[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,6,50,2054,[13,34,46,58,70,81,93,105,116,128,140,152,160,172,184,196,208,220,232,244,256,268,280,287,299,311,323,335,346,358,370,382,394,406,418,430,442,454,465,477,489,501,513,525,537,549,561,573,585,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},880101,1,"单选题","利用机械减压方式排烟时，( )送排风方式产生较好效果。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","上送下排",false,{"key":24,"text":25,"correct":26},"B","下送上排",true,{"key":28,"text":29,"correct":22},"C","下送下排",{"key":31,"text":32,"correct":22},"D","上送上排","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},880102,"蓄冰空调系统的特点，下列哪一项说法是正确的？( )",[38,40,42,44],{"key":20,"text":39,"correct":26},"可以对电力削峰填谷和减少运行费",{"key":24,"text":41,"correct":22},"可以对电力削峰填谷和减少初投资",{"key":28,"text":43,"correct":22},"可以对电力削峰填谷和节能",{"key":31,"text":45,"correct":22},"可以对电力削峰填谷、节能和减少运行费",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},880103,"住宅集中热水供应系统配水点的热水温度不应低于( )。",[50,52,54,56],{"key":20,"text":51,"correct":22},"40℃",{"key":24,"text":53,"correct":26},"45℃",{"key":28,"text":55,"correct":22},"50℃",{"key":31,"text":57,"correct":22},"55℃",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},880104,"调压装置设置在地上单独的调压箱(悬挂式)内时，对居民和商业用户燃气进口压力不应大于( )MPa。",[62,64,66,68],{"key":20,"text":63,"correct":22},"0.8",{"key":24,"text":65,"correct":26},"0.4",{"key":28,"text":67,"correct":22},"0.2",{"key":31,"text":69,"correct":22},"0.1",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":72,"answer":28,"analysis":33},880105,[73,75,77,79],{"key":20,"text":74,"correct":22},"流量平衡管",{"key":24,"text":76,"correct":22},"压力平衡管",{"key":28,"text":78,"correct":26},"排空气管",{"key":31,"text":80,"correct":22},"大气连通管",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":31,"analysis":33},880106,"有关生活排水管道设置检查口和清扫口的做法，符合规范的应是( )。",[85,87,89,91],{"key":20,"text":86,"correct":22},"某居室的卫生间设有坐便器、洗脸盆和淋浴器，塑料排水横管上设置清扫口",{"key":24,"text":88,"correct":22},"某居室的卫生间设有坐便器、洗脸盆和淋浴器，铸铁排水横管上不设置清扫口",{"key":28,"text":90,"correct":22},"某普通住宅铸铁排水立管每5层设置一个检查口",{"key":31,"text":92,"correct":26},"某住宅DN75的排水立管底部至室外检查井中心的长度为15m，在排出管上设清扫口",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":31,"analysis":33},880107,"某办公建筑所对应的参考建筑空调能耗为35kW·h\u002F(㎡·a)，供暖能耗为20kW·h\u002F(㎡· A)，照明能耗为25kW·h\u002F(㎡·a)，建筑供暖空调及照明能耗总量应保证为多少才能满足《绿建标准》节能部分的优选项第5.2.16条的要求？( )",[97,99,101,103],{"key":20,"text":98,"correct":22},"80kW·h\u002F(㎡·a)",{"key":24,"text":100,"correct":22},"75kW·h\u002F(㎡·a)",{"key":28,"text":102,"correct":22},"65kW·h\u002F(㎡·a)",{"key":31,"text":104,"correct":26},"60kW·h\u002F(㎡·a)",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":107,"answer":28,"analysis":33},880108,[108,110,112,114],{"key":20,"text":109,"correct":22},"质量浓度",{"key":24,"text":111,"correct":22},"计数浓度",{"key":28,"text":113,"correct":26},"粒径颗粒浓度",{"key":31,"text":115,"correct":22},"粒径分布",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":28,"analysis":33},880109,"进行围护结构防潮验算时，冷凝界面温度与下列哪一项有关？