[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":624},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,7,50,2054,[13,33,45,57,69,81,93,104,116,124,136,151,164,177,189,202,214,227,240,252,265,278,290,302,314,326,338,350,362,374,386,394,406,418,430,443,455,467,479,491,503,515,528,540,552,564,576,588,600,612],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":17},880151,1,"单选题","",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","A点",false,{"key":24,"text":25,"correct":22},"B","B点",{"key":27,"text":28,"correct":22},"C","C点",{"key":30,"text":31,"correct":32},"D","D点",true,{"id":34,"libraryId":5,"type":15,"typeLabel":16,"stem":35,"options":36,"answer":27,"analysis":17},880152,"为达到国家规定的排放标准，铸造化铁用冲天炉除尘设计采用了带高温烟气冷却装置的旋风除尘器十袋式除尘器两级除尘系统，关于该除尘系统的表述，下列哪项是错误的？",[37,39,41,43],{"key":20,"text":38,"correct":22},"第一级除尘的旋风除尘器的收尘量要多于第二级袋式除尘器的收尘量",{"key":24,"text":40,"correct":22},"旋风除尘器重要作用之一是去除高温烟气中的粗颗粒烟尘",{"key":27,"text":42,"correct":32},"烟气温度超过袋式除尘器规定的上限温度时，只采用旋风除尘器除尘",{"key":30,"text":44,"correct":22},"烟气温度不超过袋式除尘器的设计上限温度，却出现了袋式除尘器的布袋烧损现象，原因是烟尘的温度高于烟气温度所致",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":27,"analysis":17},880153,"某热水集中连续供暖系统，总供热容量为20MW，供回水设计温差为25℃，每日供热18h，供回水主干管长度2000m，根据《民用建筑节能设计标准》(JGJ26-1995)的规定，耗电输热比不应大于0.0062，循环水泵允许的最大铭牌轴功率为( )kW。",[49,51,53,55],{"key":20,"text":50,"correct":22},"140～150",{"key":24,"text":52,"correct":22},"151～160",{"key":27,"text":54,"correct":32},"161～170",{"key":30,"text":56,"correct":22},"171～180",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":20,"analysis":17},880154,"某高层建筑有地面面积为800㎡、净空高度为11.5m的中庭，设计采用自然排烟方式。该中庭可开启的天窗面积的数值哪一项是错误的？",[61,63,65,67],{"key":20,"text":62,"correct":32},"16㎡",{"key":24,"text":64,"correct":22},"40㎡",{"key":27,"text":66,"correct":22},"80㎡",{"key":30,"text":68,"correct":22},"120㎡",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":30,"analysis":17},880155,"设置集中热风采暖的工业建筑，送风系统的送风口安装高度为4.5m，其冬季的送风温度￡应是下列哪一项？",[73,75,77,79],{"key":20,"text":74,"correct":22},"45℃≤℃≤60℃",{"key":24,"text":76,"correct":22},"35℃≤℃≤60℃",{"key":27,"text":78,"correct":22},"45℃≤t≤70℃",{"key":30,"text":80,"correct":32},"35℃≤℃≤70℃",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":30,"analysis":17},880156,"下列关于空调机组表冷器的表述中，不正确的是( )。",[85,87,89,91],{"key":20,"text":86,"correct":22},"表冷器可以实现等d冷却，这时的热湿比为一∞",{"key":24,"text":88,"correct":22},"表冷器可以实现减d冷却，这时的热湿比大于0",{"key":27,"text":90,"correct":22},"表冷器不可能实现增焓减湿",{"key":30,"text":92,"correct":32},"当表冷器出现冷凝