[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-41":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":621},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,41,50,2054,[13,35,48,61,74,88,100,112,124,136,148,161,173,185,197,210,222,235,247,259,271,283,295,307,319,331,344,357,369,381,393,405,417,427,439,451,463,475,483,494,506,518,530,542,554,561,573,585,597,609],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},881851,2,"多选题","机械排烟系统的设计应符合的原则是( )。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","走道的机械排烟系统宜竖向设置，房间的机械排烟系统宜按防烟分区设置",true,{"key":24,"text":25,"correct":26},"B","防烟分区内的排烟口距最远点的水平距离不应超过20m",false,{"key":28,"text":29,"correct":26},"C","排烟口应设在顶棚上或靠近顶棚的墙面上。设在顶棚上的排烟口，距可燃构件或可燃物的距离不应小于2.00m",{"key":31,"text":32,"correct":22},"D","机械排烟系统中，当任一排烟口或排烟阀开启时，排烟风机应能自动起动","AD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},881852,"某办公建筑采用风机盘管十新风的集中空气调节系统，冷源为离心式冷水机组，夏季室内设计温度t=26℃，冷水供／回水设计温度为12\u002F17℃，下列哪几项说法是错误的？",[39,41,43,45],{"key":20,"text":40,"correct":26},"选用冷水供／回水温度为7\u002F12℃的机组，在设备中表明供／回水设计温度为12\u002F17℃的要求",{"key":24,"text":42,"correct":26},"采用常规风机盘管，同等风量，同等水量，同等阻力条件下，其传热系数保持不变",{"key":28,"text":44,"correct":22},"采用常规风机盘管，同等风量条件下，其输出冷量保持不变",{"key":31,"text":46,"correct":22},"同等冷量条件下，冷水供／回设计温度为12\u002F17℃的系统较7\u002F12℃的系统，所需水泵功率明显下降","CD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},881853,"物料输送过程采用密闭罩，吸风口的位置选择正确的是( )。",[52,54,56,58],{"key":20,"text":53,"correct":22},"斗式提升机输送50～150℃物料时，需于上部、下部均设置吸风口同时吸风",{"key":24,"text":55,"correct":22},"粉状物料下落时，物料的飞溅区不设置吸风口",{"key":28,"text":57,"correct":26},"皮带运输机上部吸风口至卸料槽距离至少为100mm",{"key":31,"text":59,"correct":22},"粉碎物料时，吸风口风速不宜大于2.0m\u002Fs","ABD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},881854,"下列关于选择空气源热泵机组的说法，正确的是哪几项?( )。",[65,67,69,71],{"key":20,"text":66,"correct":22},"严寒地区，不宜作为冬季供暖采用",{"key":24,"text":68,"correct":26},"对于夏热冬冷和夏热冬暖地区，应根据冬季热负荷选型，不足冷量可由冷水机组提供",{"key":28,"text":70,"correct":22},"融霜时间总和不应超过运行周期时间的20%",{"key":31,"text":72,"correct":26},"供暖时的允许最低室外温度，应与冬季供暖室外计算干球温度相适应","AC",{"id":75,"libraryId":5,"type":76,"typeLabel":77,"stem":78,"options":79,"answer":24,"analysis":34},881855,1,"单选题","一般情况下，重力循环供暖系统作用半径不宜超过( )。",[80,82,84,86],{"key":20,"text":81,"correct":26},"40m",{"key":24,"text":83,"correct":22},"50m",{"key":28,"text":85,"correct":26},"70m",{"key":31,"text":87,"correct":26},"100m",{"id":89,"libraryId":5,"type":76,"typeLabel":77,"stem":90,"options":91,"answer":24,"analysis":34},881856,"对于散发热、湿或有害物质的车间(或房间)在设计时应首先考虑采用( )。",[92,94,96,98],{"key":20,"text":93,"correct":26},"全面通风",{"key":24,"text":95,"correct":22},"局部通风",{"key":28,"text":97,"correct":26},"全面通风为主",{"key":31,"text":99,"correct":26},"局部通风为主",{