[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":621},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,4,50,2054,[13,34,48,60,72,85,97,110,123,137,150,162,174,186,199,211,219,231,243,255,267,279,291,303,315,327,339,351,363,375,387,399,411,423,434,447,459,469,481,493,501,513,525,537,549,561,573,585,597,609],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":32,"analysis":33},880001,2,"多选题","通风、净化空调系统的风管、附件与辅助材料的选择，下列哪项内容是正确的？( )",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","净化空调系统和排风系统风管应采用不燃材料",true,{"key":24,"text":25,"correct":22},"B","排烟系统的风管应采用不燃材料，其耐火极限应大于0.5h",{"key":27,"text":28,"correct":22},"C","附件、保温材料、消声材料和黏结剂等均采用不燃或难燃材料",{"key":30,"text":31,"correct":22},"D","排出腐蚀性气体的风管应采用耐腐蚀的难燃材料","ABCD","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":47,"analysis":33},880002,"当外网供回水管资用压差小于用户系统阻力时，外网与用户间可考虑下列哪些连接方式？( )",[38,41,43,45],{"key":20,"text":39,"correct":40},"直接连接",false,{"key":24,"text":42,"correct":22},"间接连接",{"key":27,"text":44,"correct":22},"直接连接，用户处设加压泵",{"key":30,"text":46,"correct":40},"加混水泵的直接连接","BC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":32,"analysis":33},880003,"用假定流速法设计通风管道系统时，假定合理流速需考虑的因素有( )。",[52,54,56,58],{"key":20,"text":53,"correct":22},"运行费用",{"key":24,"text":55,"correct":22},"造价",{"key":27,"text":57,"correct":22},"最高风速限制",{"key":30,"text":59,"correct":22},"最小风速限制",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":32,"analysis":33},880004,"寒冷地区设计采暖系统时，错误的做法应是下列哪几项？",[64,66,68,70],{"key":20,"text":65,"correct":22},"燃气红外线辐射器安装在地面上方2.9m处",{"key":24,"text":67,"correct":22},"暖风机安装在地面上方4.5m处",{"key":27,"text":69,"correct":22},"为了缓冲空气直接进入室内，在内斗设置散热器",{"key":30,"text":71,"correct":22},"低温热水地面辐射采暖系统采用65～55℃温水",{"id":73,"libraryId":5,"type":15,"typeLabel":16,"stem":74,"options":75,"answer":84,"analysis":33},880005,"某住宅小区设置有4个地下车库，面积分别为1号车库1500㎡、2号车库2030㎡、3号车库1960㎡和4号车库2080㎡，可采用自然排烟的地下车库应是下列哪几项？( )",[76,78,80,82],{"key":20,"text":77,"correct":22},"1号车库",{"key":24,"text":79,"correct":40},"2号车库",{"key":27,"text":81,"correct":22},"3号车库",{"key":30,"text":83,"correct":40},"4号车库","AC",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":47,"analysis":33},880006,"限制低温热水地面辐射供暖系统的热水供水温度，主要是出于( )的考虑。",[89,91,93,95],{"key":20,"text":90,"correct":40},"有利于保证地面温度的均匀",{"key":24,"text":92,"correct":22},"满足舒适要求",{"key":27,"text":94,"correct":22},"有利于延长塑料加热管的使用寿命",{"key":30,"text":96,"correct":40},"有利于保持较大的热媒流速，方便排除管内空气",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":109,"analysis":33},880007,"关于冷水(热泵)机组，正确的是( )。",[101,103,105,107],{"key":20,"text":102,"correct":22},"采用高温工况冷水机组作为冷源，可实现室内末端干工况运行",{"key":24,"text":104,"correct":22},"部分负荷性能系数与机组在25%，50%，75%和100%负荷时的性能系数有关",{"key":27,"text":106,"correct":40},"新机组进行测试时，蒸发器的污垢系数取0.018㎡·℃\u002FkW",{"key":30,"text":108,