[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":615},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,5,50,2054,[13,34,46,58,70,82,94,106,118,129,141,153,163,175,187,198,210,222,234,246,256,268,280,291,303,315,327,339,351,363,375,387,399,411,423,435,447,459,471,483,495,507,519,531,543,555,567,579,591,603],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},880051,1,"单选题","体型系数不只是影响围护结构的热损失，它还与建筑造型、平面布局、采光通风等紧密相关。因此，民用建筑体型系数应为( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","条式建筑的体型系数不应超过0.30，点式建筑的体型系数不应超过0.40",false,{"key":24,"text":25,"correct":22},"B","条式建筑的体型系数不应超过0.35，点式建筑的体型系数不应超过0.30",{"key":27,"text":28,"correct":29},"C","条式建筑的体型系数不应超过0.35，点式建筑的体型系数不应超过0.40",true,{"key":31,"text":32,"correct":22},"D","条式建筑的体型系数不应超过0.20，点式建筑的体型系数不应超过0.30","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},880052,"关于地埋管地源热泵系统换热本质的描述，下列哪一项是正确的？",[38,40,42,44],{"key":20,"text":39,"correct":22},"它主要利用的是浅层地热资源",{"key":24,"text":41,"correct":22},"它主要利用的是太阳能给予土壤的热量",{"key":27,"text":43,"correct":29},"它主要利用的是土壤体具有吸热和放热的特性",{"key":31,"text":45,"correct":22},"它主要利用的是地下水与土壤之间的热交换",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},880053,"位于海南岛的某厂房，其室内空调温度要求为(20±2)℃，按照相关设计规范，其外墙的传热系数应不大于( )。",[50,52,54,56],{"key":20,"text":51,"correct":22},"0.8W\u002F(㎡·K)",{"key":24,"text":53,"correct":29},"1.0W\u002F(㎡·K)",{"key":27,"text":55,"correct":22},"1.2W\u002F(㎡·K)",{"key":31,"text":57,"correct":22},"1.5W\u002F(㎡·K)",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},880054,"配制盐水载冷剂的原则是，应使其质量浓度( )合晶点质量浓度。",[62,64,66,68],{"key":20,"text":63,"correct":22},"大于",{"key":24,"text":65,"correct":22},"等于",{"key":27,"text":67,"correct":29},"小于等于",{"key":31,"text":69,"correct":22},"大于等于",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},880055,"建筑高度超过50m的一类公共建筑和建筑高度超过100m的居住建筑，靠外墙的防烟楼梯间及其前室、消防电梯前室或合用前室，下列规定哪个是正确的？( )",[74,76,78,80],{"key":20,"text":75,"correct":22},"宜采用自然排烟方式",{"key":24,"text":77,"correct":29},"不宜采用自然排烟方式",{"key":27,"text":79,"correct":22},"应采用自然排烟方式",{"key":31,"text":81,"correct":22},"不宜采用机械排烟方式",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},880056,"空调室内气流组织设计选项中，不合理的是( )。",[86,88,90,92],{"key":20,"text":87,"correct":22},"采用深井水作为空调冷源时，采用下送上回的送风方式",{"key":24,"text":89,"correct":22},"操作人员较少的大车间，采用个体送风方式",{"key":27,"text":91,"correct":22},"影剧院采用座椅下送风方式",{"key":31,"text":93,"correct":29},"室温允许波动范围为±1℃时，送风温差取4℃",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},880057,"关于低温地面辐射供暖集中供热小区的热媒，下列哪个说法是正确的？( )",[98,100,102,104],{"key":20,"text":99,"correct":22},"换热站应直接提供温度低于60℃的热媒",{"key":24,"text":101,"correct":22},"供暖用户不宜设置混水泵",{"key":27,"text":103,"correct":22},"尽量降低室外热网的供水温度",{"key":31,"text":105,"correct":29},"尽量加大供回水温差",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},880058,"下面选项中不是供热管道保温的主要目的的是( )。",[110,112,114,116],{"key":20,"text":111,"correct":22},"减少热媒输送过程中的能量损失",{"key":24,"text":113,"correct":29},"保护供热管道防腐蚀",{"key":27,"text":115,"correct":22},"保证各用热用户的热媒参数",{"key":31,"text":117,"correct":22},"保证操作人员安全，防止热力管道烫伤人",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},880059,"成都某集体宿舍在进行建筑围护结构热工性能的综合判断时，供暖空调年耗电量计算参数的取值，正确的是下列哪一项？