[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-569-38":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":613},{"id":5,"name":6,"category":7,"favorite":8},569,"专业知识（暖通空调专业）","建筑工程",0,38,50,2054,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,249,261,273,284,296,308,320,332,344,356,368,380,392,404,416,428,435,447,459,470,482,494,506,518,530,542,554,566,578,590,602],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},881701,1,"单选题","空气洁净度所要控制的对象是( )。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","空气中最大控制微粒直径",false,{"key":24,"text":25,"correct":22},"B","空气中的微粒数量",{"key":27,"text":28,"correct":29},"C","空气中最小控制微粒直径和微粒数量",true,{"key":31,"text":32,"correct":22},"D","空气中最小控制微粒直径","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},881702,"某3层建筑采用重力循环供暖系统，其底层散热器比供暖热源高0.1m，应采用下列哪种系统？( )",[38,40,42,44],{"key":20,"text":39,"correct":22},"双管上供下回",{"key":24,"text":41,"correct":22},"双管下供上回",{"key":27,"text":43,"correct":29},"单管上供下回",{"key":31,"text":45,"correct":22},"单管下供上回",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},881703,"关于组合式空调机组的设计原则中，哪一项是正确的？( )",[50,52,54,56],{"key":20,"text":51,"correct":22},"按产品样本中的制冷量和制热量额定值选取组合式空调机组",{"key":24,"text":53,"correct":22},"高压喷雾加湿器出口紧接着设置中效过滤器",{"key":27,"text":55,"correct":29},"有温湿度控制要求的工艺性空调，空气加热器应设置在表冷器的出口",{"key":31,"text":57,"correct":22},"消声器应尽量由组合式空调机组配带，以避免在风管上设置消声器",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},881704,"蒸气压缩循环(热泵)机组制热名义工况时的参数，下列哪一项不符合国家标准？( )",[62,64,66,68],{"key":20,"text":63,"correct":22},"使用侧制热，进出口水温为40℃\u002F45℃",{"key":24,"text":65,"correct":29},"热源侧水冷式(制热)，进出口水温为12℃\u002F7℃",{"key":27,"text":67,"correct":22},"热源侧风冷式(制热)，空气干球温度为7℃",{"key":31,"text":69,"correct":22},"热源侧风冷式(制热)，空气湿球温度为6℃",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},881705,"燃气红外线全面辐射供暖系统沿四周外墙、外门处布置的辐射器散热量，不宜小于总热负荷的( )。",[74,76,78,80],{"key":20,"text":75,"correct":22},"50%",{"key":24,"text":77,"correct":29},"60%",{"key":27,"text":79,"correct":22},"70%",{"key":31,"text":81,"correct":22},"80%",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},881706,"在溴化锂一水吸收式工质对中，水是( )。",[86,88,90,92],{"key":20,"text":87,"correct":22},"吸收剂",{"key":24,"text":89,"correct":29},"制冷剂",{"key":27,"text":91,"correct":22},"载冷剂",{"key":31,"text":93,"correct":22},"冷却剂",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},881707,"对制冷剂直接膨胀式空气冷却器的蒸发温度，下列说法正确的是( )。",[98,100,102,104],{"key":20,"text":99,"correct":22},"应比空气出口温度至少低5℃",{"key":24,"text":101,"correct":22},"应比空气出口温度至少低3℃",{"key":27,"text":103,"correct":22},"应比空气出口温度至少低2℃",{"key":31,"text":105,"correct":29},"应比空气出口温度至少低3.5℃",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},881708,"关于复合通风系统，下列描述中哪项是错误的？