( )",[120,122,124,126],{"key":20,"text":121,"correct":22},"供暖室外计算温度",{"key":24,"text":123,"correct":22},"历年室外最低温度",{"key":28,"text":125,"correct":26},"供暖期室外平均温度",{"key":31,"text":127,"correct":22},"累年室外最低日平均温度",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":20,"analysis":33},880110,"根据规范规定，推荐的地源热泵系统地埋管换热器管道内水流速，应是下列哪一项？",[132,134,136,138],{"key":20,"text":133,"correct":26},"双U形埋管不小于0.4m\u002Fs，单U形埋管不小于0.6m\u002Fs",{"key":24,"text":135,"correct":22},"双U形埋管不小于0.6m\u002Fs，单U形埋管不小于0.4m\u002Fs",{"key":28,"text":137,"correct":22},"双U形埋管不小于0.6m\u002Fs，单U形埋管不小于0.8m\u002Fs",{"key":31,"text":139,"correct":22},"双U形埋管不小于0.8m\u002Fs，单U形埋管不小于0.6m\u002Fs",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":24,"analysis":33},880111,"一台高效离心式除尘器，经冷态试验，下列哪一项结果为合格？",[144,146,148,150],{"key":20,"text":145,"correct":22},"除尘器压力损失为1000Pa时，漏风率2%",{"key":24,"text":147,"correct":26},"除尘器压力损失为1600Pa时，漏风率2%",{"key":28,"text":149,"correct":22},"除尘器压力损失为1600Pa时，漏风率3%",{"key":31,"text":151,"correct":22},"除尘器压力损失为1000Pa时，漏风率3%",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":24,"analysis":33},880112,"空调一次泵冷水系统(水泵定转速运行)的压差控制旁通电动阀的四种连接方式如下所示，哪种连接方式是错误的？",[156,157,158,159],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":28,"analysis":33},880113,"对于室内空气有洁净要求的房间，为保持室内正压，下列选项正确的是( )。",[164,166,168,170],{"key":20,"text":165,"correct":22},"自然进风量与机械进风量之和等于排风量与机械排风量之和",{"key":24,"text":167,"correct":22},"机械进风量大于机械排风量",{"key":28,"text":169,"correct":26},"机械进风量大于机械排风量与自然排风量之和",{"key":31,"text":171,"correct":22},"自然进风量与机械进风量之和小于自然排风量与机械排风量之和",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":31,"analysis":33},880114,"某单位有自备水井，水质符合国家标准《生活饮用水卫生标准》，但水量不能满足用水高峰时的使用要求，需要由城市给水管道补充，以下哪一种连接方式是正确的？( )",[176,178,180,182],{"key":20,"text":177,"correct":22},"两种管道连接处，在城市给水管道上设置倒流防止器",{"key":24,"text":179,"correct":22},"两种管道连接处，均设置倒流防止器",{"key":28,"text":181,"correct":22},"如果自备水源的水质符合《生活饮用水卫生标准》，可以直接连接，但应设置止回阀",{"key":31,"text":183,"correct":26},"将城市给水管道的水放入自备水源的贮水池内，经自备水源系统加压后为同一用水系统供水",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":28,"analysis":33},880115,"生活饮用水管道的配水件出水口高出承接用水容器溢流边缘的最小空气间隙，应( )。",[188,190,192,194],{"key":20,"text":189,"correct":22},"满足出水口不得被任何液体或杂质淹没的要求",{"key":24,"text":191,"correct":22},"等于出水口直径的2.5倍",{"key":28,"text":193,"correct":26},"大于等于出水口直径的2.5倍",{"key":31,"text":195,"correct":22},"小于等于出水口直径的2.5倍",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":28,"analysis":33},880116,"对于舒适性空调，在进出口空气状态和风量相同的情况下，大气压力降低，表冷器的供冷量如何变化？( )",[200,202,204,206],{"key":20,"text":201,"correct":22},"增加",{"key":24,"text":203,"correct":22},"不变",{"key":28,"text":205,"correct":26},"减小",{"key":31,"text":207,"correct":22},"不确定",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":28,"analysis":33},880117,"建筑高度为48m的办公楼，地上15层，地下3层，防烟楼梯间在地上部分每层各有可开启外窗面积1.5㎡，前室无窗。