( )",[122,124,125,127],{"key":20,"text":123,"correct":29},"室内计算温度冬季18℃，夏季26℃",{"key":24,"text":33,"correct":22},{"key":27,"text":126,"correct":22},"室外气象参数应采用当年参数",{"key":31,"text":128,"correct":22},"室内得热平均强度为3.8W\u002F㎡",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":27,"analysis":33},880060,"下列哪一项对排水系统结合通气管的定义是正确的？( )",[133,135,137,139],{"key":20,"text":134,"correct":22},"连接数根通气立管的通气管段",{"key":24,"text":136,"correct":22},"为使排水横支管内空气流通而设置的通气立管",{"key":27,"text":138,"correct":29},"排水立管与通气立管的连接管段",{"key":31,"text":140,"correct":22},"为使排水立管内空气流通而设置的垂直通气管道",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":33},880061,"循环水泵的耗电输热比的含义为( )",[145,147,149,151],{"key":20,"text":146,"correct":22},"设计热负荷与循环水泵总功耗的比值",{"key":24,"text":148,"correct":29},"循环水泵总功耗与设计热负荷的比值",{"key":27,"text":150,"correct":22},"循环水泵的铭牌功率与设计热负荷的比值",{"key":31,"text":152,"correct":22},"设计热负荷与循环水泵铭牌功率的比值",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":27,"analysis":33},880062,"燃油锅炉房内日用油箱的容积是( )。",[157,159,160,161],{"key":20,"text":158,"correct":22},"一昼夜的最大用油量",{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":29},{"key":31,"text":162,"correct":22},"按照不同燃油的危险的火灾危险性类别分别确定",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":27,"analysis":33},880063,"热水地面辐射供暖系统供水温度宜采用下列哪个值？( )",[167,169,171,173],{"key":20,"text":168,"correct":22},"25～35℃",{"key":24,"text":170,"correct":22},"30～40℃",{"key":27,"text":172,"correct":29},"35～45℃",{"key":31,"text":174,"correct":22},"40～60℃",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":27,"analysis":33},880064,"带节能器的多级压缩制冷循环可减少能耗，提高制冷系数，下列哪一种制冷压缩机可实现该种制冷循环？( )",[179,181,183,185],{"key":20,"text":180,"correct":22},"活塞式制冷压缩机",{"key":24,"text":182,"correct":22},"螺杆式制冷压缩机",{"key":27,"text":184,"correct":29},"离心式制冷压缩机",{"key":31,"text":186,"correct":22},"涡旋式制冷压缩机",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":189,"answer":24,"analysis":33},880065,[190,192,194,196],{"key":20,"text":191,"correct":22},"粉尘粒径分布中，累计质量占全部粒径范围总质量50%所对应的粒径",{"key":24,"text":193,"correct":29},"分级效率为50%所对应的粒径",{"key":27,"text":195,"correct":22},"粉尘粒径分布中，累计粒子个数占全部粒径范围粒子总个数50%所对应的粒径",{"key":31,"text":197,"correct":22},"某小的粒径区间的代表粒径，该小区间恰好处在将全部粒径范围的粉尘分为质量相等两部分的分界处",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},880066,"一两级除尘器，第一级效率为70%，第二级效率为80%，则总的除尘效率为( )。",[202,204,206,208],{"key":20,"text":203,"correct":29},"94%",{"key":24,"text":205,"correct":22},"90%",{"key":27,"text":207,"correct":22},"87%",{"key":31,"text":209,"correct":22},"95%",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},880067,"计算冷库库房夏季围护结构的热流量时，室外空气计算温度应是下列哪一项？