( )",[110,112,114,116],{"key":20,"text":111,"correct":29},"复合通风系统是自然通风与机械通风交替运行的通风方式",{"key":24,"text":113,"correct":22},"自然通风量不宜低于联合运行通风量的30%",{"key":27,"text":115,"correct":22},"运行时应优先使用自然通风",{"key":31,"text":117,"correct":22},"适用于大空间建筑",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":27,"analysis":33},881709,"建筑高度为55m的商住楼，防烟楼梯间每层各有可开启外窗面积2.5㎡，合用前室无外窗。应采取的防排烟措施为( )。",[122,124,126,128],{"key":20,"text":123,"correct":22},"可以通过防烟楼梯间自然排烟，合用前室不需排烟",{"key":24,"text":125,"correct":22},"防烟楼梯间自然排烟，合用前室加压送风",{"key":27,"text":127,"correct":29},"防烟楼梯间和合用前室宜分别加压送风",{"key":31,"text":129,"correct":22},"防烟楼梯间加压送风，合用前室不送风",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},881710,"冬季围护结构室外计算温度与下列哪个因素无关？( )",[134,136,138,140],{"key":20,"text":135,"correct":22},"累年最低日平均温度",{"key":24,"text":137,"correct":22},"供暖室外计算温度",{"key":27,"text":139,"correct":22},"围护结构外层材料导热系数",{"key":31,"text":141,"correct":29},"围护结构外层材料太阳辐射吸收率",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":27,"analysis":33},881711,"对于两级蒸气压缩制冷循环，高、低压级压缩机的输气量( )。",[146,148,150,152],{"key":20,"text":147,"correct":22},"相等",{"key":24,"text":149,"correct":22},"前者大于后者",{"key":27,"text":151,"correct":29},"前者小于后者",{"key":31,"text":153,"correct":22},"不能确定",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},881712,"如某噪声听起来与声压级85d B、频率1000Hz的基准声音同样响，则该噪声的响度级就是( )phon。",[158,160,162,164],{"key":20,"text":159,"correct":22},"1000",{"key":24,"text":161,"correct":29},"85",{"key":27,"text":163,"correct":22},"1085",{"key":31,"text":165,"correct":22},"500",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},881713,"空调用冷水机组的冷却水进水温度不宜超过( )。",[170,172,174,176],{"key":20,"text":171,"correct":22},"34℃",{"key":24,"text":173,"correct":29},"33℃",{"key":27,"text":175,"correct":22},"35℃",{"key":31,"text":177,"correct":22},"40℃",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},881714,"水蓄冷系统中，蓄冷水温不宜低于( )。",[182,184,186,188],{"key":20,"text":183,"correct":22},"7℃",{"key":24,"text":185,"correct":29},"4℃",{"key":27,"text":187,"correct":22},"2℃",{"key":31,"text":189,"correct":22},"0℃",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},881715,"闭式热水供热系统补水装置的流量，不应小于供热系统循环水塞的( )。",[194,196,198,200],{"key":20,"text":195,"correct":22},"1%",{"key":24,"text":197,"correct":29},"2%",{"key":27,"text":199,"correct":22},"3%",{"key":31,"text":201,"correct":22},"4%",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":27,"analysis":33},881716,"按我国逐步淘汰消耗臭氧层物质的国家方案修订稿规定，在下列制冷剂中，离心式制冷机可选择( )替代CFC-11。",[206,208,210,212],{"key":20,"text":207,"correct":22},"R717",{"key":24,"text":209,"correct":22},"R132",{"key":27,"text":211,"correct":29},"R134a或R123",{"key":31,"text":213,"correct":22},"R22",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":27,"analysis":33},881717,"下列室内供暖系统主干管中，哪一项是不需要保温的？