应怎样进行防排烟设计？( )",[212,214,216,218],{"key":20,"text":213,"correct":22},"可以通过防烟楼梯间自然排烟，前室不需排烟",{"key":24,"text":215,"correct":22},"防烟楼梯间自然排烟，前室加压送风",{"key":28,"text":217,"correct":26},"防烟楼梯间的地上部分自然排烟，前室和防烟楼梯间的地下部分分别加压送风",{"key":31,"text":219,"correct":22},"防烟楼梯间和前室分别加压送风",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":28,"analysis":33},880118,"某住宅小区中的一栋三层会馆采用重力循环热水供暖系统，每层的散热器均并联在供回水立管间，热水直接被分配到各层散热器，冷却后的水由回水支、立管及干管回流至锅炉。该系统形式属于下列哪一项？",[224,226,228,230],{"key":20,"text":225,"correct":22},"单项下供上回跨越式系统",{"key":24,"text":227,"correct":22},"单管上供下回系统",{"key":28,"text":229,"correct":26},"双管上供下回系统",{"key":31,"text":231,"correct":22},"水平跨越式系统",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":28,"analysis":33},880119,"具有多种使用功能的综合性建筑，当其热水由同一热水供应系统供应时，其生活热水设计小时耗热量可按( )计算。",[236,238,240,242],{"key":20,"text":237,"correct":22},"各用水部门的设计小时耗热量之和",{"key":24,"text":239,"correct":22},"各用水部门的平均小时耗热量之和",{"key":28,"text":241,"correct":26},"同一时间内出现用水高峰的主要用水部门的设计小时耗热量与其他用水部门的平均小时耗热量之和",{"key":31,"text":243,"correct":22},"同一时间内出现用水高峰的主要用水部门的平均小时耗热量与其他用水部门的设计小时耗热量之和",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":28,"analysis":33},880120,"关于空调系统清洁的说法中不正确的是( )。",[248,250,252,254],{"key":20,"text":249,"correct":22},"对空调系统进行清洁有利于系统节能",{"key":24,"text":251,"correct":22},"对空调系统进行清洁有利于人体健康",{"key":28,"text":253,"correct":26},"空调系统的送风应设置化学消毒段，以避免疾病传播",{"key":31,"text":255,"correct":22},"对空调系统清洁不当有可能造成二次污染",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":31,"analysis":33},880121,"一个正在运行的水冷螺杆式冷水机组制冷系统，发现系统制冷出力不足，达不到设计要求。经观察冷水机组蒸发压力正常，冷凝压力过高。下列哪一项不会造成制冷出力不足？",[260,262,264,266],{"key":20,"text":261,"correct":22},"冷却水量不足或冷却塔风机转速下降",{"key":24,"text":263,"correct":22},"换热系统换热管表面污垢增多",{"key":28,"text":265,"correct":22},"冷却水进口水温过高",{"key":31,"text":267,"correct":26},"冷却水水泵未采用变频调速",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":28,"analysis":33},880122,"热水热力网供水管道上任何一点的压力不应低于供热介质的汽化压力，并应留压力( )kPa。",[272,274,276,278],{"key":20,"text":273,"correct":22},"10～20",{"key":24,"text":275,"correct":22},"20～40",{"key":28,"text":277,"correct":26},"30～50",{"key":31,"text":279,"correct":22},"40～60",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":282,"answer":28,"analysis":33},880123,[283,284,285,286],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":28,"analysis":33},880124,"风管的直管三通，关于局部阻力系数说法正确的是( )。",[291,293,295,297],{"key":20,"text":292,"correct":22},"直管和支管的局部阻力系数一定都为正值",{"key":24,"text":294,"correct":22},"直管和支管的局部阻力系数一定为一负一正",{"key":28,"text":296,"correct":26},"直管和支管中，其中一管的局部阻力系数出现负值，另一管的局部阻力系数一定为正值",{"key":31,"text":298,"correct":22},"直管和支管中，其中一管的局部阻力系数出现负值，另一管阻力系数可能是负值也可能是正值",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":20,"analysis":33},880125,"水平单管跨越式系统散热器组数不宜超过几组？