[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-39":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":617},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,39,50,2054,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,222,234,245,257,269,281,293,301,313,324,336,346,358,367,379,391,403,415,427,442,455,468,481,494,506,518,531,544,556,569,581,593,605],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},881751,1,"单选题","在冰蓄冷空调系统中，对于同一建筑而言，下列哪一种说法是正确的？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","如果要降低空调冷水的供水温度，应优先采用并联系统",false,{"key":24,"text":25,"correct":26},"B","全负荷蓄冷系统的年用电量高于部分负荷蓄冷系统的年用电量",true,{"key":28,"text":29,"correct":22},"C","夜间不使用的建筑应设置基载制冷机",{"key":31,"text":32,"correct":22},"D","60%部分负荷蓄冷的意义是：蓄冷系统的瞬时最大供冷能力能满足空调设计负荷的60%","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},881752,"下列确定全面通风量方法的叙述中，( )是错误的。",[38,40,42,44],{"key":20,"text":39,"correct":22},"按某种有害物的发生量、该种有害物进风浓度和室内允许浓度计算所需通风量",{"key":24,"text":41,"correct":22},"室内同时产生多种有害物时，应按上述方法分别计算通风量",{"key":28,"text":43,"correct":22},"有害物发生量无法确定时，参照经验数据采用换气次数法计算通风量",{"key":31,"text":45,"correct":26},"取上述方法计算所得风量中的最大值作为设计通风量",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},881753,"大型商场设计全空气空调系统，下列哪一项作为主要节能措施是错误的？( )",[50,52,54,56],{"key":20,"text":51,"correct":22},"空气处理机组的风机采用变频调节",{"key":24,"text":53,"correct":22},"过渡季充分利用新风",{"key":28,"text":55,"correct":22},"合理匹配新、排风机，维持室内正压",{"key":31,"text":57,"correct":26},"减少新风量",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},881754,"某高层民用建筑，其地上、地下建筑的总高度为100m，则该建筑物的室内消火给水系统应采用( )。",[62,64,66,68],{"key":20,"text":63,"correct":26},"分区给水系统",{"key":24,"text":65,"correct":22},"不分区给水系统",{"key":28,"text":67,"correct":22},"减压稳压消火栓",{"key":31,"text":69,"correct":22},"设减压孔板的消火栓",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},881755,"某住宅毛细管网辐射供暖系统的设计，下列哪一项是正确的？( )",[74,76,78,80],{"key":20,"text":75,"correct":22},"供水温度35℃，回水温度20℃",{"key":24,"text":77,"correct":26},"卧室地板表面平均温度为28℃",{"key":28,"text":79,"correct":22},"系统工作压力0.8MPa",{"key":31,"text":81,"correct":22},"应优先考虑墙面埋置方式",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},881756,"一个冬夏季兼用的定流量空调水系统，夏季工况的流量是冬季工况的2倍，下列循环水泵设置方案中，哪一种方案的节能性最好？( )",[86,88,90,92],{"key":20,"text":87,"correct":22},"设置3台定速水泵，并联工作，两用一备，冬夏兼用，冬季运行1台",{"key":24,"text":89,"correct":22},"设置2台变频水泵串联工作，冬夏兼用，冬季低速运行",{"key":28,"text":91,"correct":22},"设置2台变频水泵并联工作，一用一备，冬夏兼用，冬季低速运行",{"key":31,"text":93,"correct":26},"冬季和夏季循环泵分开设置，夏季工况设置3台定速水泵，并联工作，两用一备，冬季工况设置2台定速水泵，并联工作，一用一备",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},881757,"热泵机组的说法，错误的应为下列哪一项？",[98,100,102,104],{"key":20,"text":99,"correct":22},"地埋管热泵机组的地埋管换热系统宜采用变流量设计",{"key":24,"text":101,"correct":22},"地埋管热泵机组的地埋管换热系统，夏季是向土壤释热",{"key":28,"text":103,"correct":22},"热泵热水机所供应的热水温度越高，机组制热能效比就越低",{"key":31,"text":105,"correct":26},"热泵机组空调系统的节能效果与效益大小仅取决于低区气候特性的因素",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},881758,"5级洁净室风管严密性检验的要求，应是下列哪一项？