( )",[218,220,222,224],{"key":20,"text":219,"correct":22},"不通行地沟内的供水、回水管道",{"key":24,"text":221,"correct":22},"高低压蒸汽管道",{"key":27,"text":223,"correct":29},"车间内蒸汽凝结水管道",{"key":31,"text":225,"correct":22},"通过非供暖房间的管道",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":24,"analysis":33},881718,"多层建筑内高度不超过( )的房间应划分防烟分区o",[230,232,234,236],{"key":20,"text":231,"correct":22},"5m",{"key":24,"text":233,"correct":29},"6m",{"key":27,"text":235,"correct":22},"8m",{"key":31,"text":237,"correct":22},"10m",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":240,"answer":31,"analysis":33},881719,[241,243,245,247],{"key":20,"text":242,"correct":22},"0.40",{"key":24,"text":244,"correct":22},"0.44",{"key":27,"text":246,"correct":22},"0.48",{"key":31,"text":248,"correct":29},"0.55",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":20,"analysis":33},881720,"确定半容积式加热器的设计小时供热量的依据是( )。",[253,255,257,259],{"key":20,"text":254,"correct":29},"热水系统的设计小时耗热量",{"key":24,"text":256,"correct":22},"热水系统的设计小时耗热量减去加热器的贮热量",{"key":27,"text":258,"correct":22},"热水系统的设计小时耗热量减去加热器贮热量的一半",{"key":31,"text":260,"correct":22},"按照设计秒流量计算的热水系统耗热量",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":33},881721,"有一风机盘管空调系统，夏季总冷负荷为1000kW，冬季总热负荷为900kW，冬季供热为60℃\u002F50℃的热水，夏季供冷为7℃\u002F12℃的冷水，夏季工况管道的实测阻力为0.26MPa，水的比热容为4.18kJ\u002F(kg·K)，则冬季工况管道的阻力接近( )。",[265,267,269,271],{"key":20,"text":266,"correct":29},"0.032MPa",{"key":24,"text":268,"correct":22},"0.055MPa",{"key":27,"text":270,"correct":22},"0.15MPa",{"key":31,"text":272,"correct":22},"0.20MPa",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":20,"analysis":33},881722,"采用温湿度独立控制的空调系统时，承担显热负荷的冷水机组的供水温度不宜低于( )。",[277,279,281,283],{"key":20,"text":278,"correct":29},"16℃",{"key":24,"text":280,"correct":22},"14℃",{"key":27,"text":282,"correct":22},"12℃",{"key":31,"text":183,"correct":22},{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":31,"analysis":33},881723,"在空调用制冷装置中，高压液体制冷剂过冷，一般可采用增大冷凝器面积( )，使冷凝器中有一定液体制冷剂，并使冷却水和制冷剂呈逆流方式实现。",[288,290,292,294],{"key":20,"text":289,"correct":22},"20%～25%",{"key":24,"text":291,"correct":22},"15%～20%",{"key":27,"text":293,"correct":22},"10%～15%",{"key":31,"text":295,"correct":29},"5%～10%",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":24,"analysis":33},881724,"燃气红外辐射供暖系统的布置，下列哪个说法是正确的？( )",[300,302,304,306],{"key":20,"text":301,"correct":22},"沿四周外墙、外门处辐射器的散热量不得小于总散热量的60%",{"key":24,"text":303,"correct":29},"使用数量多、功率小的发生器，室内温度场更均匀",{"key":27,"text":305,"correct":22},"发生器功率越大，安装高度应越小",{"key":31,"text":307,"correct":22},"发生器必须串联安装",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":31,"analysis":33},881725,"层数超过( )层的高层建筑，其机械加压送风的送风系统和送风量应分段设计。",[312,314,316,318],{"key":20,"text":313,"correct":22},"10",{"key":24,"text":315,"correct":22},"18",{"key":27,"text":317,"correct":22},"24",{"key":31,"text":319,"correct":29},"32",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":27,"analysis":33},881726,"冷热电三联供系统运行时，当冷热负荷大于余热供热能力时，应( )。",[324,326,328,330],{"key":20,"text":325,"correct":22},"加大发电量，获得足够余热量",{"key":24,"text":327,"correct":22},"降低燃气发粤效率，获得足够余热量",{"key":27,"text":329,"correct":29},"启动辅助冷热源补充",{"key":31,"text":331,"correct":22},"以上均可",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":20,"analysis":33},881727,"关于集中供暖系统热量表的设置，下列说法哪个是错误的？