( )",[214,216,218,220],{"key":20,"text":215,"correct":22},"夏季空气调节室外计算逐时综合温度",{"key":24,"text":217,"correct":29},"夏季空气调节室外计算日平均温度",{"key":27,"text":219,"correct":22},"夏季空气调节室外计算日平均综合温度",{"key":31,"text":221,"correct":22},"夏季空气调节室外计算干球温度",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":33},880068,"当室内冷负荷变化时，最简单又易达到效果的方法是( )。",[226,228,230,232],{"key":20,"text":227,"correct":29},"调节再热量",{"key":24,"text":229,"correct":22},"调节新风量",{"key":27,"text":231,"correct":22},"调节露点温度",{"key":31,"text":233,"correct":22},"调节送风量和新风量",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":20,"analysis":33},880069,"两效吸收式制冷循环中，设置有高压和低压两个发生器。工作蒸汽一般在( )。",[238,240,242,244],{"key":20,"text":239,"correct":29},"0.25～0.8MPa",{"key":24,"text":241,"correct":22},"0.25～0.5MPa",{"key":27,"text":243,"correct":22},"2～0.8MPa",{"key":31,"text":245,"correct":22},"25～0.6MPa",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":27,"analysis":33},880070,"工业建筑内人员最小新风量的规定，哪个是正确的？( )",[250,252,254,255],{"key":20,"text":251,"correct":22},"根据不同性质生产厂房的相关规范要求确定",{"key":24,"text":253,"correct":22},"按国家有关现行卫生标准确定",{"key":27,"text":33,"correct":29},{"key":31,"text":33,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":31,"analysis":33},880071,"《公建节能》中规定了空调热水系统的输送能效比限值，所规定的两管制热水管道数值不适用的热水系统，应是下列哪一项？( )",[260,262,264,266],{"key":20,"text":261,"correct":22},"空气源热泵热水系统",{"key":24,"text":263,"correct":22},"水源热泵热水系统",{"key":27,"text":265,"correct":22},"燃气锅炉热水系统",{"key":31,"text":267,"correct":29},"燃气直燃机热水系统",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":24,"analysis":33},880072,"关于建筑室内消火栓的用水量选取说法，正确的应是下列何项？",[272,274,276,278],{"key":20,"text":273,"correct":22},"高度超过24m的仓库消火栓的用水量数值取决于建筑体积大小",{"key":24,"text":275,"correct":29},"高度2lm的科研楼消火栓的用水量数值与建筑体积有关",{"key":27,"text":277,"correct":22},"4层经济型旅馆消火栓的用水量数值取决于建筑的高度",{"key":31,"text":279,"correct":22},"6层住宅消火栓的用水量数值取决于建筑体积大小",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":282,"answer":24,"analysis":33},880073,[283,285,287,289],{"key":20,"text":284,"correct":22},"被遮挡的太阳辐射热，与透过3mm厚透明玻璃的太阳辐射得热之比值",{"key":24,"text":286,"correct":29},"实际透过窗玻璃的太阳辐射得热，与透过3mm厚透明玻璃的太阳辐射得热之比值",{"key":27,"text":288,"correct":22},"被遮挡的太阳辐射热，与透过该面积的太阳辐射热之比值",{"key":31,"text":290,"correct":22},"实际透过窗玻璃的太阳辐射得热，与透过该面积的太阳辐射热之比值",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":24,"analysis":33},880074,"下列关于通风房间热平衡的描述中哪项是错误的？( )",[295,297,299,301],{"key":20,"text":296,"correct":22},"热平衡是通风稳定后房间的总得热量和总失热量相等",{"key":24,"text":298,"correct":29},"若设计计算的总得热量大于总失热量，运行后房间温度就会不断升高",{"key":27,"text":300,"correct":22},"通常只对有温度控制要求的房间进行热平衡计算",{"key":31,"text":302,"correct":22},"对于冬季补充局部排风，室外空气计算温度采用冬季供暖室外计算温度",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":24,"analysis":33},880075,"一台采用地下水的地源热泵，冷热水机组额定(名义)制冷、制热量为150kW。根据国家标准该机组的技术参数，下列哪一项是正确的？( )",[307,309,311,313],{"key":20,"text":308,"correct":22},"制冷时的能效比≥4.3",{"key":24,"text":310,"correct":29},"制热时性能系数≥3.5",{"key":27,"text":312,"correct":22},"名义制冷量是热源侧的进水\u002F出水温度为30℃\u002F35℃时测得",{"key":31,"text":314,"correct":22},"该机组在制冷、制热正常工作时，地下水的水温不应低于15.5℃",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":27,"analysis":33},880076,"在LiBr吸收式冷水机组中，下列哪一项不是发生器的工作内容？