水时，其出口空气达到饱和状态，相对湿度达到100%",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":95,"answer":27,"analysis":17},880157,[96,98,100,102],{"key":20,"text":97,"correct":22},"实际制冷量大于额定制冷量",{"key":24,"text":99,"correct":22},"实际制冷量等于额定制冷量",{"key":27,"text":101,"correct":32},"实际制冷量小于额定制冷量",{"key":30,"text":103,"correct":22},"无法判断",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":24,"analysis":17},880158,"关于风机盘管加新风空调系统的表述中，不正确的是( )。",[108,110,112,114],{"key":20,"text":109,"correct":22},"风机盘管空调系统存在漏水的危险，不能用于重要机房",{"key":24,"text":111,"correct":32},"风机盘管的凝结水易滋生细菌，影响人体健康，因此它不宜用于写字楼和宾馆",{"key":27,"text":113,"correct":22},"风机盘管空调系统的能耗通常比全空气空调系统少",{"key":30,"text":115,"correct":22},"风机盘管空调系统调节性较好，适用于各房间温度需要独立控制的情况",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":20,"analysis":17},880159,"某建筑全年运行的地埋管地源热泵冷热水机组，土壤可实现全年热平衡，经过一个制冷期和一个供暖期的运行，反映土壤温度变化的曲线，下列哪一项是正确的？(不考虑土壤温度自然恢复情况)",[120,121,122,123],{"key":20,"text":17,"correct":32},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":27,"analysis":17},880160,"机械循环热水供暖系统的恒压点(膨胀水箱膨胀管或补水定压装置的补水管与系统的接点)，当设置于循环水泵的吸入口处，循环水泵运行时，( )。",[128,130,132,134],{"key":20,"text":129,"correct":22},"系统的各点工作压力均会高于静压，升高值为循环水泵的铭牌扬程",{"key":24,"text":131,"correct":22},"系统的各点工作压力均会高于静压，升高值为循环水泵工作点的扬程",{"key":27,"text":133,"correct":32},"系统的各点工作压力均会高于静压，各点的升高值是不同的",{"key":30,"text":135,"correct":22},"系统供水管的工作压力均会高于静压，回水管的工作压力均会低于静压，波动值为循环水泵工作点的扬程",{"id":137,"libraryId":5,"type":138,"typeLabel":139,"stem":140,"options":141,"answer":150,"analysis":17},880161,2,"多选题","设计某城市住宅小区供热锅炉房，正确选择锅炉的原则应是下列哪几项？",[142,144,146,148],{"key":20,"text":143,"correct":22},"选用额定热效率不低于75%的燃煤热水锅炉",{"key":24,"text":145,"correct":22},"选用额定热效率不低于85%的燃气热水锅炉",{"key":27,"text":147,"correct":32},"选用额定热效率不低于78%的燃煤热水锅炉",{"key":30,"text":149,"correct":32},"不选用沸腾锅炉","CD",{"id":152,"libraryId":5,"type":138,"typeLabel":139,"stem":153,"options":154,"answer":163,"analysis":17},880162,"可以实现空气处理后含湿量减少的空气处理设备，应是下列哪几项？( )",[155,157,159,161],{"key":20,"text":156,"correct":22},"电加热器",{"key":24,"text":158,"correct":32},"表面式空气冷却器",{"key":27,"text":160,"correct":32},"喷水室",{"key":30,"text":162,"correct":22},"表面式空气加热器","BC",{"id":165,"libraryId":5,"type":138,"typeLabel":139,"stem":166,"options":167,"answer":176,"analysis":17},880163,"下列因素中，哪几项与确定建筑物内给水的最高日用水量无关？