"id":101,"libraryId":5,"type":76,"typeLabel":77,"stem":102,"options":103,"answer":31,"analysis":34},881857,"关于制冷机房的设备布置要求，下列哪一项不符合规范规定？",[104,106,108,110],{"key":20,"text":105,"correct":26},"机组与墙之间的净距不小于1m，与配电柜的距离不小于1.5m",{"key":24,"text":107,"correct":26},"机组与机组或其他设备之间的净距不小于1.2m",{"key":28,"text":109,"correct":26},"机组与其上方的电缆桥架的净距应大于Im",{"key":31,"text":111,"correct":22},"机房主要通道的宽度应大于1.8m",{"id":113,"libraryId":5,"type":76,"typeLabel":77,"stem":114,"options":115,"answer":28,"analysis":34},881858,"下列哪一项粉尘不得选用湿式除尘器净化？( )",[116,118,120,122],{"key":20,"text":117,"correct":26},"烟尘",{"key":24,"text":119,"correct":26},"石类尘",{"key":28,"text":121,"correct":22},"铝、镁混合尘",{"key":31,"text":123,"correct":26},"纤维尘",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":60,"analysis":34},881859,"涡旋式压缩机容积效率高的原因是( )。",[128,130,132,134],{"key":20,"text":129,"correct":22},"没有余隙容积",{"key":24,"text":131,"correct":22},"采用了柔性密封装置",{"key":28,"text":133,"correct":26},"转速较高",{"key":31,"text":135,"correct":22},"没有吸、排气阀",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":60,"analysis":34},881860,"有关散热器供暖系统制式的选择，合理的是( )。",[140,142,144,146],{"key":20,"text":141,"correct":22},"住宅楼采用垂直双管系统",{"key":24,"text":143,"correct":22},"办公楼采用上分式垂直单管跨越式系统",{"key":28,"text":145,"correct":26},"住宅楼采用垂直单管顺流式系统",{"key":31,"text":147,"correct":22},"办公楼采用上分式垂直双管系统",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":160,"analysis":34},881861,"文丘里湿式除尘器主要原理是：含尘气体的尘粒经文丘里管被管喉口部细化水滴捕集，直接进入沉淀罐，较少颗粒则由气流带入旋风脱水器，实现再次捕集尘粒和脱水，现有某文丘里湿式除尘器每经过一段时间运行后，经测定除尘效率有所下降，产生问题的主要原因可能是哪几项？",[152,154,156,158],{"key":20,"text":153,"correct":22},"水喷嘴堵塞",{"key":24,"text":155,"correct":26},"水气比过大",{"key":28,"text":157,"correct":22},"脱水器效率降低",{"key":31,"text":159,"correct":22},"水气比过低","ACD",{"id":162,"libraryId":5,"type":76,"typeLabel":77,"stem":163,"options":164,"answer":28,"analysis":34},881862,"《建筑设计防火规范》不适用于下列哪一类别的建筑物？",[165,167,169,171],{"key":20,"text":166,"correct":26},"多层工业建筑",{"key":24,"text":168,"correct":26},"地下民用建筑",{"key":28,"text":170,"correct":22},"建筑高度超过24m的高层工业建筑",{"key":31,"text":172,"correct":26},"无窗厂房",{"id":174,"libraryId":5,"type":76,"typeLabel":77,"stem":175,"options":176,"answer":31,"analysis":34},881863,"确定围护结构最小传热阻的冬季室外计算温度，应采用( )。",[177,179,181,183],{"key":20,"text":178,"correct":26},"历年平均不保证1天的日平均温度",{"key":24,"text":180,"correct":26},"历年最冷月平均温度",{"key":28,"text":182,"correct":26},"历年平均不保证5天的日平均温度",{"key":31,"text":184,"correct":22},"根据围护结构的热惰性指标确定",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":160,"analysis":34},881864,"某多层住宅采用集中热水供暖系统，下列哪些系统适用于采用分户计量的集中热水供暖？