( )",[319,321,323,325],{"key":20,"text":320,"correct":22},"加热稀溶液，使其沸腾",{"key":24,"text":322,"correct":22},"产生高压制冷剂蒸气",{"key":27,"text":324,"correct":29},"提纯制冷剂",{"key":31,"text":326,"correct":22},"使稀溶液浓缩，流回吸收器",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":24,"analysis":33},880077,"外部吸气罩在控制点上造成控制风速的大小与( )无关。",[331,333,335,337],{"key":20,"text":332,"correct":22},"外部吸气罩的形式",{"key":24,"text":334,"correct":29},"有害物的毒性",{"key":27,"text":336,"correct":22},"外部吸气罩的排风量",{"key":31,"text":338,"correct":22},"外部吸气罩口与控制点的距离",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":31,"analysis":33},880078,"判断是否采用空气源热泵冷热水机组的主要依据是？( )",[343,345,347,349],{"key":20,"text":344,"correct":22},"冬夏季室外温度和所需冷热量大小",{"key":24,"text":346,"correct":22},"冬夏季室外温、湿度和所需冷热量大小",{"key":27,"text":348,"correct":22},"夏季室外温湿度、冬季室外温度和所需冷热量大小",{"key":31,"text":350,"correct":29},"夏季室外温度、冬季室外温湿度和所需冷热量大小",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":27,"analysis":33},880079,"风管内设有电加热器时，风机应与电加热器联锁。电加热器前后各( )范围内的风管必须采用不燃保温材料。",[355,357,359,361],{"key":20,"text":356,"correct":22},"200mm",{"key":24,"text":358,"correct":22},"500mm",{"key":27,"text":360,"correct":29},"800mm",{"key":31,"text":362,"correct":22},"1000mm",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":31,"analysis":33},880080,"在工业建筑内位于顶层、层高为6m的厂房，室内设计采暖温度18℃，屋顶耗热量的室内计算温度应采用哪项?( )。 A.18℃",[367,369,371,373],{"key":20,"text":368,"correct":22},"18℃加温度梯度",{"key":24,"text":370,"correct":22},"18℃，但屋顶的耗热量增加4%",{"key":27,"text":372,"correct":22},"18a",{"key":31,"text":374,"correct":29},"但各项围护结构耗热量均增加4%",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":20,"analysis":33},880081,"关于住宅夏季空调方式的说法中，正确的是( )。",[379,381,383,385],{"key":20,"text":380,"correct":29},"尽管集中空调的制冷机能效比大大高于分体空调器，但分体空调方式通常比集中空调方式更节能",{"key":24,"text":382,"correct":22},"考虑同时使用系数，集中空调方式的装机容量通常只有分体空调方式的50%，因此集中空调方式的投资通常比分体空调方式少",{"key":27,"text":384,"correct":22},"集中空调方式的舒适性比分体空调方式好",{"key":31,"text":386,"correct":22},"集中空调方式节能、舒适、美观，因此是我国住宅空调的发展方向",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":20,"analysis":33},880082,"在进行高层建筑热水系统的竖向分区时，其分区应( )。",[391,393,395,397],{"key":20,"text":392,"correct":29},"与冷水系统分区一致",{"key":24,"text":394,"correct":22},"按卫生器具给水配件的最大工作压力进行",{"key":27,"text":396,"correct":22},"采用减压阀分区方式",{"key":31,"text":398,"correct":22},"采用分区热水箱供水方式",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":31,"analysis":33},880083,"所有低温热水地面辐射供暖工程中必需的构造层为( )。",[403,405,407,409],{"key":20,"text":404,"correct":22},"防潮层、绝热层、加热管、填充层、防水隔离层、找平层和面层",{"key":24,"text":406,"correct":22},"绝热层、加热管、填充层、防水隔离层、找平层和面层",{"key":27,"text":408,"correct":22},"绝热层、加热管、填充层、找平层和面层",{"key":31,"text":410,"correct":29},"加热管、填充层、找平层和面层",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":27,"analysis":33},880084,"关于低温热水地面辐射供暖房间的热负荷，下列哪个说法不正确？( )",[415,417,419,421],{"key":20,"text":416,"correct":22},"可取对流供暖系统计算总热负荷的90%～95%",{"key":24,"text":418,"correct":22},"局部辐射供暖时热负荷应进行附加",{"key":27,"text":420,"correct":29},"热媒供热量应该等于房间热负荷",{"key":31,"text":422,"correct":22},"高大空间可不进行高度附加",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":24,"analysis":33},880085,"判断一幢建筑是否节能，采用的判据应是下列哪一项？