[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-40":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":617},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,40,50,2054,[13,35,48,61,74,83,95,107,118,131,143,155,168,180,193,205,218,231,239,248,260,272,284,296,308,320,332,344,356,366,378,390,402,415,426,438,450,459,471,483,495,507,519,531,543,555,567,579,591,605],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},881801,2,"多选题","对散发有害气体和余热车间进行自然通风时，下列措施中不合理的是( )。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","应保证人员操作区位于中和界之下",false,{"key":24,"text":25,"correct":26},"B","人员操作区可以在中和界之上",true,{"key":28,"text":29,"correct":26},"C","为减小排风窗面积，中和界高度应尽可能低",{"key":31,"text":32,"correct":22},"D","为减小排风窗面积，中和界高度不应太高","BC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},881802,"下列几种空调水系统大温差供冷的说法中，正确的是( )。",[39,41,43,45],{"key":20,"text":40,"correct":22},"加大供回水温差一定能起到节能效果",{"key":24,"text":42,"correct":26},"大温差供冷适用于区域供冷的情况",{"key":28,"text":44,"correct":22},"大温差供冷适用于中小型单体建筑",{"key":31,"text":46,"correct":26},"区域供冷的空调冷水供回水温差不宜小于7℃，冰蓄冷系统不应小于9℃","BD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},881803,"蓄冷技术按蓄冷介质分为( )。",[52,54,56,58],{"key":20,"text":53,"correct":26},"水蓄冷",{"key":24,"text":55,"correct":26},"共晶盐蓄冷",{"key":28,"text":57,"correct":22},"冰晶蓄冷",{"key":31,"text":59,"correct":26},"冰蓄冷","ABD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},881804,"位于建筑地下室内的供暖系统干管需要设置补偿器，下列哪些做法是正确的？( )",[65,67,69,71],{"key":20,"text":66,"correct":26},"计算管道热伸长量时，低温一般取-5℃",{"key":24,"text":68,"correct":22},"为减小推力，宜采用套筒补偿器",{"key":28,"text":70,"correct":26},"应在靠近补偿器处设置导向支架",{"key":31,"text":72,"correct":22},"导向支架受力应包括重力、推力和摩擦力","AC",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":82,"analysis":34},881805,"《人防设计规范》中规定了进风口部的管道连接的正确设计要求，设计中进风口部的通风管由扩散室侧墙穿入和由扩散室后墙穿入的四组做法，管道连接方式不符合规范规定的应是下列哪几项？( )",[78,79,80,81],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":22},{"key":28,"text":34,"correct":22},{"key":31,"text":34,"correct":26},"AD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":60,"analysis":34},881806,"某高层建筑的中庭面积为850㎡，平均净高度为25m，设计选取合理的机械排烟量时，错误的应是下列哪几项？",[87,89,91,93],{"key":20,"text":88,"correct":26},"51000m3\u002Fh",{"key":24,"text":90,"correct":26},"85000m3\u002Fh",{"key":28,"text":92,"correct":22},"102000m3\u002Fh",{"key":31,"text":94,"correct":26},"127500m3\u002Fh",{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":97,"options":98,"answer":47,"analysis":34},881807,"直燃式溴化锂吸收式制冷机机房设计的核心问题是保证满足消防与安全要求，下列哪几项是正确的？