( )",[110,112,114,116],{"key":20,"text":111,"correct":22},"漏光法",{"key":24,"text":113,"correct":22},"漏风量测试，抽检率20%",{"key":28,"text":115,"correct":22},"漏风量测试，不得少于1个系统",{"key":31,"text":117,"correct":26},"按高压系统进行漏风量测试，全数进行",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},881759,"( )在很大程度上影响除尘器的性能，是袋式除尘器分类的主要依据。",[122,124,126,128],{"key":20,"text":123,"correct":22},"通过流速",{"key":24,"text":125,"correct":22},"过滤粒径",{"key":28,"text":127,"correct":26},"清灰方式",{"key":31,"text":129,"correct":22},"滤料型式",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},881760,"制冷系统的制冷量( )。",[134,136,138,140],{"key":20,"text":135,"correct":22},"随冷凝温度的降低而降低",{"key":24,"text":137,"correct":26},"随蒸发温度的升高而升高",{"key":28,"text":139,"correct":22},"随过冷温度的升高而升高",{"key":31,"text":141,"correct":22},"随过热温度的升高而降低",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},881761,"下列关于改善蒸气压缩式制冷循环性能的主要措施，说法正确的是( )。",[146,148,150,152],{"key":20,"text":147,"correct":22},"采用回热循环和多级压缩",{"key":24,"text":149,"correct":26},"采用膨胀阀前再冷却制冷剂和多级压缩",{"key":28,"text":151,"correct":22},"加大蒸发器和加大冷凝器",{"key":31,"text":153,"correct":22},"加大蒸发器与加大冷凝器，采用膨胀阀前再冷却制冷剂",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},881762,"在制冷系统的联锁控制中，系统各设备启动的先后顺序排列正确的是( )。",[158,160,162,164],{"key":20,"text":159,"correct":26},"冷却塔、冷却水泵、冷水泵、制冷机组",{"key":24,"text":161,"correct":22},"冷却水泵、制冷机组、冷却塔、冷水泵",{"key":28,"text":163,"correct":22},"冷却塔、冷却水泵、制冷机组、冷水泵",{"key":31,"text":165,"correct":22},"制冷机组、冷水泵、冷却水泵、冷却塔",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":31,"analysis":33},881763,"高压蒸汽供暖系统水力计算时，正确的做法是( )。",[170,172,174,176],{"key":20,"text":171,"correct":22},"采用当量阻力法计算",{"key":24,"text":173,"correct":22},"管道的管径根据热负荷查表确定",{"key":28,"text":175,"correct":22},"管内流速不受限制",{"key":31,"text":177,"correct":26},"高压蒸汽最不利环路供汽管的压力损失不应大于起始压力的25%",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":31,"analysis":33},881764,"在夏热冬冷地区一栋办公建筑围护结构热工设计时，下列选项中不能满足要求的是( )。",[182,184,186,188],{"key":20,"text":183,"correct":22},"外墙传热系数为0.95W\u002F(㎡2·K)",{"key":24,"text":185,"correct":22},"屋顶传热系数为0.65W\u002F(㎡·K)",{"key":28,"text":187,"correct":22},"空调房间与非空调房间之间隔墙传热系数为2.0W\u002F(㎡·K)",{"key":31,"text":189,"correct":26},"窗墙面积比为0.45时，南向外窗玻璃的遮阳系数为0.5(无外遮阳)",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":33},881765,"一般性建筑屋面雨水重力流排水系统与溢流设施的“设计重现期”应取不小于( )。",[194,196,198,200],{"key":20,"text":195,"correct":22},"1～3年",{"key":24,"text":197,"correct":22},"2～5年",{"key":28,"text":199,"correct":26},"10年",{"key":31,"text":201,"correct":22},"50年",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":28,"analysis":33},881766,"饱和蒸汽的临界压力比为0.577，入口工作压力为1.0MPa，用汽设备工作压力为0.2MPa，需要配置减压阀。当减压阀的形式、特性和口径根据要求选定以后，影响减压阀流量的因素是( )。",[206,208,210,212],{"key":20,"text":207,"correct":22},"减压阀人口压力和减压比",{"key":24,"text":209,"correct":22},"减压阀出口压力和减压比",{"key":28,"text":211,"correct":26},"减压阀的入口压力",{"key":31,"text":213,"correct":22},"阀孔的流量系数",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},881767,"洁净度等级为6级的非单向流洁净室，换气次数按( )计算。",[218,219,220,221],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":31,"analysis":33},881768,"下列哪个低压蒸汽供暖系统的立管管径必须加大？