( )",[168,170,172,174],{"key":20,"text":169,"correct":32},"给水管网的工作压力",{"key":24,"text":171,"correct":22},"最高日用水定额",{"key":27,"text":173,"correct":32},"用水小时变化系数",{"key":30,"text":175,"correct":32},"每日用水时间","ACD",{"id":178,"libraryId":5,"type":138,"typeLabel":139,"stem":179,"options":180,"answer":176,"analysis":17},880164,"制冷系统自动控制的主要环节包含( )。",[181,183,185,187],{"key":20,"text":182,"correct":32},"联锁控制",{"key":24,"text":184,"correct":22},"电话通讯、远程控制",{"key":27,"text":186,"correct":32},"保护控制",{"key":30,"text":188,"correct":32},"制冷机组自身的运行控制和保护控制",{"id":190,"libraryId":5,"type":138,"typeLabel":139,"stem":191,"options":192,"answer":201,"analysis":17},880165,"某夏热冬冷地区南区的7层住宅，按照节能设计标准的规定，在下列哪些情况下，应进行“节能综合指标”的计算和判定？( )",[193,195,197,199],{"key":20,"text":194,"correct":22},"建筑物的体形系数为0.35",{"key":24,"text":196,"correct":32},"南向窗墙面积比为0.50",{"key":27,"text":198,"correct":32},"全部采用传热系数为5.0W\u002F(㎡·K)的外窗",{"key":30,"text":200,"correct":32},"外墙的热惰性指标2.5，传热系数1.2W\u002F(㎡·K)；屋顶的热惰性指标3.0，传热系数0.9W\u002F(㎡·K)","BCD",{"id":203,"libraryId":5,"type":138,"typeLabel":139,"stem":204,"options":205,"answer":201,"analysis":17},880166,"下列关于射流特性的说法，正确的是( )。",[206,208,210,212],{"key":20,"text":207,"correct":22},"紊流因数的大小与射流出口截面上的速度分布有关，分布愈不均匀，紊流因数愈小",{"key":24,"text":209,"correct":32},"紊流因数直接影响射流发展的快慢，紊流因数大，横向脉动大，射流扩散角就大，射程就短",{"key":27,"text":211,"correct":32},"要想增大射程，可以提高出口速度或者减少紊流因数",{"key":30,"text":213,"correct":32},"要想增大射流扩散角，可以选用紊流因数较大的送风口",{"id":215,"libraryId":5,"type":138,"typeLabel":139,"stem":216,"options":217,"answer":226,"analysis":17},880167,"有关冷库冷间的设备选择，正确的说法是下列哪几项？",[218,220,222,224],{"key":20,"text":219,"correct":32},"冷却间的冷却设备应采用空气冷却器",{"key":24,"text":221,"correct":32},"冷却物冷藏间的冷却设备应采用空气冷却器",{"key":27,"text":223,"correct":22},"冻结物冷藏间的冷却设备应采用空气冷却器",{"key":30,"text":225,"correct":22},"包装间的冷却设备应采用空气冷却器","AB",{"id":228,"libraryId":5,"type":138,"typeLabel":139,"stem":229,"options":230,"answer":239,"analysis":17},880168,"在用天然气为燃料的锅炉房事故排风系统设计时，下列哪几项是正确的？",[231,233,235,237],{"key":20,"text":232,"correct":32},"排风机应采用防爆风机",{"key":24,"text":234,"correct":22},"排出室外的排风口应低于室外进风口2m",{"key":27,"text":236,"correct":22},"排出室外的排风口应低于室外进风口6m",{"key":30,"text":238,"correct":32},"室内排风口应高于房间地面2m以上","AD",{"id":241,"libraryId":5,"type":138,"typeLabel":139,"stem":242,"options":243,"answer":239,"analysis":17},880169,"室内温度小于室外温度，仅有热压作用的自然通风时，下列关于中和界的叙述中正确的是( )。",[244,246,248,250],{"key":20,"text":245,"correct":32},"中和界是指余压为零的水平面",{"key":24,"text":247,"correct":22},"中和界以上余压为正，中和界以下余压为负",{"key":27,"text":249,"correct":22},"中和界以上的孔口向室外排风",{"key":30,"text":251,"correct":32},"离中和界的垂直距离越大，孔口通风能力越强",{"id":253,"libraryId":5,"type":138,"typeLabel":139,"stem