":500,"libraryId":5,"type":48,"typeLabel":49,"stem":501,"options":502,"answer":511,"analysis":33},880291,"余隙容积对压缩机的影响是( )。",[503,505,507,509],{"key":20,"text":504,"correct":32},"制冷量下降",{"key":24,"text":506,"correct":22},"压力比增加",{"key":27,"text":508,"correct":32},"压缩机的实际输气量减小",{"key":30,"text":510,"correct":22},"气体流动损失增加","AC",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":20,"analysis":33},880292,"冰蓄冷的低温送风系统中，可提供的空调冷水温度是( )。",[516,518,520,522],{"key":20,"text":517,"correct":32},"1.5～4℃",{"key":24,"text":519,"correct":22},"2～6℃",{"key":27,"text":521,"correct":22},"3～6℃",{"key":30,"text":523,"correct":22},"4～7℃",{"id":525,"libraryId":5,"type":48,"typeLabel":49,"stem":526,"options":527,"answer":86,"analysis":33},880293,"空气调节区围护结构的最大传热系数与( )有关。",[528,530,532,534],{"key":20,"text":529,"correct":32},"围护结构类别",{"key":24,"text":531,"correct":32},"空气调节类别",{"key":27,"text":533,"correct":32},"室温允许波动范围",{"key":30,"text":535,"correct":22},"窗墙比",{"id":537,"libraryId":5,"type":48,"typeLabel":49,"stem":538,"options":539,"answer":135,"analysis":33},880294,"对制冷剂的主要热力学性能的要求有下列哪几项？( )",[540,542,544,546],{"key":20,"text":541,"correct":32},"标准大气压沸点要低于所要求达到的制冷温度",{"key":24,"text":543,"correct":22},"冷凝压力越低越好",{"key":27,"text":545,"correct":32},"单位容积汽化潜热要大",{"key":30,"text":547,"correct":32},"临界点要高",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":20,"analysis":33},880295,"下列应用地埋管地源热泵系统的建筑，可不进行岩土热响应实验的是( )。",[552,554,556,558],{"key":20,"text":553,"correct":32},"应用建筑面积≤4000㎡",{"key":24,"text":555,"correct":22},"应用建筑面积≥5000㎡",{"key":27,"text":557,"correct":22},"应用建筑面积≥8000㎡",{"key":30,"text":559,"correct":22},"应用建筑面积≥10000㎡",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":30,"analysis":33},880296,"关于房间空调器的说法中，正确的是( )。",[564,566,568,570],{"key":20,"text":565,"correct":22},"EER低于2.6的分体壁挂空调器，经济实惠，符合中国国情，因此可以继续生产销售",{"key":24,"text":567,"correct":22},"一台额定制冷量为3200W的分体壁挂空调器，其额定能效比为3.2，它是节能型空调器",{"key":27,"text":569,"correct":22},"变频空调器的夏季运行能耗一定比定频空调器低",{"key":30,"text":571,"correct":32},"1级空调器的额定能效比一定比3级空调器高",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":27,"analysis":33},880297,"部分负荷蓄冰时，一般最佳的蓄冷比例以( )为宜。",[576,578,580,582],{"key":20,"text":577,"correct":22},"40%～80%",{"key":24,"text":579,"correct":22},"40%～70%",{"key":27,"text":581,"correct":32},"30%～70%",{"key":30,"text":583,"correct":22},"30%～60%",{"id":585,"libraryId":5,"type":48,"typeLabel":49,"stem":586,"options":587,"answer":73,"analysis":33},880298,"空气源热泵型冷热水机组用于洛阳市，当地夏季空调室外计算干球温度35.9℃，冬季室外计算干球温度-7℃，正确的说法应是下列哪几项？( )",[588,590,592,594],{"key":20,"text":589,"correct":22},"夏季设计条件时，机组的供冷量高于其额定供冷量",{"key":24,"text":591,"correct":32},"夏季设计条件时，机组的供冷量低于其额定供冷量",{"key":27,"text":593,"correct":22},"冬季设计条件时，机组的供热量高于其额定供热量",{"key":30,"text":595,"correct":32},"冬季设计条件时，机组的供热量低于其额定供热量",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":24,"analysis":33},880299,"管径为150mm的排水管道上设置的清扫口管径为( )mm。",[600,602,604,606],{"key":20,"text":601,"correct":22},"50",{"key":24,"text":603,"correct":32},"75",{"key":27,"text":605,"correct":22},"90",{"key":30,"text":607,"correct":22},"100",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":27,"analysis":33},880300,"通风机直通大气的进出口处必须设( )。",[612,614,616,618],{"key":20,"text":613,"correct":22},"弯头",{"key":24,"text":615,"correct":22},"软管",{"key":27,"text":617,"correct":32},"防护罩(网)或其他安全设施",{"key":30,"text":619,"correct":22},"阀门",[621,624,627,630,633,636],{"id":15,"name":622,"category":7,"favorite":623},"领导干部任职前廉政法规知识测试题",92,{"id":625,"name":626,"category":7,"favorite":15},595,"建筑结构与设备",{"id":628,"name":629,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":631,"name":632,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":634,"name":635,"category":7,"favorite":8},534,"BIM工程师",{"id":637,"name":635,"category":7,"favorite":8},535]