( )",[226,228,230,232],{"key":20,"text":227,"correct":22},"双管上供下回式",{"key":24,"text":229,"correct":22},"双管下供上回式",{"key":28,"text":231,"correct":22},"单管上供下回式",{"key":31,"text":233,"correct":26},"单管下供下回式",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":24,"analysis":33},881769,"关于疏水器的选用下列哪一项是错误的？",[238,240,242,244],{"key":20,"text":239,"correct":22},"疏水器设计排水量应该大于理论排水量",{"key":24,"text":241,"correct":26},"减压装置的疏水器宜采用恒温型疏水器",{"key":28,"text":243,"correct":22},"蒸汽管道末端可采用热动力式疏水器",{"key":31,"text":33,"correct":22},{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":20,"analysis":33},881770,"新风机组实行集中监控，其中送风温度、冷却盘管水量调节、送风机运行状态和送风机启停控制的信号类型，依次为下列哪一项？( )",[249,251,253,255],{"key":20,"text":250,"correct":26},"AI，AO，DI，DO",{"key":24,"text":252,"correct":22},"DI，DO，AI，AO",{"key":28,"text":254,"correct":22},"AI，DO，DI，AO",{"key":31,"text":256,"correct":22},"AI，DI，AO，DO",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":24,"analysis":33},881771,"氨压缩机选型时，同一机房内选配的压缩机型号不宜超过( )系列。",[261,263,265,267],{"key":20,"text":262,"correct":22},"一种",{"key":24,"text":264,"correct":26},"两种",{"key":28,"text":266,"correct":22},"三种",{"key":31,"text":268,"correct":22},"四种",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":28,"analysis":33},881772,"当电制冷冷水机组十冷却塔系统运行出现不能制冷现象时，首先可以排除的原因是哪一项？",[273,275,277,279],{"key":20,"text":274,"correct":22},"制冷剂不足",{"key":24,"text":276,"correct":22},"室外空气干球温度过高",{"key":28,"text":278,"correct":26},"压缩机压缩比下降",{"key":31,"text":280,"correct":22},"室外空气湿球温度过高",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":28,"analysis":33},881773,"无论选择弹簧隔振器还是选择橡胶隔振器，下列哪一项要求是错误的？( )",[285,287,289,291],{"key":20,"text":286,"correct":22},"隔振器与基础之间宜设置一定厚度的弹性隔振垫",{"key":24,"text":288,"correct":22},"隔振器承受的荷载，不应超过容许工作荷载",{"key":28,"text":290,"correct":26},"应计入环境温度对隔振器压缩变形量的影响",{"key":31,"text":292,"correct":22},"设备的运转频率与隔振器垂直方向的固有频率之比，宜为4～5",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":20,"analysis":33},881774,"计算换热器面积时，加热与被加热流体间的对数平均温差( )。",[297,298,299,300],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":31,"analysis":33},881775,"《洁净规范》洁净度等级的级别中被考虑的粒径范围为( )。",[305,307,309,311],{"key":20,"text":306,"correct":22},"0.5μm，5μm",{"key":24,"text":308,"correct":22},"0.1μm，0.2μm，0.3μm，0.5μm，5μm",{"key":28,"text":310,"correct":22},"0.1μm，0.3μm，0.5μm，5μm",{"key":31,"text":312,"correct":26},"0.1μm，0.2μm，0.3μm，0.5μm，1.0μm，5μm",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":315,"answer":28,"analysis":33},881776,[316,318,320,322],{"key":20,"text":317,"correct":22},"67dB",{"key":24,"text":319,"correct":22},"75dB",{"key":28,"text":321,"correct":26},"78dB",{"key":31,"text":323,"correct":22},"85dB",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":31,"analysis":33},881777,"高层民用建筑长度内走道应设置排烟设施的要求对于( )是正确的。",[328,330,332,334],{"key":20,"text":329,"correct":22},"一类高层建筑长度超过30m的内走道",{"key":24,"text":331,"correct":22},"二类高层建筑长度超过30m的内走道",{"key":28,"text":333,"correct":22},"高层建筑长度超过20m的内走道",{"key":31,"text":335,"correct":26},"一类建筑和建筑高度超过32m的二类建筑长度超过20m的内走道",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":31,"analysis":33},881778,"利用天窗排风的工业建筑，下列哪个场所不采用避风天窗是允许的？