( )",[189,191,193,195],{"key":20,"text":190,"correct":22},"单管水平跨越式系统",{"key":24,"text":192,"correct":26},"单管垂直串联系统",{"key":28,"text":194,"correct":22},"双管上供下回系统",{"key":31,"text":196,"correct":22},"双管水平并联式系统",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":209,"analysis":34},881865,"上供下回式重力循环热水供暖系统的作用压头与下列哪些因素有关？( )",[201,203,205,207],{"key":20,"text":202,"correct":22},"供、回水温度",{"key":24,"text":204,"correct":22},"散热器距热源的垂直距离",{"key":28,"text":206,"correct":22},"楼层数",{"key":31,"text":208,"correct":22},"系统的作用半径","ABCD",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":160,"analysis":34},881866,"建筑排水设置通气系统的目的是( )。",[214,216,218,220],{"key":20,"text":215,"correct":22},"平衡管内的正负压，保护水封",{"key":24,"text":217,"correct":26},"消除水流噪声",{"key":28,"text":219,"correct":22},"提高管道的流通能力",{"key":31,"text":221,"correct":22},"排除排水系统中的有害气体",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":234,"analysis":34},881867,"影响洁净室室内外压差风量的因素，是下列哪几项？",[226,228,230,232],{"key":20,"text":227,"correct":22},"室外风速",{"key":24,"text":229,"correct":22},"建筑结构的气密性",{"key":28,"text":231,"correct":26},"建筑物方位和不同朝向的围护面积",{"key":31,"text":233,"correct":26},"洁净室面积","AB",{"id":236,"libraryId":5,"type":76,"typeLabel":77,"stem":237,"options":238,"answer":20,"analysis":34},881868,"冷库制冷系统中，气体制冷剂管道管径应按其允许压力降和立管中( )制冷剂的流速综合考虑。",[239,241,243,245],{"key":20,"text":240,"correct":22},"带油向上的",{"key":24,"text":242,"correct":26},"油可以自然沉降的",{"key":28,"text":244,"correct":26},"阻力最合理的",{"key":31,"text":246,"correct":26},"阻力与水平管必须一致的",{"id":248,"libraryId":5,"type":76,"typeLabel":77,"stem":249,"options":250,"answer":31,"analysis":34},881869,"确定冷库冷负荷的计算内容时，下列哪一项是正确合理的？",[251,253,255,257],{"key":20,"text":252,"correct":26},"围护结构、食品及其包装和运输工具、通风换气、照明等形成的热流量",{"key":24,"text":254,"correct":26},"围护结构、食品、通风换气、照明以及人员形成的操作等热流量",{"key":28,"text":256,"correct":26},"围护结构、食品及其包装和运输工具、通风换气、人员形成的热流量",{"key":31,"text":258,"correct":22},"围护结构、照明以及操作人员工作、通风换气、食品及其包装和运输工具等形成的热流量",{"id":260,"libraryId":5,"type":76,"typeLabel":77,"stem":261,"options":262,"answer":28,"analysis":34},881870,"高效和超高效空气过滤器出厂前进行检漏，一般采用计数扫描法。不合格判定标准之一是定量试验下的局部透过率限值，其限值为额定风量下的该类别过滤器穿透率的( )o",[263,265,267,269],{"key":20,"text":264,"correct":26},"1倍",{"key":24,"text":266,"correct":26},"5倍",{"key":28,"text":268,"correct":22},"10倍",{"key":31,"text":270,"correct":26},"20倍",{"id":272,"libraryId":5,"type":76,"typeLabel":77,"stem":273,"options":274,"answer":24,"analysis":34},881871,"高层民用建筑中的通廊式住宅，在哪种情况下应设防烟楼梯？