( )",[99,101,103,105],{"key":20,"text":100,"correct":22},"多台机组不应共用烟道",{"key":24,"text":102,"correct":26},"机房应设置可靠的通风装置和事故排风装置",{"key":28,"text":104,"correct":22},"机房不宜布置在地下室",{"key":31,"text":106,"correct":26},"保证燃气管道严密，与电气设备和其他管道必要的净距离，以及放散管管径≥20.mm",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":109,"options":110,"answer":73,"analysis":34},881808,"对于公共卫生间的通风设计，下列要求哪几项是错误的？( )",[111,113,115,117],{"key":20,"text":112,"correct":26},"宜设置机械排风系统",{"key":24,"text":114,"correct":22},"应保证卫生间对其他公共区域维持负压",{"key":28,"text":116,"correct":26},"通风量应按污染物发生情况计算",{"key":31,"text":34,"correct":22},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":130,"analysis":34},881809,"下列关于下送风方式的说法，不正确的是( )。",[122,124,126,128],{"key":20,"text":123,"correct":26},"下送风方式的送风温差减小、风量增加、因此其风系统的能耗增加",{"key":24,"text":125,"correct":22},"地板送风方式直接将新鲜的空气送入人员工作区，因此空气品质好",{"key":28,"text":127,"correct":26},"下送风方式可以实现分层空调，使系统能耗减少",{"key":31,"text":129,"correct":26},"下送风方式可能使系统能耗增加","ACD",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":73,"analysis":34},881810,"下列哪几项是溶液除湿空调系统的主要特点？( )",[135,137,139,141],{"key":20,"text":136,"correct":26},"空气可达到低含湿量，系统复杂，初投资高，可实现运行节能",{"key":24,"text":138,"correct":22},"空气难达到低含湿量，系统复杂，初投资高，运行能耗高",{"key":28,"text":140,"correct":26},"空气可达到低含湿量，可利用低品位热能，可实现热回收，可实现运行节能",{"key":31,"text":142,"correct":22},"空气可达到低含湿量，可利用低品位热能，可实现热回收，无法实现运行节能",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":60,"analysis":34},881811,"某蒸汽供暖系统供汽压力为0.6MPa，需要减压至0.07MPa。下列哪些做法是正确的？( )",[147,149,151,153],{"key":20,"text":148,"correct":26},"采用两级减压，串联两个减压装置",{"key":24,"text":150,"correct":26},"第二级减压阀应采用波纹式减压阀",{"key":28,"text":152,"correct":22},"也可以串联两个截止阀减压",{"key":31,"text":154,"correct":26},"应设置旁通管和旁通阀",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":167,"analysis":34},881812,"关于公共建筑空调系统节能的说法正确的应是下列哪几项？",[159,161,163,165],{"key":20,"text":160,"correct":22},"公共建筑空调系统只要采用了各种先进的技术设备，就能实现节能领先水平",{"key":24,"text":162,"correct":22},"公共建筑空调系统的能耗高低仅由设计确定",{"key":28,"text":164,"correct":26},"公共建筑空调系统的精细运行管理能够降低运行能耗",{"key":31,"text":166,"correct":26},"公共建筑设置基于物联网的能耗监测系统是实现降低空调系统能耗的重要手段之一","CD",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":33,"analysis":34},881813,"关于冷库的冷却设备负荷和冷间机械负荷，下列说法正确的是( )。",[172,174,176,178],{"key":20,"text":173,"correct":22},"冷却设备负荷和冷间机械负荷数值相等",{"key":24,"text":175,"correct":26},"根据冷却设备负荷选择冷间的冷却设备",{"key":28,"text":177,"correct":26},"根据冷间机械负荷选择冷库的制冷负荷",{"key":31,"text":179,"correct":22},"将所有冷间的计算热流量相加，其值为冷却设备负荷",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":192,"analysis":34},881814,"下列关于海水源热泵空调方式的表述中，不正确的是( )。",[184,186,188,190],{"key":20,"text":185,"correct":26},"由于海南省海岸线较长，且冬季海水温度较高，海水源热泵空调系统的制热效率很高，因此海南省沿海建筑应大力推广海水源热泵空调技术",{"key":24,"text":187,"correct":26},"海水源热泵是节能空调技术，因此海南省沿海的办公建筑宜采用海水源热泵空调方式",{"key":28,"text":189,"correct":26},"在海南省沿海的住宅中适合推广海水源热泵空调技术",{"key":31,"text":191,"correct":22},"应通过综合技术经济性比较来确定是否采用该技术","ABC",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":130,"analysis":34},881815,"设某室内游泳池冬季池区上部的空气参数保持不变，整个池壁和底面均为绝热，池底部安装加热装置，池水能均匀混合。