( )",[303,305,307,309],{"key":20,"text":304,"correct":26},"6组",{"key":24,"text":306,"correct":22},"8组",{"key":28,"text":308,"correct":22},"10组",{"key":31,"text":310,"correct":22},"12组",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":28,"analysis":33},880126,"进行燃气辐射供暖系统设计计算时，舒适温度一般取( )。",[315,317,319,321],{"key":20,"text":316,"correct":22},"10～16℃",{"key":24,"text":318,"correct":22},"12～18℃",{"key":28,"text":320,"correct":26},"15～20℃",{"key":31,"text":322,"correct":22},"18～22℃",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":24,"analysis":33},880127,"通风工程所要控制的空气中有害物质主要为( )。",[327,329,331,333],{"key":20,"text":328,"correct":22},"有害气体、有害粉尘、余热、余湿",{"key":24,"text":330,"correct":26},"有害气体、粉尘、余热、余湿",{"key":28,"text":332,"correct":22},"有害气体、粉尘、高热、高湿",{"key":31,"text":334,"correct":22},"气体、粉尘、余热、余湿",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":24,"analysis":33},880128,"气体溶解度小，吸收速度主要受( )阻力控制。",[339,341,343,345],{"key":20,"text":340,"correct":22},"气相一侧",{"key":24,"text":342,"correct":26},"液相一侧",{"key":28,"text":344,"correct":22},"两相同等",{"key":31,"text":207,"correct":22},{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":33},880129,"高层民用建筑设置排烟设施的走道，净高不超过6.00m的房间应采用挡烟垂壁、隔墙或从顶棚下突出不小于( )的梁划分防烟分区是允许的。",[350,352,354,356],{"key":20,"text":351,"correct":22},"0.40m",{"key":24,"text":353,"correct":26},"0.50m",{"key":28,"text":355,"correct":22},"0.60m",{"key":31,"text":357,"correct":22},"0.80m",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},880130,"针对公共建筑空调系统室内运行参数，有的城市主管部门明确规定夏季的室内温度一律不允许低于26℃，其根本原因应是下列哪一项？",[362,364,366,368],{"key":20,"text":363,"correct":22},"为了保证达到健康空调效果",{"key":24,"text":365,"correct":26},"为了培养人们的节能意识",{"key":28,"text":367,"correct":22},"为了度过电能紧缺的时期",{"key":31,"text":369,"correct":22},"为了修改空调设计规范打下基础造成现状的原因分析",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":24,"analysis":33},880131,"吸收式制冷装置主要靠消耗( )来达到制冷目的。",[374,376,378,380],{"key":20,"text":375,"correct":22},"机械功",{"key":24,"text":377,"correct":26},"热能",{"key":28,"text":379,"correct":22},"冷量",{"key":31,"text":381,"correct":22},"电能",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":31,"analysis":33},880132,"某热水供暖系统的供暖管道施工说明，下列哪一项是错误的？( )",[386,388,390,392],{"key":20,"text":387,"correct":22},"气、水在水平管道内逆向流动时，管道坡度是5‰",{"key":24,"text":389,"correct":22},"气、水在水平管道内同向流动时，管道坡度是3‰",{"key":28,"text":391,"correct":22},"连接散热器的支管管道坡度是1%",{"key":31,"text":393,"correct":26},"公称管径为80mm的镀锌钢管应采用焊接",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":20,"analysis":33},880133,"在可能情况下，设置局部排风罩时首选( )。",[398,400,402,404],{"key":20,"text":399,"correct":26},"密闭罩",{"key":24,"text":401,"correct":22},"吹吸式排风",{"key":28,"text":403,"correct":22},"外部吸气罩",{"key":31,"text":405,"correct":22},"接受式排风罩",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":33},880134,"风机盘管机组安装前应按下列检查数量的规定，进行承压试验( )。",[410,412,414,416],{"key":20,"text":411,"correct":26},"按总数抽查10%，且不得少于1台