( )",[275,277,279,281],{"key":20,"text":276,"correct":26},"10层以上",{"key":24,"text":278,"correct":22},"11层以上",{"key":28,"text":280,"correct":26},"12层以上",{"key":31,"text":282,"correct":26},"19层及19层以上",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":60,"analysis":34},881872,"采用冷冻减湿机处理后的空气，其状态参数变化的正确说法为( )。",[287,289,291,293],{"key":20,"text":288,"correct":22},"温度升高",{"key":24,"text":290,"correct":22},"含湿量降低",{"key":28,"text":292,"correct":26},"相对湿度不变",{"key":31,"text":294,"correct":22},"焓值增加",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":209,"analysis":34},881873,"建筑物内排水管道的布置要求是( )。",[299,301,303,305],{"key":20,"text":300,"correct":22},"卫生器具至排出管的距离应最短，管道转弯应最少",{"key":24,"text":302,"correct":22},"排水管不得布置在遇水会引起燃烧、爆炸或损坏的原料、产品和设备的上面",{"key":28,"text":304,"correct":22},"排水管道不得敷设在对生产工艺或卫生有特殊要求的生产厂房内，不得穿越食品和贵重商品库房、通风小室、变配电间、电梯机房、烟道和风道下行上给式系统，当入户支管上有分户计量表时，应在各供水立管顶设自动排气阀",{"key":31,"text":306,"correct":22},"排水管道不得穿越设备基础，不宜穿越地基梁",{"id":308,"libraryId":5,"type":76,"typeLabel":77,"stem":309,"options":310,"answer":31,"analysis":34},881874,"关于锅炉房锅炉台数的选择，下列说法错误的是( )。",[311,313,315,317],{"key":20,"text":312,"correct":26},"新建锅炉房一般不宜超过5台",{"key":24,"text":314,"correct":26},"改建锅炉房一般不宜超过7台",{"key":28,"text":316,"correct":26},"锅炉房的锅炉台数不宜少于2台",{"key":31,"text":318,"correct":22},"锅炉房不得只设置1台锅炉",{"id":320,"libraryId":5,"type":76,"typeLabel":77,"stem":321,"options":322,"answer":31,"analysis":34},881875,"关于风机盘管的供冷性能试验工况，建议空气状态参数应是下列哪一项？",[323,325,327,329],{"key":20,"text":324,"correct":26},"干球温度25℃，湿球温度19℃",{"key":24,"text":326,"correct":26},"干球温度26℃，湿球温度19.5℃",{"key":28,"text":328,"correct":26},"干球温度22℃，湿球温度20℃",{"key":31,"text":330,"correct":22},"干球温度27℃，湿球温度19.5℃",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":343,"analysis":34},881876,"现场组装的静电除尘器，其阴阳极板之间的间距允许偏差，下列符合相关规定的是( )。",[335,337,339,341],{"key":20,"text":336,"correct":26},"阳极极板高度＞7m，为5mm",{"key":24,"text":338,"correct":22},"阳极极板高度＞7m，为10mm",{"key":28,"text":340,"correct":22},"阳极极板高度≤7m，为5mm",{"key":31,"text":342,"correct":26},"阳极极板高度≤7m，为10mm","BC",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":356,"analysis":34},881877,"吸收式制冷与蒸气压缩式制冷比较，下列说法正确的是( )。",[348,350,352,354],{"key":20,"text":349,"correct":26},"目的不同",{"key":24,"text":351,"correct":22},"能量补偿方式不同",{"key":28,"text":353,"correct":22},"使用工质不同",{"key":31,"text":355,"correct":22},"都使用液态制冷剂","BCD",{"id":358,"libraryId":5,"type":76,"typeLabel":77,"stem":359,"options":360,"answer":31,"analysis":34},881878,"某非单向洁净室，静态下测试室内空气含尘浓度(对0.5μm)为100000pc\u002Fm3.如果人员密度为0.3人／㎡，预计动态下室内空气含尘浓度(对O.5μm)约为下列哪一项？",[361,363,365,367],{"key":20,"text":362,"correct":26},"10000pc\u002Fm3",{"key":24,"text":364,"correct":26},"20000pc\u002Fm3",{"key":28,"text":366,"correct":26},"30000pc\u002Fm3",{"key":31,"text":368,"correct":22},"50000pc\u002Fm3",{"id":370,"libraryId":5,"type":76,"typeLabel":77,"stem":371,"options":372,"answer":28,"analysis":34},881879,"设计采暖系统时，下列哪一项是错误的？",[373,375,377,379],{"key":20,"text":374,"correct":26},"热