( )",[336,338,340,342],{"key":20,"text":337,"correct":29},"建筑物内每个用户应安装户用热量表",{"key":24,"text":339,"correct":22},"锅炉房回水总管上应设置热量表",{"key":27,"text":341,"correct":22},"热力站一次网回水总管上应设置热量表",{"key":31,"text":343,"correct":22},"建筑物热力人口处必须设置楼前热量表",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":31,"analysis":33},881728,"空调房间的冬季热负荷计算，应该按照下列哪一项进行？( )",[348,350,352,354],{"key":20,"text":349,"correct":22},"按不稳定传热简化计算",{"key":24,"text":351,"correct":22},"按夏季的冷负荷加以修正",{"key":27,"text":353,"correct":22},"按谐波反应法计算",{"key":31,"text":355,"correct":29},"按稳定传热方法计算",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":31,"analysis":33},881729,"关于绿色建筑对于暖通空调专业在总图布置中的要求，下列哪项说法是错误的？( )",[360,362,364,366],{"key":20,"text":361,"correct":22},"建筑总平面设计有利于冬季日照并避开冬季不利风向，夏季有利于自然通风",{"key":24,"text":363,"correct":22},"住区内部或场地内无排放超标的污染源",{"key":27,"text":365,"correct":22},"住区风环境有利于夏季、过渡季的自然通风",{"key":31,"text":367,"correct":29},"太阳能光伏板发电量占建筑总用电量的2%",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":33},881730,"某物料输送过程采用密闭罩，有关吸风口的设计，错误的应是下列哪一项？( )",[372,374,376,378],{"key":20,"text":373,"correct":29},"斗式提升机输送冷物料，于上部设置吸风口",{"key":24,"text":375,"correct":22},"粉状物料下落时，物料的飞溅区不设置吸风口",{"key":27,"text":377,"correct":22},"皮带运输机上吸风口至卸料溜槽距离至少应保持300～500mm",{"key":31,"text":379,"correct":22},"粉碎物料时，吸风口风速不宜大于2.0m\u002Fs",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":20,"analysis":33},881731,"过渡季使用大量新风的空调系统，应采取的措施是( )。",[384,386,388,390],{"key":20,"text":385,"correct":29},"满足新风量变化的排风",{"key":24,"text":387,"correct":22},"单风机系统",{"key":27,"text":389,"correct":22},"独立的新风系统",{"key":31,"text":391,"correct":22},"VAV系统",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":27,"analysis":33},881732,"管网用户侧和热网采用带混水装置的直连。热网侧热水为150\u002F70℃，用户侧为95\u002F70℃，用户侧流量为200t\u002Fh，计算混水装置流量为下列哪一项？",[396,398,400,402],{"key":20,"text":397,"correct":22},"120",{"key":24,"text":399,"correct":22},"200",{"key":27,"text":401,"correct":29},"440",{"key":31,"text":403,"correct":22},"620",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":24,"analysis":33},881733,"某乙类单层生产厂房，建筑面积4000㎡。通风、空气调节系统的风管上应设防火阀的地方，下列哪一项是错误的？( ).",[408,410,412,414],{"key":20,"text":409,"correct":22},"风管穿越防火分区处",{"key":24,"text":411,"correct":29},"风管穿越防烟分区处",{"key":27,"text":413,"correct":22},"风管穿越防火分隔处的变形缝的两侧",{"key":31,"text":415,"correct":22},"风管穿越通风、空气调节机房的隔墙和楼板处",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":27,"analysis":33},881734,"室内供暖系统的水压试验要求，对采用不同管材的严格程度的顺序为( )。",[420,422,424,426],{"key":20,"text":421,"correct":22},"钢管、塑料管、复合管",{"key":24,"text":423,"correct":22},"均相同",{"key":27,"text":425,"correct":29},"塑料管、复合管、钢管",{"key":31,"text":427,