( )",[340,342,343,344],{"key":20,"text":341,"correct":22},"不允许气流倒灌的车间",{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":345,"correct":26},"夏季室外平均风速小于或等于1m\u002Fs的地区",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":31,"analysis":33},881779,"夏热冬冷地区某城市的不同建筑采用多联式空调(热泵)机组，说法正确的应为下列何项?( )。",[350,352,354,356],{"key":20,"text":351,"correct":22},"同一型号、规格的多联式空调(热泵)机组应用于办公楼比应用于商场的实际能效比更高",{"key":24,"text":353,"correct":22},"同一型号、规格的多联式空调(热泵)机组应用于商场比应用于办公楼的实际能效比更高",{"key":28,"text":355,"correct":22},"多联式空调(热泵)机组需要设置专门的运行管理人员",{"key":31,"text":357,"correct":26},"多联式空调(热泵)机组可实现分室计量",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},881780,"地下停车库的通风系统节能运行，宜根据车库内的某种气体浓度进行自动运行控制，该种气体应是下列哪一项？",[362,363,365,366],{"key":20,"text":33,"correct":22},{"key":24,"text":364,"correct":26},"CO",{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":24,"analysis":33},881781,"为防止可燃粉尘、纤维与采暖散热器接触引起自燃，应控制热媒温度，下列哪一项是正确的？",[371,373,375,377],{"key":20,"text":372,"correct":22},"0.2MPa蒸汽",{"key":24,"text":374,"correct":26},"供回水温度95\u002F70℃",{"key":28,"text":376,"correct":22},"0.3MPa蒸汽",{"key":31,"text":378,"correct":22},"供回水温度130\u002F70℃",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":28,"analysis":33},881782,"下列哪一项级别的洁净室可设计散热器采暖系统？",[383,385,387,389],{"key":20,"text":384,"correct":22},"5级以上",{"key":24,"text":386,"correct":22},"6～7级",{"key":28,"text":388,"correct":26},"8～9级",{"key":31,"text":390,"correct":22},"都不是",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":28,"analysis":33},881783,"单级压缩式制冷回热循环可采用的制冷工质的表述，正确的应是下列哪一项？( )",[395,397,399,401],{"key":20,"text":396,"correct":22},"R22和R717都可采用回热制冷循环",{"key":24,"text":398,"correct":22},"R22和R717都不可采用回热制冷循环",{"key":28,"text":400,"correct":26},"R22和R502都可采用回热制冷循环",{"key":31,"text":402,"correct":22},"R22和R502都不可采用回热制冷循环",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":20,"analysis":33},881784,"关于空调设备能效比的说法中，正确的是( )。",[407,409,411,413],{"key":20,"text":408,"correct":26},"风冷空调机组的额定制冷量增大，其COP可能会减小",{"key":24,"text":410,"correct":22},"水冷冷水机组的额定制冷量越大，其COP越高，因此减少冷水机组台数可以达到节能效果",{"key":28,"text":412,"correct":22},"室外气温降低，会使冷水机组偏离额定工况，因此会使其COP下降",{"key":31,"text":414,"correct":22},"空调负荷率越低，冷水机组的COP越低",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":31,"analysis":33},881785,"喷水室根据喷水温度的不同，可以实现空气状态的不同处理过程，其过程处理数应是下列哪一项？( )",[419,421,423,425],{"key":20,"text":420,"correct":22},"实现4种不同过程",{"key":24,"text":422,"correct":22},"实现5种不同过程",{"key":28,"text":424,"correct":22},"实现6种不同过程",{"key":31,"text":426,"correct":26},"实现7种不同过程",{"id":428,"libraryId":5,"type":429,"typeLabel":430,"stem":431,"options":432,"answer":441,"analysis":33},881786,2,"多选题","影响墙体热工性能的参数，下列哪几项是正确的？