下列哪几项表述是正确的？",[197,199,201,203],{"key":20,"text":198,"correct":26},"加热装置不加热时，稳定后池水温度约等于室内空气湿球温度",{"key":24,"text":200,"correct":22},"加热装置开启后(加热强度恒定)，池水温度一定高于室内空气干球温度",{"key":28,"text":202,"correct":26},"加热装置的加热量合适时，池水温度可维持在室内空气湿球温度与干球温度之间",{"key":31,"text":204,"correct":26},"池水温度取决于加热量，与室内空气参数无关",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":217,"analysis":34},881816,"采用全负荷蓄冷方式时，系统有下列哪些运行工况？( )",[209,211,213,215],{"key":20,"text":210,"correct":26},"蓄冷",{"key":24,"text":212,"correct":26},"释冷供冷",{"key":28,"text":214,"correct":22},"释冷十制冷机供冷",{"key":31,"text":216,"correct":22},"蓄冷十制冷机供冷","AB",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":230,"analysis":34},881817,"分户热计量热水集中供暖系统，应在建筑物热力入口处设置( )。",[222,224,226,228],{"key":20,"text":223,"correct":22},"分水器",{"key":24,"text":225,"correct":26},"除污器",{"key":28,"text":227,"correct":26},"热量表",{"key":31,"text":229,"correct":26},"差压或流量调节装置","BCD",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":192,"analysis":34},881818,"人防二等人员掩蔽所滤毒通风时，主要出入口最小防毒通道的换气次数( )是不符合规范的。",[235,236,237,238],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":26},{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":22},{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":192,"analysis":34},881819,"双级蒸汽压缩式制冷循环的合理中间压力P，可以根据不同情况采用下列哪几项方法计算？",[243,244,245,247],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":26},{"key":28,"text":246,"correct":26},"按现有双机制冷压缩机的高、低压压缩机的容积比确定",{"key":31,"text":34,"correct":22},{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":82,"analysis":34},881820,"采用地板辐射供暖方式时，哪些是确定“所需单位面积有效散热量”的因素？( )",[252,254,256,258],{"key":20,"text":253,"correct":26},"房间计算供暖负荷的0.90～0.95",{"key":24,"text":255,"correct":22},"地面层的材质",{"key":28,"text":257,"correct":22},"辐射体表面的温度限制",{"key":31,"text":259,"correct":26},"地面覆盖物对散热量的折减",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":60,"analysis":34},881821,"关于两管制系统和四管制系统，下列表述正确的是( )。",[264,266,268,270],{"key":20,"text":265,"correct":26},"两管制系统是目前我国绝大多数民用建筑采用的空调水系统方式",{"key":24,"text":267,"correct":26},"两管制系统的特点是冷、热源切换使用，末端装置只能供冷或供热",{"key":28,"text":269,"correct":22},"四管制系统适用于建筑物功能较单一、舒适性要求不高的场合",{"key":31,"text":271,"correct":26},"四管制系统可实现同时供冷供热，可对空气实现冷却、再热处理",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":192,"analysis":34},881822,"冬季空调采用喷口送热风时，气流会向上弯曲，下列哪几项叙述是错误的？