水系统水质的溶解氧应小于或等于0.1mg\u002FL",{"key":24,"text":376,"correct":26},"蒸汽采暖系统中不应采用钢制散热器",{"key":28,"text":378,"correct":22},"在同一热水系统中，钢制和铝制散热器可同时使用",{"key":31,"text":380,"correct":26},"热水系统管道内水速不小于0.25m\u002Fs时，可无坡度敷设",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":60,"analysis":34},881880,"战时为物资库的人防地下室通风系统的设置要求( )是不正确的。",[385,387,389,391],{"key":20,"text":386,"correct":22},"应设置清洁式通风",{"key":24,"text":388,"correct":22},"应设置隔绝式通风",{"key":28,"text":390,"correct":26},"应设置清洁式和隔绝式通风",{"key":31,"text":392,"correct":22},"应设置滤毒式通风",{"id":394,"libraryId":5,"type":76,"typeLabel":77,"stem":395,"options":396,"answer":31,"analysis":34},881881,"两台相同型号的风机同时运行的叠加噪声值是( )。",[397,399,401,403],{"key":20,"text":398,"correct":26},"单台风机的噪声值",{"key":24,"text":400,"correct":26},"单台风机噪声值的2倍",{"key":28,"text":402,"correct":26},"单台风机噪声值的3倍",{"key":31,"text":404,"correct":22},"单台风机噪声值加3dB",{"id":406,"libraryId":5,"type":76,"typeLabel":77,"stem":407,"options":408,"answer":31,"analysis":34},881882,"建筑室内给水系统为满足使用和检修要求应设置阀门，下列哪一项是错误的？( )",[409,411,413,415],{"key":20,"text":410,"correct":26},"人户管起始端",{"key":24,"text":412,"correct":26},"各种设备的配水管上",{"key":28,"text":414,"correct":26},"各立管的起始端",{"key":31,"text":416,"correct":22},"配水点大于等于8个的配水支管上",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":33,"analysis":34},881883,"洁净室的新风量应该是( )中的最大值。",[421,423,425,426],{"key":20,"text":422,"correct":22},"补偿室内排风量和保持室内正压值所需新鲜空气量之和",{"key":24,"text":424,"correct":26},"10%的新风比",{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":22},{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":47,"analysis":34},881884,"蒸汽供热系统水力计算与热水供热系统的不同点在于( )。",[431,433,435,437],{"key":20,"text":432,"correct":26},"任务和目的不同",{"key":24,"text":434,"correct":26},"基本计算公式不同.",{"key":28,"text":436,"correct":22},"包括蒸汽网路和凝结水路两部分的水力计算",{"key":31,"text":438,"correct":22},"管壁粗糙度不同",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":47,"analysis":34},881885,"直流式全新风空调系统应用于下列哪几种情况？( )",[443,445,447,449],{"key":20,"text":444,"correct":26},"室内散发余热、余湿较多时",{"key":24,"text":446,"correct":26},"空调区换气次数较高时",{"key":28,"text":448,"correct":22},"夏季空调系统的回风比焓高于室外空气比焓时",{"key":31,"text":450,"correct":22},"空调区排风量大于按负荷计算的送风量时",{"id":452,"libraryId":5,"type":76,"typeLabel":77,"stem":453,"options":454,"answer":28,"analysis":34},881886,"地源热泵系统地埋管换热器的换热量应满足( )。",[455,457,459,461],{"key":20,"text":456,"correct":26},"用户系统用冷量或用热量设计负荷的要求",{"key":24,"text":458,"correct":26},"用户系统用冷量或用热量在计算周期内总设计负荷的要求",{"key":28,"text":460,"correct":22},"热泵系统最大释热量或最大吸热量的要求",{"key":31,"text":462,"correct":26},"热泵系统在计算周期内总释热量或总吸热量的要求",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":160,"analysis":34},881887,"下列关于噪声的说法中，不正确的