( )",[433,435,437,439],{"key":20,"text":434,"correct":26},"各材料层及内外表面热阻",{"key":24,"text":436,"correct":26},"各层材料蓄热系数",{"key":28,"text":438,"correct":22},"由内向外，各材料层的内表面蓄热系数、空气夹层内表面蓄热系数",{"key":31,"text":440,"correct":22},"由内向外，各材料层的外表面蓄热系数、空气夹层外表面蓄热系数","AB",{"id":443,"libraryId":5,"type":429,"typeLabel":430,"stem":444,"options":445,"answer":454,"analysis":33},881787,"围护结构隔热材料的厚度与( )因素有关。",[446,448,450,452],{"key":20,"text":447,"correct":22},"隔热材料内外温度",{"key":24,"text":449,"correct":26},"隔热材料的厚度",{"key":28,"text":451,"correct":26},"围护结构内、外表面传热系数",{"key":31,"text":453,"correct":26},"隔热材料的热导率","BCD",{"id":456,"libraryId":5,"type":429,"typeLabel":430,"stem":457,"options":458,"answer":467,"analysis":33},881788,"围护结构最小传热阻是根据( )来确定。",[459,461,463,465],{"key":20,"text":460,"correct":22},"室外供暖计算温度",{"key":24,"text":462,"correct":26},"冬季围护结构室外计算温度",{"key":28,"text":464,"correct":26},"室内温度与围护结构内表面温度的允许温差",{"key":31,"text":466,"correct":22},"围护结构的蒸汽渗透阻","BC",{"id":469,"libraryId":5,"type":429,"typeLabel":430,"stem":470,"options":471,"answer":480,"analysis":33},881789,"选择离心式制冷压缩机的供电方式时，下列哪些表述是正确的？( )",[472,474,476,478],{"key":20,"text":473,"correct":26},"额定电压可为380V，6kV，10kV",{"key":24,"text":475,"correct":22},"采用高压供电会增加投资",{"key":28,"text":477,"correct":26},"采用高压供电会减少维护费用",{"key":31,"text":479,"correct":26},"在供电可靠和能保证安全的前提下，大型离心机制冷站宜采用高压供电方式","ACD",{"id":482,"libraryId":5,"type":429,"typeLabel":430,"stem":483,"options":484,"answer":493,"analysis":33},881790,"多层建筑厨房排油烟管道上所用的防火阀动作温度不应是( )。",[485,487,489,491],{"key":20,"text":486,"correct":26},"70℃",{"key":24,"text":488,"correct":26},"80℃",{"key":28,"text":490,"correct":22},"150℃",{"key":31,"text":492,"correct":26},"280℃","ABD",{"id":495,"libraryId":5,"type":429,"typeLabel":430,"stem":496,"options":497,"answer":467,"analysis":33},881791,"下列对消火栓栓口压力的说法，正确的是( )。",[498,500,502,504],{"key":20,"text":499,"correct":22},"消火栓栓口最高静水压力不应超过0.7MPa",{"key":24,"text":501,"correct":26},"消火栓栓口出水压力不应超过0.5MPa",{"key":28,"text":503,"correct":26},"消火栓栓口最高静水压力不应超过0.8MPa",{"key":31,"text":505,"correct":22},"消火栓栓口出水压力不应超过0.4MPa",{"id":507,"libraryId":5,"type":429,"typeLabel":430,"stem":508,"options":509,"answer":467,"analysis":33},881792,"计算工业厂房的自然通风，确定厂房上部窗孔排风温度时，哪几项是错误的？",[510,512,514,516],{"key":20,"text":511,"correct":22},"对于某些特定的车间，可按排风温度与夏季通风室外计算温度的允许温差确定",{"key":24,"text":513,"correct":26},"对于厂房高度小于15m，室内散热量比较均匀，可取室内空气的平均温度",{"key":28,"text":515,"correct":26},"对于厂房高度大于15m，室内散热量比较均匀，且散热量不大于116W\u002Fmz，可按温度梯度法计算排风温度",{"key":31,"text":517,"correct":22},"有强烈热源的车间，可按有效散热系数法计算确定",{"id":519,"libraryId":5,"type":429,"typeLabel":430,"stem":520,"options":521,"answer":530,"analysis":33},881793,"关于大气尘的说法，正确的是( )。",[522,524,526,528],{"key":20,"text":523,"correct":26},"大气中的悬浮微粒习惯称大气尘",{"key":24,"text":525,"correct":26},"大气尘是既包括固态微粒也包含液态微粒的多分散气溶胶",{"key":28,"text":527,"correct":26},"大气尘专指大气中粒径小于10μm的悬浮微粒",{"key":31,"text":529,"correct":26},"大气尘在环境保护领域被称作飘尘","ABCD",{"id":532,"libraryId":5,"type":429,"typeLabel":430,"stem":533,"options":534,"answer":543,"analysis":33},881794,"某大空间展览中心进行供暖设计，哪些是不合理的供暖方式?