( )",[276,278,280,282],{"key":20,"text":277,"correct":26},"送风温差越小，则弯曲程度越大",{"key":24,"text":279,"correct":26},"送风速度越大，则弯曲程度越大",{"key":28,"text":281,"correct":26},"送风口直径越小，则弯曲程度越大",{"key":31,"text":283,"correct":22},"送风速度越小，则弯曲程度越大",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":167,"analysis":34},881823,"下列关于非等温自由射流，叙述正确的是( )。",[288,290,292,294],{"key":20,"text":289,"correct":22},"送风温度高于室内空气温度时为冷射流",{"key":24,"text":291,"correct":22},"非等温射流进入房间后，热量交换快于动量交换，因而温度衰减快于速度衰减",{"key":28,"text":293,"correct":26},"非等温射流在其射程中，由于与周围空气密度不同，所受浮力与重力不同而发生弯曲，冷射流向下弯曲",{"key":31,"text":295,"correct":26},"决定射流弯曲程度的主要因素是阿基米德数，是表征浮力和惯性力的无因次比值",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":130,"analysis":34},881824,"采用燃气红外线辐射作为建筑全面供暖，下列概念正确的是( )。",[300,302,304,306],{"key":20,"text":301,"correct":26},"建筑物的供暖负荷只计算围护结构耗热量",{"key":24,"text":303,"correct":22},"燃气红外线辐射器的输出功率应不小于建筑物的供暖负荷",{"key":28,"text":305,"correct":26},"人体所需要的辐射强度与室外温度成反比、与舒适温度成正比",{"key":31,"text":307,"correct":26},"人体实际接受到的辐射强度与辐射器的安装高度成反比",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":82,"analysis":34},881825,"水果、蔬菜在气调储藏时，应保证下列哪几项措施？( )",[312,314,316,318],{"key":20,"text":313,"correct":26},"抑制食品的呼吸作用",{"key":24,"text":315,"correct":22},"增加食品的呼吸强度",{"key":28,"text":317,"correct":22},"加大冷库的自然换气量",{"key":31,"text":319,"correct":26},"控制冷库的气体成分",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":73,"analysis":34},881826,"关于避风天窗，下列说法正确的是( )。",[324,326,328,330],{"key":20,"text":325,"correct":26},"矩形天窗采光面积大，窗孔集中在车间中部，当热源集中在室内中部时，便于气流迅速排出",{"key":24,"text":327,"correct":22},"矩形天窗的缺点是天窗高度受屋架高度限制，清灰、排水比较困难",{"key":28,"text":329,"correct":26},"下沉式天窗的特点是把部分屋面下移，放在屋架的下弦下，利用屋架本身的高度(即上、下弦之间的空间)形成天窗",{"key":31,"text":331,"correct":22},"下沉式天窗的缺点是建筑结构复杂，造价高",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":230,"analysis":34},881827,"战时物资库的通风系统( )是应设置的。",[336,338,340,342],{"key":20,"text":337,"correct":22},"过滤吸收器",{"key":24,"text":339,"correct":26},"粗效过滤器",{"key":28,"text":341,"correct":26},"风机",{"key":31,"text":343,"correct":26},"密闭阀门",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":167,"analysis":34},881828,"下列关于溴化锂吸收式冷水机组的说法，哪些是错误的？( )",[348,350,352,354],{"key":20,"text":349,"correct":22},"溴化锂冷水机组的冷却水温越低，COP越高，但冷却水温度过低时，可能出现溶液结晶现象",{"key":24,"text":351,"correct":22},"与蒸气压缩式制冷机组相比，名义工况相同冷量的溴化锂冷水机组排到冷却塔的热量要多",{"key":28,"text":353,"correct":26},"机组设置抽气装置的主要目的是提高系统真空度",{"key":31,"text":355,"correct":26},"因机组内部压力可能大于当地大气压力，所以系统必须采用压力容器",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":192,"analysis":34},881829,"实现均匀送风的措施，正确的做法是( )。",[360,362,364,365],{"key":20,"text":361,"correct":26},"可在孔口上设置不同的阻体，使孔口具有不同阻力(即改变流量系数μ)",{"key":24,"text":363,"correct":26},"改变送风管断面积，使两风口间的动压降等于两风口间阻力，风口上静压保持不变",{"key":28,"text":34,"correct":26},{"key":31,"text":34,"correct":22},{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":82,"analysis":34},881830,"体育馆、展览馆等大空间建筑内的通风、空气调节系统，当其风管按照防火分区设置，且设置防火阀时，下列风管材料的选择哪几项是正确的？