是( )。",[467,469,471,473],{"key":20,"text":468,"correct":22},"两台相同型号的风机同时运行的叠加噪声值是单台噪声值的两倍",{"key":24,"text":470,"correct":26},"NR噪声评价曲线的噪声值比A声级计测量值低5dB",{"key":28,"text":472,"correct":22},"噪声仪是通过测量声强来测量噪声的强弱的",{"key":31,"text":474,"correct":22},"风机在低效率工况下的噪声比在高效率工况下的噪声小",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":356,"analysis":34},881888,"某空调机组表冷器设计供回水温度为12\u002F17℃，采用电动两通调节阀进行控制，安装方式如下所示，其中 A， B、C为水平管，D为垂直管，指出其中的错误选项？",[479,480,481,482],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":22},{"key":28,"text":34,"correct":22},{"key":31,"text":34,"correct":22},{"id":484,"libraryId":5,"type":76,"typeLabel":77,"stem":485,"options":486,"answer":31,"analysis":34},881889,"以下有关静电除尘器性能的描述，哪一项是错误的？",[487,489,491,493],{"key":20,"text":488,"correct":26},"和其他高效除尘器相比，静电除尘器的阻力较低",{"key":24,"text":490,"correct":26},"可处理400℃以下的高温含尘气体",{"key":28,"text":492,"correct":26},"对于粒径1～2μm以上的粉尘，静电除尘器的效率可达98%～99%",{"key":31,"text":34,"correct":22},{"id":495,"libraryId":5,"type":76,"typeLabel":77,"stem":496,"options":497,"answer":24,"analysis":34},881890,"按照我国现行节能设计标准，哪些建筑气候分区的居住建筑可不考虑冬季供暖？( )",[498,500,502,504],{"key":20,"text":499,"correct":26},"夏热冬冷地区、夏热冬暖地区、温和地区",{"key":24,"text":501,"correct":22},"温和地区",{"key":28,"text":503,"correct":26},"夏热冬暖地区、温和地区",{"key":31,"text":505,"correct":26},"夏热冬暖地区",{"id":507,"libraryId":5,"type":76,"typeLabel":77,"stem":508,"options":509,"answer":31,"analysis":34},881891,"高效和超高效空气过滤器出厂检验的项目包括：外观、尺寸偏差、检漏、效率、阻力。出厂检验数量为( )。",[510,512,514,516],{"key":20,"text":511,"correct":26},"抽检5\u002F100",{"key":24,"text":513,"correct":26},"抽检1\u002F3",{"key":28,"text":515,"correct":26},"抽检1\u002F100",{"key":31,"text":517,"correct":22},"每台检验B类根据需要)",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":160,"analysis":34},881892,"关于溴化锂吸收式制冷机的性能，下列说法正确的是( )。",[522,524,526,528],{"key":20,"text":523,"correct":22},"加热蒸汽压力每提高0.01MPa，制冷量增加3%～5%",{"key":24,"text":525,"correct":26},"制冷量基本上与溶液循环量成反比",{"key":28,"text":527,"correct":22},"当其他参数不变时，冷冻水出口温度每升高1℃，制冷量增加4%～6%",{"key":31,"text":529,"correct":22},"冷却水进口温度每降低1℃，制冷量约增加4%",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":160,"analysis":34},881893,"关于风机盘管加新风系统的下列表述中，哪几项是正确的？( )",[534,536,538,540],{"key":20,"text":535,"correct":22},"新风处理到室内等温线，风机盘管要承担部分新风湿负荷",{"key":24,"text":537,"correct":26},"新风处理到室内等湿线，风机盘管要承担全部室内显热冷负荷",{"key":28,"text":539,"correct":22},"新风处理到室内等焓线，风机盘管要承担全部室内冷负荷",{"key":31,"text":541,"correct":22},"新风处理到小于室内等温线，风机盘管要承担部分室内显热冷负荷",{"id":543,"libraryId":5,"type":76,"typeLabel":77,"stem":544,"options":545,"answer":28,"analysis":34},881894,"冷热水空气源热泵空调机组冬季设计工况的性能系数不应小于( )。",[546,548,550,552],{"key":20,"text":547,"correct":26},"1.5",{"key":24,"