":254,"options":255,"answer":264,"analysis":17},880170,"下列可作为水平防火分隔措施的是( )。",[256,258,260,262],{"key":20,"text":257,"correct":32},"防火墙",{"key":24,"text":259,"correct":32},"防火卷帘",{"key":27,"text":261,"correct":32},"防火窗",{"key":30,"text":263,"correct":32},"防火门","ABCD",{"id":266,"libraryId":5,"type":138,"typeLabel":139,"stem":267,"options":268,"answer":277,"analysis":17},880171,"采用单级蒸气压缩式制冷，当蒸发温度过低时，则需要采用双级压缩式制冷循环，采用该做法的原因应是下列哪几项？( )",[269,271,273,275],{"key":20,"text":270,"correct":32},"避免制冷系数降低过多",{"key":24,"text":272,"correct":32},"避免制冷剂单位质量制冷量下降过大",{"key":27,"text":274,"correct":32},"受到压缩机的排气压力与吸气压力之比数值的限制",{"key":30,"text":276,"correct":22},"避免设备的体积过大","ABC",{"id":279,"libraryId":5,"type":138,"typeLabel":139,"stem":280,"options":281,"answer":176,"analysis":17},880172,"关于海水源热泵空调系统设计方法中，不正确的是( )。",[282,284,286,288],{"key":20,"text":283,"correct":32},"海水设计温度应取近10年取水点区域的海水温度",{"key":24,"text":285,"correct":22},"取水口距海底高度宜大于2.5m",{"key":27,"text":287,"correct":32},"应进行冬夏季的总释热量和总吸热量的平衡验算",{"key":30,"text":289,"correct":32},"为了防止堵塞，海水的取水口处不应设置过滤器",{"id":291,"libraryId":5,"type":138,"typeLabel":139,"stem":292,"options":293,"answer":201,"analysis":17},880173,"关于自然通风建筑形式，下列说法正确的是( )。",[294,296,298,300],{"key":20,"text":295,"correct":22},"为保证建筑的自然通风效果，建筑的主要进风面一般应与夏季主导风向呈60°～90°角，不宜大于45°角",{"key":24,"text":297,"correct":32},"提高自然通风降温效果，应尽量降低进风侧窗距地面高度，一般不宜超过1.2m",{"key":27,"text":299,"correct":32},"散热量大的热源应尽量布置在厂房外面，夏季主导风向的下风侧。布置在室内的热源，应采取有效的隔热降温措施",{"key":30,"text":301,"correct":32},"夏季自然通风应采用流量系数大、易于操作和维修的进、排风口或窗扇",{"id":303,"libraryId":5,"type":138,"typeLabel":139,"stem":304,"options":305,"answer":201,"analysis":17},880174,"下列节约用水措施错误的是( )。",[306,308,310,312],{"key":20,"text":307,"correct":22},"合理配置水表等计量装置",{"key":24,"text":309,"correct":32},"减少高层建筑给水系统的压力分区",{"key":27,"text":311,"correct":32},"提高用水器具的配水压力",{"key":30,"text":313,"correct":32},"给水泵房和吸水水池尽量布置在地下较低的部位",{"id":315,"libraryId":5,"type":138,"typeLabel":139,"stem":316,"options":317,"answer":163,"analysis":17},880175,"气压给水设备供水系统中所需要的气压水罐的调节容积，与下列哪些因素有关？( )",[318,320,322,324],{"key":20,"text":319,"correct":22},"用水建筑的高度",{"key":24,"text":321,"correct":32},"系统的用水量",{"key":27,"text":323,"correct":32},"水泵启动次数",{"key":30,"text":325,"correct":22},"压水罐工作的上下限压差",{"id":327,"libraryId":5,"type":138,"typeLabel":139,"stem":328,"options":329,"answer":163,"analysis":17},880176,"确定洁净室空气流型和送风量的原则，正确的应是下列哪几项？",[330,332,334,336],{"key":20,"text":331,"correct":22},"空气洁净度等级要求为ISO6～9级的洁净室，应采用单向流",{"key":24,"text":333,"correct":32},"洁净室工作区的气流分布应均匀",{"key":27,"text":335,"correct":32},"正压洁净室的送风量应大于或等于消除热、湿负荷和保持房间压力的送风量",{"key":30,"text":337,"correct":22},"产生有污染的设备应远离回风口布置",{"id":339,"libraryId":5,"type":138,"typeLabel":139,"stem":340,"options":341,"answer":226,"analysis":17},880177,"下列对大气污染物“最高允许排放浓度”的论述，哪几项是错误的？