( )",[370,372,374,376],{"key":20,"text":371,"correct":26},"不燃材料",{"key":24,"text":373,"correct":22},"可燃材料",{"key":28,"text":375,"correct":22},"燃烧物产毒性较小、烟密度等级不大于30的难燃材料",{"key":31,"text":377,"correct":26},"燃烧物产毒性较小、烟密度等级不大于25的难燃材料",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":130,"analysis":34},881831,"影响冷库围护结构热流量的因素是( )。",[382,384,386,388],{"key":20,"text":383,"correct":26},"保温层的导热系数和厚度",{"key":24,"text":385,"correct":22},"保温层的密度",{"key":28,"text":387,"correct":26},"保温层两侧的空气流速",{"key":31,"text":389,"correct":26},"保温层两侧的空气温度",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":230,"analysis":34},881832,"天津某商场的排风系统拟采用显热热回收装置，设计选用时，下列哪几项额定热回收效率是符合规定的？",[394,396,398,400],{"key":20,"text":395,"correct":22},"≥50%",{"key":24,"text":397,"correct":26},"≥60%",{"key":28,"text":399,"correct":26},"≥65%",{"key":31,"text":401,"correct":26},"≥70%",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":414,"analysis":34},881833,"下列关于水枪充实水柱长度的说法，正确的是( )。",[406,408,410,412],{"key":20,"text":407,"correct":26},"和室内最高着火点距地面高度有关",{"key":24,"text":409,"correct":26},"和水枪喷嘴距地面高度管径有关",{"key":28,"text":411,"correct":26},"和水枪的上倾角有关",{"key":31,"text":413,"correct":26},"充实水柱应达到室内最高着火点","ABCD",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":417,"answer":82,"analysis":34},881834,[418,420,422,424],{"key":20,"text":419,"correct":26},"玻璃的遮阳系数",{"key":24,"text":421,"correct":22},"窗帘的遮阳系数",{"key":28,"text":423,"correct":22},"活动内遮阳的遮阳系数",{"key":31,"text":425,"correct":26},"固定外遮阳和活动外遮阳的遮阳系数",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":230,"analysis":34},881835,"关于调压器的设计，下列说法正确的是( )。",[430,432,434,436],{"key":20,"text":431,"correct":22},"调压器的计算流量应按调压器所能承担的管网小时最大流量的1.1倍确定",{"key":24,"text":433,"correct":26},"调压器的压力差应根据调压器前燃气管道的最低设计压力与调压器后燃气管道的设计压力确定",{"key":28,"text":435,"correct":26},"调压装置应由过滤器、调压器、安全保护装置和两端的控制阀门组成",{"key":31,"text":437,"correct":26},"调压器前后应设压力表",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":230,"analysis":34},881836,"下列对集中供热热力网中的连通管的说法，正确的是( )。",[442,444,446,448],{"key":20,"text":443,"correct":22},"自热源向同一方向引出的长度超过5km的干线之间，宜设连通管线",{"key":24,"text":445,"correct":26},"当城市由两个或多个热源供热时，各热源热力网干线宜连通",{"key":28,"text":447,"correct":26},"连通管线应按热负荷较大干线切除故障段后，其余热负荷的70%计算",{"key":31,"text":449,"correct":26},"连通管应设在干线中部，同时可作为输配干线使用",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":192,"analysis":34},881837,"双级蒸气压缩式制冷循环的合理中间压力p，可以根据不同情况采用下列哪几项方法计算？