text":549,"correct":26},"1.8",{"key":28,"text":551,"correct":22},"2.0",{"key":31,"text":553,"correct":26},"2.6",{"id":555,"libraryId":5,"type":76,"typeLabel":77,"stem":34,"options":556,"answer":31,"analysis":34},881895,[557,558,559,560],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":22},{"id":562,"libraryId":5,"type":76,"typeLabel":77,"stem":563,"options":564,"answer":20,"analysis":34},881896,"下列哪种食品冷却方式无食品干耗？( )",[565,567,569,571],{"key":20,"text":566,"correct":22},"冷水冷却",{"key":24,"text":568,"correct":26},"通风冷却",{"key":28,"text":570,"correct":26},"真空冷却",{"key":31,"text":572,"correct":26},"差压式冷却",{"id":574,"libraryId":5,"type":76,"typeLabel":77,"stem":575,"options":576,"answer":31,"analysis":34},881897,"公共建筑节能设计标准中规定了空调热水系统的输送能效比限值，所规定的两管制热水管道数值不适用的热水系统应是下列选项中的哪一项？",[577,579,581,583],{"key":20,"text":578,"correct":26},"风冷热泵热水系统",{"key":24,"text":580,"correct":26},"水源热泵热水系统",{"key":28,"text":582,"correct":26},"燃气锅炉热水系统",{"key":31,"text":584,"correct":22},"燃气直燃机热水系统",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":33,"analysis":34},881898,"对于空调工程水系统的阀门进行强度和严格试验，正确的做法是下列哪几项？( )",[589,591,593,595],{"key":20,"text":590,"correct":22},"对在主干管上起切断作用的阀，全部检查",{"key":24,"text":592,"correct":26},"对于工作压力不大于1.0MPa的阀，按总数的20%检查",{"key":28,"text":594,"correct":26},"对不在主干管上起切断作用的阀和工作压力≤1.0MPa的阀总数的10%检查",{"key":31,"text":596,"correct":22},"对不在主干管上起切断作用的阀和工作压力≤1.0MPa的阀，不做检查，在系统试压中检查",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":73,"analysis":34},881899,"自动喷水灭火系统的各组件中，火灾时能起报警作用的装置是下列哪几项？( )",[601,603,605,607],{"key":20,"text":602,"correct":22},"水流指示器",{"key":24,"text":604,"correct":26},"末端试水装置",{"key":28,"text":606,"correct":22},"报警阀组",{"key":31,"text":608,"correct":26},"止回阀",{"id":610,"libraryId":5,"type":76,"typeLabel":77,"stem":611,"options":612,"answer":31,"analysis":34},881900,"舒适性空调房间，其围护结构的热工参数应选( )。",[613,615,617,619],{"key":20,"text":614,"correct":26},"外墙传热系数K值为1.0W／(㎡？K)，顶棚传热系数K值为1.5W\u002F(㎡？K)，内墙传热系数K值为2.0W／(㎡？K)",{"key":24,"text":616,"correct":26},"外墙传热系数K值为2.0W／(㎡？K)，顶棚传热系数K值为0.8W／(㎡？K)，内墙传热系数K值为2.0W／(㎡？K)",{"key":28,"text":618,"correct":26},"外墙传热系数K值为1.5W／(㎡？K)，顶棚传热系数K值为1.5W／(㎡？K)，内墙传热系数K值为1.0W／(㎡？K)",{"key":31,"text":620,"correct":22},"外墙传热系数K值为1.5W／(㎡？K)，顶棚传热系数K值为1.2W／(㎡？K)，内墙传热系数K值为2.0W／(㎡？K)",[622,625,628,631,634,637],{"id":76,"name":623,"category":7,"favorite":624},"领导干部任职前廉政法规知识测试题",92,{"id":626,"name":627,"category":7,"favorite":76},595,"建筑结构与设备",{"id":629,"name":630,"category":7,"favorite":76},715,"招标采购专业知识与法律法规",{"id":632,"name":633,"category":7,"favorite":76},848,"市政方向-通用基础",{"id":635,"name":636,"category":7,"favorite":8},534,"BIM工程师",{"id":638,"name":636,"category":7,"favorite":8},535]