( )",[427,429,431,433],{"key":20,"text":428,"correct":22},"该建筑是否应用了地源热泵",{"key":24,"text":430,"correct":29},"该建筑全年单位面积平均能耗",{"key":27,"text":432,"correct":22},"该建筑空调供暖负荷大小",{"key":31,"text":434,"correct":22},"该建筑围护结构传热系数是否达到节能设计标准的要求",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":24,"analysis":33},880086,"下列冷库运行节能措施中，哪项是不正确的？( )",[439,441,443,445],{"key":20,"text":440,"correct":22},"控制冷间的合理使用温度",{"key":24,"text":442,"correct":29},"冻结间在不进行冻结加工时，可不再控制温度",{"key":27,"text":444,"correct":22},"尽量安排制冷机在夜间运行",{"key":31,"text":446,"correct":22},"同一制冷系统服务的冷间，应避免或减少不同蒸发温度冷间的并联运行时段",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":24,"analysis":33},880087,"空调机组内采用湿膜加湿，设加湿水温与空气湿球温度相同，则加湿段( )。",[451,453,455,457],{"key":20,"text":452,"correct":22},"空气温度升高、相对湿度增加、焓增加",{"key":24,"text":454,"correct":29},"空气温度下降、含湿量增加、焓基本不变",{"key":27,"text":456,"correct":22},"空气温度不变、相对湿度增加、焓增加",{"key":31,"text":458,"correct":22},"空气温度下降、含湿量增加、焓减少",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":24,"analysis":33},880088,"适用于冷热水系统的调节阀，一般应选用下列哪一种流量特性？( )",[463,465,467,469],{"key":20,"text":464,"correct":22},"直线型流量特性",{"key":24,"text":466,"correct":29},"等百分比型流量特性",{"key":27,"text":468,"correct":22},"抛物线型流量特性",{"key":31,"text":470,"correct":22},"快开型流量特性",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":20,"analysis":33},880089,"风机盘管宜按机组额定风量的比例设置高、中、低三挡风量，下列哪一项符合现行国家标准？( )",[475,477,479,481],{"key":20,"text":476,"correct":29},"1：0.75：0.5",{"key":24,"text":478,"correct":22},"1：0.75：0.45",{"key":27,"text":480,"correct":22},"1：0.6：0.4",{"key":31,"text":482,"correct":22},"1：0.5：0.3",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":31,"analysis":33},880090,"供暖体积热指标与下列哪个因素无关？( )",[487,489,491,493],{"key":20,"text":488,"correct":22},"建筑物的外形",{"key":24,"text":490,"correct":22},"建筑物的采光率",{"key":27,"text":492,"correct":22},"围护结构的传热系数",{"key":31,"text":494,"correct":29},"建筑物的建筑面积",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":24,"analysis":33},880091,"某地大气压力B=101325Pa，某车间工艺性空调设带水冷式表冷器的一次回风系统，取送风温差6℃，冷负荷为170kW，湿负荷为0.01kg\u002Fs，室内空气设计参数为：t=(23±1)℃、φ=55%，已知新回风混合点C的比焓h=53.2kJ\u002Fkg，取表冷器的出口相对湿度为90%，问：表冷器的冷凝水管的管径应为下列哪一项？( )",[499,501,503,505],{"key":20,"text":500,"correct":22},"DN32",{"key":24,"text":502,"correct":29},"DN40",{"key":27,"text":504,"correct":22},"DN50",{"key":31,"text":506,"correct":22},"DN80",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":20,"analysis":33},880092,"所有防烟分区共用一套排烟设备时，排烟风机的容量应按( )计算。",[511,513,515,517],{"key":20,"text":512,"correct":29},"最大防烟分区的面积",{"key":24,"text":514,"correct":22},"所有防烟分区面积之和",{"key":27,"text":516,"correct":22},"所有防烟分区面积的算术平均值",{"key":31,"text":518,"correct":22},"最小防烟分区的面积",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":27,"analysis":33},880093,"下列对空调系统方案的选择，比较合理的是( )。",[523,525,527,529],{"key":20,"text":524,"correct":22},"重要文献资料库采用风