( )",[342,344,346,348],{"key":20,"text":343,"correct":32},"是指温度在293K，大气压力在101325Pa状态下干空气的浓度",{"key":24,"text":345,"correct":32},"是指任何时间都不允许超过的限值",{"key":27,"text":347,"correct":22},"是指较低的排气口如15m高和较高的排气口如60m高都必须遵守的限值",{"key":30,"text":349,"correct":22},"是指城市居民区、农村地区和工矿地区都不允许超过的限值",{"id":351,"libraryId":5,"type":138,"typeLabel":139,"stem":352,"options":353,"answer":201,"analysis":17},880178,"下列( )是通风气流组织的基本原则。",[354,356,358,360],{"key":20,"text":355,"correct":22},"送、排风口分布均匀",{"key":24,"text":357,"correct":32},"排风口尽量靠近有害物源或有害物浓度高的区域",{"key":27,"text":359,"correct":32},"送风口尽量靠近人员工作区",{"key":30,"text":361,"correct":32},"减少涡流，避免有害物积聚",{"id":363,"libraryId":5,"type":138,"typeLabel":139,"stem":364,"options":365,"answer":176,"analysis":17},880179,"关于受限射流，错误的说法是( )。",[366,368,370,372],{"key":20,"text":367,"correct":32},"贴附射流下部流速越大，静压越小",{"key":24,"text":369,"correct":22},"贴附射流可视为完整射流的一半",{"key":27,"text":371,"correct":32},"贴附射流射程较同样喷口的自由射流短",{"key":30,"text":373,"correct":32},"阿基米德数越小，则贴附长度越短",{"id":375,"libraryId":5,"type":138,"typeLabel":139,"stem":376,"options":377,"answer":239,"analysis":17},880180,"对水冷式冷水机组冷凝器的污垢系数的表述，下列哪几项是错误的?( )。",[378,380,382,384],{"key":20,"text":379,"correct":32},"污垢系数是一个无量纲单位",{"key":24,"text":381,"correct":22},"污垢系数加大，增加换热器的热阻",{"key":27,"text":383,"correct":22},"污垢系数加大，水在冷凝器内的流动阻力增大",{"key":30,"text":385,"correct":32},"机组冷凝器进出水温升降低，表明污垢严重程度加大",{"id":387,"libraryId":5,"type":138,"typeLabel":139,"stem":388,"options":389,"answer":226,"analysis":17},880181,"作为专业人员掩蔽所的4个人防地下室，主要出入口最小防毒通道的计算换气次数( )是符合规范要求的。",[390,391,392,393],{"key":20,"text":17,"correct":32},{"key":24,"text":17,"correct":32},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":395,"libraryId":5,"type":138,"typeLabel":139,"stem":396,"options":397,"answer":239,"analysis":17},880182,"在计算由门窗缝隙渗入室内的冷空气的耗热量时，下列哪几项表述是错误的?