",{"key":24,"text":413,"correct":22},"按总数抽查15%，且不得少于1台",{"key":28,"text":415,"correct":22},"按总数抽查20%，且不得少于3台",{"key":31,"text":417,"correct":22},"全部检查",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":31,"analysis":33},880135,"关于水蓄冷空调系统的规定中不正确的是( )。",[422,424,426,428],{"key":20,"text":423,"correct":22},"蓄冷水温不宜低于4℃",{"key":24,"text":425,"correct":22},"当空调水系统最高点高于蓄水池设计水面10m时，应采用间接供冷",{"key":28,"text":427,"correct":22},"蓄冷水池的深度不宜低于2m",{"key":31,"text":429,"correct":26},"蓄冷水池不应与消防水池合用",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},880136,"冰蓄冷系统，蓄冷周期内仍有供冷负荷(基载负荷)，下列哪种情况需要设置基载制冷机？( )",[434,436,438,440],{"key":20,"text":435,"correct":22},"基载负荷小于制冷主机单台空调工况制冷量的20%",{"key":24,"text":437,"correct":26},"基载负荷超过制冷主机单台空调工况制冷量的20%",{"key":28,"text":439,"correct":22},"基载负荷下的空调总冷量不足设计蓄冰冷量的10%",{"key":31,"text":441,"correct":22},"没有具体要求",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":33},880137,"选择通风机时，下列哪项要求是错误的？( )",[446,448,450,452],{"key":20,"text":447,"correct":22},"用以输送非标准状态空气时，应对其电动机的轴功率进行验算",{"key":24,"text":449,"correct":26},"串联或并联工作时，应选用相同型号的通风机",{"key":28,"text":451,"correct":22},"设计工况下通风机实际工作点的效率不应低于其最高效率的90%",{"key":31,"text":453,"correct":22},"系统风量变化大且运行时间长，宜采用变速通风机",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":456,"answer":20,"analysis":33},880138,[457,459,461,463],{"key":20,"text":458,"correct":26},"取消水池",{"key":24,"text":460,"correct":22},"改造水管",{"key":28,"text":462,"correct":22},"将冷却水泵改在屋顶",{"key":31,"text":464,"correct":22},"换冷却塔",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":28,"analysis":33},880139,"微穿孔消声器与普通共振消声器在孔径上的区别是( )。",[469,471,473,475],{"key":20,"text":470,"correct":22},"孔径≤0.3mm",{"key":24,"text":472,"correct":22},"孔径≤0.5mm",{"key":28,"text":474,"correct":26},"孔径≤1.0mm",{"key":31,"text":476,"correct":22},"孔径≤1.2mm",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":31,"analysis":33},880140,"某地的室外设计干球温度为36℃、相对湿度为80%，送风干球温度为15℃，相对湿度为30%的直流式全新风系统，冷水供回水温度为7\u002F12℃。该系统的空气处理过程，下列哪一项是正确的？",[481,483,485,487],{"key":20,"text":482,"correct":22},"新风→一级冷却→二级冷却",{"key":24,"text":484,"correct":22},"新风→一级冷却→一级转轮除湿",{"key":28,"text":486,"correct":22},"新风→一级转轮除湿→一级冷却",{"key":31,"text":488,"correct":26},"新风→一级冷却→一级转轮除湿→二级冷却",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":20,"analysis":33},880141,"新建锅炉房的锅炉台数不宜( )。",[493,495,497,499],{"key":20,"text":494,"correct":26},"超过5台",{"key":24,"text":496,"correct":22},"超过6台",{"key":28,"text":498,"correct":22},"超过7台",{"key":31,"text":500,"correct":22},"低于4台",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":31,"analysis":33},880142,"设有集中供暖和机械排风的工业车间，下列哪项要求是正确的？