"correct":22},"测试噪声时，一般布置1～4个测点","ABD",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":122,"analysis":33},880008,"锅炉给水原水悬浮物的处理，应符合的要求有( )。",[114,116,118,120],{"key":20,"text":115,"correct":22},"悬浮物的含量大于5mg\u002FL的原水，在进入顺流再生固定床离子交换器前，应过滤",{"key":24,"text":117,"correct":22},"悬浮物的含量大于2mg\u002FL的原水，在进入逆流再生固定床或浮动床离子交换器前，应过滤",{"key":27,"text":119,"correct":22},"悬浮物的含量大于20mg\u002FL的原水或经石灰水处理后的水，应经混凝、澄清和过滤",{"key":30,"text":121,"correct":40},"悬浮物的含量大于6mg\u002FL的原水，在进入顺流再生固定床离子交换器前，应过滤","ABC",{"id":124,"libraryId":5,"type":125,"typeLabel":126,"stem":127,"options":128,"answer":24,"analysis":33},880009,1,"单选题","生活热水系统采用公称直径为DN32的管道，其流速宜( )。",[129,131,133,135],{"key":20,"text":130,"correct":40},"＜0.8m\u002Fs",{"key":24,"text":132,"correct":22},"≯1.0m\u002Fs",{"key":27,"text":134,"correct":40},"＜1.0m\u002Fs",{"key":30,"text":136,"correct":40},"≯1.2m\u002Fs",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":149,"analysis":33},880010,"有关除尘器的性能机理，下列哪几项是错误的？( )",[141,143,145,147],{"key":20,"text":142,"correct":40},"袋式除尘器中清洁的机织滤料除尘效率较低",{"key":24,"text":144,"correct":22},"袋式除尘器提高过滤风速，可以提高除尘效率",{"key":27,"text":146,"correct":22},"粉尘的分割粒径不能衡量不同旋风除尘器效率的优劣",{"key":30,"text":148,"correct":22},"金属钙、锌粉尘，因其粒径较细，可采用湿法除尘","BCD",{"id":151,"libraryId":5,"type":125,"typeLabel":126,"stem":152,"options":153,"answer":20,"analysis":33},880011,"处于海拔高度为1500m的地区，消防车内消防水泵进口中心线离地面高度为1.0m，消防水池最低水位低于取水口处消防车道的最大高度应是下列哪一项？",[154,156,158,160],{"key":20,"text":155,"correct":22},"3.6m",{"key":24,"text":157,"correct":40},"4.6m",{"key":27,"text":159,"correct":40},"4.7m",{"key":30,"text":161,"correct":40},"5.Om",{"id":163,"libraryId":5,"type":125,"typeLabel":126,"stem":164,"options":165,"answer":27,"analysis":33},880012,"空调房间工作区高度为2m，设侧送风口，风口下边距顶棚0.4m，射流实际射程要求为6m。为了满足侧送风气流组织要求，使送风射流不致波及工作区，则该空调房间的最小高度为( )。",[166,168,170,172],{"key":20,"text":167,"correct":40},"3.68m",{"key":24,"text":169,"correct":40},"3.35m",{"key":27,"text":171,"correct":22},"3.12m",{"key":30,"text":173,"correct":40},"3.86m",{"id":175,"libraryId":5,"type":125,"typeLabel":126,"stem":176,"options":177,"answer":30,"analysis":33},880013,"不属于离心式压缩机能量调节方法的是( )。",[178,180,182,184],{"key":20,"text":179,"correct":40},"调节叶轮进口导流叶片的角度",{"key":24,"text":181,"correct":40},"调节叶轮进口导流叶片的角度和压缩机的转速",{"key":27,"text":183,"correct":40},"调节叶轮进口导流叶片的角度和叶轮出口扩压器宽度",{"key":30,"text":185,"correct":22},"调节叶轮进口导流叶片的角度和容量调节滑阀位置",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":198,"analysis":33},880014,"某建筑的空调为一次泵水系统，夏季投入运行后发现，冷水泵的运行参数达到设计要求，且冷水机组并没有满负荷运行，但存在一些房间的实际温度高于设计值的现象。