"correct":22},"复合管、钢管、塑料管",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":430,"answer":27,"analysis":33},881735,[431,432,433,434],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":29},{"key":31,"text":33,"correct":22},{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":20,"analysis":33},881736,"机械通风的进排风口在同一高度时，水平距离不宜小于( )m。",[439,441,443,445],{"key":20,"text":440,"correct":29},"20",{"key":24,"text":442,"correct":22},"11",{"key":27,"text":444,"correct":22},"8",{"key":31,"text":446,"correct":22},"9",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":24,"analysis":33},881737,"衡量开启式制冷压缩机能源效率的参数是( )。",[451,453,455,457],{"key":20,"text":452,"correct":22},"APF",{"key":24,"text":454,"correct":29},"COP",{"key":27,"text":456,"correct":22},"IPLV",{"key":31,"text":458,"correct":22},"SEER",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":27,"analysis":33},881738,"关于加压送风系统，下列说法错误的是( )。",[463,465,467,468],{"key":20,"text":464,"correct":22},"层数超过32层的高层建筑，其送风系统及送风量应分段设计",{"key":24,"text":466,"correct":22},"楼梯间宜每隔2～3层设一个加压送风口，前室的加压送风口应每层设一个",{"key":27,"text":33,"correct":29},{"key":31,"text":469,"correct":22},"加压送风系统的管道上不应设置防火阀",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":24,"analysis":33},881739,"对某新建居住小区设街区水一水换热站，小区内建筑均为低温热水地板辐射供暖系统，下列补水量估算和补水泵台数的确定，正确的是何项?( )。",[474,476,478,480],{"key":20,"text":475,"correct":22},"每台按供暖系统水容量的1%～2%，3台(两用一备)",{"key":24,"text":477,"correct":29},"每台按供暖系统循环水容量的1%～2%，2台",{"key":27,"text":479,"correct":22},"每台按供暖系统水容量的2%～3%，2台",{"key":31,"text":481,"correct":22},"每台按供暖系统循环水容量的2%～3%，3台(两用一备)",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":31,"analysis":33},881740,"空调水系统为闭式系统时，调试时常发生因水系统中的空气不能完全排除，而造成无法正常运行的情况，试问引起该问题的原因是下列哪一项？",[486,488,490,492],{"key":20,"text":487,"correct":22},"水泵的设计扬程太小",{"key":24,"text":489,"correct":22},"水泵的设计流量不足",{"key":27,"text":491,"correct":22},"膨胀水箱的底部与系统最高点的高差过大",{"key":31,"text":493,"correct":29},"膨胀水箱的底部与系统最高点的高差不够",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":24,"analysis":33},881741,"设置于地下室、半地下室使用燃气的厨房，其独立的机械送排风系统所选取的通风换气量，下列哪一项是错误的？",[498,500,502,504],{"key":20,"text":499,"correct":22},"正常工作时，换气次数不应小于6次\u002Fh",{"key":24,"text":501,"correct":29},"事故通风时，换气次数不应小于10次\u002Fh",{"key":27,"text":503,"correct":22},"不工作时，换气次数不应小于3次\u002Fh",{"key":31,"text":505,"correct":22},"当燃烧所需的空气由室内吸取时，同时应满足燃烧所需的空气量",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":27,"analysis":33},881742,"下列哪种管道为严禁穿过厂房中防火墙的管道？",[510,512,514,516],{"key":20,"text":511,"correct":22},"热水采暖干管",{"key":24,"text":513,"correct":22},"蒸汽采暖管道",{"key":27,"text":515,"correct":29},"有爆炸危险厂房内的排风管道",{"key":31,"text":517,"correct":22},"有爆炸危险厂房内的送风管道",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":31,"analysis":33},881743,"设计中，哪一项离心式制冷机机房的要求是不正确的？",[522,524,526,528],{"key":20,"text":523,"correct":22},"应考虑机房设备安装孔与运输设备的预留",{"key":24,"text":525,"correct":22},"应设置给水、排水设施",{"key":27,"text":527,"correct":22},"应有良好的室内通风设施",{"key":31,"text":529,"correct":29},"机房的隔墙应为防爆墙",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":24,"analysis":33},881744,"在处理风量、粉尘性质及浓度相同时，旋风除尘器的几何尺寸变化，可使其除尘效率提高，指出下列哪一种尺寸变化是错误的?