( )。",[535,537,539,541],{"key":20,"text":536,"correct":22},"红外线辐射供暖，安装标高为7.5m",{"key":24,"text":538,"correct":26},"燃气供暖，安装标高为7.5m",{"key":28,"text":540,"correct":22},"组合式空调机组进行热风供暖，旋流送风口安装在6.5m处的吊顶上",{"key":31,"text":542,"correct":26},"风机盘管加新风系统进行冬季供暖，将其安装在6.5m处的吊顶内","BD",{"id":545,"libraryId":5,"type":429,"typeLabel":430,"stem":546,"options":547,"answer":441,"analysis":33},881795,"机械加压送风机的全压，除克服最不利环路管道阻力外，尚有余压。其压力值应符合( )。",[548,550,552,554],{"key":20,"text":549,"correct":26},"防烟楼梯间为50Pa",{"key":24,"text":551,"correct":26},"前室、合用前室25Pa",{"key":28,"text":553,"correct":22},"避难层40Pa",{"key":31,"text":555,"correct":22},"封闭间25Pa",{"id":557,"libraryId":5,"type":429,"typeLabel":430,"stem":558,"options":559,"answer":568,"analysis":33},881796,"疏水器后凝水提升高度与下列哪些因素有关？( )",[560,562,564,566],{"key":20,"text":561,"correct":26},"疏水器后压力",{"key":24,"text":563,"correct":26},"回水箱内压力",{"key":28,"text":565,"correct":26},"疏水器后系统的压力损失",{"key":31,"text":567,"correct":22},"疏水器的排水系数","ABC",{"id":570,"libraryId":5,"type":429,"typeLabel":430,"stem":571,"options":572,"answer":467,"analysis":33},881797,"根据消防设计规范对通风、空调系统的风管上应设置防火阀的要求，下列哪几项是正确的？( )",[573,575,577,579],{"key":20,"text":574,"correct":22},"发电机房储油间的排风管穿越储油间的隔墙处，应设置280℃的排烟防火阀",{"key":24,"text":576,"correct":26},"发电机房储油间的排风管穿越储油间的隔墙处，应设置70℃的防火阀",{"key":28,"text":578,"correct":26},"连接排风竖井的卫生间排风支管上，应设置70℃的防火阀",{"key":31,"text":580,"correct":22},"连接戊类库房的排风支管上，应设置70℃的防火阀",{"id":582,"libraryId":5,"type":429,"typeLabel":430,"stem":583,"options":584,"answer":493,"analysis":33},881798,"理论制冷循环的节流损失与( )有关。",[585,587,589,591],{"key":20,"text":586,"correct":26},"冷凝温度与蒸发温度差",{"key":24,"text":588,"correct":26},"制冷剂物理性质",{"key":28,"text":590,"correct":22},"压缩机的吸气过热度",{"key":31,"text":592,"correct":26},"冷凝压力",{"id":594,"libraryId":5,"type":429,"typeLabel":430,"stem":595,"options":596,"answer":530,"analysis":33},881799,"有关公共建筑应设机械防烟设施的规定，正确的应是下列哪几项？( )",[597,599,601,603],{"key":20,"text":598,"correct":26},"不具备自然排烟条件的消防电梯间合用前室",{"key":24,"text":600,"correct":26},"设置自然排烟设施的防烟楼梯间，其不具备自然排烟条件的前室",{"key":28,"text":602,"correct":26},"不具备自然排烟条件的消防电梯间前室",{"key":31,"text":604,"correct":26},"不具备自然排烟条件的防烟楼梯间",{"id":606,"libraryId":5,"type":429,"typeLabel":430,"stem":607,"options":608,"answer":441,"analysis":33},881800,"下列哪些类型的供暖建筑宜采用Ⅰ类地面？( )",[609,611,613,615],{"key":20,"text":610,"correct":26},"幼儿园",{"key":24,"text":612,"correct":26},"疗养院",{"key":28,"text":614,"correct":22},"学校",{"key":31,"text":616,"correct":22},"办公楼",[618,621,624,627,630,633],{"id":15,"name":619,"category":7,"favorite":620},"领导干部任职前廉政法规知识测试题",92,{"id":622,"name":623,"category":7,"favorite":15},595,"建筑结构与设备",{"id":625,"name":626,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":628,"name":629,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":631,"name":632,"category":7,"favorite":8},534,"BIM工程师",{"id":634,"name":632,"category":7,"favorite":8},535]