下列选项中，哪几项不是出现该现象的原因？",[190,192,194,196],{"key":20,"text":191,"correct":40},"温度过高的房间的末端设备设计冷量不够",{"key":24,"text":193,"correct":22},"冷水机组的制冷安装容量不够",{"key":27,"text":195,"correct":40},"末端设备没有采取自动控制措施(或自控失灵)",{"key":30,"text":197,"correct":22},"冷水泵的总水流量不足","BD",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":32,"analysis":33},880015,"关于除尘系统，下列说法正确的是( )。",[203,205,207,209],{"key":20,"text":204,"correct":22},"除尘系统的排风量，应按其全部吸风点同时工作计算",{"key":24,"text":206,"correct":22},"有非同时工作的吸风点时，系统的排风量可按同时工作的吸风点的排风量与非同时工作吸风点排风量的15%～20%之和确定",{"key":27,"text":208,"correct":22},"在间歇工作吸风点上装设与工艺设备联锁的阀门",{"key":30,"text":210,"correct":22},"吸风点的排风量，应按防止粉尘或有害气体逸至室内的原则通过计算确定",{"id":212,"libraryId":5,"type":125,"typeLabel":126,"stem":213,"options":214,"answer":30,"analysis":33},880016,"一栋商住楼，地下3层车库，地上30层，六层以上是住宅，一～五层为商场。该楼的一个消防防烟楼梯间及其合用前室分别加压送风(按一个出口计)，其加压送风机系统送风量应为下列何项?( )。",[215,216,217,218],{"key":20,"text":33,"correct":40},{"key":24,"text":33,"correct":40},{"key":27,"text":33,"correct":40},{"key":30,"text":33,"correct":22},{"id":220,"libraryId":5,"type":125,"typeLabel":126,"stem":221,"options":222,"answer":27,"analysis":33},880017,"下列选项中，在低温热水地面辐射采暖系统中对管材的技术要求是错误的是( )。",[223,225,227,229],{"key":20,"text":224,"correct":40},"埋设在填充层内的加热管不应有接头",{"key":24,"text":226,"correct":40},"埋地热水塑料加热管材应按使用条件为4级选择",{"key":27,"text":228,"correct":22},"塑料加热管的厚度不得小于1.8mm",{"key":30,"text":230,"correct":40},"铜管的下游管段不宜使用钢管",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":84,"analysis":33},880018,"空气源热泵机组在室外环境温度较低、相对湿度较高的情况下进行制热运行，会出现下列哪些情况？( )",[235,237,239,241],{"key":20,"text":236,"correct":22},"机组频繁除霜，不能保证室内空气温度要求",{"key":24,"text":238,"correct":40},"润滑油黏度太大，致使压缩机不能正常运行",{"key":27,"text":240,"correct":22},"压缩机排气温度过高，引起压缩机过热",{"key":30,"text":242,"correct":40},"制热效率基本不变",{"id":244,"libraryId":5,"type":125,"typeLabel":126,"stem":245,"options":246,"answer":30,"analysis":33},880019,"确定半即热式或快速式加热器的设计小时供热量的依据是( )。",[247,249,251,253],{"key":20,"text":248,"correct":40},"热水系统的设计小时耗热量",{"key":24,"text":250,"correct":40},"热水系统的设计小时耗热量减去加热器的贮热量",{"key":27,"text":252,"correct":40},"热水系统的设计小时耗热量减去加热器贮热量的一半",{"key":30,"text":254,"correct":22},"按照设计秒流量计算的热水系统耗热量",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":122,"analysis":33},880020,"对于自动控制用的两通电动调节阀，下列哪几项是正确的？( )",[259,261,263,265],{"key":20,"text":260,"correct":22},"控制空气湿度时，表冷器通常应配置理想特性为等百分比的阀门",{"key":24,"text":262,"correct":22},"变流量空调水系统供回水总管之间的压差控制阀应配置理想特性为等百分比的阀门",{"key":27,"text":264,"correct":22},"表冷器所配置的阀门口径与表冷器的设计阻力及设计流量有关",{"key":30,"text":266,"correct":40},"理想的等百分比特性的阀门含义是：阀门流量与阀门开度成正比",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":32,"analysis":33},880021,"单向流式气流组织的主要特点是( )。",[271,273,275,277],{"key":20,"text":272,"correct":22},"以平行气流为主方向气流，基本没有横向气流间的混掺",{"key":24,"text":274,"correct":22},"污染源所散发出的尘菌等污染物质在向室内扩散之前就被挤压排出室外",{"key":27,"text":276,"correct":22},"洁净气流本身对污染源会产生隔离作用，抑制了尘菌等污染物向房间的扩散",{"key":30,"text":278,"correct":22},"单向流式气流组织方式要求室内断面保持一定的风速，其折算的换气次数高达每小时数百次，为非单向流的10～20倍",{"id":280,"libraryId":5,"type":125,"typeLabel":126,"stem":281,"options":282,"answer":20,"analysis":33},880022,"关于严寒地区空调建筑热工设计，正确的是下列哪一项？",[283,285,287,289],{"key":20,"text":284,"correct":22},"外窗玻璃的遮阳系数越大越好",{"key":24,"text":286,"correct":40},"外窗玻璃的遮阳系数宜小于0.8",{"key":27,"text":288,"correct":40},"外窗玻璃的遮阳系数宜小于0.65",{"key":30,"text":290,"correct":40},"采用外遮阳措施",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":32,"analysis":33},880023,"某4层办公楼，冬季供暖系统围护结构耗热量计算，所包括的内容应是下列哪几项？( )",[295,297,299,301],{"key":20,"text":296,"correct":22},"围护结构基本耗热量",{"key":24,"text":298,"correct":22},"朝向修正",{"key":27,"text":300,"correct":22},"风力附加",{"key":30,"text":302,"correct":22},"外门修正",{"id":304,"libraryId":5,"type":125,"typeLabel":126,"stem":305,"options":306,"answer":27,"analysis":33},880024,"采用表面式换热器处理空气时，不能实现下列哪一项空气状态变化？( )",[307,309,311,313],{"key":20,"text":308,"correct":40},"减湿冷却",{"key":24,"text":310,"correct":40},"等湿加热",{"key":27,"text":312,"correct":22},"减湿加热",{"key":30,"text":314,"correct":40},"等湿冷却",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":122,"analysis":33},880025,"在某风机盘管加新风的空调系统设计中，将新风管与风机盘管回风箱相连，下列关于这种连接方式的表述中正确的是( )。",[319,321,323,325],{"key":20,"text":320,"correct":22},"由于新风与回风混合，因此新风的空气品质下降",{"key":24,"text":322,"correct":22},"有可能使回风过滤器处气流倒流，灰尘重新进入室内",{"key":27,"text":324,"correct":22},"尽管新风的新鲜程度下降，但人员需要的新风量不变",{"key":30,"text":326,"correct":40},"由于增加了新风流通量，使风机盘管需要的送风量增加",{"id":328,"libraryId":5,"type":125,"typeLabel":126,"stem":329,"options":330,"answer":20,"analysis":33},880026,"下列关于风机盘管加新风系统设计的说法中，不正确的是( )。",[331,333,335,337],{"key":20,"text":332,"correct":22},"新风管道竖向不能超过5层",{"key":24,"text":334,"correct":40},"新风系统规模应适当减小",{"key":27,"text":336,"correct":40},"新风宜直接送入空调区，不宜接在风机盘管回风箱上",{"key":30,"text":338,"correct":40},"宜对新风系统的风量进行调控",{"id":340,"libraryId":5,"type":125,"typeLabel":126,"stem":341,"options":342,"answer":27,"analysis":33},880027,"民用建筑的厨房、卫生间、盥洗室和浴室，宜设置( )进行全面换气。",[343,345,347,349],{"key":20,"text":344,"correct":40},"自然通风",{"key":24,"text":346,"correct":40},"机械通风",{"key":27,"text":348,"correct":22},"自然通风或机械通风",{"key":30,"text":350,"correct":40},"自然通风或机械排风",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":47,"analysis":33},880028,"下列关于建筑保温与空调能耗的说法中，正确的是( )。",[355,357,359,361],{"key":20,"text":356,"correct":40},"提高建筑围护结构保温性能，一定会使建筑夏季空调能耗减少",{"key":24,"text":358,"correct":22},"在确定建筑保温性能时还应考虑空调运行方式",{"key":27,"text":360,"correct":22},"对于北方地区，提高围护结构保温性能对减少夏季空调能耗的作用不大",{"key":30,"text":362,"correct":40},"为了减少建筑空调能耗，应尽可能提高南方地区的建筑外墙保温性能",{"id":364,"libraryId":5,"type":125,"typeLabel":126,"stem":365,"options":366,"answer":27,"analysis":33},880029,"关于R32制冷剂的性能表述，哪项是错误的?