机盘管加新风空调系统",{"key":24,"text":526,"correct":22},"人员较多的会议室采用二次回风全空气系统",{"key":27,"text":528,"correct":29},"中型重要办公室采用VRV空调系统",{"key":31,"text":530,"correct":22},"游泳馆采用变风量空调系统",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":31,"analysis":33},880094,"某栋六层住宅建筑，设计分户热计量热水采暖系统，正确的做法是下列哪一项？",[535,537,539,541],{"key":20,"text":536,"correct":22},"采暖系统的总热负荷应计入向邻户传热引起的耗热量",{"key":24,"text":538,"correct":22},"计算系统供、回水管道时应计入向邻户传热引起的耗热量",{"key":27,"text":540,"correct":22},"户内散热器片数计算时不计入向邻户传热引起的耗热量",{"key":31,"text":542,"correct":29},"户内系统为双管系统，且热力入口设置流量调节阀",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":24,"analysis":33},880095,"热力网管道附件的设置，下列哪一项是错误的？( )",[547,549,551,553],{"key":20,"text":548,"correct":22},"热力网管道干线起点应安装关断阀门",{"key":24,"text":550,"correct":29},"热力网关断阀应采用单向密封阀门",{"key":27,"text":552,"correct":22},"热水热力网干线应装设分段阀门",{"key":31,"text":554,"correct":22},"热水管道的高点应安装放气装置",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":27,"analysis":33},880096,"一般情况下，当工况条件完全相同时，热泵机组的制热量大于制冷运行时的制冷量的原因是( )。",[559,561,563,565],{"key":20,"text":560,"correct":22},"制热运行时效率较高",{"key":24,"text":562,"correct":22},"制热运行时压缩机质量流量较大",{"key":27,"text":564,"correct":29},"制热量包括了压缩机输入功率",{"key":31,"text":566,"correct":22},"制热时冷凝温度较高",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":27,"analysis":33},880097,"下列关于燃气密度值大小的比较，正确的表述是( )。",[571,573,575,577],{"key":20,"text":572,"correct":22},"人工燃气密度大于空气密度",{"key":24,"text":574,"correct":22},"天然气密度大于空气密度",{"key":27,"text":576,"correct":29},"液化石油气密度大于空气密度",{"key":31,"text":578,"correct":22},"液化石油气密度小于空气密度",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":27,"analysis":33},880098,"高压离心式风机的风压( )。",[583,585,587,589],{"key":20,"text":584,"correct":22},"＞1000Pa",{"key":24,"text":586,"correct":22},"≥1000Pa",{"key":27,"text":588,"correct":29},"＞3000Pa",{"key":31,"text":590,"correct":22},"≥3000Pa",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":24,"analysis":33},880099,"同一台冷水机组，按中国标准检测得到的能效比，与按ARI标准监测得到的能效比相比较，其结果应是下列选项中的哪一项？",[595,597,599,601],{"key":20,"text":596,"correct":22},"偏高",{"key":24,"text":598,"correct":29},"相等",{"key":27,"text":600,"correct":22},"偏低",{"key":31,"text":602,"correct":22},"高10%",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":20,"analysis":33},880100,"在地板低温辐射采暖设计中，加热管内热媒流速( )。",[607,609,611,613],{"key":20,"text":608,"correct":29},"宜为0.35～0.5m\u002Fs，不应小于0.25m\u002Fs",{"key":24,"text":610,"correct":22},"宜为0.4～0.5m\u002Fs，不应小于0.3m\u002Fs",{"key":27,"text":612,"correct":22},"不应小于0.15m\u002Fs",{"key":31,"text":614,"correct":22},"不应大于0.4m\u002Fs",[616,619,622,625,628,631],{"id":15,"name":617,"category":7,"favorite":618},"领导干部任职前廉政法规知识测试题",92,{"id":620,"name":621,"category":7,"favorite":15},595,"建筑结构与设备",{"id":623,"name":624,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":626,"name":627,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":629,"name":630,"category":7,"favorite":8},534,"BIM工程师",{"id":632,"name":630,"category":7,"favorite":8},535]