( )",[454,455,456,458],{"key":20,"text":34,"correct":26},{"key":24,"text":34,"correct":26},{"key":28,"text":457,"correct":26},"按现有双级制冷压缩机的高、低压压缩机的容积比确定",{"key":31,"text":34,"correct":22},{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":192,"analysis":34},881838,"设计人员在选择空调冷水机组时应考虑的基本因素是( )。",[463,465,467,469],{"key":20,"text":464,"correct":26},"制冷剂应符合环保要求",{"key":24,"text":466,"correct":26},"COP应符合相关节能规范要求",{"key":28,"text":468,"correct":26},"调节性能应能满足使用要求",{"key":31,"text":470,"correct":22},"是否是进口品牌设备，以确保设备品质",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":60,"analysis":34},881839,"燃气管道选用和连接，错误的做法是下列哪几项？",[475,477,479,481],{"key":20,"text":476,"correct":26},"选用符合标准的焊接钢管时，低压、中压燃气管道宜采用普通管",{"key":24,"text":478,"correct":26},"燃气管道的引入管选用无缝钢管时，其壁厚不得小于3mm",{"key":28,"text":480,"correct":22},"室内燃气管道宜选用钢管，也可选用符合标准规定的其他管道",{"key":31,"text":482,"correct":26},"位于地下车库中的低压燃气管道，可采用螺纹连接",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":82,"analysis":34},881840,"关于吸附剂的活性，下列叙述正确的是( )。",[487,489,491,493],{"key":20,"text":488,"correct":26},"活性是对吸附剂吸附能力的描述",{"key":24,"text":490,"correct":22},"一种吸附剂对一种吸附质的静活性是不变的",{"key":28,"text":492,"correct":22},"静活性大于等于动活性",{"key":31,"text":494,"correct":26},"动活性与运行工况有关",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":60,"analysis":34},881841,"关于CFD技术，下列说法中错误的是( )。",[499,501,503,505],{"key":20,"text":500,"correct":26},"CFD计算精度不高，对实际工程设计的作用不大",{"key":24,"text":502,"correct":26},"采用CFD技术可以进行仿真模拟试验，因此可以取代模型试验",{"key":28,"text":504,"correct":22},"CFD技术可以提高室内气流组织设计的准确性",{"key":31,"text":506,"correct":26},"应用CFD技术可以提高暖通空调设计效率",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":60,"analysis":34},881842,"北京某办公楼的集中空调设计，下列哪些措施方案有利于夏季空调节能？",[511,513,515,517],{"key":20,"text":512,"correct":26},"装设排风全热回收装置",{"key":24,"text":514,"correct":26},"设置空调自动控制系统",{"key":28,"text":516,"correct":22},"采用溶液除湿空调方案",{"key":31,"text":518,"correct":26},"西、南向外窗外装遮阳窗",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":192,"analysis":34},881843,"下列哪几项说法不符合有关蒸汽采暖系统设计的规定？",[523,525,527,529],{"key":20,"text":524,"correct":26},"蒸汽采暖系统不应采用铸铁柱形散热器",{"key":24,"text":526,"correct":26},"高压蒸汽采暖系统最不利环路的供气管，其压力损失不大于起始压力的50%",{"key":28,"text":528,"correct":26},"高压蒸汽采暖系统，疏水器前的凝结水管不宜向上抬升",{"key":31,"text":530,"correct":22},"疏水器至回水箱之间的蒸汽凝结水管，应按汽水乳状进行计算",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":414,"analysis":34},881844,"在设置防烟分区时，应遵循的原则是( )。",[535,537,539,541],{"key":20,"text":536,"correct":26},"防烟分区不应跨越防火分区",{"key":24,"text":538,"correct":26},"防烟分区一般不跨越楼层，某些情况下，如1层面积过小，允许包括1个以上的楼层，但以不超过3层为宜",{"key":28,"text":540,"correct":26},"对有特殊用途的场所，如地下室、防烟楼梯间、消防电梯、避难层(间)等，应单独划分防烟分区",{"key":31,"text":542,"correct":26},"每个防烟分区的面积，对于高层民用建筑和其他建筑(含地下建筑和人防工程)，其建筑面积不宜大于500㎡",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":217,"analysis":34},881845,"战时为戊类物资库的防空地下室，下列哪几项是必须设置的通风设施？