( )",[505,507,509,511],{"key":20,"text":506,"correct":22},"应采用自然补风",{"key":24,"text":508,"correct":22},"应设置机械送风以保证风量平衡",{"key":28,"text":510,"correct":22},"设置机械送风系统时应考虑风量平衡",{"key":31,"text":512,"correct":26},"设置机械送风系统时应考虑风量、热量平衡",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":28,"analysis":33},880143,"从建筑物通风范围划分，通风方式可分为( )。",[517,519,521,523],{"key":20,"text":518,"correct":22},"自然通风和机械通风",{"key":24,"text":520,"correct":22},"工业通风和民用通风",{"key":28,"text":522,"correct":26},"全面通风和局部通风",{"key":31,"text":524,"correct":22},"净化通风和除尘",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":28,"analysis":33},880144,"水平地埋管换热器的敷设要求是( )。",[529,531,533,535],{"key":20,"text":530,"correct":22},"坡度宜为0.002，埋管顶部应在冻土层以下0.4m，且距地面不宜小于0.8m",{"key":24,"text":532,"correct":22},"可以没有坡度，埋管顶部应在冻土层以下0.5m，且距地面不宜小于1.0m",{"key":28,"text":534,"correct":26},"可以没有坡度，埋管顶部应在冻土层以下0.4m，且距地面不宜小于0.8m",{"key":31,"text":536,"correct":22},"坡度宜为0.002，埋管顶部应在冻土层以下0.5m，且距地面不宜小于1.0m",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":31,"analysis":33},880145,"多层居住建筑地上长度大于( )的疏散走道应设排烟设施。",[541,543,545,547],{"key":20,"text":542,"correct":22},"10m",{"key":24,"text":544,"correct":22},"20m",{"key":28,"text":546,"correct":22},"30m",{"key":31,"text":548,"correct":26},"40m",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":24,"analysis":33},880146,"压缩式冷水机组的冷却水进口温度一般不宜低于下列哪一项？( )",[553,555,557,559],{"key":20,"text":554,"correct":22},"20℃",{"key":24,"text":556,"correct":26},"15.5℃",{"key":28,"text":558,"correct":22},"18℃",{"key":31,"text":560,"correct":22},"18.5℃",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":24,"analysis":33},880147,"下列对公用厨房通风设计的要求错误的是( )。",[565,567,569,571],{"key":20,"text":566,"correct":22},"对发热量大且散发大量油烟和蒸汽的厨房设备应采用局部机械排风",{"key":24,"text":568,"correct":26},"与机械排风对应的补风量不宜小于机械排风量的60%～80%",{"key":28,"text":570,"correct":22},"排油烟风道不应兼作防火排烟风道",{"key":31,"text":572,"correct":22},"厨房区相对其他区域应维持负压",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":33},880148,"散热器安装时，下列哪一项是错误的？( )",[577,579,581,583],{"key":20,"text":578,"correct":26},"散热器安装前应作水压试验，试验压力应为工作压力的1.5倍",{"key":24,"text":580,"correct":22},"15片铸铁片式散热器组对后的平直度允许偏差为4mm",{"key":28,"text":582,"correct":22},"散热器垫片材质当设计无要求时，应采用耐热橡胶",{"key":31,"text":584,"correct":22},"散热器背面与装饰后的墙内表面安装距离，如设计未注明，应为30mm",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":28,"analysis":33},880149,"下列哪一项低温热水地面辐射供暖系统对管材的技术要求是错误的？( )",[589,591,593,595],{"key":20,"text":590,"correct":22},"埋设在填充层内的加热管不应有接头",{"key":24,"text":592,"correct":22},"埋地热水塑料加热管应按使用条件为4级选择",{"key":28,"text":594,"correct":26},"塑料加热管的厚度不得小于1.8mm",{"key":31,"text":596,"correct":22},"铜管的下游管段不宜使用钢管",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":31,"analysis":33},880150,"某23层办公大楼的空调水系统为闭式系统，冷水机组、冷水循环泵和膨胀水箱均置于建筑的最高屋面处，系统调试时，冷水循环泵和供回水管路的振动很大。分析产生问题的原因，是下列哪一项？( )",[601,603,605,607],{"key":20,"text":602,"correct":22},"冷水循环泵的扬程选择过高",{"key":24,"text":604,"correct":22},"冷水循环泵的流量过大",{"key":28,"text":606,"correct":22},"冷水循环泵与膨胀水箱的距离过大",{"key":31,"text":608,"correct":26},"冷水供回水管路中有空气",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]