( )。",[398,400,402,404],{"key":20,"text":399,"correct":32},"在多层民用建筑的冷风渗透量确定，可忽略室外风速沿高度递增的因素，只计算热压及风压联合作用时的渗透冷风量",{"key":24,"text":401,"correct":22},"高层民用建筑的冷风渗透量确定，应考虑热压及风压联合作用，以及室外风速及高度递增的因素",{"key":27,"text":403,"correct":22},"建筑由门窗缝隙渗入室内的冷空气的耗热量，可根据建筑高度，玻璃窗和围护结构总耗热量进行估算",{"key":30,"text":405,"correct":32},"对住宅建筑阳台门而言，除计算由缝隙渗入室内的冷空气的耗热量外，还应计算由外门附加耗热量时将其计入外门总数量内",{"id":407,"libraryId":5,"type":138,"typeLabel":139,"stem":408,"options":409,"answer":277,"analysis":17},880183,"筛板塔的优点为( )。",[410,412,414,416],{"key":20,"text":411,"correct":32},"结构简单",{"key":24,"text":413,"correct":32},"阻力适中",{"key":27,"text":415,"correct":32},"处理气体量大",{"key":30,"text":417,"correct":22},"操作稳定",{"id":419,"libraryId":5,"type":138,"typeLabel":139,"stem":420,"options":421,"answer":277,"analysis":17},880184,"关于空调冷热源能源的选择原则，错误的表述是( )。",[422,424,426,428],{"key":20,"text":423,"correct":32},"由于电力空调方便、清洁、高效、可靠，因此应尽可能采用电力空调",{"key":24,"text":425,"correct":32},"采用燃气空调可以大幅度减少电耗，因此在电力紧张的地区应大力推广应用",{"key":27,"text":427,"correct":32},"燃煤锅炉污染大，作为空调热源应逐步实现“煤改气”",{"key":30,"text":429,"correct":22},"应考虑当地的具体情况，包括建筑物规模、建筑规划情况等因素，通过综合技术经济性比较来确定",{"id":431,"libraryId":5,"type":138,"typeLabel":139,"stem":432,"options":433,"answer":442,"analysis":17},880185,"下列夏季空调湿负荷计算项目中，应考虑( )。",[434,436,438,440],{"key":20,"text":435,"correct":32},"空调餐厅火锅的散湿量",{"key":24,"text":437,"correct":32},"窗户渗透空气带入的湿量",{"key":27,"text":439,"correct":22},"厨房做饭产生的湿量",{"key":30,"text":441,"correct":32},"人员呼吸产生的湿量","ABD",{"id":444,"libraryId":5,"type":138,"typeLabel":139,"stem":445,"options":446,"answer":239,"analysis":17},880186,"分户热计量热水供暖系统采用水平单管跨越式时，散热器上一般应安装( )。",[447,449,451,453],{"key":20,"text":448,"correct":32},"排空气装置",{"key":24,"text":450,"correct":22},"热分配表",{"key":27,"text":452,"correct":22},"热量表",{"key":30,"text":454,"correct":32},"温度调节装置",{"id":456,"libraryId":5,"type":138,"typeLabel":139,"stem":457,"options":458,"answer":277,"analysis":17},880187,"设计高层民用建筑防烟楼梯间及其前室的加压送风系统时，下述正压值的搭配合理的是( )。",[459,461,463,465],{"key":20,"text":460,"correct":32},"防烟楼梯间取50Pa，前室取25Pa",{"key":24,"text":462,"correct":32},"防烟楼梯间取40Pa，前室取30Pa",{"key":27,"text":464,"correct":32},"防烟楼梯间取45Pa，前室取27.5Pa",{"key":30,"text":466,"correct":22},"防烟楼梯间取50Pa，前室取30Pa",{"id":468,"libraryId":5,"type":138,"typeLabel":139,"stem":469,"options":470,"answer":176,"analysis":17},880188,"以下排水管道的连接方式，哪些是错误的?( )。",[471,473,475,477],{"key":20,"text":472,"correct":32},"空调器的冷凝水，可以就近接入建筑物的雨水管道中",{"key":24,"text":474,"correct":22},"居住小区应采用生活排水和雨水分流排水系统",{"key":27,"text":476,"correct":32},"医院的所有污水应单独排出进行消毒处理",{"key":30,"text":478,"correct":32},"住宅厨房和卫生间的排水管道应分别独立设置",{"id":480,"libraryId":5,"type":138,"typeLabel":139,"stem":481,"options":482,"answer":264,"analysis":17},880189,"洁净室的排风系统应采取的措施是( )。",[483,485,487,489],{"key":20,"text":484,"correct":32},"防止室外气流倒灌",{"key":24,"text":486,"correct":32},"含有易燃易爆物质的局部排风系统的防火防爆",{"key":27,"text":488,"correct":32},"排风介质中的有害物浓度及排放量超出有关排放标准，应进行无害处理",{"key":30,"text":490,"correct":32},"对于排除热湿废气应考虑排风管内冷凝水的排除",{"id":492,"libraryId":5,"type":138,"typeLabel":139,"stem":493,"options":494,"answer":442,"analysis":17},880190,"下列哪些因素与住宅室内燃气管道的计算流量有关？