( )。",[534,536,538,540],{"key":20,"text":535,"correct":22},"减小圆筒直径",{"key":24,"text":537,"correct":29},"加长锥体长度",{"key":27,"text":539,"correct":22},"加长圆筒长度",{"key":31,"text":541,"correct":22},"增大排出口直径",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":24,"analysis":33},881745,"热水散热器供暖单管跨越式立管，其他条件不变，如果缩小跨越管段的管径，对整个立管的影响是( )。",[546,548,550,552],{"key":20,"text":547,"correct":22},"流量增大、阻力减小",{"key":24,"text":549,"correct":29},"流量减小、阻力增大",{"key":27,"text":551,"correct":22},"流量和阻力均减小",{"key":31,"text":553,"correct":22},"流量和阻力均增大",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":31,"analysis":33},881746,"当屋面内设有通风空气间层时，计算围护结构冬季传热系数时，应( )。",[558,560,562,564],{"key":20,"text":559,"correct":22},"按照热流自下而上计算空气间层热阻",{"key":24,"text":561,"correct":22},"按照不同间层厚度计算空气间层热阻",{"key":27,"text":563,"correct":22},"按照热流自下而上和不同间层厚度计算空气间层热阻",{"key":31,"text":565,"correct":29},"不计算空气间层热阻",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":20,"analysis":33},881747,"冷热电三联供系统发电机台数不宜少于( )。",[570,572,574,576],{"key":20,"text":571,"correct":29},"2台",{"key":24,"text":573,"correct":22},"3台",{"key":27,"text":575,"correct":22},"4台",{"key":31,"text":577,"correct":22},"无所谓",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":24,"analysis":33},881748,"目前在洁净技术中常用的大气尘浓度表示方法，正确的应是下列哪一项？",[582,584,586,588],{"key":20,"text":583,"correct":22},"沉降浓度",{"key":24,"text":585,"correct":29},"计数浓度",{"key":27,"text":587,"correct":22},"计重浓度",{"key":31,"text":589,"correct":22},"以上三种方法都常用",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":24,"analysis":33},881749,"设有电加热器的通风系统，电加热器前后( )处风管和绝热层应为不燃绝热材料。",[594,596,598,600],{"key":20,"text":595,"correct":22},"500mm",{"key":24,"text":597,"correct":29},"800mm",{"key":27,"text":599,"correct":22},"1000mm",{"key":31,"text":601,"correct":22},"1200mm",{"id":603,"libraryId":5,"type":15,"typeLabel":16,"stem":604,"options":605,"answer":31,"analysis":33},881750,"建筑物耗热量指标计算中，正确的做法是( )。",[606,608,609,611],{"key":20,"text":607,"correct":22},"建筑物内部得热量按5.8W\u002F㎡取值",{"key":24,"text":33,"correct":22},{"key":27,"text":610,"correct":22},"换气体积为建筑物外表面与底层地面围成的体积",{"key":31,"text":612,"correct":29},"室外温度取供暖期室外平均温度",[614,617,620,623,626,629],{"id":15,"name":615,"category":7,"favorite":616},"领导干部任职前廉政法规知识测试题",92,{"id":618,"name":619,"category":7,"favorite":15},595,"建筑结构与设备",{"id":621,"name":622,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":624,"name":625,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":627,"name":628,"category":7,"favorite":8},534,"BIM工程师",{"id":630,"name":628,"category":7,"favorite":8},535]