( )。",[367,369,371,373],{"key":20,"text":368,"correct":40},"R32的ODP值与R410A基本相等",{"key":24,"text":370,"correct":40},"R32的GWP值小于R410A",{"key":27,"text":372,"correct":22},"R32的工作压力小于R410A",{"key":30,"text":374,"correct":40},"R32具有低度可燃性",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":32,"analysis":33},880030,"计算热水供热管道保温层厚度时，环境温度取值正确的是( )。",[379,381,383,385],{"key":20,"text":380,"correct":22},"地上敷设时取供热介质按设计温度运行时的最高室外日平均温度",{"key":24,"text":382,"correct":22},"直埋敷设时取最冷月平均土壤自然温度",{"key":27,"text":384,"correct":22},"不通行管沟敷设时取最冷月平均土壤自然温度",{"key":30,"text":386,"correct":22},"通行管沟敷设时取40℃",{"id":388,"libraryId":5,"type":125,"typeLabel":126,"stem":389,"options":390,"answer":20,"analysis":33},880031,"冷库围护结构总热阻必须满足下列要求( )。",[391,393,395,397],{"key":20,"text":392,"correct":22},"大于计算出的最小热阻",{"key":24,"text":394,"correct":40},"小于计算出的最小热阻",{"key":27,"text":396,"correct":40},"热惰性指标小于等于4h的热阻",{"key":30,"text":398,"correct":40},"采用工艺性空调房间围护结构的总热阻",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":198,"analysis":33},880032,"冷热电三联供系统中，余热利用设备及容量选择，正确的是( )。",[403,405,407,409],{"key":20,"text":404,"correct":40},"应采用余热直接回收利用的方式",{"key":24,"text":406,"correct":22},"宜采用余热直接回收利用的方式",{"key":27,"text":408,"correct":40},"余热利用设备最低容量量不应高于发电机满负荷产生的余热量",{"key":30,"text":410,"correct":22},"余热利用设备最低容量不应低于发电机满负荷产生的余热量",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":47,"analysis":33},880033,"离心式压缩机运行过程发生“喘振”现象的原因，可能是下列哪几项？( )",[415,417,419,421],{"key":20,"text":416,"correct":40},"气体流量过大",{"key":24,"text":418,"correct":22},"气体流量过小",{"key":27,"text":420,"correct":22},"冷却水温过高",{"key":30,"text":422,"correct":40},"冷却水温过低",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":122,"analysis":33},880034,"室内温度高于室外温度的热车间，采用自然通风设计，排风窗孔温度的确定可采用的方法( )。",[427,429,430,432],{"key":20,"text":428,"correct":22},"气流组织良好的车间，可按与夏季通风室外计算温度的允许温差确定",{"key":24,"text":33,"correct":22},{"key":27,"text":431,"correct":22},"可采用有效散热系数计算",{"key":30,"text":433,"correct":40},"可采用估算法确定",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":446,"analysis":33},880035,"确定冬季供暖系统的热负荷应包含下列哪些因素？( )",[438,440,442,444],{"key":20,"text":439,"correct":22},"围护结构的耗热量",{"key":24,"text":441,"correct":40},"室内照明设备的散热量",{"key":27,"text":443,"correct":22},"外窗的辐射得热量",{"key":30,"text":445,"correct":22},"渗透冷风耗热量","ACD",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":122,"analysis":33},880036,"确定散热器数量时，应考虑下列哪些修正？( )",[451,453,455,457],{"key":20,"text":452,"correct":22},"连接方式",{"key":24,"text":454,"correct":22},"安装方式",{"key":27,"text":456,"correct":22},"进入散热器的流量",{"key":30,"text":458,"correct":40},"散热器的材质",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":109,"analysis":33},880037,"下列关于大中型饭店厨房通风系统设计的措施，错误的是( )。",[463,464,466,468],{"key":20,"text":33,"correct":22},{"key":24,"text":465,"correct":22},"补风量应为排风量的70%～80%",{"key":27,"text":467,"correct":40},"采用燃气灶具的密闭厨房应设CO报警器",{"key":30,"text":33,"correct":22},{"id":470,"libraryId":5,"type":125,"typeLabel":126,"stem":471,"options":472,"answer":20,"analysis":33},880038,"下列关于大气污染物排放标准的叙述，哪一项不符合现行国家标准的要求？