( )",[495,497,499,501],{"key":20,"text":496,"correct":32},"燃具同时工作系数",{"key":24,"text":498,"correct":32},"同一类型燃具的数目",{"key":27,"text":500,"correct":22},"燃气的低热值",{"key":30,"text":502,"correct":32},"燃具的额定流量",{"id":504,"libraryId":5,"type":138,"typeLabel":139,"stem":505,"options":506,"answer":277,"analysis":17},880191,"关于制冷剂下列说法正确的是( )。",[507,509,511,513],{"key":20,"text":508,"correct":32},"氨是典型的难溶于润滑油的制冷剂，因此氨制冷系统中的管道换热器的传热表面上会积有油膜，影响传热效果",{"key":24,"text":510,"correct":32},"氟利昂是一类透明、无味、基本无毒又不易燃烧、爆炸、化学性能稳定的制冷剂",{"key":27,"text":512,"correct":32},"氟利昂13临界温度较低，常温下压力很高，适用于复叠式制冷系统，作为低温级的制冷剂",{"key":30,"text":514,"correct":22},"R22的排气温度比R502低10～25℃",{"id":516,"libraryId":5,"type":138,"typeLabel":139,"stem":517,"options":518,"answer":527,"analysis":17},880192,"关于空调系统设置补水泵的做法，哪几项是正确的？",[519,521,523,525],{"key":20,"text":520,"correct":22},"小时流量为系统循环水量的5%～10%",{"key":24,"text":522,"correct":32},"小时流量为系统水容量的5%～10%",{"key":27,"text":524,"correct":22},"补水泵扬程，应保证补水压力比补水点压力高30～50kPa",{"key":30,"text":526,"correct":32},"补水泵扬程，应保证补水压力比系统静止时补水点压力高30～50kPa","BD",{"id":529,"libraryId":5,"type":138,"typeLabel":139,"stem":530,"options":531,"answer":176,"analysis":17},880193,"工业厂房内排除温度超过80℃空气的管道与可燃物体间的间距小于150mm时，如采用不燃材料隔热其厚度的规定( )是错误的。",[532,534,536,538],{"key":20,"text":533,"correct":32},"不小于40mm",{"key":24,"text":535,"correct":22},"不小于50mm",{"key":27,"text":537,"correct":32},"不小于55mm",{"key":30,"text":539,"correct":32},"不小于60mm",{"id":541,"libraryId":5,"type":138,"typeLabel":139,"stem":542,"options":543,"answer":442,"analysis":17},880194,"机械循环热水供暖系统膨胀水箱配管的做法，正确的是( )。",[544,546,548,550],{"key":20,"text":545,"correct":32},"膨胀管宜接至循环水泵入口处",{"key":24,"text":547,"correct":32},"溢水管接到下水道，该管不应装阀门",{"key":27,"text":549,"correct":22},"膨胀管应安装阀门",{"key":30,"text":551,"correct":32},"循环管上不得安装阀门",{"id":553,"libraryId":5,"type":138,"typeLabel":139,"stem":554,"options":555,"answer":264,"analysis":17},880195,"进行分户系统水力计算时应注意( )。",[556,558,560,562],{"key":20,"text":557,"correct":32},"室内所用的塑料管的水力计算表可参考《建筑给水排水设计手册》中热水管水力计算表",{"key":24,"text":559,"correct":32},"按户分环的下分下回式双管系统，共用立管的沿程平均比摩阻宜采用30～60Pa／m",{"key":27,"text":561