( )",[547,549,551,553],{"key":20,"text":548,"correct":26},"清洁通风",{"key":24,"text":550,"correct":26},"隔绝通风",{"key":28,"text":552,"correct":22},"滤毒通风",{"key":31,"text":554,"correct":22},"排烟通风",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":414,"analysis":34},881846,"地下室、半地下室或设备层内敷设人工煤气和天然气管道时，应符合的要求是( )。",[559,561,563,565],{"key":20,"text":560,"correct":26},"净高应小于2.2m",{"key":24,"text":562,"correct":26},"地下室、半地下室应有机械通风和事故排风设施",{"key":28,"text":564,"correct":26},"燃气管道应采用焊接或法兰连接",{"key":31,"text":566,"correct":26},"当燃气管道与其他管道一起敷设时，应敷设在其他管道的外侧",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":33,"analysis":34},881847,"采用变频风机时，选型应符合下述哪几项规定？",[571,573,575,577],{"key":20,"text":572,"correct":22},"风机的压力应在系统计算的压力损失上附加10%～150%",{"key":24,"text":574,"correct":26},"风机的压力以系统计算的总压力损失作为额定风压",{"key":28,"text":576,"correct":26},"风机电动机功率应在计算值上附加15%～20%",{"key":31,"text":578,"correct":22},"风机电动机功率应在计算值上附减15%-20%",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":217,"analysis":34},881848,"在冬季室外平均风速大于3.0m\u002Fs的地区，对于7～30层建筑，外窗的气密性可以是( )级水平。",[583,585,587,589],{"key":20,"text":584,"correct":26},"Ⅰ",{"key":24,"text":586,"correct":26},"Ⅱ",{"key":28,"text":588,"correct":22},"Ⅲ",{"key":31,"text":590,"correct":22},"Ⅳ",{"id":592,"libraryId":5,"type":593,"typeLabel":594,"stem":595,"options":596,"answer":28,"analysis":34},881849,1,"单选题","水蓄冷空调系统中，无隔板式温度分层型蓄冷水槽的绝热处理方案，正确的应是下列哪一项？",[597,599,601,603],{"key":20,"text":598,"correct":22},"水槽侧壁和底部绝热厚度均相同",{"key":24,"text":600,"correct":22},"水槽侧壁绝热厚度大于底部",{"key":28,"text":602,"correct":26},"水槽底部绝热厚度大于侧壁",{"key":31,"text":604,"correct":22},"水槽顶部和底部绝热厚度大于侧壁",{"id":606,"libraryId":5,"type":593,"typeLabel":594,"stem":607,"options":608,"answer":31,"analysis":34},881850,"净化空调系统送风管、回风管、排风管上风阀的设置应满足调节、关闭和防倒灌需要。止回阀常用于( )。",[609,611,613,615],{"key":20,"text":610,"correct":22},"送风管上",{"key":24,"text":612,"correct":22},"回风管上",{"key":28,"text":614,"correct":22},"新风管上",{"key":31,"text":616,"correct":26},"排风管上",[618,621,624,627,630,633],{"id":593,"name":619,"category":7,"favorite":620},"领导干部任职前廉政法规知识测试题",92,{"id":622,"name":623,"category":7,"favorite":593},595,"建筑结构与设备",{"id":625,"name":626,"category":7,"favorite":593},715,"招标采购专业知识与法律法规",{"id":628,"name":629,"category":7,"favorite":593},848,"市政方向-通用基础",{"id":631,"name":632,"category":7,"favorite":8},534,"BIM工程师",{"id":634,"name":632,"category":7,"favorite":8},535]