( )",[473,475,477,479],{"key":20,"text":474,"correct":22},"污染物的排放浓度数值，是指温度293K、压力101325Pa状态下的干空气为基准的数值",{"key":24,"text":476,"correct":40},"通过排气筒排放的污染物，不得超过该污染物最高允许排放浓度",{"key":27,"text":478,"correct":40},"通过排气筒排放的污染物，不得超过该污染物按排气筒高度规定的最高允许排放速率",{"key":30,"text":480,"correct":40},"以无组织方式排放的污染物，必须按规定的监控点监测且不得超过相应的监控浓度限值",{"id":482,"libraryId":5,"type":125,"typeLabel":126,"stem":483,"options":484,"answer":24,"analysis":33},880039,"闭式水管系统中，管路总的压力损失包括( )。",[485,487,489,491],{"key":20,"text":486,"correct":40},"局部阻力和设备阻力",{"key":24,"text":488,"correct":22},"管道总阻力和设备阻力",{"key":27,"text":490,"correct":40},"管道总阻力和水提升高度",{"key":30,"text":492,"correct":40},"沿程阻力和设备阻力",{"id":494,"libraryId":5,"type":125,"typeLabel":126,"stem":495,"options":496,"answer":24,"analysis":33},880040,"利用温度梯度法计算排风温度tp时，散热量应( )为宜。",[497,498,499,500],{"key":20,"text":33,"correct":40},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":40},{"key":30,"text":33,"correct":40},{"id":502,"libraryId":5,"type":125,"typeLabel":126,"stem":503,"options":504,"answer":30,"analysis":33},880041,"某地埋管地源热泵机组冬季空调供热量为823kW，机组性能系数为4.58，蒸发器进出口水温度为15℃\u002F8℃，循环水泵释热量为18.7kW，该机组的地埋管换热系统从土壤中得到的最大吸热量和循环水量最接近下列哪一项？( )",[505,507,509,511],{"key":20,"text":506,"correct":40},"823kW，101t\u002Fh",{"key":24,"text":508,"correct":40},"662kW，81.3t\u002Fh",{"key":27,"text":510,"correct":40},"643.3kW，79t\u002Fh",{"key":30,"text":512,"correct":22},"624.6kW，79t\u002Fh",{"id":514,"libraryId":5,"type":125,"typeLabel":126,"stem":515,"options":516,"answer":24,"analysis":33},880042,"对住宅小区既有采暖系统节能改造的判定原则是下列哪一项？",[517,519,521,523],{"key":20,"text":518,"correct":40},"燃煤锅炉，管网供水温度低，并室温不能达到要求",{"key":24,"text":520,"correct":22},"锅炉年运行效率＜0.68，管网输送效率＜0.9，并室温不能达到要求",{"key":27,"text":522,"correct":40},"锅炉单台容量＜4.2MW",{"key":30,"text":524,"correct":40},"住宅小区供热面积＜10万㎡",{"id":526,"libraryId":5,"type":125,"typeLabel":126,"stem":527,"options":528,"answer":20,"analysis":33},880043,"对同一建筑而言，在水蓄冷和冰蓄冷空调系统中，下列哪一种说法是不正确的？( )",[529,531,533,535],{"key":20,"text":530,"correct":22},"水蓄冷系统的年制冷用电量高于冰蓄冷系统",{"key":24,"text":532,"correct":40},"水蓄冷系统需要的蓄冷装置体积大于冰蓄冷系统",{"key":27,"text":534,"correct":40},"水蓄冷系统的供水温度高于冰蓄冷系统",{"key":30,"text":536,"correct":40},"水蓄冷系统比冰蓄冷系统适合于已有消防水池的建筑",{"id":538,"libraryId":5,"type":125,"typeLabel":126,"stem":539,"options":540,"answer":30,"analysis":33},880044,"下列关于空调冷水机组夏季能耗的表述中，正确的是( )。",[541,543,545,547],{"key":20,"text":542,"correct":40},"冷水机组的能耗大于开机时间乘以冷水机组的额定功率",{"key":24,"text":544,"correct":40},"冷水机组的能耗等于开机时间乘以冷水机组的额定功率",{"key":27,"text":546,"correct":40},"冷水机组的能耗略小于开机时间乘以冷水机组的额定功率",{"key":30,"text":548,"correct":22},"冷水机组的能耗远小于开机时间乘以冷水机组的额定功率",{"id":550,"libraryId":5,"type":125,"typeLabel":126,"stem":551