,"correct":32},"最不利环路的总压力损失包括系统内的压力损失和供暖入口至该用户入口间的压力损失，还要考虑10%的富余值",{"key":30,"text":563,"correct":32},"不同系统形式的最不利环路不同",{"id":565,"libraryId":5,"type":138,"typeLabel":139,"stem":566,"options":567,"answer":442,"analysis":17},880196,"确定层高大于4m的工业建筑的冬季室内设计温度时( )。",[568,570,572,574],{"key":20,"text":569,"correct":32},"地面应采用工作地点的温度",{"key":24,"text":571,"correct":32},"墙应采用室内平均温度",{"key":27,"text":573,"correct":22},"门应采用工作地点的温度",{"key":30,"text":575,"correct":32},"屋顶应采用屋顶下的温度",{"id":577,"libraryId":5,"type":138,"typeLabel":139,"stem":578,"options":579,"answer":150,"analysis":17},880197,"下列关于工业建筑物内有害物质产生与控制的说法，正确的是哪几项?( )。",[580,582,584,586],{"key":20,"text":581,"correct":22},"有害物质产生由生产工艺决定，生产工艺可以通过实行清洁生产方式，以根本解决污染物问题",{"key":24,"text":583,"correct":22},"粉尘依靠自身的能量可以长期悬浮在车间的空气中",{"key":27,"text":585,"correct":32},"控制污染物扩散最有效的措施就是控制气流组织",{"key":30,"text":587,"correct":32},"排风系统抽吸的污染物越多，排风量越大，废气处理的代价就越大",{"id":589,"libraryId":5,"type":138,"typeLabel":139,"stem":590,"options":591,"answer":264,"analysis":17},880198,"吸附设备应满足的基本要求是( )。",[592,594,596,598],{"key":20,"text":593,"correct":32},"在吸附器内，气体与吸附剂应有足够长的接触时间",{"key":24,"text":595,"correct":32},"吸附设备内应容纳一定数量的吸附剂，以保证必需的使用期",{"key":27,"text":597,"correct":32},"应便于更换吸附剂或使其再生",{"key":30,"text":599,"correct":32},"当气流中混有较高浓度的粉尘时，应在吸附器之前装设过滤器",{"id":601,"libraryId":5,"type":138,"typeLabel":139,"stem":602,"options":603,"answer":176,"analysis":17},880199,"在排除有爆炸危险粉尘的通风系统中，下列措施正确的是( )。",[604,606,608,610],{"key":20,"text":605,"correct":32},"净化粉尘用的干式除尘器和过滤器应布置在系统的负压段",{"key":24,"text":607,"correct":22},"只需对除尘器设置泄爆装置",{"key":27,"text":609,"correct":32},"应采用防爆风机",{"key":30,"text":611,"correct":32},"当防爆风机不能满足技术要求时可采用诱导通风装置",{"id":613,"libraryId":5,"type":138,"typeLabel":139,"stem":614,"options":615,"answer":226,"analysis":17},880200,"空调系统采用加湿器加湿过程的表述，下列哪几项是正确的？( )",[616,618,620,622],{"key":20,"text":617,"correct":32},"湿膜加湿器加湿为等焓过程",{"key":24,"text":619,"correct":32},"低压干蒸汽加湿器加湿为等温过程",{"key":27,"text":621,"correct":22},"高位喷雾加湿器加湿为等温过程",{"key":30,"text":623,"correct":22},"电极式加湿器加湿为等焓过程",[625,628,631,634,637,640],{"id":15,"name":626,"category":7,"favorite":627},"领导干部任职前廉政法规知识测试题",92,{"id":629,"name":630,"category":7,"favorite":15},595,"建筑结构与设备",{"id":632,"name":633,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":635,"name":636,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":638,"name":639,"category":7,"favorite":8},534,"BIM工程师",{"id":641,"name":639,"category":7,"favorite":8},535]