,"options":552,"answer":30,"analysis":33},880045,"公共建筑的空调冷热水管道绝热计算的基本原则，应是下列哪一项？",[553,555,557,559],{"key":20,"text":554,"correct":40},"每500m冷热水管道的平均温升不超过0.25℃",{"key":24,"text":556,"correct":40},"每500m冷热水管道的平均温降不超过0.30℃",{"key":27,"text":558,"correct":40},"超过500m空调管道的能量损失不大于5%",{"key":30,"text":560,"correct":22},"超过500m空调管道的能量损失不大于6%",{"id":562,"libraryId":5,"type":125,"typeLabel":126,"stem":563,"options":564,"answer":20,"analysis":33},880046,"某酒店建筑希望达到三星级绿色建筑标识，需要暖通空调专业协作至少在节能部分有3条优选项达标，下列哪条措施可能不符合要求？( )",[565,567,569,571],{"key":20,"text":566,"correct":22},"太阳能光伏板发电量占建筑总用电量的1%",{"key":24,"text":568,"correct":40},"开发地下60～90℃的地热水解决热水总需求的25%",{"key":27,"text":570,"correct":40},"地埋管地源热泵系统承担的供暖、空调负荷为建筑总负荷的50%",{"key":30,"text":572,"correct":40},"供暖空调能耗及照明能耗比参考建筑能耗下降20%",{"id":574,"libraryId":5,"type":125,"typeLabel":126,"stem":575,"options":576,"answer":27,"analysis":33},880047,"用以计算确定给水管道直径和调速泵组供水加压水泵的给水设计流量是指( )。",[577,579,581,583],{"key":20,"text":578,"correct":40},"最高日用水量",{"key":24,"text":580,"correct":40},"最大小时用水量",{"key":27,"text":582,"correct":22},"设计秒流量",{"key":30,"text":584,"correct":40},"平均小时用水量",{"id":586,"libraryId":5,"type":125,"typeLabel":126,"stem":587,"options":588,"answer":27,"analysis":33},880048,"北方某厂的厂区采用低压蒸汽采暖，设有凝结水回收管网。一新建1000㎡车间设计为暖风机热风采暖，系统调试时，发现暖风机供暖能力严重不足。但设计的暖风机选型均满足负荷计算和相关规范规定。下列分析的原因中，哪一项不会导致该问题发生？",[589,591,593,595],{"key":20,"text":590,"correct":40},"蒸汽干管或凝结水于管严重堵塞",{"key":24,"text":592,"correct":40},"热力人口低压蒸汽的供气量严重不足",{"key":27,"text":594,"correct":22},"每个暖风机环路的疏水回路总管上设置了疏水器，未在每一台暖风机的凝结水支管上设置疏水器",{"key":30,"text":596,"correct":40},"车间的凝结水总管的凝结水压力低于连接厂区凝结水管网处的凝结水压力",{"id":598,"libraryId":5,"type":125,"typeLabel":126,"stem":599,"options":600,"answer":30,"analysis":33},880049,"建筑高度为55m的普通办公楼，每层前室可开启外窗面积2.5㎡，防烟楼梯间无外窗。应采取的防排烟措施为( )。",[601,603,605,607],{"key":20,"text":602,"correct":40},"可以通过前室自然排烟，烟就不会进入楼梯间",{"key":24,"text":604,"correct":40},"防烟楼梯间加压送风，前室自然排烟",{"key":27,"text":606,"correct":40},"防烟楼梯间和前室分别加压送风",{"key":30,"text":608,"correct":22},"防烟楼梯间加压送风，前室不送风",{"id":610,"libraryId":5,"type":125,"typeLabel":126,"stem":611,"options":612,"answer":30,"analysis":33},880050,"穿越防火墙和变形缝的风管两侧各( )范围内应采用不燃材料及其胶粘剂。",[613,615,617,619],{"key":20,"text":614,"correct":40},"0.5m",{"key":24,"text":616,"correct":40},"1.0m",{"key":27,"text":618,"correct":40},"1.5m",{"key":30,"text":620,"correct":22},"2.0m",[622,625,628,631,634,637],{"id":125,"name":623,"category":7,"favorite":624},"领导干部任职前廉政法规知识测试题",92,{"id":626,"name":627,"category":7,"favorite":125},595,"建筑结构与设备",{"id":629,"name":630,"category":7,"favorite":125},715,"招标采购专业知识与法律法规",{"id":632,"name":633,"category":7,"favorite":125},848,"市政方向-通用基础",{"id":635,"name":636,"category":7,"favorite":8},534,"BIM工程师",{"id":638,"name":636,"category":7,"favorite":8},535]